Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Hypervelocity impact testing of tethers

An experimental test program has been conducted to ascertain the strength losses to which representative space tether materials may be prone upon impact by hypervelocity particles of known size, density, and velocity, when the tether is under tensile loading typical of flight design loads. Twelve hypervelocity impacts were followed by tensile tests to failure to determine residual strength; relationships are established between particle velocity and strength loss due to impact damage, as well as between tether strength loss and the relationship between particle and tether diameters. Tentative design criteria are formulated in terms of a design factor allowing for strength degradation by impact.

Woodis, William R.↗

CFD Modeling of Sodium-Oxide Deposition in Sodium-Cooled Fast Reactor Compact Heat Exchangers

The possible use of compact heat exchangers (HXs) in sodium-cooled fast reactors (SFR) employing a Brayton cycle is promising due to their high power density and resulting small volume in comparison with conventional shell-and-tube HXs. However, the small diameter of their channels makes them more susceptible to plugging due to Na2O deposition during accident conditions. Although cold traps are designed to reduce oxygen impurity levels in the sodium coolant, their failure, in conjunction with accidental air ingress into the sodium boundary, could result in coolant oxygen levels that are above the saturation limit in the cooler parts of the HX channels. This can result in Na2O crystallization and the formation of solid deposits on cooled channel surfaces, limiting or even blocking coolant flow. The development of analysis tools capable of modeling the formation of these deposits in the presence of sodium flow will allow designers of SFRs to properly size the HX channels so that, in the scenario mentioned above, the reactor operator has sufficient time to detect and react to the affected HX. Until now, analytical methodologies to predict the formation of these deposits have been developed, but never implemented in a high-fidelity computational tool suited to modern reactor design techniques. This paper summarizes the challenges and the current status in the development of a Computational Fluid Dynamics (CFD) methodology to predict deposit formation, with particular emphasis on sensitivity studies on some parameters affecting deposition.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characteristics of Whipple Shield Performance in the Shatter Regime

Between the onset of projectile fragmentation and the assumption of rear wall failure due to an impulsive load, multi-wall ballistic limit equations are linearly interpolated to provide reasonable yet conservative predictions of perforation thresholds with conveniently simple mathematics. Although low velocity and hypervelocity regime predictions are based on analytical expressions, there is no such scientific foundation for predictions in the intermediate (or shatter) regime. As the debris flux in low earth orbit (LEO) becomes increasingly dominated by manmade pollution, the profile of micrometeoroid and orbital debris (MMOD) risk shifts continually towards lower velocities. For the International Space Station (ISS), encounter velocities below 7 km/s now constitute approximately 50% of the penetration risk. Considering that the transition velocity from shatter to hypervelocity impact regimes described by common ballistic limit equations (e.g. new non-optimum Whipple shield equation [1]) occurs at 7 km/s, 50% of station risk is now calculated based on failure limit equations with little analytical foundation. To investigate projectile and shield behavior for impact conditions leading to projectile fragmentation and melt, a series of hypervelocity impact tests have been performed on aluminum Whipple shields. In the experiments projectile diameter, bumper thickness, and shield spacing were kept constant, while rear wall thickness was adjusted to determine spallation and perforation limits at various impact velocities and angles. The results, shown in Figure 1 for normal and 45 impacts, demonstrated behavior that was not sufficiently described by the simplified linear interpolation of the NNO equation (also shown in Figure 1). Hopkins et al. [2] investigated the performance of a nominally-identical aluminum Whipple shield, identifying the effects of phase change in the shatter regime. The results (conceptually represented in Figure 2) were found to agree well with those obtained in this study at normal incidence, suggesting that shielding performance in the shatter regime could be well described by considering more complex phase conditions than currently implemented in most BLEs. Furthermore, evidence of these phase effects were found in the oblique test results, providing the basis for an empirical description of these effects that can be applied in MMOD risk assessment software. In this paper, results of the impact experiments are presented, and characteristics of target damage are evaluated. A comparison of intermediate velocity impact failure mechanisms in current BLEs are discussed and compared to the findings of the experimental study. Risk assessment calculations have been made on a simplified structure using currently implemented penetration equations and predicted limits from the experimental program, and the variation in perceived mission risk is discussed. It was found that ballistic limit curves that explicitly incorporated phase change effects within the intermediate regime lead to a decrease in predicted MMOD risk for ISS-representative orbits. When considered for all Whipple-based shielding configurations onboard the ISS, intermediate phase change effects could lead to significant variations in predicted mission risk.

