Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Characterization of a 2D soft x-ray tomography camera with discrimination in energy bands

A gas detector with a 2D pixel readout is proposed for a future soft x-ray (SXR) tomography with discrimination in energy bands separately per pixel. The detector has three gas electron multiplier foils for the electron amplification and it offers the advantage, compared with the single stage, to be less sensitive to neutrons and gammas. The energy resolution and the detection efficiency of the detector have been accurately studied in the laboratory with continuous SXR spectra produced by an electronic tube and line emissions produced by fluorescence (K, Fe, and Mo) in the range of 3-17 keV. The front-end electronics, working in photon counting mode with a selectable threshold for pulse discrimination, is optimized for high rates. The distribution of the pulse amplitude has been indirectly derived by means of scans of the threshold. Scans in detector gain have also been performed to assess the capability of selecting different energy ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Spectrally resolved fluorescence diffuse tomography of biological tissues

Spectrally resolved fluorescence diffuse tomography (SFDT) is demonstrated to be an effective approach to the reconstruction of the fluorescent agent distribution in biological tissues. Analysis of the measured optical power spectrum enables more accurate fluorophore localisation in solving the inverse tomography problem, because the dispersion of the optical parameters of the imaging subject leads to characteristic changes in the shape of its fluorescence spectrum. The SFDT system built by us includes a common optical fibre output of light sources and a single fibre input of the detector in an on-axis configuration, and an electromechanical scanner. The system enables studies of laboratory animals having tumours labelled with various fluorescent agents (fluorescent proteins, quantum dots and others). The first in vivo experiments have demonstrated the feasibility of tumour detection and localisation in laboratory animals by SFDT. (optical tomography)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Scintillating Crystal for High Energy Radiation Detection and Applications

Cesium Hafnium Chloride (Cs2Hfl6) is a promising metal halide scintillating detector due to its excellent characteristics such as non-hygroscopicity, high light yield without doping. Scintillators plays an important role in nuclear security applications as detectors at border monitoring stations. We grew and characterized CHC crystals to be fabricated for gamma detection. Photoluminescence was performed using the Duetta Fluorescence and Absorbance Spectrometer. The energy response to Cs-137 and Co-60 reference sources was recorded for a representative sodium iodide (NaI) scintillating detector.

Reeder, Angel↗

Snapshot 3D tracking of insulin granules in live cells

Rapid and accurate volumetric imaging remains a challenge, yet has the potential to enhance understanding of cell function. We developed and used a multifocal microscope (MFM) for 3D snapshot imaging to allow 3D tracking of insulin granules labeled with mCherry in MIN6 cells. MFM employs a special diffractive optical element (DOE) to simultaneously image multiple focal planes. This simultaneous acquisition of information deteunines the 3D location of single objects at a speed only limited by the array detector's frame rate. We validated the accuracy of MFM imaging/tracking with fluorescence beads; the 3D positions and trajectories of single fluorescence beads can be detelinined accurately over a wide range of spatial and temporal scales. The 3D positions and trajectories of single insulin granules in a 3.2um deep volume were deteunined with imaging processing that combines 3D decovolution, shift correction, and finally tracking using the Imaris software package. We find that the motion of the granules is super diffusive, but less so in 3D than 2D for cells grown on coverslip surfaces, suggesting an anisotropy in the cytoskeleton (e.g. microtubules and action).

3D tracking↗

Airborne Particulate Threat Assessment

Aerosol threat detection requires the ability to discern between threat agents and ambient background particulate matter (PM) encountered in the environment. To date, Raman imaging technology has been demonstrated as an effective strategy for the assessment of threat agents in the presence of specific, complex backgrounds. Expanding our understanding of the composition of ambient particulate matter background will improve the overall performance of Raman Chemical Imaging (RCI) detection strategies for the autonomous detection of airborne chemical and biological hazards. Improving RCI detection performance is strategic due to its potential to become a widely exploited detection approach by several U.S. government agencies. To improve the understanding of the ambient PM background with subsequent improvement in Raman threat detection capability, ChemImage undertook the Airborne Particulate Threat Assessment (APTA) Project in 2005-2008 through a collaborative effort with the National Energy Technology Laboratory (NETL), under cooperative agreement number DE-FC26-05NT42594. During Phase 1 of the program, a novel PM classification based on molecular composition was developed based on a comprehensive review of the scientific literature. In addition, testing protocols were developed for ambient PM characterization. A signature database was developed based on a variety of microanalytical techniques, including scanning electron microscopy, FT-IR microspectroscopy, optical microscopy, fluorescence and Raman chemical imaging techniques. An automated particle integrated collector and detector (APICD) prototype was developed for automated collection, deposition and detection of biothreat agents in background PM. During Phase 2 of the program, ChemImage continued to refine the understanding of ambient background composition. Additionally, ChemImage enhanced the APICD to provide improved autonomy, sensitivity and specificity. Deliverables included a Final Report detailing our findings and APICD Gen II subsystems for automated collection, deposition and detection of ambient particulate matter. Key findings from the APTA Program include: Ambient biological PM taxonomy; Demonstration of key subsystems needed for autonomous bioaerosol detection; System design; Efficient electrostatic collection; Automated bioagent recognition; Raman analysis performance validating Td<9 sec; Efficient collection surface regeneration; and Development of a quantitative bioaerosol defection model. The objective of the APTA program was to advance the state of our knowledge of ambient background PM composition. Operation of an automated aerosol detection system was enhanced by a more accurate assessment of background variability, especially for sensitive and specific sensing strategies like Raman detection that are background-limited in performance. Based on this improved knowledge of background, the overall threat detection performance of Raman sensors was improved.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Upper bound and probable value of the rate constant of the reaction OH + HO2 yields H2O + O2

