At least 253 records · Page 14

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heliostat Observation System Commercialization Qualification HOS-C-Q (Final Technical Report)

Heliostat fields are one of the main components of a concentrated solar thermal plant. As GEN3 technology has been developed at pilot plant level targeting higher temperatures >700C, having a precise Heliostat field control system will enable the success of the GEN3 technology. Heliogen Inc. has developed the next generation of control systems for heliostat fields. Their early development was on single facet heliostats at their R&D facility in Lancaster, California. This new system allows for a closed loop integration to a current open loop setup of a regular Heliostat control system. Sandia National Laboratories and Heliogen Inc. have partnered together to test Heliogen’ s innovative new SOHOT system at the National Solar Thermal Test Facility.

14 SOLAR ENERGY↗

SMART SiC Power ICs: Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (Final Technical Report)

This collaborative project was initiated with the goal of developing Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (SMART SiC Power ICs). In pursuit of this objective, innovative designs and fabrication processes were implemented, enabling the development of large-scale (>1 cm²) SiC Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuits and high-voltage (400–600 V) lateral power MOSFETs (HV-LDMOS) on 150 mm 4H-SiC substrates. The resulting SMART SiC Power ICs are tailored to support a wide range of applications requiring diverse voltage and power levels, including automotive systems, industrial equipment, electronic data processing, energy harvesting, and power conditioning. To achieve the proposed ‘SMART’ technology for SiC ICs, the team focused on 1) the Development of highly scalable CMOS (with high channel mobilities for n-type and p-type MOSFETs), LDMOS (~600V, 10A rated), and IC technologies, 2) Establishment of a manufacturable process baseline in a production-grade-, 150mm, SiC fabrication facility, and 3) Demonstration of SMART SiC ICs. The project initially comprised of fabricating 5 lots. In lot 1 monolithic integration using a single process was achieved. Here, we were able to successfully accomplish Integrated HV NMOSFET with LV CMOS on N-epi/N+ Substrate. The HV NMOS demonstrated a Breakdown Voltage (BV) more than 600V. Circuit demonstration of CMOS was also another achievement from this lot. In lot 2, priority was in place for isolation and integration. Here we addressed the isolation concerns and integrated the HV NMOS and LV CMOS using the N-epi/P-epi/N+ substrate. Similar to the lot 1, we were able to achieve a BV of 600 V for HV NMOS. Optimized gate oxide process with high channel mobilities, better gate oxide reliability, development of SPICE models, successful ohmic process development, novel wafer area saving design layouts, P+ isolation schemes with channeling implantations and high temperature operational circuits demonstrations are some of the key highlights from lot 1 and lot2. In lot 3, discrete device performances of HV NMOS with a BV ~700V and reliable LV CMOS performances were achieved. Also, novel architectural solutions were successfully implemented to suppress the electric field crowding at the gate oxide for reliable operations. In lot 4, half bridge power driver ICs with a conversion efficiency of (target 90% to 95%) in the 1-5MHz switching frequency range for output power between 25 W to 3 kW have been included in. However, due to the unfortunate events of sudden foundry shutdown (SiCamore Semi) the processing of lot 4 wafers came to a complete stop (January 2024). Arrangements have recently been made to shift the fabrication to another foundry, General Electric Aerospace. The fabrication process now on course (as of December 2024). Characterizations are delayed due to this unfortunate circumstance. The proposed trench architectural-based devices and ICs (lot 5) underwent modifications from the original project proposal. This change was necessitated by limitations in the availability of trench-based processes at commercial production-grade fabrication facilities in the US. Apart from above achievements, a Process Development Kit (PDK) was successfully developed for planar type SiC CMOS/LDMOS.