Ryan, Shannon↗

Modern methodology of designing target reliability into rotating mechanical components

Experimentally determined distributional cycles-to-failure versus maximum alternating nominal strength (S-N) diagrams, and distributional mean nominal strength versus maximum alternating nominal strength (Goodman) diagrams are presented. These distributional S-N and Goodman diagrams are for AISI 4340 steel, R sub c 35/40 hardness, round, cylindrical specimens 0.735 in. in diameter and 6 in. long with a circumferential groove 0.145 in. radius for a theoretical stress concentration = 1.42 and 0.034 in. radius for a stress concentration = 2.34. The specimens are subjected to reversed bending and steady torque in specially built, three complex-fatigue research machines. Based on these results, the effects on the distributional S-N and Goodman diagrams and on service life of superimposing steady torque on reversed bending are established, as well as the effect of various stress concentrations. In addition a computer program for determining the three-parameter Weibull distribution representing the cycles-to-failure data, and two methods for calculating the reliability of components subjected to cumulative fatigue loads are given.

Kececioglu, D. B.↗

Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems

The project “Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems” was conducted jointly by Westinghouse Electric Company (Westinghouse) and Argonne National Laboratory (ANL), over the period October 1, 2013- March 31, 2016. The project’s motivation was the need to provide designers of Sodium Fast Reactors (SFRs) with a validated, state-of-the-art computational tool for the prediction of sodium oxide (Na 2 O) deposition in small-diameter sodium heat exchanger (HX) channels, such as those in the diffusion bonded HXs proposed for SFRs coupled with a supercritical CO 2 (sCO 2 ) Brayton cycle power conversion system. In SFRs, Na 2 O deposition can potentially occur following accidental air ingress in the intermediate heat transport system (IHTS) sodium and simultaneous failure of the IHTS sodium cold trap. In this scenario, oxygen can travel through the IHTS loop and reach the coldest regions, represented by the cold end of the sodium channels of the HXs, where Na 2 O precipitation may initiate and continue. In addition to deteriorating HX heat transfer and pressure drop performance, Na 2 O deposition can lead to channel plugging especially when the size of the sodium channels is small, which is the case for diffusion bonded HXs whose sodium channel hydraulic diameter is generally below 5 mm. Sodium oxide melts at a high temperature well above the sodium melting temperature such that removal of a solid plug such as through dissolution by pure sodium could take a lengthy time. The Sodium Plugging Phenomena Loop (SPPL) was developed at ANL, prior to this project, for investigating Na 2 O deposition phenomena within sodium channels that are prototypical of the diffusion bonded HX channels envisioned for SFR-sCO 2 systems. In this project, a Computational Fluid Dynamic (CFD) model capable of simulating the thermal-hydraulics of the SPPL test section and provided with Na 2 O deposition prediction capabilities, was developed. This state-of-the-art computational tool incorporates a first-principles Na 2 O deposition model developed by ANL, and combines it with predictive capabilities for the spatial and temporal variation of temperature, velocity, dissolved oxygen concentration, and wall temperature under flowing sodium conditions. The CFD model was validated under no-deposition conditions using experimental data collected with the SPPL, demonstrating the model’s capability to predict the thermal-hydraulics of the SPPL test section within the measurement uncertainty characterizing the SPPL instrumentation. The model’s deposition prediction capability was not, however, validated as the SPPL could not be operated under plugging conditions during the project, resulting in the lack of deposition data with adequate pedigree for a CFD model validation. Two novel diagnostic techniques to detect and characterize Na 2 O deposits, i.e. Ultrasonic Time Domain Reflectometry (UTDR) and Potential Drop (PD) techniques, were developed to ultimately assist in the validation effort under plugging conditions, which can be performed once the SPPL becomes operational. This development effort consisted first in demonstrating, analytically and/or computationally, the capability of these techniques to diagnose Na 2 O deposits inside of small channels (particularly the deposit’s thickness), and subsequently in the fabrication and testing of prototypical UTDR and PD instrumentation. The testing, performed on mockups of the SPPL test section, demonstrated the capability of these techniques to detect and characterize material discontinuities like those induced by sodium oxide deposition on stainless steel channel walls. Because of the mentioned impossibility to run the SPPL in a plugging mode, the developed instrumentation could not be tested in-situ, i.e. at the SPPL while deposits are being formed inside of the SPPL test section. Recommended future work includes a possible enhancement in the CFD modeling technique and installation of the developed UTDR and PD instrumentation on the test section, followed by plugging tests to be conducted with the SPPL. The installation of the UTDR and PD diagnostic instrumentation on the SPPL test section will allow collection of Na 2 O deposition data after the onset of deposition to nearly complete channel plugging, which can ultimately be used for the validation of the CFD model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Seismic response of offshore wind turbine with hybrid monopile foundation based on centrifuge modelling

