Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Tracking Radioactive Isotopes in HVAC and Application for Hot Cell Analyses - 20155

In recent years, the surge in the number of isotope production facilities under design has increased the need to analyze isotope migration in facility Heating, Ventilation, and Air Conditioning (HVAC) during normal operations and accident scenarios. These facilities are used to produce isotopes for medical, security, and industrial applications and as such are subject to license and regulatory requirements 10CFR20, 10CFR30, 10CFR50, and 10CFR70. GOTHIC, a general-purpose thermal-hydraulics software package, includes the ability to model isotopic tracers, radioactive decay and isotope migration as well as HEPA and charcoal filters for isotope retention. A GOTHIC model was developed by Zachry Nuclear Engineering (ZNE) to examine the effect of negative room pressure, HEPA filtration, and HVAC fluctuations on radiation areas, hot cells and gloveboxes. Radioactive tracers were used to simulate the concentration of spills within contaminated areas, track the migration of isotopes of interest, and determine the isotopic retention and buildup on facility HEPA filters. A variety of isotopes with concern to dose (e.g., Kr-85, Sr-90, I-131, etc.), including their decay and progeny, are included in the analysis. Negative pressures are maintained in the regions of interest by a representative central HVAC system equipped with a volumetric fan that exhausts to the environment after a series of isolation valves and HEPA filters. GOTHIC is an industry trusted tool for providing engineering solutions for a variety of applications, including fission product tracking, aerosol and particulate transport and ventilation assessments. The software provides an integrated analysis environment that includes a graphical user interface (GUI) for constructing analysis models, a numerical solver that includes parallel processing capabilities and a post-processor for evaluating simulation results. It solves the conservation equations for mass, momentum and energy for multicomponent, multi-phase flow in lumped parameter and multi-dimensional geometries (1, 2, or full 3D), including the effects of turbulence, diffusion and buoyancy. It has been developed and maintained under a Quality Assurance program in compliance with the requirements of 10CFR50 Appendix B and applicable portions of ASME NQA-1 since 1995. GOTHIC has been used for assessing both forced and natural convection conditions for a wide range of applications, including: - Tracking concentration of hazardous gases and chemicals for habitability and safety assessments - Determining ventilation and filtration requirements and optimizing location and arrangement of these systems - Room heat-up, including diverse and Flexible coping strategies for Extended Loss of AC Power (FLEX/ELAP) - Equipment Qualification (EQ) A distinctive feature of GOTHIC is the ability to track many different fields/substances in a simulation, including user defined tracer elements, in the liquid, vapor and droplet fields as well as surfaces and filters. This capability allows GOTHIC to model fission product transport and release or the removal of particulates or harmful toxins from exhaust gases using a spray scrubber or other types of filtration systems. GOTHIC also includes models for engineered equipment, such as fans, filters, charcoal filters, dryers/demisters, dampers, etc. The aerosols and other filtered material are removed or accumulated in these components. The range of aerosol and radiological applications that GOTHIC has been used for includes: - Source Term: Primary Coolant (Equilibrium) Activity; Non-Water Coolant Source/Leakage. - Conditions for Iodine Re-evolution: Sump/Suppression Pool Conditions and pH; - RWST Conditions and pH. - Isotope Removal Mechanisms: Containment Sprayed and Unsprayed Region Mixing; Charcoal Filter Heating due to Iodine decay. - Radionuclide Transport and Decay: Post-LOCA Release in containment; Transport between connected Compartments and vent systems; Groundwater transport of radionuclides. - Non-Newtonian Fluid modeling for sludge, waste tanks, etc. ADAMS ML071581053 (titled 'Best Practice Guidelines for the use of CFD in Nuclear Reactor Safety Applications') poses guidelines for applying single phase CFD codes in nuclear reactor safety problems and GOTHIC is listed as a 'tool for 3D flows' and 'dispersal and deposition of radionuclides.' The Nuclear Quality Assurance (NQA) pedigree of GOTHIC is an important aspect for applications in the nuclear industry. The fundamental tracer models (convective transport, molecular and turbulent diffusion, removal mechanisms, etc.) have been verified using analytical solutions and validated against applicable separate effects tests. Also, GOTHIC has been benchmarked to many integrated effects tests, including Phebus FP (Fission Product). GOTHIC gives good agreement for the buildup and decay of fission products in Phebus Test 3. The model developed by ZNE demonstrates GOTHIC's applicability and acceptability for use in analyzing the migration and retention of radioactive isotopes and their progeny in normal operation and accident scenario analyses for isotope production facilities, hot cells, and gloveboxes. The tracer activities calculated by GOTHIC can then be used in downstream radiation transport and shielding codes like RADTRAD-NAI{sup C}, MCNP{sup R}, and MicroShield{sup R} to determine on-site and of-site doses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of CFD Flow Analysis for Nuclear Facility Ventilation Systems

