Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXHALATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

252 records · Page 14

The Next Generation of Cold Immersion Dry Suit Design Evolution for Hypothermia Prevention

This new utility patent is an active design that relies on the lung's role as an organic heat exchanger for providing deep body core heating of air. It is based on the fact that the greatest heat loss mechanism for an insulated human body immersed in a cold water environment is due to heat loss through respiration. This innovation successfully merges two existing technologies (cold immersion suit and existing valve technologies) to produce a new product that helps prevent against the onset of hypothermia at sea. During normal operations, a human maintains an approximate body temperature of [98.6 F (37 C)]. A mechanism was developed to recover the warm temperature from the body and reticulate it in a survival suit. The primary intention is to develop an encompassing systems design that can both easily and cost effectively be integrated in all existing currently manufactured cold water survival suits, and as such, it should be noted that the cold water immersion suit is only used as a framework or tool for laying out the required design elements. At the heart of the suit is the Warm Air Recovery (WAR) system, which relies on a single, large Main Purge Valve (MPV) and secondary Purge Valves (PV) to operate. The main purge valve has a thin membrane, which is normally closed, and acts as a one-way check valve. When warm air is expelled from the lungs, it causes the main purge valve to open. Air forced from the MPV is dumped directly into the suit, thereby providing warmth to the torso, legs, and arms. A slight positive over-pressure in the suit causes warm waste air (or water if the suit is punctured) to be safely vented into the sea through large PVs located at the bottom of each arm and leg. The secondary purge valves act to prevent the buildup of large concentrations of CO2 gas and help guard against asphyxia. It is noted that the MPV causes the inhalation and exhalation cycles to be completely isolated from one another in the current suit design.

Galofaro, Joel↗

Sweat Rates During Continuous and Interval Aerobic Exercise: Implications for NASA Multipurpose Crew Vehicle (MPCV) Missions

Aerobic deconditioning is one of the effects spaceflight. Impaired crewmember performance due to loss of aerobic conditioning is one of the risks identified for mitigation by the NASA Human Research Program. Missions longer than 8 days will involve exercise countermeasures including those aimed at preventing the loss of aerobic capacity. The NASA Multipurpose Crew Vehicle (MPCV) will be NASA's centerpiece architecture for human space exploration beyond low Earth orbit. Aerobic exercise within the small habitable volume of the MPCV is expected to challenge the ability of the environmental control systems, especially in terms of moisture control. Exercising humans contribute moisture to the environment by increased respiratory rate (exhaling air at 100% humidity) and sweat. Current acceptable values are based on theoretical models that rely on an "average" crew member working continuously at 75% of their aerobic capacity (Human Systems Integration Requirements Document). Evidence suggests that high intensity interval exercise for much shorter durations are equally effective or better in building and maintaining aerobic capacity. This investigation will examine sweat and respiratory rates for operationally relevant continuous and interval aerobic exercise protocols using a variety of different individuals. The results will directly inform what types of aerobic exercise countermeasures will be feasible to prescribe for crewmembers aboard the MPCV.

Ryder, Jeffrey W.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment /Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, D.↗

Evaluation of an Impedance Threshold Device as a VIIP Countermeasure

Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs (Braslets) and lower body negative pressure (LBNP; Chibis) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure. The ITD works by providing up to 7 cm H2O (approximately 5 mmHg) resistance to inspiratory air flow, effectively turning the thorax into a vacuum pump upon each inhalation which lowers the intrathoracic pressure (ITP) and facilitates venous return to the heart. The ITD is FDA-approved and was developed to augment venous return to the central circulation and increase cardiac output during cardiopulmonary resuscitation (CPR) and in patients with hypotension. While the effect of ITD on CPR survival outcomes is controversial, the ITD's ability to lower ITP with a concomitant decrease in intracranial pressure (ICP) is well documented. A similar concept that creates negative ITP during exhalation (intrathoracic pressure regulator; ITPR) decreased ICP in 16 of 20 patients with elevated ICP in a hospital pilot study. ITP and central venous pressure (CVP) have been shown to decrease in microgravity however ITP drops more than CVP, indicating an increased transmural CVP. This could explain the paradoxical distention of jugular veins (JV) in microgravity despite lower absolute CVP and also suggests that JV transmural pressure is not dramatically elevated. Use of an ITD may lower JV pressure enough to remove or relieve cephalic venous congestion. During spaceflight experiments with Braslet thigh cuffs and modified (open-glottis) Mueller maneuvers, Braslets alone reduced cardiac preload but only reduced the internal JV (IJV) cross sectional area by 23%. The addition of Mueller maneuvers resulted in an IJV area reduction of 48%. This project will test if ITD essentially applies a Mueller maneuver with added negative ITP in every respiratory cycle, acting to: 1) reduce venous congestion in the neck and 2) potentially lower ICP. The expected mechanism of action is that in microgravity (or an analog) blood is relocated toward the heart from vasculature in the head and neck. Once validated, the ITD would be an exceptionally easy countermeasure to deploy and test on the ISS. Dosage could be altered though 1) duration of application and 2) inspiratory resistance set point. Effects could be additionally enhanced through co-application with other countermeasures such as thigh cuffs or LBNP.

