Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Induced Radioactivity Analysis for the NSRL Linac in China Using Monte Carlo Simulations and Gamma Spectroscopy - Paper 141

The Synchrotron Radiation Facility of the National Synchrotron Radiation Laboratory (NSRL) located in Hefei, China consists of a 200-MeV electron linear accelerator and an 800-MeV electronic storage ring. Constructed in 1989, the 200-MeV Electron linac is one of the earliest high-energy electron linear accelerators in China. The NSRL is a large-scale experiment device, having been operated more than twenty years, so it is hard to give a historical recount about the injection of NSRL Linac. Lower-energy electrons emitted from the accelerator electron gun are progressively accelerated to about 200 MeV in five acceleration tubes, and then are injected into the electron storage ring, reaching the final energy of 800 MeV. The linear accelerator is a traveling wave linear accelerator, consisting of pre-injection, four 6-m acceleration segment, some beam sensing elements, and focusing inserts. The electrons are accelerated in the acceleration tubes to 32 MeV, 74 MeV, 116 MeV, 158 MeV, respectively, and the electronic energy reaches 200 MeV at the end of the acceleration trip. A scraper is used for beam collimation and is located at the end of each acceleration tube, with a length that increases with the energy to provide sufficient collimation. The NSRL Linac was retired in 2012 due to a plan to upgrade the facility. The decommissioning produced many real challenges related to the methods to handle the large size of the device and the time required to store structural materials until the radioactivity is reduced in the waste repository. These problems should be solved as soon as possible in order for the upgrade to proceed smoothly. At present, no prior decommissioning experience existed in China on such a high-energy electron linear accelerator. Therefore, the decommission project provided an opportunity to study and evaluate the challenges, in particular, involving the induced radioactivity for the purposes of radiation protection. For a well-shielded accelerator facility, the induced radioactivity is an important source of radiation for people who perform the decommissioning. In addition, information on the level of induced radioactivity is needed for disposing of the retired accelerator materials. Therefore it is significant to predict such radioactivity level accurately. However, the induced radioactivity study for such type high-energy electron linear accelerator is very seldom. Particle accelerators that operate at energy greater than 10 MeV will produce induced radioactivity due to well-known photonuclear interactions. However, the assessment of such as induced radioactivity of large-scale installations is a time-consuming process. Experimental methods are time-consuming and require special radiation safety measures to protection the investigators. On the other hand, empirical formula cannot yield sufficiently accurate results. Therefore, Monte Carlo simulation method is the primary means to study such problems. In the decommissioning process of the NSRL Linac, the induced radioactivity assessment will be based on Monte Carlo simulation method as the main auxiliary means to expand a series of studies. (authors)

43 PARTICLE ACCELERATORS↗

MO-H-19A-02: Investigation of Modulated Electron Arc (MeArc) Therapy for the Treatment of Scalp Tumors

Purpose: Electron arc therapy has long been proposed as the most suitable technique for the treatment of superficial tumors that follow circularly curved surfaces. However it was challenged by unsuitability of the conventional applicators and the lack of adequate 3-D dose calculation tools for arc electron beams in the treatment planning systems (TPS). Now with the availability of an electron specific multi-leaf collimator (eMLC) and an in-house Monte Carlo (MC) based TPS, we were motivated to investigate more advanced modulated electron arc (MeARC) therapy and its beneficial outcome. Methods: We initiated the study by a film measurement conducted in a head and neck phantom, where we delivered electron arcs in a step and shoot manner using the light field as a guide to avoid fields abutments. This step was done to insure enough clearance for the arcs with eMLC. MCBEAM and MCPLAN MC codes were used for the treatment head simulation and phantom dose calculation, respectively. Treatment plans were generated for targets drawn in real patient CTs and head and neck phantom. We utilized beams eye view available from a commercial planning system to create beamlets having same isocenter and adjoined at the scalp surface. Then dose-deposition coefficients from those beamlets were calculated for all electron energies using MCPLAN. An in-house optimization code was then used to find the optimum weights needed from individual beamlets. Results: MeARC showed a nicely tailored dose distribution around the circular curved target on the scalp. Some hot spots were noticed and could be attributed to fields abutment problem owing to the bulging nature of electron profiles. Brain dose was shown to be at lower levels compared to photon treatment. Conclusion: MeARC was shown to be a promising modality for treating scalp cases and could be beneficial to all superficial tumors with a circular curvature.

