Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRIC NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

CRADA Number NFE-24-10110 with Qubit Engineering Inc. (CRADA Final Report)

Over the past year, the Qubit Engineering team has pushed the frontiers of power‑grid optimization, working in close collaboration with Oak Ridge National Laboratory (ORNL) and the Tennessee Valley Authority (TVA). Their progress is reflected in three newly submitted conference papers, “Unified Relational GNN Architecture for AC Optimal Power Flow Calculations in Electric Grids,” “Graph‑Based Attention Mechanisms for Solving the AC Optimal Power Flow Problem in Electrical‑Power Networks,” and “Enhanced Power‑Grid Maintenance Planning and Quantum‑Inspired Combinatorial Prospects.” These publications showcase state‑of‑the‑art graph‑neural‑network methods for AC‑OPF and novel quantum‑inspired heuristics for maintenance scheduling. Beyond the academic results, the Qubit team has converted the research into two production‑grade tools built on TVA data: Neuro‑Grid, an AI‑driven power‑flow simulator that provides instant, interactive full‑grid load‑flow visualizations, and Quanta‑Grid, a quantum‑inspired maintenance‑scheduling engine to support logistics optimization for power utilities. Together, these advances demonstrate how Qubit’s partnership with ORNL and TVA is delivering practical, physics‑grounded analytics for next‑generation grid management.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Charging Up in King County, Washington

King County, Washington is spearheading a regional effort to develop a network of electric vehicle charging stations. It is also improving its vehicle fleet and made significant improvements to a low-income senior housing development.

25 ENERGY STORAGE↗

Quantifying the Impact of Unavailability in Cyber-Physical Environments

The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability. This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.

Availability↗

Secured control of circuit breakers in a digital substation

Methods and systems for secured control of circuit breakers in an electric power substation against undesired direct operation. Consequences of a malicious action are prevented or mitigated using a validation approach that either blocks the command or ensures a negligible effect on system operation. An example method, suitable for implementation in a monitoring device in an electric power substation, includes receiving a command to open or close a circuit breaker. In response, one or more state parameters for the electric power network that comprises the substation are then predicted, the predicted state parameters reflecting an operating state for the network under the assumption that the received command is executed. The method further comprises comparing the predicted one or more state parameters to corresponding operational limits. Execution of the command is then blocked, in response to determining that one or more of the predicted state parameters violate the corresponding operational limits.

Kondabathini, Anil↗

Tracking Aging in Nuclear Electrical Cable Polymers

The electrical cable network is the nerve center of a nuclear plant, providing power, instrumentation and control of critical systems during operation, planned outage, and during design basis, unplanned outage events. It is therefore important to manage cable system health through awareness of local environments adverse to cable longevity, monitoring of cable condition, and predictive understanding of cable degradation [1-3]. Nondestructive methods can be used to assess the condition of the full length of installed cables and of localized cable regions to support cable repair and replacement planning decisions [4-5]. Informed knowledge of the effects of environment on cable performance over time combined with cable state assessment data can minimize costs associated with cable management by both avoiding outages and ramifications from unexpected cable failure and by avoiding premature replacement of functional cables. In this work, the aging behavior of commonly found nuclear cable insulation and jacketing materials is investigated along with established and emerging methods for locating and quantifying cable degradation. Ethylene-propylene rubber (EPR) and chlorinated polyethylene (CPE), examples of prevalent insulation and jacket materials used in nuclear power plants (NPPs), are thermally aged at elevated temperature to induced material changes similar to those experienced by cable material under long term service conditions. Destructive and nondestructive laboratory tests are used to follow changes in the materials with aging toward establishing predictive capabilities to help extend the life of installed nuclear cables and reduce cable management operational costs.

Cable aging, EPR, CPE, NDE, nuclear↗

Technical Assistance 101 - How Can the Joint Office Support You?

