Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

LANL studies of ESD spark energy discharge through September 2019

Two concentric-sphere apparatuses were used to measure the energies deposited by electric sparks through air to calibrated loads. Both sets of spheres had clean, uninsulated metal surfaces. The 127-mm diameter pair of spheres had a gap of 10 mm and a capacitance of 52 pF. The maximum energy stored on these spheres was 12 mJ and the maximum energy delivered to the 50-mΩ load was 11 µJ, with or without inductance. This load energy amounted to 0.09% of the available input energy; the remainder of the input energy was expended in forming the spark. The second set of spheres was 330 mm in diameter with a gap of 14 mm and a capacitance of 240 pF. The maximum energy stored on these spheres was 71 mJ and the maximum energy delivered to the 50-mΩ load was 150 µJ without added inductance. This load energy was 0.27% of the input energy; again, the remainder of the input energy was expended in forming the spark. The inclusion of 250 nH and 500 nH inductances in the discharge path of the smaller spheres caused the current discharges to resonate, but had little effect on the maximum energies deposited in the loads. At the time of writing, inductances had not yet been added to the larger spheres. The magnitudes of the observed spark discharges were stochastic, so more than 1200 tests were required to develop the statistical bounds of the spark behavior, i.e., to estimate the worst case (highest likely) energy depositions in the loads. The action integrals of the current discharges $∫ i^2dt$ were found to be approximately independent of the load resistances for loads of less than ~1 Ω. Hence the energy deposition scaled with resistance as 207 µJ/Ω and 2.93 mJ/Ω for the two apparatuses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generation of Large-Volume High-Pressure Plasma by Spatio-Temporal Control of Space Charge

Due to the fundamental limitations of scaling, very little progress has been made towards achieving a large-volume dense non-equilibrium plasma near atmospheric pressures. Commercially available state-of-the art glow-like atmospheric plasma devices for industrial applications are either narrow tubes or wide slits with narrow openings. Often multiple sources are put together in various configurations to process larger surfaces. The traditional methods of exciting electrodes create spatially fixed electric fields. As a result, the space charge at atmospheric pressure tends to be spatially confined resulting in non-uniformity which eventually leads to instability as the discharge is scaled. Theoretical work done under this project showed that it is possible to generate a spatially rotating electric field by exciting a set of electrodes with phase staggered sinusoidal waveforms. The modeling and simulations were done using plasma fluid models. It was shown that such a field can produce a uniform plasma. At the conclusion of the project, experimental proof of concept with an eight-electrode system in various gases (Air, Helium and Argon) was demonstrated. Power measurements and spectral investigation show that the concept can be used to generate a uniform stable plasma. This plasma source has the potential of opening new applications of nonthermal plasma including combustion of carbon-free fuel. The current limitation of the proposed method in scaling to higher volume and pressure is the need for multiple high voltage amplifiers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of decelerating streamers in inhomogeneous atmosphere with implications for runaway electron generation

The dynamics of positive and negative streamers is numerically simulated in atmospheric pressure air in the range of parameters corresponding to the streamer deceleration and termination in the middle of the discharge gap. A detailed comparison with experiments in air at constant and variable density demonstrates good agreement between the 2D simulation results and the observations. It is shown that positive and negative streamers behave in radically different ways when decelerating and stopping. When the head potential drops, the negative streamer transits to the mode in which the propagation is due to the forward electron drift. In this case, the radius of the ionization wave front increases, whereas the electric field at the streamer head decreases further and the streamer stops. Its head diameter continues to increase due to the slow drift of free electrons in the residual under-breakdown field. On the contrary, the only advancement mechanism for a positive streamer with a decreasing head potential is a decrease in the effective radius of the ionization wave, leading to a local increase in the electric field. This mechanism makes it possible to compensate for the reduction in the efficiency of gas photoionization at small head diameters. A qualitative 1D model is suggested to describe streamer deceleration and stopping for different discharge polarities. Estimates show that, during positive streamer stopping, the local electric field at the streamer head can exceed the threshold corresponding to the transition of electrons to the runaway mode when the head potential (relative to the surrounding space) decreases to~1.2 kV in atmospheric pressure air. In this case, pulsed generation of a beam of runaway electrons directed into the channel of a stopping positive streamer can occur. The energy of the formed pulsed electron beam depends on the intensity of photoionization in front of the streamer head. This energy can vary from 700 V (when increasing the photoionization rate by a factor of 10 with respect to the value in atmospheric pressure air) to 2.6 kV (when decreasing the photoionization rate by a factor of 1000). It is possible that this behavior of decelerating positive streamers can explain the observed bursts of x-ray radiation during the streamer propagation in long air gaps.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗

Pumped Storage Hydropower Augmented with Pressurized Air: The Ground-Level Integrated Diverse Energy Storage (GLIDES) System — GLIDES System Configurations and Use Cases

Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.

13 HYDRO ENERGY↗

Techniques for controlling charging and/or discharging of batteries using a tanks-in-series model

In some embodiments, a battery management system is provided. The battery management system comprises a connector for electrically coupling a battery to the battery management system, at least one sensor configured to detect a battery state, a programmable chip configured to control at least one of charging and discharging of the battery, and a controller device. The controller device is configured to receive at least one battery state from the at least one sensor; provide the at least one battery state as input to a tanks-in-series model that represents the battery; and provide at least one output of the tanks-in-series model to the programmable chip for controlling at least one of charging and discharging of the battery.

25 ENERGY STORAGE↗

Kinetics of low temperature plasma assisted NH 3 /H 2 oxidation in a nanosecond-pulsed discharge

Ammonia (NH 3 ) has been widely recognized as one of the carbon-neutral fuels. However, ammonia combustion suffers low reactivity and high N 2 O/NO x emissions. Here, to overcome these issues, this work reports plasma assisted NH 3 /H 2 oxidation and unveils the kinetics of fuel oxidation and N 2 O/NO x formation by combining time-resolved laser diagnostics with plasma modeling. Firstly, we found that the NH 3 consumption is promoted with a H 2 blending ratio of 0.3, due to enhancements of H and OH formation by plasma assisted H 2 dissociation. Secondly, at a high reduced electric field, when the H 2 blending ratio increases, the NH 3 oxidation is promoted due to both the HO 2 formation and strong NO kinetic enhancement via NO-HO 2 and NO 2 -H pathways. In the meantime, it is shown that the NO mole fraction also increases with H 2 blending ratio, because the NO formation is enhanced via N( 2 D)-O 2 pathways, and the DeNO x chemistry is weakened with less NH 2 production. By contrast, at a lower reduced electric field, when the H 2 blending ratio increases, the decreased N( 2 D) formation does not produce enough NO to replenish the NO formation drop caused by lower NH 3 concentration. Thirdly, the reduced electric field non-monotonically affects fuel consumption and N 2 O/NO x formation by manipulating electron energy deposition pathways. The NH 3 consumption is maximized with an optimal reduced electric field where N 2 * excitation and O 2 dissociation are most efficient. When the reduced electric field deviates from its optimum, the NH 3 consumption decreases due to the discharge energy deposition to either vibrational excitation or dissociation of N 2 . The N 2 O/NO x emissions governed by the NH 3 oxidation follow the above NH 3 consumption trend.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filamentary surface plasma discharge flow length and time scales

Nanosecond surface dielectric barrier discharges (ns-SDBDs) are a class of plasma actuators that utilize a high-voltage pulse of nanosecond duration between two surface-mounted electrodes to create an electrical breakdown of air, along with rapid heating. These actuators usually produce multiple filaments when operated at high pulse frequencies, and the rapid heating leads to the formation of shock waves and complex flow fields. In this work we replicate a single filament of the ns-SDBDs and characterize the induced flow using velocity measurements from particle image velocimetry and density measurements from background-oriented schlieren. The discharge is produced by a high voltage electrical pulse between two copper electrodes on an acrylic base. A hot gas kernel characterizes the flow field formed close to the electrodes that expands and cools over time and a vortex ring that propagates away from the surface while entraining cold ambient fluid. The gas density deficit inside the kernel displays a power-law decay over time. Based on the observations, we develop a simplified theoretical model based on vortex-driven cooling and perform a scaling analysis to obtain the induced flow length and time scales. The results show that the cooling process's time scales correspond to a circulation-based time scale of the vortex ring, and the length scale of the kernel corresponds to the vortex ring radius. Furthermore, these findings can guide the choice of optimal filament spacing and pulse frequencies in the design, deployment, and operation of ns-SDBDs for flow control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Enhancing the performance of lithium oxygen batteries through combining redox mediating salts with a lithium protecting salt