Ebert, Douglas↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.

Meginnis, Ian M.↗

Improved Oxygen Sources for Breathing Apparatus

Since the 1920s, the only respiratory protection which coal miners had available during exposure to toxic or irrespirable environments was a filter self-rescuer that catalytically converted carbon monoxide (CO) to carbon dioxide (CO2). The deficiencies of this self-rescuer, which have been described elsewhere (37) led to the support by the Bureau of Mines of the development of a new generation of self-rescuers which utilized potassium superoxide (KO2) as the air-revitalization chemical. Since KO2 reacts with exhaled breath and releases oxygen (O2) while it absorbs CO2, the new self-rescuers were closed-circuit devices which isolated the miner from contact with toxic or irrespirable atmospheres. A device with a one-h duration developed by Lockheed under contract with the Bureau of Mines (18) utilized 1.5 Ib of KO2, weighed 4.54 Ib and measured 6.5 by 3.6 by 7.7 in. Since the earlier, filter self-rescuer weighed about 2.5 lb and was worn continuously by the miner, the one-h, KO2-based device represented a substantial addition to the equipment that the miner was accustomed to carrying and, therefore, was considered to be too large and too heavy.

Wood, Peter C.↗

Portable Unit for Metabolic Analysis

The Portable Unit for Metabolic Analysis measures human metabolic function. The compact invention attaches to the face of a subject and it is able to record highly time-resolved measurements of air temperature and pressure, flow rates during inhalation and exhalation, and oxygen and carbon dioxide partial pressure. The device is capable of `breath-by-breath` analysis and `within-breath` analysis at high temporal resolution.

Dietrich, Daniel L.↗

Sensor Integrated Pilot Mask for On-Board, Real-Time, Monitoring of Pilot Breathing Gas

A pilot's job is unique in the demands it places on the human body, and many conditions can seriously affect pilot performance, threatening mission completion and pilot safety. The gas in a flight mask contains key indicators of the pilot's physiological state, including oxygen inhaled and carbon dioxide exhaled, which can signal hypoxia, hyperoxia, hypocapnia, and hypercapnia. A fiber optic-based sensor system, integrated into the pilot mask, has been developed to monitor in real time, during flight, the pilot breathing gas levels. Monitoring the partial pressure of oxygen and carbon dioxide in the pilot mask supports real-time closed loop control of the on-board oxygen generation system, based on a direct reading of what the pilot is actually breathing. The pilot Mask Sensor (MASES) system incorporates luminescence sensors for pO2, pCO2, relative humidity, pressure, and temperature in a compact probe in the pilot mask; it is based on sensor technology developed for gas monitoring in space suit systems, in work supported by NASA under the Small Business Innovation Research program. Relevant requirements for the MASES system include sensor operation while wet, operation at reduced pressure, ability to withstand rapid decompression, operation in a pure oxygen atmosphere, low power consumption, a compact readout unit, and flexible miniature sensors; many of these requirements are shared with gas monitors in space suits. Data are presented from tests conducted with human subjects in an altitude chamber and in a centrifuge.

Delgado Alonso, Jesus↗

Hydrogen Recovery by Methane Pyrolysis to Elemental Carbon

Use of a Sabatier reactor to recover the oxygen from the carbon dioxide exhaled by the crew on the International Space Station has been limited by the loss of the hydrogen contained in the methane it generates. Maximizing the oxygen recovered requires the hydrogen to be recovered from the methane product and recycled back to the Sabatier reactor. We describe the use of a tailored methane pyrolysis reactor to completely recover this hydrogen. The carbon-containing byproduct is elemental carbon, which is generated in the form of easily handled, non-sooty material that may have various uses. The process of creating this tailored carbon vapor deposition process involved exploration of the effects of temperature, pressure, substrate design and other variables to develop a high yield process that cleanly generates the desired products. Reaction kinetics and kinetics modelling were used to specify the temperature, pressure and reactor volume required to achieve the target conversion and to assure that the final average density was as high as possible. Reactor design included the selection of materials that will survive the high temperatures and environment in the pyrolysis reactor, and thermal modeling to achieve the required temperatures with minimum power consumption. The successful construction and demonstration of a brassboard prototype will allow the results of the chemical, thermal and mechanical models to be validated and should provide a useful alternative for a completely closed loop ECLS system. Integration of this technology with state-of-the-art (SOA) Sabatier hardware on ISS requires a complete understanding of the effects of impurities in the product hydrogen on the Sabatier catalyst. SOA Sabatier catalyst was evaluated over short and long-term exposure to anticipated contaminants to identify effects.