Some large capacity offshore wind turbines are constructed in seismically active areas. The occurrence of soil liquefaction during an earthquake can result in severe failures of the offshore wind turbine. The seismic response of the structure and the failure mechanism of the soil-structure interactions are necessary to investigate. In this study, the seismic response of an innovative hybrid monopile foundation is investigated through a series of centrifuge tests. The seismic performance of the combined system of the superstructure, foundation, and soil are demonstrated. Five hybrid foundation models are tested by considering the influence of the foundation thicknesses and diameters, and a monopile foundation is tested for comparison. Centrifuge test results reveal that the hybrid monopile foundation is effective in reducing the lateral displacement during the shaking. In the saturated condition, soil maintains its strength and stiffness beneath and adjacent to the foundation. The hybrid foundation system tends to settle more due to the larger shear stress caused by the soil structure interactions. Influences of the wheel specifications are illustrated. The foundations with larger thicknesses lead to smaller lateral displacements and lower tendencies of liquefaction, but the settlements are intensified. The larger diameter foundation provides a longer drainage path for the excess pore water pressure. With a similar weight, the structure settles less during the earthquake.

17 WIND ENERGY↗

Torus CLAS12-Superconducting Magnet Quench Analysis

The JLAB Torus magnet system consists of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration. These coils are wound with SSC-36 Nb-Ti superconductor and have the peak magnetic field of 3.6 T. The first coil manufacturing based on the JLAB design began at FNAL. The large magnet system dimensions (8 m diameter and 14 MJ of stored energy) dictate the need for quench protection. Each coil is placed in an aluminum case mounted inside a cryostat and cooled by 4.6 K supercritical helium gas flowing through a copper tube attached to the coil ID. The large coil dimensions and small cryostat thickness drove the design to challenging technical solutions, suggesting that Lorentz forces due to transport currents and eddy currents during quench and various failure scenarios are analyzed. The paper covers the magnet system quench analysis using the OPERA3d Quench code.

