Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Faulting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Long–short-term memory encoder–decoder with regularized hidden dynamics for fault detection in industrial processes

The ability of recurrent neural networks (RNN) to model nonlinear dynamics of high dimensional process data has enabled data-driven RNN-based fault detection algorithms. Previous studies have focused on detecting faults by identifying the discrepancies in data distribution between the faulty and normal data, as reflected in prediction errors generated by RNN models. However, in industrial processes, variations in data distribution can also result from changes in normal control setpoints and compensatory control adjustments in response to disturbances, making it hard to differentiate between normal and faulty conditions. This paper proposes a fault detection method utilizing a long short-term memory (LSTM) encoder–decoder structure with regularized hidden dynamics and reversible instance normalization (RevIN) to compactly represent high-dimensional measurements for effective monitoring. During training, the hidden states of the model are regularized to form a low-dimensional latent space representation of the original multivariate time series data. As a result, the prediction errors of the latent states can be used to monitor the abnormal dynamic variations, while the reconstruction errors of the measured variables are used to monitor the abnormal static variations. Furthermore, the proposed indices can reflect operating conditions, even when the distribution of test data changes, which helps distinguish faults from normal adjustments and disturbances that controllers can settle. Here, data from numerical simulation and the Tennessee Eastman process are used to illustrate the effectiveness of the proposed fault detection method.

42 ENGINEERING↗

The influence of stacking faults on mechanical behavior of advanced materials

We report there are abundant studies on deformation mechanisms in metallic materials dominated by grain boundaries and twin boundaries. In comparison, the influence of stacking faults on deformation mechanisms of materials remains less well understood. Recent studies have shown that when the density of stacking faults increases sharply, their influence on mechanical behavior of metallic or ceramic materials becomes prominent, and in fact, dominates in some cases. This article reviews recent research progress on how nanoscale stacking faults impact the mechanical behavior of metallic and ceramic materials. We primarily focus on studies that reveal the formation of pre-existing stacking faults, their interactions with dislocations, and phase transformations during plastic deformation as evidenced by experiments and simulations. The aim of this review is to highlight the potential opportunities in using stacking faults to tailor the deformation mechanisms of advanced materials.

36 MATERIALS SCIENCE↗

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

Convolutional Neural Network-Based Protection-Zone Classification of Faults in Distribution Feeders with Photovoltaics.

Fault detection and isolation is critical for reliable operation of distribution systems. The ride-through requirements for the distributed energy resources (DER), mandated by the IEEE 1547-2018 standard, makes it challenging to use undervoltage (UV) conditions for fault detection. In addition, with low fault current contribution from these inverter-based DERs, the time-overcurrent relays are also less effective. Thus motivated, this paper presents a learning-based approach for fault detection and localization. A convolutional neural network (CNN)-based model is proposed which uses local voltage and current waveforms from DER locations and feeder substations, for training a zonal classifier. The classifier can be adopted into any relay-like device for discriminating between faults originating from different protection zones. The performance of the proposed approach was tested on publicly available test feeders with distributed photovoltaics (PVs).

Fault localization, convolutional neural networks,↗

Rotor Magnet Fault Analysis in Permanent Magnet AC Machines Under Load Conditions - All Electric Transportation Systems

This paper studies the performance of a Permanent Magnet (PM) alternating-current (AC) machine when subjected to faults under load conditions. The effect of varying load torques, and unbalances are found to be potential causes of rotor faults, inducing physical magnet defects or broken rotor-PMs. The consequent and immediate impact on the machine quantities is observed through anomalous change in torque-speed characteristics and other vital signatures such as machine back-EMF/flux and motor current signatures (MCS). The present research study develops and illustrates a method to diagnose physical magnet defects (fault) in PMAC machines by estimating the machine torque/back-EMF constant, Ke. The constant Ke is a measure of magnet strength exhibiting the health of rotor PMs, indicative of faults. Advanced research studies and investigations are carried out to establish motor approximations and signature-based analysis as significant viable tools for diagnosing machine faults even under load conditions.

alternating current↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of fault related voltage swell on distribution feeders using DER-based advanced inverter controls

Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.

