Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronic Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Increasing the Luminescence Yield of Zirconia

The effect of high-temperature treatment in vacuum in the presence of carbon as a reducing agent on the luminescent properties of zirconia is studied. It is shown that an increase in the intensity of pulsed cathodoluminescence at 480 nm and thermoluminescence in the dominant peak at 500 K is due to the thermochemical coloration of the initial samples with the formation of oxygen vacancies detected by electron paramagnetic resonance. The described procedure for increasing the luminescence yield of ZrO{sub 2} can be applied when it is used in optoelectronics, photonics, and radiation dosimetry.

36 MATERIALS SCIENCE↗

In Situ Transmission Electron Microscopy of High-Temperature Inconel-625 Corrosion by Molten Chloride Salts

This paper describes an approach to monitor high temperature molten chloride (MgCl 2 -NaCl-KCl) salt corrosion of Inconel-625 alloy in real time at high spatial resolution. The approach is based on a micro-environmental-cell assembly integrated into a transmission-electron-microscope goniometer to examine in situ the salt-alloy interface during corrosion, employing real time electron diffraction and imaging. It establishes procedures to minimize incorporation of H 2 O or O 2 from atmosphere in the chloride salts during sample fabrication and corrosion, which is critical to understanding the fundamental corrosion mechanisms. A clustering algorithm and a 2D Gaussian fit function are used to determine diffraction spot intensities in in situ diffraction patterns, to quantify alloy corrosion. This facilitates quantitative observation of the evolution of individual grains, in contrast to conventional macroscopic corrosion rate quantification. The isothermal corrosion rate of Inconel-625 in an anhydrous, unoxidized salt-stack is 220 ± 30 μm year -1 at 700 °C and 350 ± 20 μm year -1 at 800 °C. However, the corrosion rate at 700 °C increases five-fold to 1000 ± 170 μm year -1 when the salt stack is air-exposed, indicating the dominant effects of hydrated or oxidized impurities on corrosion acceleration. Furthermore, real time imaging of the microstructure evolution suggests that corrosion is initiated at grain boundaries.

14 SOLAR ENERGY↗

HB-Line Plutonium Oxide Data Collection Strategy

HB-Line and H-Canyon will handle and process plutonium material to produce plutonium oxide for feed to the Mixed Oxide Fuel Fabrication Facility (MFFF). However, the plutonium oxide product will not be transferred to the MFFF directly from HB-Line until it is packaged into a qualified DOE-STD-3013-2012 container. In the interim, HB-Line will load plutonium oxide into an inner, filtered can. The inner can will be placed in a filtered bag, which will be loaded into a filtered outer can. The outer can will be loaded into a certified 9975 with getter assembly in compliance with onsite transportation requirement, for subsequent storage and transfer to the K-Area Complex (KAC). After DOE-STD-3013-2012 container packaging capabilities are established, the product will be returned to HB-Line to be packaged into a qualified DOE-STD-3013-2012 container. To support the transfer of plutonium oxide to KAC and then eventually to MFFF, various material and packaging data will have to be collected and retained. In addition, data from initial HB-Line processing operations will be needed to support future DOE-STD-3013-2012 qualification as amended by the HB-Line DOE Standard equivalency. As production increases, the volume of data to collect will increase. The HB-Line data collected will be in the form of paper copies and electronic media. Paper copy data will, at a minimum, consist of facility procedures, nonconformance reports (NCRs), and DCS print outs. Electronic data will be in the form of Adobe portable document formats (PDFs). Collecting all the required data for each plutonium oxide can will be no small effort for HB-Line, and will become more challenging once the maximum annual oxide production throughput is achieved due to the sheer volume of data to be collected. The majority of the data collected will be in the form of facility procedures, DCS print outs, and laboratory results. To facilitate complete collection of this data, a traveler form will be developed which identifies the required facility procedures, DCS print outs, and laboratory results needed to assemble a final data package for each HB-Line plutonium oxide interim oxide can. The data traveler may identify the specific values (data) required to be extracted from the collected facility procedures and DCS print outs. The data traveler may also identify associated criteria to be checked. Inevitably there will be procedure anomalies during the course of the HB-Line plutonium oxide campaign that will have to be addressed in a timely manner.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molecular-Frame Angular Distributions of Resonant CO:C(1s) Auger Electrons