42 ENGINEERING↗

Not Cutting Corners: Bioderived Triggers Driving Oxidative Main Chain Scission of Poly(ethylene terephthalate)

About 20–34 billion poly(ethylene terephthalate) (PET) bottles from the beverage industry leak into aquatic ecosystems annually, necessitating the development of urgent strategies to treat waterborne plastic pollution. Inspired by the scalability of water disinfection infrastructure and protocols, we present a dual depolymerization approach relying on oxidation, followed by hydrolysis. Incorporating bioderived monounsaturated C18 diacid (C18:1-DA) counits at low dosages (2–5%) in the PET backbone overcomes the diffusional limitations of depolymerizing PET in the solid state by suppressing the glass transition temperature of the copolymer by 20 °C. Cryomilled C18:1-PET powder suspended in an oxidant-loaded alkaline slurry underwent bulk depolymerization to oligomers at 80–100 °C via oxidative scissions at the internally located unsaturations. In contrast, conventional PET undergoes only minor end-chain scission under mild alkaline conditions. These oligomers are suitable for low-energy repolymerization or facile solvolysis to monomers. A permanganate-periodate oxidant couple demonstrated successful oxidation through the bulk of the polymer, which subsequently was hydrolyzed to monomers. Furthermore, this model system serves as a proxy for ozonolysis, followed by mild hydrolysis to reduce the energetics of alkaline hydrolysis. This integrated oxidation–hydrolysis strategy paves the way for the industrial adoption of cleaner, advanced oxidation processes, such as ozonolysis for plastic pretreatment, further enabling commercialized chemical recycling of unsaturation-containing polyesters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Succession of Cloud, Precipitation, Aerosol and Air Quality Field Experiments in the Coastal Urban Environment

The interactions and feedbacks among clouds, aerosols, pollutants, and the thermodynamic and kinematic environment remains an area of active research with important implications for our understanding of climate, weather and air quality. These linkages are further complicated in coastal and urban environments where local circulations and anthropogenic influences impact each of these components and their interactions. Within this context, fundamental questions regarding the lifecycle of convective clouds, aerosols and pollutants have brought together a diverse, integrated, and interagency collaboration of scientists to collect and analyze measurements, in the Houston, Texas, area, from the summer of 2021 through the summer of 2022, with subsequent modeling studies to address these important research objectives. Herein, the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Facility and Atmospheric System Research (ASR) Program, the National Science Foundation’s (NSF) Physical and Dynamic Meteorology Program, the National Aeronautic and Space Administration’s (NASA’s) Tropospheric Composition Research and Health and Air Quality Applied Sciences Programs and the Texas Commission on Environmental Quality (TCEQ) are collaborating on a joint set of field campaigns to study the interactions of cloud, aerosol, and pollutants within the coastal, urban environment. In the Houston area, onshore flow from the Gulf of Mexico and the associated sea breeze circulation generates numerous isolated convective cells, particularly in the summer months, that interact with a variety of urban and industrial emissions.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Integrated Urban Services: Program Impact and Business Plan Summary

The Integrated Urban Services (IUS) program, launched in 2021 and funded by the U.S. State Department under the United States-Association of Southeast Asian Nations (US-ASEAN) Smart Cities Partnership, aimed to bolster resilience in ASEAN cities by addressing challenges across food, energy, and water systems. Led by the National Renewable Energy Lab (NREL) with support from Regenerative Impact Ventures, the program focused on demonstrating the socio-economic benefits of integrated urban planning, educating stakeholders on circular economy principles, providing technical assistance to two ASEAN cities, and attracting private sector involvement. The program facilitated peer learning events, engaging public and private sector participants and leveraging knowledge from a group of global experts to inform approaches and best practices. Technical assistance was provided to two pilot cities, Iskandar Malaysia and Cagayan de Oro, Philippines, resulting in the development of market-driven business plans for resilient, circular, and regenerative energy-water-food system projects. The Iskandar Malaysia pilot focused on development of a state-of-the-art AgriTech Innovation Hub and Modern Farming Complex to enhance agricultural productivity and produce enough renewable energy to power the facilities. The Cagayan de Oro project aimed to enhance urban agricultural productivity and waste management through development of an Urban Precision Agricultural Complex featuring aeroponics, hydroponics, aquaponics, agrivoltaics, and a Black Solider Fly Facility for converting municipal solid waste into commodities. The success of the IUS program sets a precedent for replicating integrated urban service models globally, offering valuable insights for cities aiming to enhance their resilience and sustainability.

ASEAN↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synergistic Pathways for Water Security in Emerging Sectors: Data Centers and Modern Nuclear Facilities

Stand-alone data centers, nuclear-powered data centers, and novel nuclear facilities such as fusion plant and small modular reactors (SMRs) are rapidly expanding, water-intensive sectors that present a significant challenge to the water-for-energy nexus. Their large-scale consumption of water for cooling systems not only reduces downstream water quantity but also degrades quality, demanding an integrated approach by stakeholders to understand and address these impacts through infrastructure planning and development.

