Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Graphite specimens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ultrasonic Monitoring of Ply Crack and Delamination Formation in Composite Tube Under Torsion Load

As a simple model of a rotor spar, a circular graphite-epoxy composite laminate cylinder was subjected to cyclic torsional load. The test section of the cylindrical specimen varied from four to six plies of plus or minus 45 degree fibers, due to intentional ply overlaps and gaps. A layer of 13-micrometer Teflon film was inserted between plies at three locations to serve as delamination initiators. A commercial X-Y scanner was mounted to the load frame to enable ultrasonic inspection without removing the specimen. A focused immersion probe was mounted in a captive water column with a rugged Nitrile membrane tip, which was coupled to the cylinder using a mist of soapy water. The transducer was aligned normal to the cylinder surface using the X-axis. Scanning was performed along the length of the specimen with the Y-axis and the specimen was incrementally rotated by the torsion head of the load frame. After 350k cycles of torsion, several linear 45 degree diagonal indications appeared as 5-40% attenuation of the back wall echo, with no apparent echoes from the interior of the composite, suggesting through-ply cracks in the innermost ply. Crack indications grew and new cracks appeared as torsion cycling continued. Internal reflections from delaminations associated with the growing ply cracks appeared after 500k cycles. Three areas of extensive multi-layer delaminations appeared after 1150k cycles. Failure of the specimen occurred at 1600k cycles. The observed progressive damage was not associated with the Teflon inclusions. Concurrent thermographic measurements provided lower resolution confirmation of the damage observed.

Johnston, P. H.↗

Properties of autoclaved Gr/PI composites made from improved tack PMR-15 prepreg

Autoclave processing studies were conducted, using improved tack PMR-15 prepreg, to determine the effect of tack enhancing PMR resin modifications on composite processability and mechanical properties. Improved tack graphite fiber reinforced PMR-15 prepregs were prepared and exposed to ambient conditions for various times and then autoclave molded into composites. Composite specimens were prepared and tested for flexural and interlaminar shear strengths at room temperature and 316 C. The retention of flexural and interlaminar shear strength as a function of exposure in air at 316 C was also determined. The results show that the modified PMR resin solutions provide prepreg with improved tack and drape retention characteristics without adversely affecting processability or mechanical properties of autoclave molded graphite fiber reinforced PMR-15 composites.

Vannucci, R. D.↗

Structural Performance of a Compressively Loaded Foam-Core Hat-Stiffened Textile Composite Panel

A structurally efficient hat-stiffened panel concept that utilizes a structural foam as a stiffener core material has been designed and developed for aircraft primary structural applications. This stiffener concept is fabricated from textile composite material forms with a resin transfer molding process. This foam-filled hat-stiffener concept is structurally more efficient than most other prismatically stiffened panel configurations in a load range that is typical for both fuselage and wing structures. The panel design is based on woven/stitched and braided graphite-fiber textile preforms, an epoxy resin system, and Rohacell foam core. The structural response of this panel design was evaluated for its buckling and postbuckling behavior with and without low-speed impact damage. The results from single-stiffener and multi-stiffener specimen tests suggest that this structural concept responds to loading as anticipated and has excellent damage tolerance characteristics compared to a similar panel design made from preimpregnated graphite-epoxy tape material.

Ambur, Damodar R.↗

Low-Temperature Annealing of Nanoscale Defects in Polycrystalline Graphite

Polycrystalline graphite contains multi-scale defects, which are difficult to anneal thermally because of the extremely high temperatures involved in the manufacturing process. In this study, we demonstrate annealing of nuclear graphite NBG-18 at temperatures below 28 °C, exploiting the electron wind force, a non-thermal stimulus. High current density pulses were passed through the specimens with a very low-duty cycle so that the electron momentum could mobilize the defects without heating the specimen. The effectiveness of this technique is presented with a significant decrease in electrical resistivity, defect counts from X-ray computed tomography, Raman spectroscopy, and nanoindentation-based mechanical characterization. Such multi-modal evidence highlights the feasibility of nanoscale defect control at temperatures about two orders of magnitude below the graphitization temperature.

Liu, Gongyuan↗

Impact response of composite fuselage frames

Graphite-epoxy frames were drop tested onto a concrete floor to simulate crash loadings. The frames have Z-shaped cross sections typical of designs often proposed for fuselage structure of advanced composite transports. A diameter of six feet for the frames was chosen to reduce specimen fabrication costs and to facilitate testing. Accelerometer, strain gage, and photographic measurements are presented which characterize the impact behavior of frames with differing masses to represent structural or seat/occupant masses. Failures of the graphite-epoxy frames involved complete separations through the cross section. All damage to the lightly loaded composite frames was confined to an area close to the impact point. Subsequent failures left and right of the impact point occurred for the more heavily loaded specimens.