Kashikhin, V S↗

AGR-5/6/7 Irradiation Test Predictions using PARFUME

PARFUME, (PARticle FUel ModEl) a fuel performance modeling code used for high temperature gas-cooled reactors (HTGRs), was used to model the Advanced Gas Reactor (AGR)-5/6/7 irradiation test using predicted physics and thermal hydraulics data. The AGR-5/6/7 test consists of the combined fifth, sixth, and seventh planned irradiations of the AGR Fuel Development and Qualification Program. The AGR-5/6/7 test train is a multi-capsule, instrumented experiment that is designed for irradiation in the 133.4-mm diameter north east flux trap (NEFT) position of Advanced Test Reactor (ATR). Each capsule contains compacts filled with uranium oxycarbide (UCO) unaltered fuel particles. This report documents the calculations performed to predict the failure probability of tristructural isotropic (TRISO)-coated fuel particles during the AGR-5/6/7 experiment. In addition, this report documents the calculated source term from the driver fuel. The calculations include modeling of the AGR-5/6/7 irradiation that is scheduled to occur from October 2017 to April 2021 over a total of 13 ATR cycles, including nine normal cycles and four Power Axial Locator Mechanism (PALM) cycle for a total between 500 – 550 effective full power days (EFPD). The irradiation conditions and material properties of the AGR-5/6/7 test predicted zero fuel particle failures in Capsules 1, 2, and 4. Fuel particle failures were predicted in Capsule 3 due to internal particle pressure. These failures were predicted in the highest temperature compacts. Capsule 5 fuel particle failures were due to inner pyrolytic carbon (IPyC) cracking causing localized stresses concentrations in the SiC layer. This capsule predicted the highest particle failures due to the lower irradiation temperature. In addition, shrinkage of the buffer and IPyC layer during irradiation resulted in formation of a buffer-IPyC gap. The two capsules at the two ends of the test train, Capsules 1 and 5 experienced the smallest buffer-IPyC gap formation due to the lower irradiation fluences and temperatures. Capsule 3 experienced the largest buffer-IPyC gap formation of just under 24 µm. The release fraction of fission products Ag, Cs, and Sr silver (Ag), cesium (Cs), and strontium (Sr) vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 3, reaching up to 84.8% for the TRISO fuel particles. The release fraction of the other two fission products, Cs and Sr are much smaller and, in most cases, less than 1%. The notable exception is again in Capsule 3, where the release fraction for Cs and Sr reach up to 9.7% and 19.1%, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Manufacture and static firing of X259-E6 rocket motor serial number XJ04/0001

A single motor was cast and static fired to demonstrate the performance of high energy crosslinked double base (XLDB) propellant in standard X259 rocket motor hardware. Prior to motor fabrication, the motor was analyzed to predict the results of static firing the X259 motor loaded with XLDB propellant. As a result of the analyses, a forward dome shrinkage liner was added to the design. With this design change it was determined that adequate margins of safety existed. The motor, designated the X259-E6 model with serial number XJ04/0001, was fabricated using a slurry-casting technique and was assembled with a standard X259-B4 nozzle which had the nozzle throat machined to a smaller inside diameter than the B4 model and the exit cone cut short for Bacchus Works altitude expansion. The motor was static fired on 20 February 1974 with the nozzle failing during motor operation. Nozzle failure was attributed to spalling of the throat material leading to complete nozzle break-up. However, the propellant functioned as predicted in the motor chamber, ignition was normal, and char and erosion of the internal insulator were as expected.

Robertson, D. R.↗

Preliminary results of penetrator field test program, Tonopah, Nevada, 16-28 April 1979

Subscale (0.63 scale) penetrators impacted various sizes of volcanic rocks resting on and within compacted plays sediments. All penetrators were identical in size, shape, weight, and impact velocity. Although minor variations in impact angle were documented, the final orientation of the buried penetrators was primarily a consequence of the size, shape, and depth of the rocks encountered during impact. In situ measurements of impacted penetrators revealed that surface and buried layers of rocks having diameters up to 3 times the penetrator diameter caused only small ( 10 deg) angles of deflection. Only large single rocks greater than 10 times the penetrator diameter caused deflections appreciably greater than 10 deg. The large deflection angles followed by the penetrator were strongly influenced by fracture planes that developed in the rock as it broke apart. No catastrophic failure of the penetrator occurred during these tests. A cross section of the path of each penetrator through the ground is shown together with details on orientation before, during, and after the tests. Comparisons are made with results of previous subscale penetrator tests, and conclusions are drawn with respect to full-scale Mars penetrator performance.

Blanchard, M. B.↗

SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients

Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with a limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.