The Joint Office of Energy and Transportation (Joint Office), in partnership with the Federal Highway Administration (FHWA), National Renewable Energy Laboratory (NREL), the Federal Transit Administration (FTA), and the Environmental Protection Agency (EPA), provides free technical assistance on the planning, deployment, operation, and maintenance of a national network of electric vehicle chargers, zero-emission fueling infrastructure, and zero-emission transit and school buses. This help sheet shares how technical assistance can support stakeholders.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Public EV Charging Station Site Selection Checklist

The Joint Office of Energy and Transportation (Joint Office) provides technical assistance on planning and implementation of a national network of electric vehicle (EV) chargers and zero-emission fueling infrastructure, as well as zero-emission transit and school buses. There are several considerations that should be addressed when selecting a site for EV charging stations. The following is a checklist to assist with site selection for publicly available EV charging stations.

ADVANCED PROPULSION SYSTEMS↗

Stochastic Strategic Participation of Active Distribution Networks With High-Penetration DERs in Wholesale Electricity Markets

With the increasing penetration of distributed energy resources (DERs), traditional distribution networks as load-serving entities in wholesale electricity markets, now evolve towards active distribution networks (ADNs) which can proactively participate in wholesale markets by optimally controlling the DERs in their networks. A stochastic bilevel optimization model is proposed in this paper for the strategic participation of ADNs and DERs to provide energy and grid services in wholesale electricity markets. The bilevel optimization model can capture the interactions between the ADN and the wholesale energy and ancillary service markets, considering the uncertainties of DERs in the ADN. In the upper-level model, the ADN makes optimal decisions on energy and reserve bidding considering the availability, uncertainties, and flexibility of DERs. The joint energy and reserve market-clearing of the independent system operator (ISO) is modeled as the lower-level problem. Using strong duality theory and Karush-Kuhn Tucker (KKT) conditions, the proposed bilevel optimization problem is reformulated as mathematical programming with equilibrium constraints (MPEC) problem and further converted into a computationally-solvable mixed-integer second-order-cone programming (MISOCP) model. The simulation results demonstrate the effectiveness of the model and the interactions between an ADN and wholesale electricity markets.

active distribution network↗

Refueling infrastructure planning in intercity networks considering route choice and travel time delay for mixed fleet of electric and conventional vehicles

The range anxiety has been a major factor that affects the market acceptance of electric vehicles. Even with the recent development of battery technologies, a lack of charging stations and range anxiety are still significant concerns, specifically for intercity trips. This calls for more investments in building charging stations and advancing battery technologies to increase the market share of electric vehicles and improve sustainability. This study suggests a configuration for plug-in electric vehicle charging infrastructure to support long-distance intercity trips of electric vehicles at the network level. A model is proposed to minimize the total system cost including infrastructure investment (building charging stations/spots) and travel time delays (charging time, waiting time in the queue, and detour time to access charging stations). This study fills existing gaps in the literature by capturing realistic patterns of travel demand and considering flow-dependent charging delays at charging stations. Furthermore, the proposed model, which is formulated as a mixed-integer program with nonlinear constraints, solves the optimization problem at the network level. At the network level, impacts of charging station locations on the traffic assignment problem with a mixed fleet of electric and conventional vehicles need to be considered. To this end, a traffic assignment module is integrated with a simulated annealing algorithm. The numerical experiments show a satisfactory application of the model for a full-scale case study (intercity network in Michigan). The solution quality and efficiency of the proposed solution algorithm are evaluated against those of an enumeration approach for a small case study. The results suggest that even for the current market share and charging stations’ setting, a significant investment is needed to support intercity trips without range anxiety issues and with acceptable delays. Additionally, through sensitivity analyses, the required infrastructure and battery investments to support intercity trips with acceptable delays are established for hypothetical increased market shares and battery size in the future.

42 ENGINEERING↗

Asset Monitoring using Smart Sensing and Advanced Analytics for the Distribution Network

As the electric grid transitions into a highly distributed and intelligent grid, electric utilities are becoming increasingly concerned with monitoring the health and performance of their distribution assets. As Internet of Things technologies and data analytics become inexpensive and ubiquitous, low-cost asset monitoring becomes more feasible. Moreover, using edge analytics, computations can be off-loaded to these intelligent sensors to report only actionable information to the cloud. This needs to be done in a highly distributed manner using non-intrusive sensors and device physics that seamlessly integrates with legacy infrastructure. Here, this paper reviews existing sensor based solutions, identifies t heir issues, proposes a novel solution by exploring the required attributes and proposes an approach for low-cost distribution transformer health monitoring.