Yates, Stephen F.↗

Hydrogen Recovery by Methane Pyrolysis to Elemental Carbon

Use of a Sabatier reactor to recover the oxygen from the carbon dioxide exhaled by the crew on the International Space Station has been limited by the loss of the hydrogen contained in the methane it generates. Maximizing the oxygen recovered requires the hydrogen to be recovered from the methane product and recycled back to the Sabatier reactor. We describe the use of a tailored methane pyrolysis reactor to completely recover this hydrogen. The carbon-containing byproduct is elemental carbon, which is generated in the form of easily handled, non-sooty material that may have various uses. The process of creating this tailored carbon vapor deposition process involved exploration of the effects of temperature, pressure, substrate design and other variables to develop a high yield process that cleanly generates the desired products. Reaction kinetics and kinetics modelling were used to specify the temperature, pressure and reactor volume required to achieve the target conversion and to assure that the final average density was as high as possible. Reactor design included the selection of materials that will survive the high temperatures and environment in the pyrolysis reactor, and thermal modeling to achieve the required temperatures with minimum power consumption. The successful construction and demonstration of a brassboard prototype will allow the results of the chemical, thermal and mechanical models to be validated and should provide a useful alternative for a completely closed loop ECLS system. Integration of this technology with state-of-the-art (SOA) Sabatier hardware on ISS requires a complete understanding of the effects of impurities in the product hydrogen on the Sabatier catalyst. SOA Sabatier catalyst was evaluated over short and long-term exposure to anticipated contaminants to identify effects.

Yates, Stephen F.↗

Noninvasive Breath Analysis Using NASA E-Nose Technology for Health Assessment

Clinical breath analysis is based on the fact that many important metabolites and biomarker molecules are present at detectable levels in exhaled breath, and many of these molecules correlate with human disease or correlate with physiological states that could lead to a decline in health. Presented is a technology that utilizes an array of chemical sensors combined with humidity, temperature and pressure for real time breath analysis to correlate the chemical information in the breath with the state and functioning of different human organs. For example, a marker for pulmonary inflammation processes of the lower respiratory tract, e.g. asthma, is the increase of the nitrogen oxide (NO) concentration in breath. Other volatile biomarkers may correlate with infectious process, metabolic conditions and inflammatory diseases, such as traumatic brain injury (TBI). This technology is also called "electronic nose" (E-Nose) in the sense that the device can mimic human nose to smell odors using a pattern recognition technique to analyze the sensor array data. Breath sampling is non-invasive and can be analyzed in real-time.

Li, Jing↗

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗

Standard Testing Procedure for Quantifying Breathing Gas Carbon Dioxide Partial Pressure for Extravehicular Activity and Launch, Entry, Survival Pressure Suits

This standard test and analysis protocol establishes the procedure for determining the partial pressure of inspired carbon dioxide (PICO2) exposure level experienced by persons operating a pressurized suit. The purpose of this Standard Testing Procedure (STP) is to describe the test conditions and procedures necessary to acquire data in support of certification that manufacturer submitted Extravehicular Activity (EVA) and/or Launch, Entry, Survival (LES) suit designs maintain safe levels of carbon dioxide (CO2) in the helmet during suited operations. The STP shall be used to measure the in-suit inhaled and exhaled dry-gas partial pressure of CO2 (PCO2), followed by calculation of the water vapor saturated PICO2 during the inhalation portion of the breathing cycle, while a human test subject is performing work at levels anticipated during suited operations in ground and flight environments. The procedure is designed to test the evaluated suit on a human test subject as a dynamic system, generate repeatable results under defined laboratory conditions, and perform consistent analysis on acquired samples.This STP is used to evaluate space suits in a hyperbaric environment (above atmospheric pressure). Changes would need to be made to the test equipment/setup to accommodate a hypobaric environment. There is no specific EVA or LES suit performance requirement to meet or pass/fail criteria associated with this STP.

