Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic

X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization and equalization of intensity-modulated voltage sensors

We test fiber-optic voltage sensors based on reflection from a piezoelectric transducer. Detailed characterization confirms a 60 dB dynamic range, and our equalization approach accurately recovers transient excitations, indicating the versatility of this sensor design in electric grid monitoring.

Lukens, Joseph↗

Methods and Experiences for Developing Abstractions for Data-intensive, Scientific Applications

Developing software for scientific applications that require the integration of diverse types of computing, instruments, and data present challenges that are distinct from commercial software. These applications require scale, and the need to integrate various programming and computational models with evolving and heterogeneous infrastructure. Pervasive and effective abstractions for distributed infrastructures are thus critical; however, the process of developing abstractions for scientific applications and infrastructures is not well understood. While theory-based approaches for system development are suited for well-defined, closed environments, they have severe limitations for designing abstractions for scientific systems and applications. The design science research (DSR) method provides the basis for designing practical systems that can handle real-world complexities at all levels. In contrast to theory-centric approaches, DSR emphasizes both practical relevance and knowledge creation by building and rigorously evaluating all artifacts. In this work, we show how DSR provides a well-defined framework for developing abstractions and middleware systems for distributed systems. Specifically, we address the critical problem of distributed resource management on heterogeneous infrastructure over a dynamic range of scales, a challenge that currently limits many scientific applications. We use the pilot-abstraction, a widely used resource management abstraction for high-performance, high throughput, big data, and streaming applications, as a case study for evaluating the DSR activities. For this purpose, we analyze the research process and artifacts produced during the design and evaluation of the pilot-abstraction. We find DSR provides a concise framework for iteratively designing and evaluating systems. Finally, we capture our experiences and formulate different lessons learned.

97 MATHEMATICS AND COMPUTING↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Faraday Michelson Interferometers for Signal Demodulation of Fiber-Optic Sensors

We developed an all-fiber-based optical demodulator for the signal interrogation of low-coherence fiber-optic Fabry–Perot interferometric sensors. The optical demodulator consists of a Michelson interferometer implemented by using a 3×3 fiber coupler and two fiber-coupled Faraday reflectors with tunable fiber delay lines. The demodulator's output contains two optical interference signals with a constant phase shift and the output shows no sensitivity to the polarization variation in the light source or fibers. A digital phase recovery algorithm is used to extract the measurand information from the phase-shifted signals at high accuracy, high dynamic range, and high stability. The optical demodulator has been applied to the measurement of high-frequency vibrations and strains using fiber-optic sensors.

47 OTHER INSTRUMENTATION↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗

Constraining the Multiscale Structure of Geophysical Fields in Machine Learning: The Case of Precipitation

The use of deep-learning algorithms for estimating the value of geophysical variables from remotely sensed information is rapidly expanding. The typical objective function minimized in such algorithms is the mean square error (MSE), which is known to lead to smooth estimates with compressed dynamical range as compared to the true distribution of the variable of interest. Here, we introduce and evaluate alternative objective functions, focusing on the retrieval of precipitation rates from satellite passive microwave radiometric measurements using a deep convolutional neural network. For this testbed application, the results show that explicitly imposing the preservation of the statistical distribution and spatial wavelet power spectrum of the target variable allows to accurately reproduce extreme values and sharp gradients across multiple scales in this study.

58 GEOSCIENCES↗

Equalization of Intensity-Modulated Fiber-Optic Voltage Sensors for Power Distribution Systems

We test fiber-optic voltage sensors based on optical reflection from a piezoelectric transducer. Our specific devices possess a 2 kHz fundamental resonance, and we verify a readily usable frequency band from approximately 10 Hz to 3 kHz, with a dynamic range of 60 dB for a detection system integrating over this entire band. Additionally, we demonstrate a digital signal processing approach to equalize the measured frequency response, enabling accurate retrieval of short-pulse inputs. These results suggest the value and applicability of intensity-modulated fiber-optic voltage sensors for measuring both steady-state waveforms and broadband transients which, coupled with the straightforward and compact design of the sensors, should make them effective tools in electric grid monitoring.