60 APPLIED LIFE SCIENCES↗

Selection Tests of MnZn and NiZn Ferrites for Mu2e 300 kHz and 5.1 MHz AC Dipoles

Mu2e, a charged lepton flavor violation (CLFV) experiment is planned to start at Fermilab late in this decade. The proposed experiment will search for neutrinoless muon to electron conversions with unprecedented sensitivity, better than 6 x 10{sup -17 }at 90% CL. To achieve this sensitivity the incoming proton beam must be highly suppressed during the window for detecting the muon decays. The current proposal for beam extinction is based on a collimator design with two dipoles running at {approx}300 kHz and 5.1 MHz and synchronized to the proton bunch spacing. The appropriate choice of ferrite material for the magnet yoke is a critical step in the overall design of the dipoles and their reliable operation at such high frequencies over the life of the experiment. This choice, based on a series of the thermal and magnetic measurements of the ferrite samples, is discussed in the paper. Additionally, the first results from the testing at 300 kHz of a prototype AC dipole are presented.

43 PARTICLE ACCELERATORS↗

Radiation collimator and systems incorporating same

A collimator including a housing having disposed therein a shield element surrounding a converter core in which a photon beam is generated from electrons emanating from a linear accelerator. A beam channeler longitudinally adjacent the shield element has a beam aperture therethrough coaxially aligned with, and of the same diameter as, an exit bore of the converter core. A larger entry bore in the converter core is coaxial with, and longitudinally separated from, the exit bore thereof. Systems incorporating the collimator are also disclosed.

47 OTHER INSTRUMENTATION↗

Commissioning of the Varian TrueBeam linear accelerator: A multi-institutional study

Purpose: Latest generation linear accelerators (linacs), i.e., TrueBeam (Varian Medical Systems, Palo Alto, CA) and its stereotactic counterpart, TrueBeam STx, have several unique features, including high-dose-rate flattening-filter-free (FFF) photon modes, reengineered electron modes with new scattering foil geometries, updated imaging hardware/software, and a novel control system. An evaluation of five TrueBeam linacs at three different institutions has been performed and this work reports on the commissioning experience. Methods: Acceptance and commissioning data were analyzed for five TrueBeam linacs equipped with 120 leaf (5 mm width) MLCs at three different institutions. Dosimetric data and mechanical parameters were compared. These included measurements of photon beam profiles (6X, 6XFFF, 10X, 10XFFF, 15X), photon and electron percent depth dose (PDD) curves (6, 9, 12 MeV), relative photon output factors (Scp), electron cone factors, mechanical isocenter accuracy, MLC transmission, and dosimetric leaf gap (DLG). End-to-end testing and IMRT commissioning were also conducted. Results: Gantry/collimator isocentricity measurements were similar (0.27-0.28 mm), with overall couch/gantry/collimator values of 0.46-0.68 mm across the three institutions. Dosimetric data showed good agreement between machines. The average MLC DLGs for 6, 10, and 15 MV photons were 1.33 {+-} 0.23, 1.57 {+-} 0.24, and 1.61 {+-} 0.26 mm, respectively. 6XFFF and 10XFFF modes had average DLGs of 1.16 {+-} 0.22 and 1.44 {+-} 0.30 mm, respectively. MLC transmission showed minimal variation across the three institutions, with the standard deviation <0.2% for all linacs. Photon and electron PDDs were comparable for all energies. 6, 10, and 15 MV photon beam quality, %dd(10){sub x} varied less than 0.3% for all linacs. Output factors (Scp) and electron cone factors agreed within 0.27%, on average; largest variations were observed for small field sizes (1.2% coefficient of variation, 10 MV, 2 Multiplication-Sign 2 cm{sup 2}) and small cone sizes (<1% coefficient of variation, 6 Multiplication-Sign 6 cm{sup 2} cone), respectively. Conclusions: Overall, excellent agreement was observed in TrueBeam commissioning data. This set of multi-institutional data can provide comparison data to others embarking on TrueBeam commissioning, ultimately improving the safety and quality of beam commissioning.

