Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) baseline concept

There will be several state of the art spectrometers in operation on the NASA Polar Orbiting Platform (NPOP-1) as part of the Earth Observing System (EOS). The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument is presently being constructed for flight on the EOS. It is an imaging spectrometer utilizing a grating type, reflecting Schmidt optical design that must provide a 1.1 kilometer spatial resolution at nadir from a spacecraft altitude of 705 kilometers with a 1500 kilometer cross-track swath and a +/- 50 degree forward and aft tilt capability. The instrument is required to cover the wavelength range from 400 to 880 nanometers in approximately 15 nanometer steps with less than 2.3 percent instrument induced polarization. The absolute radiometric accuracy must be at least 5 percent over the full dynamic range of the instrument.

Magner, Thomas J.↗

Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model

A new class of tissue-equivalent proportional counters has been flown on two space shuttle flights. These detectors and their associated electronics cover a lineal energy range from 0.4 to 1250 keV/microns with a multichannel analyzer resolution of 0.1 keV/microns from 0.4 to 20 keV/microns and 5 keV/microns from 20 to 1250 keV/microns. These detectors provide the most complete dynamic range and highest resolution of any technique currently in use. On one mission, one detector was mounted in the Shuttle payload bay and another older model in the mid-deck, thus providing information on the depth dependence of the lineal energy spectrum. A detailed comparison of the observed lineal energy and calculated LET spectra for galactic cosmic radiation shows that, although the radiation transport models provide a rather accurate description of the dose (+/- 15%) and equivalent dose (+/- 15%), the calculations significantly underestimate the frequency of events below about 100 keV/microns. This difference cannot be explained by the inclusion of the contribution of splash protons. The contribution of the secondary pions, kaons and electrons produced in the Shuttle shielding, if included in the radiation transport model, may explain these differences. There are also significant differences between the model predictions and observations above 140 keV/microns, particularly for 28.5 degrees inclination orbit.

NASA Discipline Radiation Health↗

Prototype partial one-third octave band spectrum analyzer for acoustic, vibration and other wideband data for flight applications

The design refinement of a compact frequency analyzer for measurement and analysis on board flight vehicles is discussed. The analyzer has been constructed in a partial one-third octave band configuration with six filters and detectors spaced by the square root of 10 from 316 Hz to 100,000 Hz and a broadband detector channel. The analyzer has been tested over a temperature range of 40 to 120 F at a pressure of one atmosphere, and at a temperature of 75 F at an absolute pressure of 0.000001 torr, and has demonstrated at least 60 db of dynamic range.

Source record↗

The Moderate Resolution Imaging Spectrometer-tilt (MODIS-T)

There will be several state-of-the-art spectrometers in operation on the NASA Polar Oribting Platform (NPOP-1) as part of the Earth Observing System. The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir-viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The MODIS-T instrument is required to cover the wavelength range of 400 to 880 nm in approximately 15 steps, have less than 2.3 percent instrument-induced polarization, be calibrated to an absolute radiometric accuracy of at least 5 percent over the full dynamic range of the instrument, have a 1.1 kilometer square instantaneous field of view at nadir, and be capable of + or - 50-deg along-track tilt.

Magner, Thomas J.↗

Airborne measurements of laser backscatter from the ocean surface

The data are taken with three different pulsed laser sources, one each in the ultraviolet (337.1 nm), visible (532.1 nm) and infrared (9.5 microns). The principal instrument is the airborne oceanographic lidar of the NASA Wallops Flight Facility. The data on mean laser backscatter and its variation with angle off nadir are found to be consistent with previous analytical work and some previous experimental work. The absolute calibration of this backscatter in terms of an effective Lambertian reflectance is less precise, but the data support values near nadir of approximately 0.20 for low wind speeds. It is noted that these values are 1 order of magnitude larger than the Fresnel reflectance for an air/water discontinuity in the refractive index. Whereas the normalized standard deviation (modulation factor) of backscatter is less well understood analytically, it is defined by these measurements to range from a few percent to over 50 percent at nadir and to increase off nadir as the tangent of theta or faster. The data are uncertain beyond 15 deg off nadir owing to a dynamic range limitation.

Bufton, J. L.↗

Automatic Range Changer For SWR Meter

Commercial unit modified for antenna-pattern measurements. Addition of automatic range-changing circuit converts Hewlett-Packard 415E standing-wave-ratio (SWR) meter into radio-frequency detector suitable for computer-controlled measurements of radiation patterns of antennas. Modification gives SWR meter effective dynamic range of at least 40 dB. Includes two digital lines communicating one of four range settings to controlling computer and one digital line to inhibit transfer of data when range being changed. Ideal instrument for use in applications involving computer-controlled monitoring of power when large changes in signal level expected.