Asset monitoring↗

Towards High Performance Discrete-Event Simulations of Smart Electric Grids

Future electric grid technology is envisioned on the notion of a smart grid in which responsive end-user devices play an integral part of the transmission and distribution control systems. Detailed simulation is often the primary choice in analyzing small network designs, and the only choice in analyzing large-scale electric network designs. Here, we identify and articulate the high-performance computing needs underlying high-resolution discrete event simulation of smart electric grid operation large network scenarios such as the entire Eastern Interconnect. We focus on the simulator's most computationally intensive operation, namely, the dynamic numerical solution for the electric grid state, for both time-integration as well as event-detection. We explore solution approaches using general-purpose dense and sparse solvers, and propose a scalable solver specialized for the sparse structures of actual electric networks. Based on experiments with an implementation in the THYME simulator, we identify performance issues and possible solution approaches for smart grid experimentation in the large.

99 GENERAL AND MISCELLANEOUS↗

Self-assembled tunable networks of sticky colloidal particles

Self-assembled tunable networks of microscopic polymer fibers ranging from wavy colloidal "fur" to highly interconnected networks are created from polymer systems and an applied electric field. The networks emerge via dynamic self-assembly in an alternating (ac) electric field from a non-aqueous suspension of "sticky" polymeric colloidal particles with a controlled degree of polymerization. The resulting architectures are tuned by the frequency and amplitude of the electric field and surface properties of the particles.

36 MATERIALS SCIENCE↗

Understanding the doping effects on the structural and electrical properties of ultrathin carbon nanotube networks

Similar to other semiconductor technology, doping of carbon nanotube (CNT) thin film is of great significance for performance improvement or modification. However, it still remains a challenge to seek a stable and effective dopant. In this paper, we unitize several spectroscopic techniques and electrical characterizations under various conditions to investigate the effects of typical dopants and related methods. Nitric acid (HNO{sub 3}) solution, I{sub 2} vapor, and CuI nanoparticles are used to modify a series of ultrathin CNT networks. Although efficient charge transfer is achieved initially after doping, HNO{sub 3} is not applicable because it suffers from severe reliability problems in structural and electrical properties, and it also causes a number of undesired structural defects. I{sub 2} vapor doping at 150 °C can form some stable C-I bonding structures, resulting in relatively more stable but less efficient electrical performances. CuI nanoparticles seem to be an ideal dopant. Photonic curing enables the manipulation of CuI, which not only results in the construction of novel CNT-CuI hybrid structures but also encourages the deepest level of charge transfer doping. The excellent reliability as well as processing feasibility identify the bright perspective of CNT-CuI hybrid film for practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data Files for “The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure"

This data set includes modeling results from “The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure” including region-specific [i.e., national, state, and core-based statistical area (CBSA)—cities/towns] electric vehicle supply equipment (EVSE) port count requirements in 2025 and 2030 for multiple scenarios described in the study. Please cite as: Wood, E., B. Borlaug, M. Moniot, D.-Y. Lee, Y. Ge, F. Yang, and Z. Liu. 2023. The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-85654.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Forecasting of Electric Loads Using Nonlinear Autoregressive Artificial Neural Networks with Exogenous Vector Inputs

Short-term load forecasting is crucial for the operations planning of an electrical grid. Forecasting the next 24 h of electrical load in a grid allows operators to plan and optimize their resources. The purpose of this study is to develop a more accurate short-term load forecasting method utilizing non-linear autoregressive artificial neural networks (ANN) with exogenous multi-variable input (NARX). The proposed implementation of the network is new: the neural network is trained in open-loop using actual load and weather data, and then, the network is placed in closed-loop to generate a forecast using the predicted load as the feedback input. Unlike the existing short-term load forecasting methods using ANNs, the proposed method uses its own output as the input in order to improve the accuracy, thus effectively implementing a feedback loop for the load, making it less dependent on external data. Using the proposed framework, mean absolute percent errors in the forecast in the order of 1% have been achieved, which is a 30% improvement on the average error using feedforward ANNs, ARMAX and state space methods, which can result in large savings by avoiding commissioning of unnecessary power plants. The New England electrical load data are used to train and validate the forecast prediction.

30 DIRECT ENERGY CONVERSION↗