Li–O 2 batteries have recently emerged to meet nowadays elevated electric energy demands. Redox mediators (RMs) for solution-inducing decomposition of discharge products are one approach to increase energy efficiency and reduce high overpotentials in these batteries. However, multiple obstacles hinder their usage such as redox shuttling, capacity fading, electrolyte degradation, etc. Herein, we present a new chemistry based on a combination of LiNO 3 , TEGDME and an ionic liquid that enables LiI (1 M) to lower the charge potential (3.5V) with a long cycle life of 270 cycles. 0.1 M LiI increases the cyclability up to 500 with a slightly increased charge potential (~4V) for a fixed capacity of 1000 mAh/g. Up to 100 cycles, this battery system retained ~95% Li 2 O 2 capacity with a ~0.8 V charge-discharge polarization gap. The addition of LiNO 3 to the electrolyte provides a protective solid electrolyte interface (SEI) on anode that works in synergy with the LiI RM. Moreover, we found that this electrolyte blend results in domain formation of ionic and neutral species enhancing the discharge and charge processes. Finally, DFT calculations provide a better understanding of the role of the anode SEI layer and the Li 2 O 2 decomposition promoted by the LiI during charge on the cathode.

25 ENERGY STORAGE↗

Fast photodiode arrays for high frequency fluctuation measurements of reconnecting flux ropes

An array of compact, high-bandwidth (>200 MHz) and low-cost optical photodiodes has been developed and implemented on the PHASe MApping (PHASMA) experiment. Using purpose-built electronics, an array of 16 photodetectors was constructed and used to monitor broadband (1–5 MHz) fluctuations in light intensity emitted by flux ropes undergoing electron-only magnetic reconnection. These measurements reveal a swath of oscillatory behavior, including wave propagation inward toward the diffusion region at approximately the local electron Alfvén speed. Custom 3D-printed collection optics and mounting hardware allow quick reconfiguration of the array for radial or axial measurements. The electronics design is flexible enough to be used with other current-sourcing transducers, such as avalanche photodiodes; silicon photomultipliers; and infrared, x-ray, and UV photodiodes. A noise-rejecting electrical layout allows for low-noise operation close to pulsed plasma discharges. A 16-channel, 64-pixel tomographic array was constructed and initial reconstructions are presented.

Instruments & Instrumentation↗

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High Temperature Gas Reactor Integrated Energy System Using Energy Storage as a Buffer for Hydrogen Production

Analysis of an integrated energy system producing hydrogen in a high temperature steam electrolysis system via steam provided by a sensible heat thermal energy storage system charged by a high temperature gas reactor. Preliminary results over a continuous discharge cycle and single charging cycle shows minimal reactor impact despite 25% electrical power load change. Hydrogen production is held constant with steam provided by the thermal energy storage system.

08 HYDROGEN↗

Electric field measurements of DC-driven positive streamer coronas using the E-FISH method

This paper reports on electric field measurements, using the electric field-induced second harmonic (E-FISH) method, sampling the spatial structure and temporal development of DC-driven positive streamer coronas in atmospheric-pressure air at relevant timescales to examine the self-pulsating behavior of the discharge. The discharge is triggered from a point-to-plate geometry and consists of transient coronas, which bridge the inter-electrode gap and pulsate at about 3 kHz, superimposed with a persisting glow corona. The measurements presented challenge the phenomenological explanation for the pulsations based on field recovery at the anode driven by the evacuation of positive ions by electric drift effects and hint at a propagating wave-like feature from the plate-cathode to the tip-anode.

42 ENGINEERING↗