Discharge-flow experiments at 295 K of the OH + HO2 reaction are described in which excess O3 is added to OH through a movable injector; OH concentration is measured downstream by resonance fluorescence with and without addition of excess NO just upstream of the detector so that both OH concentration and OH concentration + HO2 concentration are determined independently. The data are compared with a computer model involving 12 reaction steps. A simple sensitivity analysis is carried out to establish how errors in the other 'known' rate constants affect the data fit. Best agreement is obtained between computer calculations and experiments when k1 for the OH + HO2 reaction is in the range 2-3 x 10 to the -11th cu cm/s. Values above about 5 x 10 to the -11th are very unlikely whereas those below about 1 x 10 to the -11th are less strongly excluded.

Chang, J. S.↗

Improved Optical-Fiber Temperature Sensors

In optical-fiber temperature sensors of proposed type, phosphorescence and/or fluorescence in temperature-dependent coating layers coupled to photodetectors. Phosphorescent and/or fluorescent behavior(s) of coating material(s) depend on temperature; coating material or mixture of materials selected so one can deduce temperature from known temperature dependence of phosphorescence and/or fluorescence spectrum, and/or characteristic decay of fluorescence. Basic optical configuration same as that of optical-fiber chemical detectors described in "Making Optical-Fiber Chemical Detectors More Sensitive" (LAR-14525).

Rogowski, Robert S.↗

A Spectrographic Receiver for Laser Spectrometers

Multiband LiDAR systems, which are typically single wavelength in transmission and reception, are becoming more applicable for scientific use. However, traditional LiDAR receivers do not scale well to tens or hundreds of received bands. We introduce the design for a spectrographic receiver using an array detector for laser spectrometers and present two of the many possible applications: fluorescence spectroscopy in the visible range and IR reflectance spectroscopy. Each laser pulse has the capability of exciting a target in various wavelengths, and a spectrographic receiver would be able to interpret this excitation, while a typical LiDAR consisting of single wavelength receiver would not. Using a spectrograph in a system with a pulsed laser in the visible or UV range is capable of the detection of fluorescent signal. These spectra reveal the presence of organics and is an applicable technology for planetary science. A spectrograph coupled with a pulsed laser in the IR range shows capability of detecting the presence of water in various forms also applicable technology for both Earth and planetary science. Both systems utilize a Czerny-Turner spectrograph design with a ZnSe prism for the dispersion of light onto an Avalanche Photo Diode (APD). This paper introduces the concept and design of a spectrographic receiver for laser spectrometers, as well as two possible applications.

Sandford, Macey↗

The Cosmic Ray Energy Spectrum and Related Measurements with the Pierre Auger Observatory

These are presentations to be presented at the 31st International Cosmic Ray Conference, in Lodz, Poland during July 2009. It consists of the following presentations: (1) Measurement of the cosmic ray energy spectrum above 10{sup 18} eV with the Pierre Auger Observatory; (2) The cosmic ray flux observed at zenith angles larger than 60 degrees with the Pierre Auger Observatory; (3) Energy calibration of data recorded with the surface detectors of the Pierre Auger Observatory; (4) Exposure of the Hybrid Detector of The Pierre Auger Observatory; and (5) Energy scale derived from Fluorescence Telescopes using Cherenkov Light and Shower Universality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated ultrasonic particle positioning and low excitation light fluorescence imaging