Bekdash, Omar↗

Optimizing CO2 Washout in the Exploration Extravehicular Mobility Unit

CO2 Washout refers to the suit’s ability to remove exhaled metabolic waste gases from the helmet before the crewmember’s next consecutive inhale. Efficient removal of such waste gases is paramount as it prevents crewmember fatigue as well as hypoxia. A variety of hardware and conditions inside the suit contribute to the efficiency at which CO2 washout occurs including (but not limited to) the shape of the helmet bubble, crewmember head position, breathing type and metabolic rate, the configuration of the oxygen vent inside the helmet, etc. While designing the oxygen vent inside the helmet of the Extravehicular Mobility Unit (xEMU) both nominal and contingency scenarios were considered in order to optimize CO2 washout. During nominal Extravehicular Activity (EVA), the pressure gradient created by the vent loop inlets located in the arms and legs of the Pressure Garment Subsystem (PGS) aids in washout by pulling the metabolic waste out of the helmet. However, in the event that a contingency scenario occurs, where the flow of oxygen to the crewmember, or the removal of metabolic waste is disrupted, the primary oxygen regulator fails open and removal of waste is no longer performed by the vent loop, but rather by the Low Flow Purge Valve (LFPV) located in the helmet. The paper to follow will provide an overview of the analysis, design, and testing performed to optimize washout for both nominal and contingency scenarios for the most current design iteration of the xEMU.

Margot Steely↗

Simulation of Radon-222 with the GEOS-Chem Global Model: Emissions, Seasonality, and Convective Transport

Radon-222 (Rn-222) is a short-lived radioactive gas naturally emitted from land surfaces and has long been used to assess convective transport in atmospheric models. In this study, we simulate Rn-222 using the GEOS-Chem chemical transport model to improve our understanding of Rn-222 emissions and surface concentration seasonality and characterize convective transport associated with two Goddard Earth Observing System (GEOS) meteorological products, the Modern-Era Retrospective analysis for Research and Applications (MERRA) and GEOS Forward Processing (GEOS-FP). We evaluate four global Rn-222 emission scenarios by comparing model results with observations at 51 surface sites. The default emission scenario in GEOS-Chem yields a moderate agreement with surface observations globally (68.9 % of data within a factor of 2) and a large underestimate of winter surface Rn-222 concentrations at Northern Hemisphere midlatitudes and high latitudes due to an oversimplified formulation of Rn-222 emission fluxes (1 atom cm−2 s−1 over land with a reduction by a factor of 3 under freezing conditions). We compose a new global Rn-222 emission scenario based on Zhang et al. (2011) and demonstrate its potential to improve simulated surface Rn-222 concentrations and seasonality. The regional components of this scenario include spatially and temporally varying emission fluxes derived from previous measurements of soil radium content and soil exhalation models, which are key factors in determining Rn-222 emission flux rates. However, large model underestimates of surface Rn-222 concentrations still exist in Asia, suggesting unusually high regional Rn-222 emissions. We therefore propose a conservative upscaling factor of 1.2 for Rn-222 emission fluxes in China, which was also constrained by observed deposition fluxes of 210Pb (a progeny of Rn-222). With this modification, the model shows better agreement with observations in Europe and North America (> 80 % of data within a factor of 2) and reasonable agreement in Asia (close to 70 %). Further constraints on Rn-222 emissions would require additional concentration and emission flux observations in the central United States, Canada, Africa, and Asia. We also compare and assess convective transport in model simulations driven by MERRA and GEOS-FP using observed Rn-222 vertical profiles in northern midlatitude summer and from three short-term airborne campaigns. While simulations with both GEOS products are able to capture the observed vertical gradient of Rn-222 concentrations in the lower troposphere (0–4 km), neither correctly represents the level of convective detrainment, resulting in biases in the middle and upper troposphere. Compared with GEOS-FP, MERRA leads to stronger convective transport of Rn-222, which is partially compensated for by its weaker large-scale vertical advection, resulting in similar global vertical distributions of Rn-222 concentrations between the two simulations. This has important implications for using chemical transport models to interpret the transport of other trace species when these GEOS products are used as driving meteorology.