The molecular-frame angular distributions of resonantly excited CO:C(1s){yields}{pi}* Auger electrons were determined using angle-resolved electron-ion coincidence spectroscopy in combination with a novel transformation procedure. Our new methodology yields full three-dimensional electron angular distributions with high energy resolution from the measurement of electrons at only two angles. The experimentally determined distributions are well reproduced by calculations performed in a simple one-center approximation, allowing an unambiguous identification of several overlapping Auger lines.

74 ATOMIC AND MOLECULAR PHYSICS↗

Materials and techniques for spacecraft static charge control

An overview of the design, development, fabrication, and testing of transparent conductive coatings and conductive lattices deposited or formed on high resistivity spacecraft dielectric materials to obtain control static charge buildup on spacecraft external surfaces is presented. Fabrication techniques for the deposition of indium/tin oxide coatings and copper grid networks on Kapton and FEP Teflon films and special frit coatings for OSR and solar cell cover glasses are discussed. The techniques include sputtering, photoetching, silkscreening, and mechanical processes. A facility designed and built to simulate the electron plasma at geosynchronous altitudes is described along with test procedures. The results of material characterizations as well as electron irradiation aging effects in this facility for spacecraft polymers treated to control static charge are presented. The data presents results for electron beam energies up to 30 kV and electron current densities of 30 nA/cm squared. Parameters measured include secondary emission, surface leakage, and through the sample currents as a function of primary beam energy and voltage.

Amore, L. J.↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graphene as a transparent conductive support for studying biological molecules by transmission electron microscopy

We demonstrate the application of graphene as a support for imaging individual biological molecules in transmission electron microscope (TEM). A simple procedure to produce free-standing graphene membranes has been designed. Such membranes are extremely robust and can support practically any submicrometer object. Tobacco mosaic virus has been deposited on graphene samples and observed in a TEM. High contrast has been achieved even though no staining has been applied.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Possible Way To Describe Breit's Interaction in Solids Composed From Heavy Elements

The report describes a theoretical procedure which could help evaluate the effect of quantum electrodynamic corrections on the electronic structure of crystals consisting of heavy elements. The procedure uses the effective Breit interaction as correction to traditional Coulomb interaction between electrons in non-relativistic theory. A number of other simplifying assumptions were made since even such a simplified consideration of quantum electrodynamic effects in crystals is a great challenge. These are as follows: (1) Exchange and correlation effects from the nonrelativistic interaction (the Coulomb term) between electrons are described within Density Functional Theory (DFT). (2) The Breit correction is on at the phase which involves the calculation of matrix elements between basis functions which define the single-electron spectrum of a crystal. In order to calculate the contribution from the Breit correction, the total wave function of electrons in the crystal is approximated by one Slater determinant consisting of the single-electron DFT-orbitals. (3) Only local matrix elements (i.e., the part of the two-electron integral for which both coordinate arguments belong to one and the same muffin-tin sphere) are considered.