43 PARTICLE ACCELERATORS↗

Multipeak emission of the fast electron beams along the target surface in ultrashort laser interaction with solid targets

The spatial and energy distributions of fast electrons emitted from foil targets irradiated by ultrashort intense laser pulses are measured. Four groups of collimated emissions of fast electrons along the front and rear target surfaces are observed for an incidence angle of <60 deg. This multipeak characterization is found to be independent of laser polarization states. Numerical simulations reveal that the electron beams are formed due to the deformation of the target surface and then guided by the induced quasistatic electromagnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An EPID response calculation algorithm using spatial beam characteristics of primary, head scattered and MLC transmitted radiation

We have developed an independent algorithm for the prediction of electronic portal imaging device (EPID) response. The algorithm uses a set of images [open beam, closed multileaf collimator (MLC), various fence and modified sweeping gap patterns] to separately characterize the primary and head-scatter contributions to EPID response. It also characterizes the relevant dosimetric properties of the MLC: Transmission, dosimetric gap, MLC scatter [P. Zygmansky et al., J. Appl. Clin. Med. Phys. 8(4) (2007)], inter-leaf leakage, and tongue and groove [F. Lorenz et al., Phys. Med. Biol. 52, 5985-5999 (2007)]. The primary radiation is modeled with a single Gaussian distribution defined at the target position, while the head-scatter radiation is modeled with a triple Gaussian distribution defined downstream of the target. The distances between the target and the head-scatter source, jaws, and MLC are model parameters. The scatter associated with the EPID is implicit in the model. Open beam images are predicted to within 1% of the maximum value across the image. Other MLC test patterns and intensity-modulated radiation therapy fluences are predicted to within 1.5% of the maximum value. The presented method was applied to the Varian aS500 EPID but is designed to work with any planar detector with sufficient spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

SU-E-T-190: Commissioning An Elekta VersaHD Linear Accelerator

Purpose: The purpose of this study is to report the dosimetric aspects of commissioning performed on an Elekta VersaHD linear accelerator with high dose rate flattening-filter-free (FFF) photon modes and electron modes. Methods: Acceptance and commissioning was performed on an Elekta VersaHD linac with 5 photon energies (6MV, 10MV, 18MV, 6FFF, 10FFF), 4 electron energies (6MeV, 9MeV, 12MeV, 15MeV) and 160 leaf (5mm wide) multi-leaf collimators (MLCs). Mechanical and dosimetric data was measured and evaluated. The measurements include percent depth doses (PDDs), inplane and crossplane profiles, head scatter factor (Sc), relative photon output factors (Scp), universal wedge transmission factor, MLC transmission factors, and electron cone factors. Results: Gantry, collimator, couch isocentricity measurements were within 1mm, 0.7mm and 0.7mm diameter respectively. The PDDs of 6FFF and 10FFF beams show deeper dmax and steeper fall-off with depth than the corresponding flattened beams. While flatness values of 6FFF and 10FFF normalized profiles were higher than the corresponding flattened beams, the symmetry values were almost identical. The crossplane penumbra values were higher than the inplane penumbra values for all the energies. The MLC transmission values were 0.5%, 0.6% and 0.6% for 6MV, 10MV, and 18MV photon beams. The electron PDDs, profiles and cone factors is validated by literature. Conclusion: The outcome of radiation treatment is directly related to the accuracy in the dose modeled in the treatment planning system which is based on the commissioned data. Commissioning data provided us a valuable insight into the dosimetric characteristics of the beam. This set of commissioning data can provide comparison data to others performing VersaHD commissioning thus improving patient safety.