42 ENGINEERING↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Methods and apparatus for comprehensive characterization of performance attributes and damage thresholds of ultrafast laser optics

It is presently well understood that the operational performance limits of optics are determined by three fundamental attributes: the initiation of laser-induced damage, the growth of damage sites, and the transient (nondamaging) modification of optical parameters. The comprehensive characterization of the performance limitations of ultrafast optics requires consideration of all three fundamental attributes. Here, the vast majority of literature to date, however, has focused primarily on damage-initiation and testing systems that are largely focused on determining the damage-initiation threshold under single- and multipulse excitation. In this work, we discuss a testing apparatus that was designed to offer the capability to adequately characterize all three of these performance attributes under femtosecond, near-infrared laser irradiation. Key aspects of methodology are discussed, including high-dynamic-range energy control, variable beam size, wavelength tunability, B-integral management, and functional performance characterization to explore the true operational limits of the components. Example results for a metal-dielectric mirror demonstrate the test station’s operation.

42 ENGINEERING↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Quantum sensing using a qubit for the detection of ionizing radiation

Quantum sensing utilizes the inherent sensitivity of a quantum system to external stimuli. Our goal is to leverage this sensitivity to develop a quantum sensor designed for the detection of ionizing radiation. Here we report on the design, fabrication, and measurement of a new quantum device for hard x-ray and gamma-ray detection. Our quantum device is based on a superconducting quantum bit (qubit) with superconducting tunnel junctions as the core device elements. We describe our experimental investigation directed toward the detection metrics of energy resolution, dynamic range, and active area. In contrast to existing superconducting detectors, the active area per qubit may be much larger than the physical area of the tunnel junctions or the physical area of the qubit device, due to the sensitivity of quantum coherence to ionizing radiation deposition within a radius on the millimeter or centimeter scale. Furthermore, our experimental design enables an ionizing radiation source at room temperature to be detected by our quantum sensor at low temperature.

qubit↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TransPlatformer

We propose TransPlatformer for translating toxicogenomics from one platform to another. Transcriptomic profiling has evolved through multiple generations of technology, from microarrays (e.g., Affymetrix, CodeLink) to more recent high-throughput sequencing and targeted panels such as S1500+. Microarrays, which dominated gene expression studies in the early 2000s, provided affordable and high-throughput transcript quantification but suffered from cross-hybridization issues and limited dynamic range . RNA-Seq, introduced in the late 2000s, revolutionized transcriptomics by enabling unbiased and comprehensive gene expression analysis, albeit at higher costs and computational demands . Despite advances, many studies rely on historical microarray data, necessitating the translation of legacy data into modern platforms to ensure continuity and comparability. This translation is complicated by factors such as platform-specific probe design, differences in transcript coverage, and batch effects . Existing methods for cross-platform mapping include statistical normalization, machine learning models, and biological anchoring approaches. The ability to translate transcriptomic data between platforms has broad implications, including enhanced meta-analyses, improved toxicological modeling, and better integration of historical datasets with contemporary research. TransPlatformer seeks to contribute to this effort by evaluating translation methodologies and proposing novel strategies to improve cross-platform gene expression harmonization. In this repository there are code examples for TransPlatformer implementation

Cong, Guojing↗

Comparing perceptions of a dimmable LED lighting system between a real space and a virtual reality display

Over the last several decades, designers have used digital screens to view images of real and simulated spaces and make critical design decisions. Screen technology has improved during this time, as technologies like OLED have replaced legacy displays (CRT, plasma, and LCD). These new screens provide a higher pixel resolution, luminous output and contrast ratio. Immersive head-mounted displays now allow designers to view immersive images, and recent developments in real-time rendering have encouraged the uptake of virtual reality (VR) head-mounted displays in mainstream practice and design education. This paper presents an experiment on lighting perception using a series of LED lighting conditions in a real space and a virtual representation of those conditions captured using a 360° high-dynamic-range camera and presented on an HTC Vive Pro HMD. Fifty-three participants were asked to rate each lighting condition by viewing it in a real space (n = 30) or via immersive HDR photographs displayed in a VR HMD (n = 23). The results show that ratings of visual comfort, pleasantness, evenness, contrast and glare are similar between the HTC Vive Pro HMD and our real space when evaluating well-lit scenes, but significant differences emerge in dim and highly contrasted scenes for a number of rating scales.

Rockcastle, S.↗

Evaluation of sky spectra and sky models in daylighting simulations

Sky models in daylight simulations represent the luminance variation across the sky-dome for different locations, dates, times and weather conditions, but skies are typically modelled as colourless. Recent studies explore techniques for incorporating the spectral content of daylighting in simulations. This paper provides an evaluation of the existing spectral sky models in lighting simulation software. The comparisons are made between the available mathematical sky models and naturally occurring skies that were recorded using high dynamic range photography and spectrophotometric measurements. The results show that recently developed sky models present progress compared to colourless sky models, but further research is needed to accurately simulate daylight spectra.

97 MATHEMATICS AND COMPUTING↗