36 MATERIALS SCIENCE↗

Photoconductivities from band states and a dissipative electron dynamics: Si(111) without and with adsorbed Ag clusters

A new general computational procedure is presented to obtain photoconductivities starting from atomic structures, combining ab initio electronic energy band states with populations from density matrix theory, and implemented for a specific set of materials based on Si crystalline slabs and their nanostructured surfaces without and with adsorbed Ag clusters. The procedure accounts for charge mobility in semiconductors in photoexcited states, and specifically electron and hole photomobilities at Si(111) surfaces with and without adsorbed Ag clusters using ab initio energy bands and orbitals generated from a generalized gradient functional, however with excited energy levels modified to provide correct bandgaps. Photoexcited state populations for each band and carrier type were generated using steady state solution of a reduced density matrix which includes dissipative medium effects. The present calculations provide photoexcited electronic populations and photoinduced mobilities resulting from applied electric fields and obtained from the change of driven electron energies with their electronic momentum. Extensive results for Si slabs with 8 layers, without and with adsorbed Ag clusters, show that the metal adsorbates lead to substantial increases in the photomobility and photoconductivity of electrons and holes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Audit Report on "Protection of the Department of Energy's Unclassified Sensitive Electronic Information"

The Department of Energy and its contractors store and process massive quantities of sensitive information to accomplish national security, energy, science, and environmental missions. Sensitive unclassified data, such as personally identifiable information (PII), official use only, and unclassified controlled nuclear information require special handling and protection to prevent misuse of the information for inappropriate purposes. Industry experts have reported that more than 203 million personal privacy records have been lost or stolen over the past three years, including information maintained by corporations, educational institutions, and Federal agencies. The loss of personal and other sensitive information can result in substantial financial harm, embarrassment, and inconvenience to individuals and organizations. Therefore, strong protective measures, including data encryption, help protect against the unauthorized disclosure of sensitive information. Prior reports involving the loss of sensitive information have highlighted weaknesses in the Department's ability to protect sensitive data. Our report on Security Over Personally Identifiable Information (DOE/IG-0771, July 2007) disclosed that the Department had not fully implemented all measures recommended by the Office of Management and Budget (OMB) and required by the National Institute of Standards and Technology (NIST) to protect PII, including failures to identify and encrypt PII maintained on information systems. Similarly, the Government Accountability Office recently reported that the Department had not yet installed encryption technology to protect sensitive data on the vast majority of laptop computers and handheld devices. Because of the potential for harm, we initiated this audit to determine whether the Department and its contractors adequately safeguarded sensitive electronic information. The Department had taken a number of steps to improve protection of PII. Our review, however, identified opportunities to strengthen the protection of all types of sensitive unclassified electronic information and reduce the risk that such data could fall into the hands of individuals with malicious intent. In particular, for the seven sites we reviewed: (1) Four sites had either not ensured that sensitive information maintained on mobile devices was encrypted. Or, they had improperly permitted sensitive unclassified information to be transmitted unencrypted through email or to offsite backup storage facilities; (2) One site had not ensured that laptops taken on foreign travel, including travel to sensitive countries, were protected against security threats; and, (3) Although required by the OMB since 2003, we learned that programs and sites were still working to complete Privacy Impact Assessments - analyses designed to examine the risks and ramifications of using information systems to collect, maintain, and disseminate personal information. Our testing revealed that the weaknesses identified were attributable, at least in part, to Headquarters programs and field sites that had not implemented existing policies and procedures requiring protection of sensitive electronic information. In addition, a lack of performance monitoring contributed to the inability of the Department and the National Nuclear Security Administration (NNSA) to ensure that measures were in place to fully protect sensitive information. As demonstrated by previous computer intrusion-related data losses throughout the Department, without improvements, the risk or vulnerability for future losses remains unacceptably high. In conducting this audit, we recognized that data encryption and related techniques do not provide absolute assurance that sensitive data is fully protected. For example, encryption will not necessarily protect data in circumstances where organizational access controls are weak or are circumvented through phishing or other malicious techniques. However, as noted by NIST, when used appropriately, encryption is an effective tool that can, as part of an overall risk-management strategy, enhance security over critical personal and other sensitive information. The audit disclosed that Sandia National Laboratories had instituted a comprehensive program to protect laptops taken on foreign travel. In addition, the Department issued policy after our field work was completed that should standardize the Privacy Impact Assessment process, and, in so doing, provide increased accountability. While these actions are positive steps, additional effort is needed to help ensure that the privacy of individuals is adequately protected and that sensitive operational data is not compromised. To that end, our report contains several recommendations to implement a risk-based protection scheme for the protection of sensitive electronic information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Improved Results on Extraction of {sup 11}B(p, {alpha}{sub 0}){sup 8}Be and {sup 10}B(p, {alpha}){sup 7}Be S(E)-Factor Through the Trojan Horse Method