Understanding and modeling of particulate transport has importance related to safety in ventilated environments that contain hot cells, gloveboxes, and fume hoods. In particular, good modeling of the airflow in these spaces is required to understand areas of stagnation where particles drop out of the free stream and accumulate. This accumulation of particulate can cause either contamination and/or higher than acceptable local dose levels. It is known that multiple sites across the DOE complex take credit for hot cells, gloveboxes, and/or hoods in their safety basis for providing a defense-in-depth benefit for both onsite and offsite releases. By providing confinement of radioactive materials, such features serve to reduce direct doses to facility workers and mitigate the consequences to the environment due to an uncontrolled release. Each of these features has access points that interface with the personnel space. Understanding how air flow behaves at these access points is of great interest to those performing hazard analysis. Computational Fluid Dynamics (CFD) can be used to analyze and model the flows in hot cells and glove boxes as a way to confirm operation. While CFD capability continues to advance, there are still important modeling assumptions that are left to the analyst's discretion. These are most notably the choice of the turbulence models, mesh structure, and wall boundary condition assumptions used in the model. In this work, we apply CFD in modeling airflow through an occupiable work area of the Alpha Gamma Hot Cell Facility (AGHCF) at Argonne National Laboratory (ANL). This modeling is then compared to field test data to both inform and verify the modeling assumptions. Based on the results of field tests, modeling assumptions and boundary conditions are refined and the process is repeated until the results are found to be reliable with a high level of confidence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DEVELOPMENT AND DEPLOYMENT OF VACUUM SALT DISTILLATION AT THE SAVANNAH RIVER SITE

The Savannah River Site has a mission to dissolve fissile materials and disposition them. The primary fissile material is plutonium dioxide (PuO{sub 2}). To support dissolution of these materials, the Savannah River National Laboratory (SRNL) designed and demonstrated a vacuum salt distillation (VSD) apparatus using both representative radioactive samples and non-radioactive simulant materials. Vacuum salt distillation, through the removal of chloride salts, increases the quantity of materials suitable for processing in the site's HB-Line Facility. Small-scale non-radioactive experiments at 900-950 C show that >99.8 wt % of the initial charge of chloride salt distilled from the sample boat with recovery of >99.8 wt % of the ceric oxide (CeO{sub 2}) - the surrogate for PuO{sub 2} - as a non-chloride bearing 'product'. Small-scale radioactive testing in a glovebox demonstrated the removal of sodium chloride (NaCl) and potassium chloride (KCl) from 13 PuO{sub 2} samples. Chloride concentrations were distilled from a starting concentration of 1.8-10.8 wt % to a final concentration <500 mg/kg chloride. Initial testing of a non-radioactive, full-scale production prototype is complete. A designed experiment evaluated the impact of distillation temperature, time at temperature, vacuum, product depth, and presence of a boat cover. Significant effort has been devoted to mechanical considerations to facilitate simplified operation in a glovebox.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Zinc 65 Contamination after Vacuum Thermal Process

Radioactive contamination with a gamma energy emission consistent with {sup 65}Zn was detected in a glovebox following a vacuum thermal process. The contaminated components were removed from the glovebox and subjected to examination. Selected analytical techniques were used to determine the nature of the precursor material, i.e., oxide or metallic, the relative transferability of the deposit and its nature. The deposit was determined to be borne from natural zinc and was further determined to be deposited as a metallic material from vapor.