Boitnott, Richard L.↗

Failure analysis of a graphite/epoxy laminate subjected to bolt-bearing loads

Quasi-isotropic graphite-epoxy laminates (T300/5208) were tested under bolt bearing loads to study failure modes, strengths, and failure energy. Specimens had a range of configurations to produce failures by the three nominal failure modes: tension, shearout, and bearing. Radiographs were made after damage onset and after ultimate load to examine the failure modes. Also, the laminate stresses near the bolt hole calculated for each test specimen configuration, and then used with a failure criterion to analyze the test data. Failures involving extensive bearing damage were found to dissipate significantly more energy than tension dominated failures. The specimen configuration influenced the failure modes and therefore also influenced the failure energy. In the width-to-diameter ratio range of 4 to 5, which is typical of structural joints, a transition from the tension mode to the bearing mode was shown to cause a large increase in failure energy. The failure modes associated with ultimate strength were usually different from those associated with the damage onset. Typical damage sequences involved bearing damage onset at the hole boundary followed by tension damage progressing from the hole boundary.

Crews, J. H., Jr.↗

Fixed Eigenvector Analysis of Thermographic NDE Data

Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. This paper will discuss an alternative method of analysis that has been developed where a predetermined set of eigenvectors is used to process the thermal data from both reinforced carbon-carbon (RCC) and graphiteepoxy honeycomb materials. These eigenvectors can be generated either from an analytic model of the thermal response of the material system under examination, or from a large set of experimental data. This paper provides the details of the analytic model, an overview of the PCA process, as well as a quantitative signal-to-noise comparison of the results of performing both conventional PCA and fixed eigenvector analysis on thermographic data from two specimens, one Reinforced Carbon-Carbon with flat bottom holes and the second a sandwich construction with graphite-epoxy face sheets and aluminum honeycomb core.

Cramer, K. Elliott↗

Drop testing and analysis of six-foot diameter graphite-epoxy frames

Graphite-epoxy frames were drop tested onto a concrete floor to simulate crash loadings. The frames have Z-shaped cross-sections typical of designs often proposed for fuselage structure of advanced composite transports. The 6-foot diameter of the frames was chosen to reduce specimen fabrication costs and to facilitate testing. Response of the frames from accelerometer, strain gage, and photographic measurements are presented which characterize the behavior under 25-30 fps vertical impact velocity onto concrete. Failure of the graphite-epoxy frames involved a complete separation through the cross section near the impact point. All damage to the composite frame was confined to an area close to the impact point. Failure of aluminum frames tested for comparison were different from the composite specimens. The aluminum frames yielded (plastic hinges formed) at several locations around the lower portion of the frame without failing completely across the section.

Boitnott, R. L.↗

Material characterization of composite laminates using low-frequency plate wave dispersion data

A recently developed ultrasonic techique which has been successful in monitoring the integrity of advanced structures is described. The technique is based on a two-transducer contact type arrangement that can be used to determine the dispersion curves of guided waves generated within the specimen. The phase velocity of antisymmetric plate waves is determined through spectral analysis of signals recorded from a lead break source on the surface of graphite epoxy laminates. The influence of all five stiffness constants on the dispersion curves of both symmetric and antisymmetric plate waves is theoretically investigated for propagation at 0, 45, and 90 deg to the fibers. All but c12 were found to have a strong influence on the dispersion curves in this frequency range. The fit with the theoretically predicted dispersion curves was excellent for propagation parallel and perpendicular to the fibers in the unidirectional specimen and good for the other cases considered.

Mal, Ajit K.↗

Mercury Modeling of TREAT Big-BUSTER Free Field Characterization Experiments

This report summarizes modeling of Big-BUSTER free field characterization (FFC) experiments at the Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) reactor performed from December 20th, 2023, to February 22nd, 2024. TREAT is an air-cooled graphite moderated research reactor that can be used to study material response to neutron irradiation. The BUSTER (Broad Use Specimen Transient Experiment Rig) refers to a containment module for placing experiments in the reactor core. The Big-BUSTER is an analogous platform for a modified core configuration with a larger experimental cavity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Graphite ablation at high temperatures

Graphite ablation under high temperatures for large outer planets entry probes, correlating mass loss rates with surface temperatures and specimen nose cone radii

Dickey, R. R.↗

Static and dynamic response of graphite-epoxy curved frames

Experiments were conducted to measure the three-dimensional static and vibratory response of two graphite-epoxy, thin-walled, open section frames. The frames are semicircular with a radius of three feet. One specimen had an I cross section and the other had a channel cross section. The experimental data is used to evaluate a mixed finite element model of the frames that is based on Vlasov-type, thin-walled, open section curved beam theory.

Collins, J. S.↗

Through-thickness fracture behavior of neutron-irradiated nuclear graphite NBG-17 Using X-ray micro-CT

Achieving precise control over crack propagation in nuclear graphite and conducting quantitative analysis remain challenging. In this study, the through-thickness fracture behavior of pristine and neutron-irradiated (700 °C, ∼7 dpa) NBG-17 nuclear graphite was investigated using split-disc testing coupled with micro-computed tomography (micro-CT). A notably lower number of micropores was observed in the neutron-irradiated specimen. The fracture toughness of neutron-irradiated NBG-17 was measured to be 1.45 MPa√m, compared to 1.17 ± 0.05 MPa√m for the pristine specimen. In both materials, cracks were found to initiate at the filler–binder interface, and often correlated with microstructural features such as pores and thermal cracks. Crack bridging and deflections emerged as the primary toughening mechanisms in both unirradiated and irradiated NBG-17. However, compared with the pristine specimen, the cracks in the neutron-irradiated specimen were more likely to grow trans granularly, resulting in less deflected crack paths. The reduced micro-porosity and strengthened filler–binder boundaries were considered to be the cause of the observed differences in crack morphologies. In conclusion, this study provides a qualitative analysis of the fracture behavior of neutron-irradiated nuclear graphite in the absence of radiolytic oxidation.