60 APPLIED LIFE SCIENCES↗

Exact solution of burst pressure for thick-walled pipes using the flow theory of plasticity

This paper develops an exact solution of burst pressure for defect-free, thick-walled pipes using the flow theory of plasticity in terms of the average shear stress yield criterion (or Zhu-Leis yield criterion). The pipe steel is assumed to obey the power-law strain hardening rule, and large plastic deformation is described by the finite strain theory. On this basis, internal pressure is obtained as a power series function of the effective strains on the inside and outside surfaces of the thick-walled pipe with use of the second Bernoulli numbers. At burst failure, the Zhu-Leis flow solution of burst pressure is determined as a power series solution, and the burst effective strains, the burst effective stresses, and the burst pressure are functions of the diameter ratio (D o / D i ), strain hardening exponent (n), and ultimate tensile strength (UTS). Similarly, the Tresca and von Mises flow solutions of burst pressure are also determined as a power series solution in terms of the Tresca and von Mises yield criteria. A general closed-from exact solution of burst pressure is then proposed for the three yield criteria, and the results showed that the proposed exact solution matches well with the power series solution for each yield criterion. Moreover, the von Mises flow solution is an upper bound prediction, the Tresca flow solution is a lower bound prediction, and the Zhu-Leis flow solution is an intermediate prediction that agrees well with the finite element analysis results of burst pressure for thick-walled pipes. Furthermore, two datasets of full-scale burst tests are then utilized to evaluate and validate the proposed flow solutions of burst pressure for both thin and thick-walled pipes.

42 ENGINEERING↗

Damage tolerance research on composite compression panels

The damage tolerance of composites was investigated. Results show that severe degradation in material strength may occur due to impact damage and that reduced strain allowables should be considered to compensate for possible impact damage. The mechanisms of failure involved in impact so that local damage will be reduced and arrest of propagating fracture initiated at impact locations are examined. Compression strength reductions for damage due to impact by a 1.27 cm diameter spherical projectile in thick laminates representative of wing skin panels are presented. Also discussed are the results of concepts recently evaluated to improve damage tolerance. These concepts range from improvements at the materials level to advanced structural configurations designed to arrest or limit the growth of propagating fractures. The results indicate that substantial improvements in the damage tolerance of graphite-epoxy composite structures can be achieved through the proper combination of materials and structural design.

Rhodes, M. D.↗

Effects of load proportioning on the capacity of multiple-hole composite joints

This study addresses the issue of adjusting the proportion of load transmitted by each hole in a multiple-hole joint so that the joint capacity is a maximum. Specifically two-hole-in-series joints are examined. The results indicate that when each hole reacts 50% of the total load, the joint capacity is not a maximum. One hole generally is understressed at joint failure. The algorithm developed to determine the load proportion at each hole which results in maximum capacity is discussed. The algorithm includes two-dimensional finite-element stress analysis and failure criteria. The algorithm is used to study the effects of joint width, hole spacing, and hole to joint-end distance on load proportioning and capacity. To study hole size effects, two hole diameters are considered. Three laminates are considered: a quasi-isotropic laminate; a cross-ply laminate; and a 45 degree angle-ply laminate. By proportioning the load, capacity can be increased generally from 5 to 10%. In some cases a greater increase is possible.

Hyer, M. W.↗

Flooding Experiments and Modeling for Improved Reactor Safety

Countercurrent two-phase flow and “flooding” phenomena in light water reactor systems are being investigated experimentally and analytically to improve reactor safety of current and future reactors. The aspects that will be better clarified are the effects of condensation and tube inclination on flooding in large diameter tubes. The current project aims to improve the level of understanding of flooding mechanisms and to develop an analysis model for more accurate evaluations of flooding in the pressurizer surge line of a Pressurized Water Reactor (PWR). Interest in flooding has recently increased because Countercurrent Flow Limitation (CCFL) in the AP600 pressurizer surge line can affect the vessel refill rate following a small break LOCA and because analysis of hypothetical severe accidents with the current flooding models in reactor safety codes shows that these models represent the largest uncertainty in analysis of steam generator tube creep rupture. During a hypothetical station blackout without auxiliary feedwater recovery, should the hot leg become voided, the pressurizer liquid will drain to the hot leg and flooding may occur in the surge line. The flooding model heavily influences the pressurizer emptying rate and the potential for surge line structural failure due to overheating and creep rupture. The air-water test results in vertical tubes are presented in this paper along with a semi-empirical correlation for the onset of flooding. The unique aspects of the study include careful experimentation on large-diameter tubes and an integrated program in which air-water testing provides benchmark knowledge and visualization data from which to conduct steam-water testing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Long-Term Results of Brachytherapy for Carcinoma of the Penis Confined to the Glans (N- or NX)