 Contamination↗

Electrolyte Vapor Induced Passivation and Transition Metal Redox on Electrode Active Materials

The gaseous environment that battery electrodes are exposed to is critical to their electrochemical performance, and yet, the impact of vapor-phase components in the glovebox is relatively unexplored. In this study, we examine how the surface of Li 4 Ti 5 O 12 and LiFePO 4 composite electrodes evolve upon exposure to 1 M LiPF 6 in ethylene carbonate:dimethyl carbonate electrolyte vapors in an argon-filled glovebox. Spatially resolved X-ray photoemission electron microscopy and X-ray photoelectron spectroscopy reveal that even brief (15 minutes) contact with electrolyte vapor initiates the formation of a LiF film and changes the oxidation state of transition metals at the particle surface. Notably, these modifications occur selectively on active material particles and not on binder or conductive carbon, underscoring the specificity of vapor-induced reactions. Prolonged exposure to electrolyte vapor over the course of 1 week yields thicker, more chemically complex interphases containing both LiF and lithium oxyfluorophosphate species (Li x PO y F z ). Subsequent electrochemical testing shows that vapor-induced passivation layers influence first cycle capacities, lithium (de)insertion overpotentials, and charge-transfer resistance values. In conclusion, these results indicate that vapor–electrode interactions may be a source of variability in electrochemical behavior over time and suggest that other, more reactive electrode materials may also be susceptible to interactions with electrolyte vapor.

36 MATERIALS SCIENCE↗

Dry Deactivation of Sodium Metal in a Molten LiCl-KCl-CsCl-NaCl System

An experimental study was performed with the objective of investigating and characterizing a dry technique for deactivation of sodium metal in a molten salt system. The study was performed in three parts. First, proof-of-principle testing of the technique was performed at bench scale. It involved loading and melting tens of grams of clean sodium metal atop a pool of LiCl-KCl-CsCl eutectic at ∼300°C and then adding ammonium chloride particles while mixing. The ammonium chloride reacted with sodium to form sodium chloride and nitrogen/hydrogen off-gases. The sodium chloride assimilated into the salt pool, forming a quaternary salt mixture of LiCl-KCl-CsCl-NaCl. The proof-of-principle testing repeatedly exhibited complete deactivation of the loaded sodium metal. Second, characterization of a LiCl-KCl-CsCl-NaCl system was performed using differential scanning calorimetry to produce a partial phase diagram of LiCl-KCl-CsCl eutectic versus NaCl, which identified the liquidus, solidus, and two-phase regions of the quaternary system. Third, the dry deactivation technique was demonstrated at kg-scale in an inert atmosphere radiological glovebox with sodium metal that was previously separated in the same glovebox from uranium metal in unirradiated blanket elements for the Fermi-1 nuclear reactor. The quaternary salt product at the end of the demonstration was sampled and showed complete deactivation of the sodium metal. Here, in short, this study qualified a technique to completely deactivate batches of sodium metal in the absence of air or water. While this study focused on the deactivation of sodium metal, including bond sodium from unirradiated blanket elements, the technique is applicable to other sources of sodium metal, such as sodium metal from batteries. Furthermore, the technique could also be extended to other alkali metal systems, including lithium, sodium, potassium, rubidium, cesium, and mixtures thereof.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Laser-Induced Plasmas of Plutonium Dioxide in a Double-Walled Cell

Plutonium research has been stifled by the significant number of administrative controls and safety procedures, space and instrumentation limitations in radiological gloveboxes, and the potential for personnel and equipment contamination. To address the limited number of spectroscopic studies in Pu-bearing compounds in the current scientific literature, this work presents the use of double-walled cells (DWCs) in “clean” buildings/laboratories as an alternative to research in radiological gloveboxes. This study reports the first laser-induced breakdown spectroscopy (LIBS) experiments of a PuO 2 pellet contained within a DWC, where the formation of elemental (atomic and ionic) species as well as the evolution from elemental to molecular products (Pu x O y ) was measured. Raman spectroscopy was also used to characterize the surface of the ablated pellet and the particulates deposited on the window of the inner cell. The full width half-maximum of the T 2g band enabled us to obtain an estimate of the temperature at the pellet surface after the ablation pulse and the particulates based on the crystal lattice disorder. Particulates deposited on the window of the DWC during laser ablation were characterized using scanning electron microscopy, where molten irregular particulates and spheroids were observed. This exciting research conducted in a DWC describes our initial attempts to incorporate LIBS in the arsenal of spectroscopic tools for nuclear forensics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal enhancement cartridge heater modified (TECH Mod) tritium hydride bed development, Part 1 - Design and fabrication