36 - MATERIALS SCIENCE↗

On thermal stress failure of the SNAP-19A RTG heat shield

Results of a study on thermal stress problems in an amorphous graphite heat shield that is part of the launch-abort protect system for the SNAP-19A radio-isotope thermoelectric generators (RTG) that will be used on the Viking Mars Lander are presended. The first result is from a thermal stress analysis of a full-scale RTG heat source that failed to survive a suborbital entry flight test, possibly due to thermal stress failure. It was calculated that the maximum stress in the heat shield was only 50 percent of the ultimate strength of the material. To provide information on the stress failure criterion used for this calculation, some heat shield specimens were fractured under abort entry conditions in a plasma arc facility. It was found that in regions free of stress concentrations the POCO graphite heat shield material did fracture when the local stress reached the ultimate uniaxial stress of the material.

Pitts, W. C.↗

Accelerated viscoelastic characterization of T300-5208 graphite-epoxy laminates

A viscoelastic response scheme for the accelerated characterization of polymer-based composite laminates in applied to T300/5208 graphite/epoxy. The response of uni-directional specimens is modeled. The transient component of the viscoelastic creep compliance is assumed to follow a power law approximation. A recursive relationship is developed, based upon the Schapery single-integral equation, which allows approximation of a continuous time-varying uniaxial load using discrete steps in stress. The viscoelastic response of T300/5208 to transverse normal and shear stresses is determined unsing 90 deg and 10 deg off-axis tensile specimens. In each case the seven viscoelastic material parameters required in the analysis are determined experimentally using short-term creep and creep recovery tests. It is shown that an accurate measure of the power law exponent is crucial for accurate long-term prediction. A short term test cycle selection procedure is proposed, which should provide useful guidelines for the evaluation of other viscoelastic materials.

Tuttle, M. E.↗

Effect of orthotropic properties and panel width on the compression strength of graphite-epoxy laminates with holes

An experimental study conducted to evaluate the effect of laminate orthotropic properties and panel width on the compression strength of 48-ply graphite-epoxy laminates with drilled holes is described. The test results are evaluated on the basis of hole size and specimen width and are used in determining parameters necessary for predicting trends using the point stress failure criterion. Good agreement is obtained between experimental and predicted values of failure for panels fabricated from two quasi-isotropic laminates and one orthotropic laminate. The results suggest that panels of different widths having holes that are large in relation to the failure prediction parameter should be included in any test program conducted to develop prediction trends that may be used in design applications.

Rhodes, M. D.↗

Detection and Characterization of Imperfections in Composite Pressure Vessels

The thermographic evaluation of composite structures for delaminations, disbonds, inclusions, porosity and microcracking has proven to be a valuable asset in the field of nondestructive testing. Coupling large area coverage, variable sensitivity and minimal surface contact with a photographic type image representation of structural anomalies; thermography has become a primary inspection method for composite structures. Thermography works well for locating both surface and subsurface defects in most composite systems ranging in thickness of up to 0.25 inch (0.64 cm) or more. The thermographic method for inspection of composite structures typically involves applying an external source of heat to the structure and then recording the changes in the surface heat profile manifested by embedded defects or by material property variations. If these temperature variations are large enough and an infrared camera with sufficient sensitivity is used, then the material or structural abnormality can be detected and referred back to its source. Interpreting the information given in a thermogram, can be a difficult task under ideal circumstances and extremely challenging in a real world setting. Variables including depth, thermal conductivity, orientation and size of the abnormality can all have a great influence on how its heat pattern will be seen by the imager. The work discussed in this paper illustrates how the microstructure of several commonly found defects in composite structures relate to their thermographic image counterpart. Two test cases are studied herein, including a large graphite/epoxy RP-1 fuel tank and a graphite composite cryogenic fuel feedline. The structures used in this study were designed to serve as manufacturing proof of concept specimens and to undergo hydroburst testing to verify manufacturing practices and structural design. Prior to hydrostatic testing the structures underwent 100% thermographic evaluation to ensure that no manufacturing or handling damage was present. Due to a large inclusion found in the feedline, it was pulled from service and dissected without performing the hydroproof The thermographic indications found in the RP-1 tank were below critical limits so it underwent a complete hydroproof loading series and finally a hydroburst. Following the hydroburst samples were cut from the tank in regions where thermography had located damage before the test. These regions were thermographically and then were cross-sectioned and photomicrographed.

Walker, James L.↗