60 APPLIED LIFE SCIENCES↗

Characterization of High-Intensity Laser Propagation in the Relativistic Transparent Regime through Measurements of Energetic Proton Beams

Experiments were performed to investigate the propagation of a high intensity (I{approx}10{sup 21} W cm{sup -2}) laser in foam targets with densities ranging from 0.9n{sub c} to 30n{sub c}. Proton acceleration was used to diagnose the interaction. An improvement in proton beam energy and efficiency is observed for the lowest density foam (n{sub e}=0.9n{sub c}), compared to higher density foams. Simulations show that the laser beam penetrates deeper into the target due to its relativistic propagation and results in greater collimation of the ensuing hot electrons. This results in the rear surface accelerating electric field being larger, increasing the efficiency of the acceleration. Enhanced collimation of the ions is seen to be due to the self-generated azimuthal magnetic and electric fields at the rear of the target.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-74: Commissioning of the Elekta VersaHD Linear Accelerator

Purpose: To present the commissioning process of recently-released Elekta VersaHD linear accelerator, equipped with Agility 160-leaf multileaf collimator and flattening-filter free (FFF) photon modes. Methods: In addition to routine QA procedures, we adopted an EPID-based method to perform the table rotation and Winston-Lutz tests, and a novel multiradiation isocenter alignment check. The beam data acquired include photon percent-depth dose (PDD) of 6X, 6XFFF, 10X, 10XFFF, and 15X in the field size from 2×2 to 40×40cm{sup 2}, profiles, collimator and phantom scatter factors (Sc and Sp), wedge factor, electron (6, 9, 12, and 15MeV) PDD and profiles, cone and cutout factors, and virtual SSD. Validation measurements were carried out in water tank to evaluate the accuracy of beam modeling by the Pinnacle planning system. End-to-End test and IMRT QA were performed to validate the overall delivery accuracy. A theoretical model has also been used to extract the primary dose ratio and off-axis beam softening effects by fitting photon beam profile measurements. Results: The PDDs of FFF beams with field size 10×10cm{sup 2} at 10cm depth, 100cm SSD were intentionally adjusted within 1% of the non-FFF beams. The photon profiles of 30×30cm{sup 2} at 10cm depth between non-FFF and FFF beams are very different, OAR(10)=0.74 and 0.63, respectively, for 6XFFF and 10XFFF. The collimator and phantom scatter factors of FFF beam demonstrated smaller variation with field sizes. The EPID-based method demonstrated the maximum deviation between the table rotation axis and radiation isocenter is within 1mm, and the radiation isocenters are within 0.4mm relative to that of 6X. The validation measurement shows less than 2% deviation between the measurement and Pinnacle modeling for most of the test conditions. Conclusion: To the best of our knowledge, this is the first study reporting the Elekta VersaHD commissioning experience, which can be a valuable reference for the radiotherapy community.

07 ISOTOPE AND RADIATION SOURCES↗

Shielding a monoenergetic photon source for nonproliferation applications analysis

Near-monoenergetic photon sources offer appealing improvements over broad-band bremsstrahlung sources when applied to challenges in nonproliferation efforts. The use of a laser-plasma accelerator offers electrons at the energies needed for multi-MeV Thomson sources in a compact form factor. Because these electrons have energy up to approximately 0.5 GeV, many energetic photons and neutrons are created as they are dumped out of the beam line. This fact creates challenges for performing experiments to demonstrate the advantages of such a photon source for nonproliferation applications in the short term, until effective methods for decelerating the electrons are developed. To mitigate these background particles for laboratory measurements, a system of beam dumps and secondary collimators has been designed. Once background flux is reduced to the lowest practical level, it is compared to the expected flux created by the source photon beam on a lead target. This simulation mimics a nonproliferation application by predicting measured flux off-axis from an interrogated high-Z object as a surrogate for special nuclear material. Background mitigation techniques are also expanded to a mobile interrogation case. Furthermore, these methods allow for demonstration of nonproliferation applications of near-monoenergetic photon sources and future deployment in the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functional representation of tissue phantom ratios for photon fields