The Savannah River Site (SRS) tritium facilities have used first generation (Gen1) LaNi{sub 4.25}Al{sub 0.75} (LANA0.75) metal hydride storage beds for tritium absorption, storage, and desorption. The Gen1 design utilizes hot and cold nitrogen supplies to thermally cycle these beds. Second and third generation (Gen2 and Gen3) storage bed designs include heat conducting foam and divider plates to spatially fix the hydride within the bed. For thermal cycling, the Gen2 and Gen3 beds utilize internal electric heaters and glovebox atmosphere flow over the bed inside the bed external jacket for cooling. The currently installed Gen1 beds require replacement due to tritium aging effects on the LANA0.75 material, and cannot be replaced with Gen2 or Gen3 beds due to different designs of these beds. At the end of service life, Gen1 bed desorption efficiencies are limited by the upper temperature of hot nitrogen supply. To increase end-of-life desorption efficiency, the Gen1 bed design was modified, and a Thermal Enhancement Cartridge Heater Modified (TECH Mod) bed was developed. Internal electric cartridge heaters in the new design to improve end-of-life desorption, and also permit in-bed tritium accountability (IBA) calibration measurements to be made without the use of process tritium. Additional enhancements implemented into the TECH Mod design are also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal release of {sup 3}He from tritium aged LaNi{sub 4.25}Al{sub 0.75} hydride

The Savannah River Site Tritium Facilities (SRS-TF) utilizes LANA.75 (LaNi{sub 4.25}Al{sub 0.75})in the tritium process to store hydrogen isotopes. The vast majority of {sup 3}He born from the radioactive decay of tritium stored in LANA.75 is trapped in the hydride metal matrix. The SRS-TF has multiple LANA.75 tritium storage beds that have been retired from service with significant quantities of He-3 trapped in the metal. To support He-3 recovery, the Savannah River National Laboratory (SRNL) conducted thermogravimetric analysis coupled with mass spectrometry (TGA-MS) on a tritium aged LANA.75 sample. TGA-MS testing was performed in an argon environment. Prior to testing, the sample was isotopically exchanged with deuterium to reduce residual tritium and passivated with air to alleviate pyrophoric concerns associated with handling the material outside of an inert glovebox. Analyses indicated that gas release from this sample was bimodal, with peaks near 220 and 490 C. degrees. The first peak consisted of both {sup 3}He and residual hydrogen isotopes, the second was primarily {sup 3}He. The bulk of the gas was released by 600 Celsius degrees. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Thermal Processes on Copper‐Tin Alloys for Zinc Gettering

A contamination mitigation plan was initiated to address the discovery of radioactive zinc-65 in a glovebox. A near term solution was developed, installation of heated filters in the glovebox piping. This solution is effective at retaining the zinc in the currently contaminated area, but the gamma emitting contaminant is still present in a system designed for tritium beta. A project was initiated to develop a solution to contain the 65 Zn in the furnace module. Copper and bronze (a Cu/Sn alloy) were found to be candidate materials to combine with zinc-65 vapor, using thermodynamic calculations. A series of binary Cu/Sn alloys were developed (after determining that commercial alloys were unacceptable), that were found to be effective traps of zinc vapor. The task described in this report was undertaken to determine if the bronze substrates would retain their zinc gettering capability after being exposed to simulated extraction conditions with oxidizing and reducing gases. Pure copper and three bronze alloys were prepared, exposed to varying oxidation conditions from 250 to 450°C, then exposed to varying reduction conditions in He-H 2 from 250-450°C, and finally exposed to zinc vapor at 350°C for four hours. The samples were characterized using scanning electron microscopy, X-ray diffraction, differential thermal analysis, mass change, and visual observation. It was observed that the as fabricated samples and the reduced samples all retained their zinc gettering capacity while samples in the "as-oxidized" condition exhibited losses in zinc gettering capacity. Over the range of conditions tested, i.e., composition, oxidation temperature, and reduction temperature, no particular sample composition appeared better. Samples reduced at 350°C exhibited the greatest zinc capacity, although there were some testing anomalies associated with these samples. This work clearly demonstrated that the zinc gettering was not adversely affected by exposure to simulated process conditions and a full scale lithium and zinc trap should be fabricated for testing in the Tritium Extraction Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-faced GRAYQB™: a radiation mapping device