14 SOLAR ENERGY↗

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance assessment of near-fault buildings subjected to physics-based simulated earthquake ground motions with fling step

The effects of the co-seismic static offset (known as fling step) and associated velocity pulses on civil structures have been difficult to study because the static offset is typically removed during the processing of earthquake ground motion records. Simulated ground motions contain fling features and require no processing; therefore, they create new opportunities for representing fling features in seismic hazard analysis and assessing their influence on the seismic demands on near-fault structures. We use physics-based fault rupture simulations to study the characteristics of ground motions with fling step and the sensitivity of the near-fault structural demands to strong fling features. We uncover that simulated ground motions with a large fling step tend to have higher spectral intensity than those without a fling step at the same rupture distance, especially at periods longer than 2 s. As a result, the structural demands on flexible buildings tend to be the most sensitive to the fling features. Statistical analysis suggests that the ground motion spectral shape (represented by spectral accelerations at multiple periods) is—in most cases—a sufficient predictor of the structural demands on near-fault low-rise and mid-rise buildings at locations that are susceptible to strong fling effects. Finally, ground motion record selection experiments reveal that representing the spectral shape features at periods that are most relevant to a given structure may be an effective strategy to reduce the bias in the estimated demands on near-fault long-period structures when the available database of records is considered deficient in fling features.

Fling step↗

Evidence for a Single Holocene Paleoseismic Event on the Pajarito Fault, Northern New Mexico

Low-slip rate fault systems tend to be less studied than their high-slip rate counterparts, and paleoseismic techniques used to study them may pose challenges in interpretation that differ from high-slip rate systems. A good example of this is the Pajarito fault system (PFS), a normal fault complex within the Rio Grande rift. Despite numerous previous paleoseismic trenching studies conducted on the PFS between 1990 and 2003, considerable uncertainty remains regarding its Holocene paleoseismic history, particularly for the primary Pajarito fault (PF). To further clarify the PF paleoseismic history, we present data from paleoseismic investigations of 6 trenches at 3 distinct locations along the PF. Though the totality of the age and structural data obtained in this study is complex and not entirely consistent with any one interpretation, a single Holocene paleoearthquake occurring younger than ∼1,600 to 2,300 kcal yr BP is the simplest interpretation. It is possible that the PF records two Holocene events, with a penultimate event 6.9–2.4 kcal yr BP event and the aforementioned most recent event (MRE) between 2.3 and 1.6 kcal yr BP. However, only a single wall of one trench, out of a total of 12 walls in our 6 trenches, provides evidence supporting that interpretation. This study finds evidence of a single late Holocene paleoseismic event on the PF and sparse evidence for 2 Holocene paleoseismic events on the PF and highlights the benefits of logging multiple trench walls to better understand the complexity that results from this low-slip rate, low-deposition-rate fault system.

58 GEOSCIENCES↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Learning Based Superconducting Radio-Frequency Cavity Fault Classification at Jefferson Laboratory

This work investigates the efficacy of deep learning (DL) for classifying C100 superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a large, high-power continuous wave recirculating linac that utilizes 418 SRF cavities to accelerate electrons up to 12 GeV. Recent upgrades to CEBAF include installation of 11 new cryomodules (88 cavities) equipped with a low-level RF system that records RF time-series data from each cavity at the onset of an RF failure. Typically, subject matter experts (SME) analyze this data to determine the fault type and identify the cavity of origin. This information is subsequently utilized to identify failure trends and to implement corrective measures on the offending cavity. Manual inspection of large-scale, time-series data, generated by frequent system failures is tedious and time consuming, and thereby motivates the use of machine learning (ML) to automate the task. This study extends work on a previously developed system based on traditional ML methods (Tennant and Carpenter and Powers and Shabalina Solopova and Vidyaratne and Iftekharuddin, Phys. Rev. Accel. Beams, 2020, 23, 114601), and investigates the effectiveness of deep learning approaches. The transition to a DL model is driven by the goal of developing a system with sufficiently fast inference that it could be used to predict a fault event and take actionable information before the onset (on the order of a few hundred milliseconds). Because features are learned, rather than explicitly computed, DL offers a potential advantage over traditional ML. Specifically, two seminal DL architecture types are explored: deep recurrent neural networks (RNN) and deep convolutional neural networks (CNN). We provide a detailed analysis on the performance of individual models using an RF waveform dataset built from past operational runs of CEBAF. In particular, the performance of RNN models incorporating long short-term memory (LSTM) are analyzed along with the CNN performance. Furthermore, comparing these DL models with a state-of-the-art fault ML model shows that DL architectures obtain similar performance for cavity identification, do not perform quite as well for fault classification, but provide an advantage in inference speed.