Purpose: The tissue phantom ratio (TPR) is a common dosimetric quantity used in photon dose calculations. For small photon fields with side lengths less than 4 cm, TPR data hardly exist in literature. In this work, a self-contained functional representation of TPR is proposed, valid for the whole range of clinically relevant depth and field sizes. This is especially useful for small fields shaped by multileaf collimators. Methods: TPRs were measured for quadratic fields with side lengths between 0.4 and 18 cm. The measured data were fitted to a physically meaningful function taking electron buildup, buildup of scattered photons, beam attenuation, and beam hardening into account. The achievable accuracy was tested against measurement and data from the literature. Results: A set of parameters for the proposed function was derived for 6 and 10 MV beams. The comparison of the calculated and the measured data generally yielded a difference of less than 1%. For field sizes below 2 cm, a systematic discrepancy between the author's data and those from Cheng et al. [Med. Phys 34, 3149-3157 (2007)] was found. Conclusions: With the proposed model, TPRs can be calculated for the full range of field sizes and depths required by treatment planning system algorithms and monitor unit check programs with very high accuracy. The method is also useful in detecting and reducing errors in measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

Dealing with megawatt beams

The next generation of accelerators for MegaWatt proton, electron and heavy-ion beams puts unprecedented requirements on the accuracy of particle production predictions, the capability and reliability of the codes used in planning new accelerator facilities and experiments, the design of machine, target and collimation systems, detectors and radiation shielding and minimization of their impact on environment. Recent advances in code developments are described for the critical modules related to these challenges. Examples are given for the most demanding areas: targets, collimators, beam absorbers, radiation shielding, induced radioactivity and radiation damage.

43 PARTICLE ACCELERATORS↗

SU-F-T-561: Energy Dependence of a Scintillation Detector

Purpose: To investigate the response and dose rate dependence of a scintillation detector over a wide energy range. Methods: The energy dependence of W1 scintillation detector was tested with: 1) 50–225 keV beams generated by an animal irradiator, 2) a Leksell Gamma Knife Perfexion Co-60 source, 3) 6MV, 6FFF, 10FFF and 15MV photon beams, and 4) 6–20MeV electron beams from a linac. Calibrated linac beams were used to deliver 100 cGy to the detector at dmax in water under reference conditions. The gamma-knife measurement was performed in solid water (100 cGy with 16mm collimator). The low energy beams were calibrated with an ion chamber in air (TG-61), and the scintillation detector was placed at the same location as the ionization chamber during calibration. For the linac photon and electron beams, dose rate dependence was tested for 100–2400 and 100–800 MU/min. Results: The scintillation detector demonstrated strong energy dependence in the range of 50–225keV. The measured values were lower than the delivered dose and increased as the energy increased. Therapeutic photon beams showed energy independence with variations less than 1%. Therapeutic electron beams displayed the same sensitivity of ∼2–3% at their corresponding dmax depths. The change in dose-rate of photon and electron beams within the therapeutic energy range did not affect detector output (<0.5%). Measurements acquired with the gamma knife showed that the output data agreed with the delivered dose up to 3%. Conclusion: W1 scintillation detector output has a strong energy dependence in the diagnostic and orthovoltage energy range. Therapeutic photon beams exhibited energy independence with no observable dose-rate dependence. This study may aid in the implementation of a scintillation detector in QA programs by providing energy calibration factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the hot-cavity mode composition of an X-band overmoded relativistic backward wave oscillators

Overmoded RBWO (Relativistic Backward Wave Oscillators) is utilized more and more often for its high power capacity. However, both sides of SWS (Slow Wave Structure) of overmoded RBWO consist multi TM{sub 0n} modes; in order to achieve the design of reflector, it is essential to make clear of the mode composition of TM{sub 0n}. NUDT (National University of Defence Technology) had done research of the output mode composition in overmoded O-type Cerenkov HPM (High Power Microwave) Oscillators in detail, but in the area where the electron beam exists, the influence of electron beam must be taken into account. Hot-cavity dispersion equation is figured out in this article first, and then analyzes the hot-cavity mode composition of an X-band overmoded RBWO tentatively. The results show that in collimating hole, the hot-cavity mode analysis is more accurate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