GrayQb{trademark} is a novel technology that has the potential to characterize radioactively contaminated areas such as hot cells, gloveboxes, small and large rooms, hallways, and waste tanks. The goal of GrayQb{trademark} is to speed the process of decontaminating these areas, which reduces worker exposures and promotes ALARA considerations. The device employs Phosphorous Storage Plate (PSP) technology as its primary detector material. PSPs, commonly used for medical applications and non-destructive testing, can be read using a commercially available scanner. The goal of GrayQb{trademark} technology is to locate, quantify, and identify the sources of contamination. The purpose of the work documented in this report was to better characterize the performance of GrayQb{trademark} in its ability to present overlay images of the PSP image and the associated visual image of the location being surveyed. The results presented in this report are overlay images identifying the location of hot spots in both controlled and field environments. The GrayQb{trademark} technology has been mainly tested in a controlled environment with known distances and source characteristics such as specific known radionuclides, dose rates, and strength. The original concept for the GrayQb{trademark} device involved utilizing the six faces of a cube configuration and was designed to be positioned in the center of a contaminated area for 3D mapping. A smaller single-faced GrayQb{trademark}, dubbed GrayQb SF, was designed for the purpose of conducting the characterization testing documented in this report. This lighter 2D version is ideal for applications where entry ports are too small for a deployment of the original GrayQb™ version or where only a single surface is of interest. The shape, size, and weight of these two designs have been carefully modeled to account for most limitations encountered in hot cells, gloveboxes, and contaminated areas. GrayQb{trademark} and GrayQb{trademark} SF share the same fundamental detection system design (e.g., pinhole and PSPs). Therefore, performance tests completed on the single face GrayQB in this report is also applicable to the six- faced GrayQB (e.g., ambient light sensitivity and PSP response). This report details the characterization of the GrayQb{trademark} SF in both an uncontrolled environment; specifically, the Savannah River Site (SRS) Plutonium Fuel Form Facility in Building 235-F (Metallurgical Building) and controlled testing at SRS’s Health Physics Instrument Calibration Facility and SRS’s R&D Engineering Imaging and Radiation Systems Building. In this report, the resulting images from the Calibration Facility were obtained by overlaying the PSP and visual images manually using ImageJ. The resulting images from the Building 235-F tests presented in this report were produced using ImageJ and applying response trends developed from controlled testing results. The GrayQb{trademark} technology has been developed in two main stages at Savannah River National Laboratory (SRNL): 1) the GrayQb{trademark} development was supported by SRNL’s Laboratory Directed Research and Development Program and 2) the GrayQb{trademark} SF development and its testing in Building 235-F were supported by the Office of Deactivation and Decommissioning and Facility Engineering (EM-13), U.S. Department of Energy – Office of Environmental Management.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Re-evaluation of Moisture Controls During ARIES Oxide Processing, Packaging and Characterization

DOE-STD-3013 [1] requires limiting the relative humidity (RH) in the glovebox during processing of the oxide product for specific types of plutonium oxides. This requirement is mandated in order to limit corrosion of the stainless steel containers by deliquescence of chloride salts if present in the PuO2. DOE-STD-3013 also specifies the need to limit and monitor internal pressure buildup in the 3013 containers due to the potential for the generation of free H2 and O2 gas from the radiolysis of surfaceadsorbed water. DOE-STD-3013 requires that the oxide sample taken for moisture content verification be representative of the stabilized material in the 3013 container. This is accomplished by either limiting the time between sampling and packaging, or by control of the glovebox relative humidity (%RH). This requirement ensures that the sample is not only representative, but also conservative from the standpoint of moisture content.

36 MATERIALS SCIENCE↗

Cheesecloth Alternatives Testing

Heat source plutonium oxide (HS-PuO 2 ) enriched with 65% or greater plutonium-238, is recovered and purified using an aqueous nitric acid process. Historically, cheesecloth has been employed for small spill clean-up and for routine housekeeping. However, the 2016 Department of Energy (DOE) Operating Experience report, entitled Nitrate Waste Evaluations, stated that the mixing of nitrate wastes with organic absorbents, such as cheesecloth, may render transuranic waste unacceptable for disposal at WIPP in the future. This report explores the feasibility of replacement of cheesecloth with an alternative sorbent wipe that has similar absorption and cleaning abilities and improved acid resistance. Currently, cheesecloth is used for three different functions in HS-PuO 2 operations: spill cleanup; general housekeeping operations such as cleaning glovebox floors and windows, balances, furnaces, etc.; and decontamination of iridium cladded heat sources containing HS-PuO 2 . Alternatives used for spill cleanup must be able to tolerate high neutron doses found in the HS-Pu gloveboxes. They must also be able to withstand exposure to nitric acid concentrations up to 15.8 M without decomposing. Wipes used for general housekeeping must also be durable enough to clean rough surfaces and remain intact when used for scrubbing. Wipes used for clad decontamination do not need to absorb large amounts of liquid but they must be able to withstand neutron exposures, temperatures of up to several hundred degrees Celsius, and exposure to acid solutions followed by mild scrubbing. Finally wipes used for any purpose must resist chemical reactions with nitric acid that could cause issues for waste disposal such as energetic exothermic reactions or flammable gas build-up. The wipes selected for this study were ranked based on their usability (radiation tolerance, absorbency, integrity in nitric acid, and durability) as well as their chemical compatibility with nitric acid as demonstrated using several types of chemical analyses. Wipes were then ranked based on the combination of their usability and chemical compatibility scores.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuel Fabrication Facility Study for FCF HALEU