97 MATHEMATICS AND COMPUTING↗

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators: Preprint

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. The underlying idea behind traditional indicators often revolves around tracking both cyclostationarity and abnormal impulses in the vibration signals without distinguishing the two. A recently proposed method to capture the rolling element bearing degradation lays out the groundwork for new indicator families utilizing generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the NREL Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox, hence the complexity of the vibration signals is similar to a real case. Furthermore, the new indicators are also tested with signals that carry multiple fault signatures. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗

Decentralized Microgrid Protection Through Relative Fault Direction Classification: Preprint

Protection in inverter-based resources (IBRs) dominated microgrids generally face significant challenges due to the low fault current and inconsistent fault behaviors from IBRs. Recently, machine learning-based approaches have attracted considerable attention to address these challenges. This paper introduces a novel decentralized protection strategy for microgrids. The proposed method decomposes the protection challenge into several distributed learning tasks, enabling individual relays to autonomously determine the direction of faults using a binary classification framework based on support vector machine (SVM) algorithms. Following the distributed fault direction estimation, classifier outcomes are shared among neighboring relays, facilitating a local decision-making process to ascertain the presence of faults within the neighborhood. Finally, a tripping signal is generated based on the classifier results of each relay to operate the circuit breaker. To test and validate this approach, a 100% renewable microgrid model is simulated in MATLAB/Simulink. In the numerical analysis, the application of SVM classifiers in our approach yields impressive results: an average relay classification accuracy of 98%, and a 96% accuracy in circuit breaker control. These findings highlight the potential of machine-learning-based approaches in enhancing the efficiency and reliability of microgrid protection systems.

decentralized algorithm↗

Information Leakage Analysis using a Co-design-Based Fault Injection Technique on a RISC-V Microprocessor

The RISC-V instruction set architecture open licensing policy has spawned a hive of development activity, making a range of implementations publicly available. The environments in which RISC-V operates have expanded correspondingly, driving the need for a generalized approach to evaluating the reliability of RISC-V implementations under adverse operating conditions or after normal wear-out periods. Fault injection (FI) refers to the process of changing the state of registers or wires, either permanently or momentarily, and then observing execution behavior. The analysis provides insight into the development of countermeasures that protect against the leakage or corruption of sensitive information which might occur because of unexpected execution behavior. In this paper, we develop a hardware-software co-design architecture that enables fast, configurable fault emulation and utilize it for information leakage and data corruption analysis. Modern System-on-chip FPGAs enable building an evaluation platform where control elements run on a processor(s) (PS) simultaneously with the target design running in the programmable logic (PL). Software components of the FI system introduce faults and report execution behavior. A pair of RISC-V FI-instrumented implementations are created and configured to execute the Advanced Encryption Standard and Twister algorithms. Key and plaintext information leakage and degraded pseudo-random sequences are both observed in the output for a subset of the emulated faults.

42 ENGINEERING↗

Machine-learning-aided density functional theory calculations of stacking fault energies in steel

A combined large-scale first principles approach with machine learning and materials informatics is proposed to quickly sweep the chemistry-composition space of advanced high strength steels (AHSS). AHSS are composed of iron and key alloying elements such as aluminum and manganese. A systematic exploration of the distribution of aluminum and manganese atoms in iron is used to investigate low stacking fault energies configurations using first principles calculations. To overcome the computational cost of exploring the composition space, this process is sped up using an automated machine learning tool: DeepHyper. Here our results predict that it is energetically favorable for Al to stay away from a stacking fault, but Mn atoms do not affect the stacking fault energy and can stay in the vicinity of the fault. The distribution of Al and Mn atoms in systems containing stacking faults and the effects of their interactions on the equilibrium distribution are systematically analyzed.

36 MATERIALS SCIENCE↗

Atomic Structural Features of Stacking Faults and Domain Connections in the Li- and Mn-Rich Cathode

Li- and Mn-rich layered oxides (LMRs), a class of earth-abundant materials for rechargeable Li-ion battery cathodes, crystallize into layered structures of two different symmetries: C2/m represented by Li 2 MnO 3 and R$\overline{3}$m represented by LiMn 0.5 Ni 0.5 O 2 . Fundamental questions about how the C2/m and R$\overline{3}$m domains spatially correlate within the same oxide grain and how the C2/m stacking faults arrange themselves when this happens still remain. Here, by using integrated differential phase contrast imaging in scanning transmission electron microscopy (STEM-iDPC), we probe the structural and compositional details of a prototypical, cobalt-free LMR material, 0.3Li 2 MnO 3 •0.7LiMn 0.5 Ni 0.5 O 2 (Li 1.13 Mn 0.57 Ni 0.3 O 2 ). The connection between the C2/m and R$\overline{3}$m domains is found to be abrupt, facilitated by the small lattice mismatch between the two structures. Stacking faults in the C2/m domains feature atomic plane shifting that accommodates stacking sequence changes, which explains why the stacking faults form in a random manner. Furthermore, a local disordering mechanism was identified to correlate with the C2/m stacking faults. Chemically, it is found that Ni coexists with Mn at the transition metal sites within the nominal Li 2 MnO 3 domain. As a result, this study demonstrates that STEM-iDPC is a very useful tool for capturing all the elements in a single image, revealing atomic details on domain connections and stacking faults in the LMRs.

Li-rich and Mn-rich oxides↗