Purpose: To analyze the results of exclusive interstitial low-dose-rate brachytherapy (BT) for squamous cell carcinoma (SCC) of the penis, strictly confined to the glans. Methods and Materials: A total of 144 patients with SSC of the glans penis were treated with BT. Inguinal nodal dissection was performed in 19% of patients (all N-). After circumcision, BT was performed using the hypodermic needle technique. Median iridium length per patients was 24 cm (range, 4-108) and median dose was 65 Gy (range, 37-75). Median treated volume was 22 cm{sup 3} (range, 5-110) and median reference isodose rate was 0.4 Gy/h (range, 0.2-1.2). Results: Median follow-up was 5.7 years (range, 0.5-29). The 10-year penile recurrence, inguinal lymph node recurrence, and inguinal nodal metastasis rates were: 20% (CI 95%, 11-29), 11% (CI 95%, 5-17), and 6% (CI 95%, 2-10), respectively. After salvage treatment, 86% patients with local failure were in a complete remission at last follow-up. The 10-year probability of avoiding penile surgery (for complication or local recurrence) was 72% (CI 95%, 62-82). The 10-year cancer-specific survival rate was 92% (CI 95%, 87-97). Diameter of tumor significantly increased the risk of recurrence (p = 0.02). The 10-year painful ulceration and stenosis risk rates were: 26% (CI 95%, 17-35) and 29% (CI 95%, 18-40), respectively. Seven patients required excision for necrosis. Treated volume and reference isodose rate significantly increased the risk of complications. Conclusion: BT is an effective conservative treatment for SCC confined to the glans. Salvage local treatment is effective. Dose rate should be limited to decrease toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Average Burnup in TRISO-Coated Particles from AGR-2 UCO Compacts 2-2-2 and 6-4-2

Burnup analysis was performed on tristructural-isotropic (TRISO)-coated particles deconsolidated from compacts irradiated by the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program in the second irradiation experiment (AGR-2) [Collin 2014]. The AGR-2 irradiation experiment included TRISO fuel particles with kernels containing both uranium oxide and uranium carbide, called UCO, where uranium carbide is included with the commonly-used uranium oxide in the kernel to provide a getter for oxygen liberated during fission and limit CO production. This allows the UCO-TRISO particles to be taken to higher burnup without failure from excessive internal CO pressure or CO-corrosion of the SiC layer. The UCO kernels were fabricated and coated at BWX Technologies Nuclear Operations Group (BWXT-NOG) with a 150-mm-diameter engineering-scale coater. The UCO-TRISO batch used in the AGR-2 irradiation experiment was Batch 93073, which had kernels with an average diameter of 426.7 μm and average coating thicknesses moving out from the kernel of 98.9 μm (buffer), 40.4 μm (IPyC), 35.2 μm (SiC), 43.4 μm (OPyC) [Barnes and Marshall 2009]. The TRISO particle were shipped to ORNL to be formed into compacts for irradiation testing. The compact lot qualified for the AGR-2 irradiation test was lot LEU09-OP2-Z and had an average of 3176 UCO-TRISO particles in each compact [Hunn, Montgomery, and Pappano 2010]. Compilations of the properties data for the particles and compacts are available in a pre-irradiation characterization summary report for the AGR-2 fuel composites [Hunn, Savage, and Silva 2010].

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Propagation or failure of detonation across an air gap in an LX-17 column: continuous time-dependent detonation or shock speed using the Embedded Fiber Optic (EFO) technique

The detailed history of the shock/detonation wave propagation after crossing a room-temperature-room-pressure (RTP) air gap between a 25.4 mm diameter LX-17 donor column and a 25.4 mm diameter by 25.4 mm long LX-17 acceptor pellet is investigated for three different gap widths (3.07, 2.08, and 0.00 mm) using the Embedded Fiber Optic (EFO) technique. The 2.08 mm gap propagated and the 3.07 mm gap failed and this can be seen clearly and unambiguously in the EFO data even though the 25.4 mm-long acceptor pellet would be considered quite short for a determination by more traditional means such as pins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