In this work the analysis of the {sup 10}B(23p, {alpha}){sup 7}Be and {sup 11}B(p, {alpha}){sup 8}Be reactions, studied via the indirect Trojan Horse Method (THM), is discussed. In the astrophysical context of light nuclei LiBeB depletion, the above mentioned reactions are the main responsible for the destruction of boron in the stellar interior. The THM application allows their investigation in the astrophysically relevant energy region, around the Gamow Peak ({approx_equal}10 keV), overcoming the problems due to the presence of the Coulomb barrier and electron screening effect. The experimental procedure and the preliminary results are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electronic structure and optical properties of quantum crystals from first principles calculations in the Born–Oppenheimer approximation

In this work, we develop a formalism to accurately account for the renormalization of the electronic structure due to quantum and thermal nuclear motions within the Born–Oppenheimer approximation. We focus on the fundamental energy gap obtained from electronic addition and removal energies from quantum Monte Carlo calculations in either the canonical or grand-canonical ensembles. The formalism applies as well to effective single electron theories such as those based on density functional theory. We show that the electronic (Bloch) crystal momentum can be restored by marginalizing the total electron–ion wave function with respect to the nuclear equilibrium distribution, and we describe an explicit procedure to establish the band structure of electronic excitations for quantum crystals within the Born–Oppenheimer approximation. Based on the Kubo–Greenwood equation, we discuss the effects of nuclear motion on optical conductivity. Our methodology applies to the low temperature regime where nuclear motion is quantized and, in general, differs from the semi-classical approximation. We apply our method to study the electronic structure of C2/c-24 crystalline hydrogen at 200 K and 250 GPa and discuss the optical absorption profile of hydrogen crystals at 200 K and carbon diamond at 297 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of nonisothermal electrons on dressed soliton in ion beam plasma system

Using the reductive perturbation method (RPM) evolution equations, governing the first and second order potentials for ion acoustic wave in an ion beam plasma system with nonisothermal electrons, are derived. Adopting renormalization procedure of Kodama and Taniuti [J. Phys. Soc. Jpn. 45, 298 (1978)] nonsecular dressed soliton solution of these coupled equations is determined. An alternative approach is also used to obtain large amplitude soliton solution, retaining higher order nonlinearities in the expansion of the Sagdeev potential and integrating the resulting energy equation for the system. For small amplitude approximation, this solution reduces to dressed soliton solution obtained for the system using the renormalization in the RPM. Variation of the amplitude (A), velocity ({lambda}), width (W), and the product amplitudexwidth{sup 4} (AW{sup 4}) are numerically studied for the Korteweg-de Vries, dressed and large amplitude soliton for different values of parameters of the beam-plasma system, and results are summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory electron screening in nuclear resonance reactions

Both nonresonant and resonance reaction data are subject to laboratory electron screening effects. For non resonant reactions, such effects are well documented and the measured cross sections can be corrected to find the unscreened ones. Frequently, the procedure and expression to calculate laboratory electron screening factors for nonresonant reactions are also applied to isolated narrow resonances, without much theoretical support or experimental evidence. Here, a simple model is applied to estimate electron screening factors, lengths, and potentials for narrow resonances. The corrections to the measured data result in an enhancement of the unscreened resonance strengths by less than 0.2%, contrary to published narrow-resonance screening correction factors, which predict a reduction of the unscreened strengths by up to 25%. Unless it can be proven otherwise, it is recommended that measured strengths of isolated narrow resonances not be corrected for laboratory electron screening. The prospects of investigating laboratory electron screening effects by measuring almost negligible differences in resonance strengths are not promising. Instead, the difference of the resonance energy for the unscreened and screened situation may be measurable. As an example, the case of the E r = 956-keV resonance in the 27 Al(p,γ) 28 Si reaction is discussed. It is also demonstrated that the claim of a previously reported detection of a resonance near 800 keV in the 176 Lu(p,n) 176 Hf reaction is incorrect.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Retrospective IMRT Dose Reconstruction Based on Cone-Beam CT and MLC Log-File