Bo Zhang↗

Enhanced Cover Assessment Project:Soil Manipulation and Revegetation Tests

The U.S. Department of Energy Office of Legacy Management is evaluating methods to enhance natural changes that are essentially converting conventional disposal cell covers for uranium mill tailings into water balance covers. Conventional covers rely on a layer of compacted clayey soil to limit exhalation of radon gas and percolation of rainwater. Water balance covers rely on a less compacted soil “sponge” to store rainwater, and on soil evaporation and plant transpiration (evapotranspiration) to remove stored water and thereby limit percolation. Over time, natural soil-forming and ecological processes are changing conventional covers by increasing hydraulic conductivity, loosening compaction, and increasing evapotranspiration. The rock armor on conventional covers creates a favorable habitat for vegetation by slowing soil evaporation, increasing soil water storage, and trapping dust and organic matter, thereby providing the water and nutrients needed for plant germination, survival, and sustainable transpiration. Goals and Objectives Our overall goal is to determine if allowing or enhancing these natural changes could improve cover performance and reduce maintenance costs over the long term. This test pad study focuses on cover soil hydrology and ecology. Companion studies are evaluating effects of natural and enhanced changes in covers on radon attenuation, erosion, and biointrusion. We constructed a test cover at the Grand Junction disposal site to evaluate soil manipulation and revegetation methods. The engineering design, construction, and properties of the test cover match the upper three layers of the nearby disposal cell cover: a 1-foot armoring of rock riprap, a 6-inch bedding layer of coarse sand and gravel, and a 2-foot protection layer of compacted fine soil. The test cover does not have a radon barrier—cover enhancement tests leave the radon barrier intact. We tested furrowing and ripping as means for creating depressions parallel to the slope contour, bringing soil up into the rock riprap layer, and loosening and blending compacted fine soil with coarse sand and gravel layers. Objectives of these manipulations include (1) enhancing root growth, (2) increasing seed-soil contact, (3) catching runoff water for plant germination and growth, (4) increasing soil water storage capacity, and (5) enhancing deep drying by disrupting the capillary barrier at the interface of the bedding and protection layers.

54 ENVIRONMENTAL SCIENCES↗

Study of radon concentration in wetland Mediterranean water using continuous monitoring - 25416

Radon is a radioactive gas that comes from the uranium and radium decay. It is considered the second cause of lung cancer in nonsmokers by the World Health Organization (WHO). Most studies focus on radon levels in air, which comes mainly from soil. Unfortunately, just some of them focus on radon in water which exposure is mainly due to radon inhalation when it is exhaled from water. In order to develop a methodology for radon measurement in water, this work compares two different techniques. The measurements have been done at Peniscola marsh, a location in the Valencian Community where significant radon concentrations have been measured in previous works. Furthermore, measurements in the Waste-Water-Treatment Plant (WWTP) near the marsh, where high radon concentrations have been found in air, are analyzed to confirm if they can be related to radon presence in water. (authors)

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-238: First-Order Approximation of Time-Resolved 4DMRI From Cine 2DMRI and Respiratory-Correlated 4DMRI

Purpose: Cine 2DMRI is useful in MR-guided radiotherapy but it lacks volumetric information. We explore the feasibility of estimating timeresolved (TR) 4DMRI based on cine 2DMRI and respiratory-correlated (RC) 4DMRI though simulation. Methods: We hypothesize that a volumetric image during free breathing can be approximated by interpolation among 3DMRI image sets generated from a RC-4DMRI. Two patients’ RC-4DMRI with 4 or 5 phases were used to generate additional 3DMRI by interpolation. For each patient, six libraries were created to have total 5-to-35 3DMRI images by 0–6 equi-spaced tri-linear interpolation between adjacent and full-inhalation/full-exhalation phases. Sagittal cine 2DMRI were generated from reference 3DMRIs created from separate, unique interpolations from the original RC-4DMRI. To test if accurate 3DMRI could be generated through rigid registration of the cine 2DMRI to the 3DMRI libraries, each sagittal 2DMRI was registered to sagittal cuts in the same location in the 3DMRI within each library to identify the two best matches: one with greater lung volume and one with smaller. A final interpolation between the corresponding 3DMRI was then performed to produce the first-order-approximation (FOA) 3DMRI. The quality and performance of the FOA as a function of library size was assessed using both the difference in lung volume and average voxel intensity between the FOA and the reference 3DMRI. Results: The discrepancy between the FOA and reference 3DMRI decreases as the library size increases. The 3D lung volume difference decreases from 5–15% to 1–2% as the library size increases from 5 to 35 image sets. The average difference in lung voxel intensity decreases from 7–8 to 5–6 with the lung intensity being 0–135. Conclusion: This study indicates that the quality of FOA 3DMRI improves with increasing 3DMRI library size. On-going investigations will test this approach using actual cine 2DMRI and introduce a higher order approximation for improvements. This study is in part supported by NIH (U54CA137788 and U54CA132378)

60 APPLIED LIFE SCIENCES↗