42 ENGINEERING↗

Design of a SMART Valve Testbed for Nuclear Thermal Dispatch

By the year 2050, the United States aims to achieve net-zero carbon emissions. To achieve this target, the licensing of the Light Water Reactor (LWR) fleet has been extended for 20 more years. To stay economically competitive with other power sources such as renewable and fossil-fuel power plants, the U.S. Department of Energy has introduced a plan to modernize the existing LWR fleet and diversify the revenue stream. One of the plans is to dispatch thermal energy to endothermic industrial processes. SMART valves will play an important role in this initiative by efficiently balancing the load by regulating valves in a coordinated manner while monitoring the thermal-hydraulic systems to enhance safety and maintain the integrity of the power plant. This research aims to develop a facility to test the coordinated control algorithm and produce various test results for training the monitoring system. The constructed facility is capable of simulating various operational and accidental scenarios by coordinating all the valves (positions) and pump (flowrate). The facility is developed with an Internet of Things (IoT)-based custom system and a python-based valve position control and coordination mechanism. It has achieved stable sensor outputs, pump control, and coordinated valve regulation in all three valves with minimum obstruction in the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Analytical Study to Use the Excess Digester Gas of Wastewater Treatment Plants

This study presents an analytical method that can be used to enhance the power production rate and the energy-saving at wastewater treatment plants. The digester used at wastewater treatment plants produces digester gas by anaerobic digestion, with which biofuel production can be achieved. Biofuels can be used to meet some of the energy requirements of the wastewater treatment facility through combined heat and power (CHP) gas engines (cogeneration). Using micro gas turbine (MGT), a CHP technology can be introduced in wastewater treatment plants (WWTPs). The combination of MGTs and absorption chillers is a promising technology as it produces electricity, heating, and cooling simultaneously. The study demonstrated how the waste heat of MGTs could be used to drive absorption chillers. In this analytical study, a detailed technical and economic analysis is provided on the trigeneration system, i.e., the integration of MGTs and absorption chillers driven by waste digester gas of the wastewater treatment plants. It can meet the heating and cooling demands of the plants, which promote the reduction of utility costs. The technology presented is also useful for other thermal energy users.

09 BIOMASS FUELS↗

Integrated Renewable Combined Heat and Power for Ethanol

Conference presentation at 48th International Technical Conference on Clean Energy (Clearwater Clean Energy Conference), Clearwater, Florida, June 16–19, 2024. This project evaluates the technical and economic feasibility of small‑scale combined heat and power (CHP) systems using corn stover to support bioenergy with carbon capture and storage (BECCS) at ethanol facilities. The work includes resource characterization, pilot‑scale gasification and CO 2 capture testing to support techno‑economic analysis, economic evaluation of CHP deployment and potential carbon revenue, and life‑cycle assessment of gasification‑based CHP systems.

09 BIOMASS FUELS↗

Hydropower representation in water and energy system models: a review of divergences and call for reconciliation

Abstract Reservoir-based hydropower systems represent key interactions between water and energy systems and are being transformed under policy initiatives driven by increasing water and energy demand, the desire to reduce environmental impacts, and interacting effects of climate change. Such policies are often guided by complex system models, whereby divergence in system representations can potentially translate to incompatible planning outcomes, thereby undermining any planning that may rely on them. We review different approaches and assumptions in hydropower representation in water and energy systems. While the models and issues are relevant globally, the review focuses on applications in California given its extensive development of energy and water models for policy planning, but discusses the extent to which these observations apply to other regions. Structurally, both water-driven and energy-driven management models are similar. However, in energy models, hydropower is often represented as a single-priority output. Water management models typically allocate water for competing priorities, which are generally uninformed by dynamic electricity load demand, and often result in a lower priority for hydropower. In water models, constraints are increasingly resolved for non-energy components (e.g. inflow hydrology and non-energy water demand); few analogues exist for energy models. These limitations may result in inadequate representations of each respective sector, and vastly different planning outcomes for the same facilities between the two different sectors. These divergent modeling approaches manifest themselves in California where poorly reconciled outcomes may affect decisions in hydropower licensing, electricity grid flexibility and decarbonization, and planning for environmental water. Fully integrated water-energy models are computationally intensive and specific to certain regions, but better representation of each domain in respective efforts would help reconcile divergences in planning and management efforts related to hydropower across energy and water systems.