Nuclear energy technology developers seek to bring to market new advanced reactor designs and new light water reactor fuel designs, many of which would deploy fuel made from uranium with 235 U enrichment ranging from 5% to 19.75%. There is currently no commercial supply of uranium in this enrichment range, which is higher than used in today’s light water reactors but still lower than the safeguards limit of 20% 235 U. This limitation is a barrier to development of demonstration of these new nuclear energy technologies. As a means to address this near-term need, DOE and Idaho National Laboratory (INL) has considered how the HALEU product from sodium-bonded spent fuel treatment in the INL Fuel Conditioning Facility (FCF), located at the Materials and Fuels Complex (MFC), might be provided and fabricated into some of the new fuel designs. The evaluation presented in this report addresses the potential establishment of two types of fuel fabrication capability at INL, represented generically as a ceramic-type (or pellet-type) fuel fabrication line and a metallic fuel fabrication line. Because the FCF HALEU feedstock contains residual transuranic contamination and a relatively small amount of residual fission products, fabrication with that material is necessarily performed inside of engineered confinement barriers, such as gloveboxes, which would be filled with inert gas for most of the fuel types considered. The throughput rate of the fabrication lines envisioned is 2.5 metric tons of HALEU fuel per year, which is judged to be sufficiently representative of engineering-scale. Space in three existing buildings was identified for consideration in this study of pre-conceptual equipment layouts. The scope and nature of the work needed to prepare each of the three buildings for each type of fuel fabrication was identified (though not in engineering detail), and three-dimensional models of envisioned fabrication equipment were laid out in each of the buildings to assess adequacy of space. The study concluded that either type of fuel fabrication line can feasibly be installed and operated in either of the three buildings. However, each of the three buildings presents different challenges in preparation, due to accommodating current missions that would need to be relocated or necessary decontamination and decommissioning work to free-up space for fuel fabrication, or due to complications of accessibility. Rough order-of-magnitude (ROM) cost estimates for preparing buildings begin at $10M ( 20%/+50%) and would increase with increased complexity of building modifications. The cost of fabrication equipment and gloveboxes is roughly estimated to be $21M (-20%/+50%) for a metallic fuel fabrication line and $27M (-20%/+50%) for a ceramic/intermetallic fuel fabrication line. Nominal operating costs are estimated to be $7M per year (in 2019 dollars), increasing from lower amounts needed as the operating crew is being assembled and trained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operational and Mission Highlights A Monthly Summary of Top Achievements: September 2022

Associate Laboratory Director for Plutonium Infrastructure Mark Anthony and a procurement team visited three glovebox fabricators the week of Aug. 23, 2022, to discuss equipment procurement options and assess the vendors’ production capability, factory conditions, and safety records. The team determined that all three fabricators can produce complex gloveboxes and meet Nuclear Quality Assurance-1 standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Water-Resistant Container Testing CNUT INGB Container Design (Rev. 1)

The purpose of this report is to detail the results of water ingress testing conducted on the 5Qt Castle Nut In-Glovebox (5QtCNUT INGB) container design and discuss these results against the water-resistant container requirements of TA55-AP- 522 and PA-RD-01009. The CNUT is a general-purpose container option for material storage inside of a glovebox and/or as an approved non-hermetically sealed inner of an approved packaging configuration inside of an approved outer container as listed in PA-RD-01022. The CNUT containment boundary consists of a filtered lid and deep drawn body with welded collar all made of 316L stainless steel, an aluminum bronze spin down ring to provide compression of a to Viton® O-ring to create a seal for closure and containment.

36 MATERIALS SCIENCE↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