Dengler, Robert J.↗

Programmable random interval generator

Random pulse generator can supply constant-amplitude randomly distributed pulses with average rate ranging from a few counts per second to more than one million counts per second. Generator requires no high-voltage power supply or any special thermal cooling apparatus. Device is uniquely versatile and provides wide dynamic range of operation.

Lindsey, R. S., Jr.↗

Schottky Heterodyne Receivers With Full Waveguide Bandwidth

Compact THz receivers with broad bandwidth and low noise have been developed for the frequency range from 100 GHz to 1 THz. These receivers meet the requirements for high-resolution spectroscopic studies of planetary atmospheres (including the Earth s) from spacecraft, as well as airborne and balloon platforms. The ongoing research is significant not only for the development of Schottky mixers, but also for the creation of a receiver system, including the LO chain. The new receivers meet the goals of high sensitivity, compact size, low total power requirement, and operation across complete waveguide bands. The exceptional performance makes these receivers ideal for the broader range of scientific and commercial applications. These include the extension of sophisticated test and measurement equipment to 1 THz and the development of low-cost imaging systems for security applications and industrial process monitoring. As a particular example, a WR-1.9SHM (400-600 GHz) has been developed (see Figure 1), with state-of-the-art noise temperature ranging from 1,000-1,800 K (DSB) over the full waveguide band. Also, a Vector Network Analyzer extender has been developed (see Figure 2) for the WR1.5 waveguide band (500 750 GHz) with 100-dB dynamic range.

Hesler, Jeffrey↗

SHAPES - Spatial, High-Accuracy, Position-Encoding Sensor for multi-point, 3-D position measurement of large flexible structures

An electro-optical position sensor for precise simultaneous measurement of the 3-D positions of multiple points on large space structures is described. The sensor data rate is sufficient for most control purposes. Range is determined by time-of-flight correlation of short laser pulses returned from retroreflector targets using a streak tube/CCD detector. Angular position is determined from target image locations on a second CCD. Experimental verification of dynamic ranging to multiple targets is discussed.

Nerheim, N. M↗

A Satellite Borne Cadmium Sulfide Total Corpuscular Energy Detector

The properties of single crystals of cadmium sulfide as radiation detectors are described. It has been found possible to select crystals such that: (a) The ratio of increase of conductivity under irradiation to the rate of absorption of energy in the crystal is substantially independent of particle energy (over the examined ranges of 500 ev to 80 kev for electrons and 5 kev to 180 kev for protons) and of the magnitude of energy flux (over the range from.005 to 10 ergs/cm(sup 2 -sec); and (b) The above ration is substantially the same for protons, electrons, alpha particles, x-rays, and gamma-rays. For a driving voltage of 100 volts, typical crystal yield currents of 10(sup -7) to 10(sup- 6) amperes for each erg/cm(sup 2-sec) of energy absorbed by the crystal. The threshold of such crystal detectors (resulting from dark currents of the order of 10(sup 10 amp) is typically 10(sup -3) ergs/cm(sup 2- sec). For the selected crystals a response-temperature coefficient of -0.25% per degree centigrade is found for the temperature range -50 deg C to + 50 deg C. A description is given of a complete CdS total corpuscular energy detector for the study of geomagnetically trapped radiation by means of a satellite. The detector described has a dynamic range great than 10(sup 4), a solid angle of 10(exp -3) steradian, and a detection threshold of approximately 1 erg/cm(sup 2-sec-sterad). A similar detector employing a small magnet for the selective exclusion of electrons is also described. Noteworthy practical features of these detectors for satellite and space probe experiments are: (a) Use of bare crystals, without covering foils, in order to detect charged particles having energies as low as hundreds of electron volts. (b) Simplicity of electronic auxiliaries. (c) Compactness, lightweight and nechanical ruggedness. (d) Low electrical power requirements; and (e) Conversion of conduction current to the rate of a twostate relaxation oscillator in order to facilitate telemetric transmission of data. A pair of such detectors was flown as part of the s-46 satellite payload on March 23, 1960, but due to vehicular failure an orbit was not achieved and the operation of the CdS detectors was observed for only, six minutes of flight.

Freeman, John W.↗

Numerical simulation of diffusion-controlled droplet growth Dynamical correlation effects

Diffusion-controlled coarsening (Ostwald ripening) of precipitated solutions is studied by numerical simulation. An algorithm is devised which exploits the screening of solute concentration fields, thereby removing the restriction to small systems of previous work. Simulation of the coarsening of 5000 droplets at 10-percent volume fraction reveals long-ranged dynamical correlations which broaden the droplet size-distribution function and increase the coarsening-rate coefficient.