Rheinheimer, David E. (ORCID:0000000315259069)↗

Hydroelectric Power and Hydrogen Production Integration

Hydropower-based hydrogen production could introduce opportunities for new revenue streams for hydropower plants, including from energy storage and regeneration as well as from sale of the hydrogen product to external markets. Hydrogen-based energy storage and regeneration could also help support Idaho Power’s decarbonization goals by decreasing dependence on fossil-based peaking power plants. Additionally, integration of hydrogen production with hydropower generation could help address the issue of low dissolved oxygen river water conditions that commonly accompany hydropower plant operations by utilizing the oxygen byproduct from an electrolytic hydrogen production process as a resource for mitigation of low dissolved oxygen water conditions. Comprehensive techno-economic analysis of the hybrid hydroelectric and hydrogen energy storage system has revealed critical insights into the pathways and considerations for optimizing the economic value and environmental benefits of such systems. Among the three identified pathways of natural gas blending, regeneration, and direct sale of hydrogen, the direct sale of hydrogen emerges as the most profitable, particularly given the current pricing dynamics of hydrogen and electricity. However, as we anticipate a future grid characterized by higher renewable energy penetration, the landscape may evolve, featuring lower average electricity prices, heightened fluctuations, and more significant seasonal variations. Consequently, the attractiveness of electricity regeneration through hydrogen and the benefits of long-duration hydrogen storage are expected to increase substantially in such a dynamic energy scenario. The careful selection of component sizes within the hybrid system proves to be paramount for ensuring cost-effectiveness. Notably, the size of the hydrogen market has emerged as a critical determinant for the optimal size of the electrolyzer. Hydrogen storage should be sized to meet energy shifting requirements. The appropriate size of the fuel cell/microturbine generator hinges on the shape of electricity prices and the available revenue streams derived from participating in grid services. Striking the right balance among these components is essential for maximizing the overall efficiency and profitability of the hydrogen facility. Furthermore, the by-product of electrolysis, namely oxygen, introduces an additional dimension to the system's functionality. The oxygen generated can be effectively utilized for dissolved oxygen (DO) mitigation, particularly with larger electrolyzer sizes capable of satisfying the complete oxygen demand for this purpose. While the economic benefits derived from saved oxygen purchase costs may be relatively modest compared to other revenue streams, the environmental advantages of repurposing oxygen for DO mitigation could help Idaho Power meet their environmental obligations. In addition to the identified factors shaping the viability of hybrid hydrogen production and hydroelectric generation, it is noteworthy that the integration of hydrogen energy storage offers a unique advantage during unusually wet years. In such periods of increased water inflow, the hydrogen storage capacity serves as a valuable supplement to the reservoir. By utilizing hydrogen energy storage as a complementary reservoir, the system gains flexibility in reservoir management when dealing with fluctuations in water availability.

08 HYDROGEN↗

NEAMS Workbench Status and Capabilities

The mission of the US Department of Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program is to develop, apply, deploy, and support state-of-the-art predictive modeling and simulation tools for the design and analysis of current and future nuclear energy systems. This is accomplished by using computing architectures that range from laptops to leadership-class facilities. The NEAMS Workbench is a new initiative that will facilitate the transition from conventional tools to highfidelity tools by providing a common user interface for model creation, review, execution, output review, and visualization for integrated codes. The Workbench can use common user input, including engineering-scale specifications that are expanded into application-specific input requirements through the use of customizable templates. The templating process can enable multifidelity analysis of a system from a common set of input data. Additionally, the common user input processor can provide an enhanced alternative application input that provides additional conveniences compared with native input, especially for legacy codes. Expansion of the integrated codes and application templates available in the Workbench will broaden the NEAMS user community and will facilitate system analysis and design. Current and planned capabilities of the NEAMS Workbench are detailed herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAIL Aerosol Vertical Profiles (SAIL-AVP) Field Campaign Report