A compact hybrid system has been developed to position and detect fluorescent micro-particles by combining a Single Photon Avalanche Diode (SPAD) imager with an acoustic manipulator. The detector comprises a SPAD array, light-emitting diode (LED), lenses, and optical filters. The acoustic device is formed of multiple transducers surrounding an octagonal cavity. By stimulating pairs of transducers simultaneously, an acoustic landscape is created causing fluorescent micro-particles to agglomerate into lines. The fluorescent pattern is excited by a low power LED and detected by the SPAD imager. Our technique combines particle manipulation and visualization in a compact, low power, portable setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

Response of a hybrid pixel detector (MEDIPIX3) to different radiation sources for medical applications

The development in semiconductor CMOS technology has enabled the creation of sensitive detectors for a wide range of ionizing radiation. These devices are suitable for photon counting and can be used in imaging and tomography X-ray diagnostics. The Medipix[1] radiation detection system is a hybrid silicon pixel chip developed for particle tracking applications in High Energy Physics. Its exceptional features (high spatial and energy resolution, embedded ultra fast readout, different operation modes, etc.) make the Medipix an attractive device for applications in medical imaging. In this work the energy characterization of a third-generation Medipix chip (Medipix3) coupled to a silicon sensor is presented. We used different radiation sources (strontium 90, iron 55 and americium 241) to obtain the response curve of the hybrid detector as a function of energy. We also studied the contrast of the Medipix as a measure of pixel noise. Finally we studied the response to fluorescence X rays from different target materials (In, Pd and Cd) for the two data acquisition modes of the chip; single pixel mode and charge summing mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subdiffraction instrumentation development and application to the elucidation of biological systems, thin films, and organic photovoltaic devices

Fluorescence and Raman instrumentation was developed to elucidate morphology, information on local environment, and material properties of target systems. Far-field fluorescence and luminescence spectroscopic measurements were performed using a pulsed super-continuum laser source and detector with high temporal resolution. With this arrangement morphologies of structures were coupled with time-correlated data. Polymeric beads and Alexa Fluor 594-phalloidin labeled cellular actin structures of cultured cells were imaged below the diffraction limit using stimulated emission depletion to resolve structures to ≈40nm. Lifetime imaging revealed a 2.0 ± 0.1 ns lifetime for fluorescently-labeled beads in confocal and depletion imaging modes. Depletion imaging was also able to display a change of 2.2 to 2.9 ns for different regions of the cellular actin network of cultured cells with a possible difference in lifetime caused by tryptophan quenching of the dye. Subdiffraction imaging with a resolution of ≈40 nm was also accomplished using luminescence depletion of photostable giant CdSe/14CdS nanocrystal quantum dots in air. Nanocrystal quantum dots, typically not prone to depletion, exhibited this phenomenon when excited with an energy of 50 pJ and 2 nJ of depletion energy. Luminescence depletion required half the energy compared to stimulated emission depletion to achieve the same resolution limit. The luminescence was depleted by as much as ≈92% with no observable photobleaching. Raman measurements of polymer films were performed with 532-nm laser illumination using scanning angle and conventional 180° backscattering modes to determine chemical information. The scanning angle mode achieved an angle resolution of 0.09° and was used to probe a thin layer of polystyrene as well as a diblock copolymer of polystyrene and poly(3-hexylthiophene-2,5-diyl). Enhancements to the Raman signals at selected angles lower than the critical angle for total internal reflection, characteristic of waveguides, were measured. An additional enhancement in the Raman signal results from resonant conditions for the diblock copolymer. The epi-collection geometry was used to gain spectroscopic information regarding to the stability of heterojunction solar cells with the aid of resonance Raman spectroscopy. Raman spectral characteristics corresponding to thiophene-based functional groups were used to relate stability of the polymers under different processing conditions such as solvent and thermal annealing while undergoing laser induced photodegradation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues--Preliminary Results

Manganese (Mn) is not abundant in human brain tissue, but it is recognized as a neurotoxin. The symptoms of manganese intoxication are similar to Parkinson's disease (PD), but the link between environmental, occupational or dietary Mn exposure and PD in humans is not well established. X-ray Absorption Spectroscopy (XAS) and in particular X-ray fluorescence can provide precise information on the distribution, concentration and chemical form of metals. However the scattered radiation and fluorescence from the adjacent abundant element, iron (Fe), may interfere with and limit the ability to detect ultra-dilute Mn. A bent Laue analyzer based Mn fluorescence detection system has been designed and fabricated to improve elemental specificity in XAS imaging. This bent Laue analyzer of logarithmic spiral shape placed upstream of an energy discriminating detector should improve the energy resolution from hundreds of eV to several eV. The bent Laue detection system was validated by imaging Mn fluorescence from Mn foils, gelatin calibration samples and adult Drosophila at the Hard X-ray MicroAnalysis (HXMA) beamline at the Canadian Light Source (CLS). Optimization of the design parameters, fabrication procedures and preliminary experimental results are presented along with future plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