Beenakker, C. W. J.↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

First Assessments of ICESat-2 Performance Using Aircraft Data

The Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) Is a next-generation laser altimeter designed to continue key observations of ice sheet elevation change, sea ice freeboard, vegetation canopy height, earth surface elevation, and sea surface height. Scheduled for launch in early 2016, ICESat-2 will use a high repetition rate (approximately 10 kHz), small footprint (10m diameter) laser, and a single-photon-sensitive detection strategy (photon counting) to measure precise ranges to the earth's surface. Operating in the green (approximately 532nm), the six beams of ICESat-2 will provide improved spatial coverage compared with ICESat while the differences in transmit energy among the beams provide a large dynamic range. In order to evaluate models of predicted ICESat-2 performance, and provide ICESat-2-like data for algorithm development an airborne ICESat-2 simulator was developed and first flown in 2010, this simulator, the Multiple Altimeter Beam Experimental Lidar (MABEL) has now had three deployments in the western US, and will be deployed to the polar regions in spring of 2012. MABEL uses a similar measurement strategy to what will be used on ICESat-2. MABEL collects more spatially-dense data than ICESat-2 (approximately 2-cm along track) with a smaller 2m diameter footprint in 16 green channels and an additional 8 channels in the infrared. The comparison between frequencies allows for analysis of possible penetration of green energy into water or snow. We present MABEL data collected over deserts, forests, ocean water, lakes. snow covered mountains, and saft flats, provide examples of how these data are being used to develop algorithms that derive geophysical products from ICESat 2 and assess expected performances.

Neumann, Tom↗

Relating Standardized Visual Perception Measures to Simulator Visual System Performance

Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

Kaiser, Mary K.↗

A Fiber-Optic Aircraft Lightning Current Measurement Sensor

A fiber-optic current sensor based on the Faraday Effect is developed for aircraft installations. It can measure total lightning current amplitudes and waveforms, including continuing current. Additional benefits include being small, lightweight, non-conducting, safe from electromagnetic interference, and free of hysteresis and saturation. The Faraday Effect causes light polarization to rotate in presence of magnetic field in the direction of light propagation. Measuring the total induced light polarization change yields the total current enclosed. The system operates at 1310nm laser wavelength and can measure approximately 300 A - 300 kA, a 60 dB range. A reflective polarimetric scheme is used, where the light polarization change is measured after a round-trip propagation through the fiber. A two-detector setup measures the two orthogonal polarizations for noise subtraction and improved dynamic range. The current response curve is non-linear and requires a simple spline-fit correction. Effects of high current were achieved in laboratory using combinations of multiple fiber and wire loops. Good result comparisons against reference sensors were achieved up to 300 kA. Accurate measurements on a simulated aircraft fuselage and an internal structure illustrate capabilities that maybe difficult with traditional sensors. Also tested at a commercial lightning test facility from 20 kA to 200 kA, accuracy within 3-10% was achieved even with non-optimum setups.

Nguyen, Truong X.↗

Systematic Errors in Simulated L-Band Brightness Temperature in the SMAP Level-4 Soil Moisture Analysis

The NASA Soil Moisture Active Passive (SMAP) mission has been providing L-band (1.4 GHz) brightness temperature (Tb) observations since April 2015. By assimilating the Tb observations into the NASA Catchment land surface model using a spatially distributed ensemble Kalman filter (EnKF), the SMAP Level-4 Soil Moisture (L4_SM) product provides global, 3-hourly, 9-km resolution estimates of surface (0-5 cm) and root-zone (0-100 cm) soil moisture with ~2.5-day latency for use in research and applications. The EnKF-based L4_SM analysis assumes unbiased forecast errors. Consequently, the seasonally varying bias between the model forecast Tb and the observed values is removed prior to the assimilation of the SMAP Tb observations. The L4_SM system is thus designed to only correct errors in synoptic-scale and interannual variations from the long-term mean seasonal cycle while maintaining the model’s (possibly wrong) climatology. In this paper, we examine the Tb observation-minus-forecast (O-F) residuals from the L4_SM Version 7 product (computed after rescaling the Tb observations to the mean seasonal cycle of the simulated Tb). The long-term average of the Tb O-F residuals has a global mean of only 0.13 K and locally small values, ranging from -1 to 3 K. The model forecast Tb, however, still exhibits undesirable systematic errors relative to the (rescaled) Tb observations. At some locations, the time-average Tb O-F values strongly depend on surface soil moisture (SM). At the Yanco SMAP core validation site, for example, the Tb O-F residuals typically range from 5 to 15 K under dry soil moisture conditions (SM < 0.15 m3 m-3) yet are predominantly negative under wet soil moisture conditions (SM > 0.25 m3 m-3), with values ranging from 0 to -40 K. This results in soil moisture analysis increments that persistently make the soil drier under dry SM conditions and persistently make the soil wetter under wet SM conditions, suggesting an error in the dynamic range of the simulated Tb, soil moisture or soil temperature. In this paper, we describe the higher-order systematic Tb forecast errors in more detail, examine their impact on the L4_SM product quality, and explore potential avenues to improve the L4_SM algorithm.