Purpose: Head-and-neck (HN) cone-beam computed tomography (CBCT) can be exploited to probe the IMRT dose delivered to a patient taking into account the interfraction anatomic variation and any potential inaccuracy in the IMRT delivery. The aim of this work is to reconstruct the intensity-modulated radiation therapy dose delivered to an HN patient using the CBCT and multileaf collimator (MLC) log-files. Methods and Materials: A cylindrical CT phantom was used for calibrating the electron density and validating the procedures of the dose reconstruction. Five HN patients were chosen, and for each patient, CBCTs were performed on three separate fractions spaced every 2 weeks starting from the first fraction. The respective MLC log-files were retrieved and converted into fluence maps. The dose was then reconstructed on the corresponding CBCT with the regenerated fluence maps. The reconstructed dose distribution, dosimetric endpoints, and DVHs were compared with that of the treatment plan. Results: Phantom study showed that HN CBCT can be directly used for dose reconstruction. For most treatment sessions, the CBCT-based dose reconstructions yielded DVHs of the targets close (within 3%) to that of the original treatment plans. However, dosimetric changes (within 10%) due to anatomic variations caused by setup inaccuracy, organ deformation, tumour shrinkage, or weight loss (or a combination of these) were observed for the critical organs. Conclusions: The methodology we established affords an objective dosimetric basis for the clinical decision on whether a replanning is necessary during the course of treatment and provides a valuable platform for adaptive therapy in future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a drift-correction procedure for a direct-reading spectrometer

A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

Chapman, G. B., II↗

Corrections of satellite positions in near-real time.

The influence of sudden increases of electron content on the accurate determination of the position of a satellite is investigated based on a spherically stratified ionospheric model. Using the total electron content information from Faraday rotation measurements, a procedure is presented whereby the corrections of satellite position due to the unpredicted electron increase can be accounted for without the need to know the spatial distribution of the additional electrons.

Poularikas, A. D.↗

Nanostructured materials for selective collection of trace-level metals from aqueous systems.

Nanostructured materials for selective collection of trace-level metals from aqueous systems A critical ability for responding to situations involving environmental contaminants is the ability to quickly identify the contaminant(s) involved and the scope of the contamination. Simple field-screening methods are needed to enable on-site, information allocation and decision making. Currently, analytical technology does not exist to allow quick, accurate, and efficient analysis. Existing field-screening methods lack the selectivity and sensitivity needed to provide key information. A large leap in performance is needed and is very unlikely to be achieved with incremental improvements in procedure, instrument design, or improved electronics. A new analytical approach is required. Deficiencies in selectivity and sensitivity can be addressed with high-performance sorbent materials capable of selectively concentrating the target analytes and removing them from the sample matrix. By concentrating and removing the target analyte, these sorbent materials provide a well-defined matrix for analysis. This chapter examines the use of nanostructured materials for the selective collection of trace-level metals from aqueous systems. The focus lies on thiol-functionalized materials. Focusing on thiol surface chemistry allows comparison of mesoporous silica, activated carbon, and superparamagnetic nanoparticles. The chapter also discusses zeolites, imprinted polymer materials, and activated carbon in general. The materials reviewed here are evaluated based on capacity, selectivity, and affinity for target analytes. Research presented here shows that correctly constructed nanostructured materials are superior to conventional sorbents.

nanomaterials, nanostructures, SAMMS, trace level ↗