Aerosols are central to understanding the water cycle within mountainous regions, but a complete understanding of this role cannot be provided without vertically resolved observations, particularly for aerosol-cloud interactions, since we simultaneously need to know aerosol information and meteorology near cloud bases. The goal of SAIL Aerosol Vertical Profiles (SAIL-AVP) was to perform tethered balloon system (TBS) measurements during different seasons to elucidate process-level understanding of the aerosols and associated meteorological conditions within complex mountainous terrain. Measurements were conducted during the deployment of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s second Mobile Facility (AMF2) as part of the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign in the East River Watershed of the Upper Colorado River Basin (UCRB) in southwestern Colorado. In mid-latitude continental interior mountain ranges, and especially at SAIL, aerosol vertical profiles and their relationships with meteorology are, almost without exception, inferred from a combination of ground-based and remote-sensing data. These flights provided many more dimensions to aerosol-cloud interactions that are unavailable to those inferential approaches: the TBS collected in situ information in the vertical, optical, chemical, and biological dimensions for aerosol-cloud interactions. Furthermore, the collocation of these flights with longstanding collaborative resources in the region, including the ongoing surface and subsurface hydrologic observations from the DOE’s Watershed Function Science Focus Area (SFA), produced a unique set of atmospheric observations that are complemented by existing land-surface and subsurface (e.g., groundwater) observations.

54 ENVIRONMENTAL SCIENCES↗

Electric Vehicles at Scale (EVs@Scale) Laboratory Consortium Deep-Dive Technical Meetings: High Power Charging (HPC) Summary Report

Electric vehicle (EV) adoption will change the composition of EV charging load to higher-power charging as more medium- (MD) and heavy-duty (HD) applications are electrified, and as all vocations, including light-duty (LD) vehicles, are capable of faster charging. These shifts provide the opportunity for high-power charging (HPC) and facility equipment to evolve and improve efficiency, cost, and space. High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project designs and develops a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration approaches and technology solutions. The project addresses (1) interconnection and management of a grid-tied inverter; (2) development of a DC distribution system that is responsible for system energy management, interoperability, and DC protection; (3) modular DC/DC conversion for vehicle charging; (4) EV charging interface and DC/DC integration; and (5) smart charge control and vehicle-to-edge (vehicle-to-building [V2B], vehicle-to-everything [V2X]) capability. This summary presentation is the first technical progress output of the project. It provides insight for the first deep-dive technical meeting outputs in terms of research presentations and also includes summary of the discussions occurred in the follow-up breakout sessions. The summary presentation covers three technical areas: (1) HPC: State of the art power architectures and the design of the power electronics, (2) Modeling, energy management, and power control in the HPC station, and (3) Codes and standards work that are in line with the previous two topic areas.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Gen 3 Particle Pilot Plant (G3P3) -- High-Temperature Particle System for Concentrating Solar Power (Phases 1 and 2)

The U.S. Department of Energy Solar Energy Technologies Office initiated the Generation 3 Concentrating Solar Power (CSP) program to achieve higher operating temperatures (>700 °C) to enable next-generation CSP high-temperature power cycles such as the supercritical CO 2 (sCO2) Brayton Cycle. Three teams were selected to pursue high-temperature gas, liquid, and solid pathways for the heat-transfer media. Phases 1 and 2, which lasted from 2018 – 2020, consisted of design, modeling, and testing activities to further de-risk each of the technologies and develop a design for construction, commissioning, and operation of a pilot-scale facility in Phase 3 (2021 – 2024). This report summarizes the activities in Phases 1 and 2 for the solid-particle pathway led by Sandia National Laboratories. In Phases 1 and 2, Sandia successfully de-risked key elements of the proposed Gen 3 Particle Pilot Plant (G3P3) by improving the design, operation, and performance of key particle component technologies including the receiver, storage bins, particle-to-sCO2 heat exchanger, particle lift, and data acquisition and controls. Modeling and testing of critical components have led to optimized designs that meet desired performance metrics. Detailed drawings, piping and instrumentation diagrams, and process flow diagrams were generated for the integrated system, and structural analyses of the assembled tower structure were performed to demonstrate compliance with relevant codes and standards. Instrumentation and control systems of key subsystems were also demonstrated. Together with Bridgers & Paxton, Bohannan Huston, and Sandia Facilities, we have completed a 100% G3P3 tower design package with stamped engineering drawings suitable for construction bid in Phase 3.

14 SOLAR ENERGY↗