Search for gamma-ray point sources
Search for gamma radiation point sources with oriented nuclear emulsions on high altitude balloons
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Search for gamma radiation point sources with oriented nuclear emulsions on high altitude balloons
High altitude balloon magnetic-core digitized spark chamber detector system for determining point sources of cosmic gamma radiation
Ranger iii lunar probe study of gamma radiation from lunar surface
Monte Carlo method for computing particle and gamma radiation transfer for radiation shielding
We have calculated gamma-ray radiative transport in regions of high-energy density, such as gamma-ray burst source regions, using a discrete ordinate, discrete energy group method. The calculations include two-photon pair production and annihilation, as well as three-photon annihilation. The radiation fields itself acts as an absorbing medium, and the optical depth depends on its intensity, so the problem is intrinsically nonlinear. Spherical divergence produces effective collimation of the flux. At high optical depth the high energy (E is greater than 1 MeV) portion of the emergent spectrum assumes a nearly universal form. An approximate limit is derived for the high-energy flux from a gamma-ray burst source region of given size, and the implications of this limit for the distance to the 1979 March 5 event are briefly discussed. We discuss more generally the problem of very luminous bursts, and implications of Galactic halo distances for flare models.
Scintillation counters for measuring gamma radiation of tracers in nuclear reactor shielding studies
The effects of (56)Fe particles and (137)Cs gamma radiation were compared in TK6 and WTK1 human lymphoblasts, two related cell lines which differ in TP53 status and in the ability to rejoin DNA double-strand breaks. Both cell lines were more sensitive to the cytotoxic and clastogenic effects of (56)Fe particles than to those of gamma rays. However, the mutagenicity of (56)Fe particles and gamma rays at the TK locus was the same per unit dose and was higher for gamma rays than for (56)Fe particles at isotoxic doses. The respective RBEs for TK6 and WTK1 cells were 1.5 and 1.9 for cytotoxicity and 2.5 and 1.9 for clastogenicity, but only 1 for mutagenicity. The results indicate that complex lesions induced by (56)Fe particles are repaired less efficiently than gamma-ray-induced lesions, leading to fewer colony-forming cells, a slightly higher proportion of aberrant cells at the first division, and a lower frequency of viable mutants at isotoxic doses. WTK1 cells (mutant TP53) were more resistant to the cytotoxic effects of both gamma rays and (56)Fe particles, but showed greater cytogenetic and mutagenic damage than TK6 cells (TP53(+)). A deficiency in the number of damaged TK6 cells (a) reaching the first mitosis after exposure and (b) forming viable mutants can explain these results.
Cobalt 60 gamma radiation of male white mice to determine ability of auxin and antiviral agents to provide radiation protection
The observations of galactic diffuse gamma radiation are reviewed. The connections of the gamma ray observations with galactic structure and cosmic rays are discussed. The high latitude galactic component and the low latitude emission from the galactic plane are examined. The observations in other regions of the gamma ray spectrum are discussed.
Radiation sensitivity of electronic instruments susceptible to neutron and gamma radiation is evaluated by means of a radioisotope thermoelectric generator /RTG/. The gamma field of the RTG affects instrument operation and requires shielding, the neutron field does not affect operation via secondary capture-gamma production.
A simple code for use in analyses of gamma radiation effects in laminated materials is described. Simple and good geometry is assumed so that all multiple collision and scattering events are excluded from consideration. The code is capable of handling laminates up to six layers. However, for laminates of more than six layers, the same code may be used to incorporate two additional layers at a time, making use of punch-tape outputs from previous computation on all preceding layers. Spectrum of attenuated radiation are obtained as both printed output and punch tape output as desired.
The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.
Gamma-ray telescopes flown on satellites have poor angular resolution with typical point source error circles of a few square degrees. It is shown that a major improvement in angular resolution for the detection of gamma-rays in the GeV region can be obtained with a single crystal as converter. The electron produced by a gamma ray incident at a small angle to a major crystal axis or plane is captured into channeling and radiates gamma rays. The channeling radiation and the electron-positron pair can be detected and yield point source locations with a precision of 5 arcseconds at 10 GeV. This is an improvement of three orders of magnitude on the angular precision of telescopes sensitive to gamma-rays above 50 MeV flown on Satellites.
Co-60 gamma radiation and isochronal annealing temperature effects on minority carrier lifetime of Al and Li doped bulk silicon
The Energetic Gamma Ray Experiment Telescope (EGRET) aboard the Compton Gamma Ray Observatory has detected a high-energy gamma-ray source at a position coincident with that of the radio pulsar PSR 1055-52. Analysis of the EGRET data at the radio pulsar period of 197 ms has revealed pulsed gamma-radiation at energies above 300 MeV, making PSR 1055-52 the fifth detected high-energy gamma-ray pulsar. The pulsed radiation from PSR 1055-52 has a very hard photon spectral index of -1.18 +/- 0.16 and a high efficiency for converting its rotational energy into gamma-rays. No unpulsed emission was observed.
In-vacuo ultraviolet and gamma radiation exposure tests are utilized in a study aimed at the identification of radiation damage mechanisms in composite materials, with the objective of predicting the long-term behavior of composite structures in a space environment at geosynchronous orbit. Physical and chemical methods of polymer characterization are utilized for the study of composite matrix degradation, in conjunction with GC/MS techniques for the analysis of volatile by-products.
The development of degenerative changes in the vasculature, such as atherosclerosis, is a known consequence of exposure to ionizing radiation, and is thus a concern for astronaut health following long duration space flight. Cellular damage caused by radiation is due to free radical generation and DNA damage. The goal of this project was to assess the ability of a C60-derivative, DF-1, to mitigate cellular damage resulting from radiation exposure in primary human lymphocytes. DF-1 is a water-soluble C60 fullerene encapsulated in dendrimeric functional groups that is proposed to exhibit antioxidant properties. Human lymphocytes are radiosensitive and travel throughout the body potentially causing bystander effects in any tissues they contact. These cells were subjected to varying doses of gamma radiation in the presence or absence of DF-1. Cells were collected at 48 hours post-irradiation for chromosomal aberration studies and at 72 hours post-irradiation for micronuclei studies. These studies showed that the irradiated cells contained more chromosomal aberrations and micronuclei than the control cells. Addition of the DF-1 reduced the amount of observed DNA damage in the irradiated cells. Growth curves were measured for the lymphocytes exposed to 0 and 4 Gray gamma irradiations, and we observed less growth in the cells irradiated at 4 Gy. 2,7-dichlorofluorescein diacetate was used to detect reactive oxygen species production, and increased production of ROS was observed in the irradiated lymphocytes. Human lymphocytes were subjected to varying doses of gamma or photon radiation in the presence and absence of DF-1 and a known radioprotectant, amifostine. After irradiation, the production of reactive oxygen species, growth curves and cell viability were measured. These cells were also collected to quantify chromosomal aberrations and micronuclei formation. We predict that irradiated cells will show the most damage and that DF-1 will provide protective effects similar to those of amifostine, an established radioprotectant.
Pathological changes in monkey hypothalamus receiving X and gamma radiation