Rolf Reichle↗

Examination of L-Band Brightness Temperature Forecasts in the SMAP Level-4 Soil Moisture Analysis

The NASA Soil Moisture Active Passive (SMAP) mission [4] has been providing L-band (1.4 GHz) passive microwave brightness temperature (Tb) observations since April 2015. By assimilating the Tb observations into the NASA Catchment land surface model [5] using a spatially distributed ensemble Kalman filter, the NASA Global Modeling and Assimilation Office generates the SMAP Level-4 Soil Moisture (L4_SM) product, which provides global, 3-hourly, 9-km resolution estimates of surface (0-5 cm) and root-zone (0-100 cm) soil moisture with ~2.5-day latency for use in research and applications [6]. The L4_SM product also includes estimates of soil temperature, land surface fluxes, and assimilation diagnostics such as the model forecast and observed Tb values [7]. The output from the L4_SM system is routinely monitored by the L4_SM team. Such monitoring provides valuable information; instances of unusually large Tb observation-minus-forecast (O-F) residuals can indicate events during which soil moisture conditions are poorly described in the land modeling system [7,8]. For example, repeated occurrences of very large Tb O-F values in central Australia were traced back to deficiencies in the gauge-based precipitation product used in the land modeling system through L4_SM Version 5; this discovery prompted the use, beginning in Version 6, of satellite- and gauge-based precipitation observations outside of North America [9]. Recently, a statistical analysis of the Tb O-F residuals revealed systematic errors in the “tau-omega” L-band radiative transfer model that converts the land-model simulated soil moisture and temperature into the forecast Tb prior to the L4_SM analysis. The L4_SM analysis is built on the ensemble Kalman filter and assumes unbiased forecast errors. The presence of systematic Tb forecast errors could thus adversely impact the quality of the analyzed soil moisture. In this paper, we examine the Tb O-F residuals of the latest Version 7 L4_SM data (Science Version ID Vv7030 and Vv7032) [10,11,12]. In the L4_SM Version 7 algorithm, key parameters of the L-band radiative transfer model, including soil roughness, scattering albedo, and a (seasonally varying) climatology of vegetation opacity, are obtained from the SMAP Level-2 Radiometer retrieval product (Version 5) [1]. Additionally, we also use ground measurements of surface soil moisture and soil temperature from the SMAP core validation sites as in situ reference of soil conditions [2,3]. As part of the L4_SM system calibration, the seasonally-varying bias between the model forecast Tb and the observed values is removed prior to the assimilation of the SMAP Tb observations [7]. That is, the L4_SM system is designed to only correct errors in synoptic-scale and interannual variations from the long-term mean seasonal cycle while maintaining the model’s (potentially erroneous) climatology. The Tb O-F residuals examined here are thus computed using SMAP Tb observations after they are rescaled to the mean seasonal cycle of Tb from the modeling system without SMAP data assimilation. Consequently, the long-term average of the Tb O-F residuals has a global mean of only 0.13 K and locally small values, ranging from -1 to 3 K. Despite the small time-average values of the Tb O-F residuals, the model forecast Tb was nevertheless found to exhibit undesirable systematic errors. At some locations, the time-average Tb O-F values strongly depend on surface soil moisture (SM). At the Yanco SMAP core validation site, for example, the Tb O-F residuals typically range from 5 to 15 K under dry soil moisture conditions (SM < 0.15 m3 m-3) yet are predominantly negative under wet soil moisture conditions (SM > 0.25 m3 m-3), with values ranging from 0 to -40 K. This results in soil moisture analysis increments that persistently make the soil drier under dry SM conditions and persistently make the soil wetter under wet SM conditions, suggesting an error in the dynamic range of the simulated Tb, soil moisture or soil temperature. In this paper, we describe the higher-order systematic Tb forecast errors in more detail, examine their impact on the L4_SM product quality, and explore potential avenues to further improve the L4_SM algorithm.

Rolf Reichle↗

Statistical performance of the intensified charged coupled device

The first analysis of the statistical performance of the intensified charge coupled device (CCD) is presented. The Poisson statistics of the arriving photons, the exponential pulse height distribution of the microchannel plate in the image intensifier, and the effects of discrete digitization of the charge in reading the CCD are included. A range of intensifier gains from the high levels that permit pulse counting to the low levels that can be used with the accumulation of charge on the CCD is considered. As a tool for this analysis, an analytical model of the performance of the detector system that is generally useful for predicting many aspects of system performance under a wide range of conditions is developed. The statistical penalty for operating the intensified CCD in the charge accumulation mode is not severe, and in some applications it may be desirable to accept this penalty to gain the advantages of increased dynamic range through charge accumulation. This investigation has revealed no pathological aspects of the operation of the detector system.

Sandel, B. R.↗