Energy Characterization of the UMD Electron Accelerator

Multiple different groups at Los Alamos National Laboratory have a cited interest in understanding the effects of ionizing radiation in materials. Of especial interest to the ISR division is understanding the effects in materials that are used in the space environment, where radiation is omnipresent and impossible to fully shield from. Development is under way to simulate the effects of radiation damage in detectors and electronics, primarily with particle transport codes such as Geant4 and RAMPART, a code that provides a user friendly interface to Geant4. However, these simulations need benchmarking to experimental tests, some of which have been performed at a variety of small electron accelerator facilities. One of these facilities is the Linear Electron Accelerator at the University of Maryland Radiation Facilities. This facility can provide electron beams on the order of 100 mA delivered in tight macropulse bunches, which allows for experiments where the behavior of electronics is monitored as a function of pulse number. While the beam rates per macropulse of this accelerator is monitored during an experiment via a current pick-off connected to a large graphite beamstop, the energy distribution of this electron beam is not measured during the experiment and has not been well characterized. The energy distribution of the beam is pertinent for these types of experiments, since dose is directly related to energy deposited in a medium. Further, these experiments are performed in open air and sample placement in the room can dictate what dose rate they receive per macropulse. We have created simulated dosemaps for the UMD vault room, but these simulations assume a given energy of the beam, both for calculating the dose and to simulate how much the beam diverges in the air. There have been two attempts now to characterize this accelerator beam energy with a plate type spectrometer, including the most recent experiment earlier this year to quantify the beam energy distribution. These results will also be compared to a dosimetry experiment performed by collaborators at the UMD facility, the details of which are described in Reference. Understanding the electron beam energy is important for future experiments, because the energy directly impacts the dose and radiation damage given to a sample and is important for properly simulating the electron beam when comparing simulation to experiment.

43 PARTICLE ACCELERATORS↗

Recommendations for harmonized reporting of radiation Dosimetry by adoption of Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER)

Here, in radiobiology, radiation physics, and related areas, there is growing interest in transitioning from cesium-based irradiators to X-ray technologies. Therefore, it makes it imperative for reproducibility purposes, for researchers to provide specifications regarding device parameters, machine calibration details, and experimental setup when innovative X-ray technology is being employed. Several groups have already identified a glaring lack in completeness of critical information on experimental setups, equipment, and physical parameters in published radiation biology studies. The Alternative Technologies Meta Study Report by Brookhaven National Laboratory (BNL) examined 456 manuscripts published between 2017-2021. Only 64 of the reviewed studies (14.0%) consistently reported methods that could allow for replication of their studies. However, 85% provided information on the manufacturer, the irradiator model and the absorbed radiation dose. Approximately 66% provided information on the energy spectra and the dose rate, but only one third disclosed the filter used. Less than 15% of the reviewed studies reported information on calibration and field geometry, specifically field size and distance from source, which are critical parameters in determining the absorbed radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-induced segregation in dilute Fe–Cr: A rate-theory framework for the Cr enrichment–depletion transition at the grain boundary

Radiation-induced segregation (RIS) poses a significant challenge for ferritic Fe–Cr alloys under irradiation, as it can compromise mechanical integrity and increase susceptibility to intergranular corrosion. Yet, the mechanisms governing Cr segregation remain incompletely understood. Here, in this study, we present a physics-based rate-theory model parameterized using self-consistent mean field theory-based Onsager transport coefficients to investigate RIS at the grain boundary in dilute Fe-(0.1 at. %) Cr. Under equal production rates of vacancies and self-interstitial atoms (SIA), and their equal absorption rates by bulk dislocations, the model simulates the experimentally observed transition from Cr enrichment at low temperatures to depletion at higher temperatures. Under these unbiased conditions, systematic investigation reveals that while temperature-dependent transport properties dictate the segregation direction, dose rate, grain size, and dislocation density only influence the magnitude and spatial extent of Cr segregation. However, under more realistic conditions of preferential vacancy production within damage cascade and/or preferential SIA absorption by bulk dislocations, the enrichment-to-depletion transition shifts to lower temperatures. Our findings demonstrate that RIS predictions based solely on transport coefficients are valid only under symmetric point defect flux conditions, and that biases in defect production and absorption must be considered for accurate predictions. This work provides a mechanistic framework for understanding RIS in ferritic alloys and informs alloy design for advanced nuclear systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Production Through Simulation: Using Simulation Technologies to Create and Evaluate Nuclear Fuel Fabrication Facility Designs

This project explores how physics-based and discrete-event simulation technologies can be jointly employed to model a suite of nuclear fuel fabrication facility designs with variable radiological environments, optimize their design to lower operational costs subject to a set of design constraints, and evaluate their performance. Initially, three variants of U-20Pu-10Zr metallic nuclear fuel in three specific geometric configurations are modeled and studied across more than 50 physics simulations in nuclear physics software packages SCALE and Monte Carlo N-Particle Transport (MCNP6.2). From these tests, values for effective dose rate and criticality are recorded for each of the nine alloy-geometry configurations. These values are then incorporated into discrete-event models of fuel fabrication in the simulation program ExtendSim Pro 10 as process attributes. This allows one to track the dose to facility personnel as fuel is fabricated, dually enabling us to evaluate the safety of a given facility design in terms of absorbed dose per worker per year and to craft operational guidelines that adhere to federal and local safety regulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride

A series of nondestructive assay measurements were performed before, during, and after localized heating of an industrial standard 12B cylinder of uranium hexafluoride to replicate dose variations previously observed on commercial 30B cylinders. While cylinders represent a closed system, enrichment measurements may be impacted by altered uranium and daughter product distributions due to sublimation. A series of measurements were performed to examine localized heating impacts on dose rates, ratios of uranium and daughter product distributions, and measured 235 U enrichment as calculated by two different approaches. The less complex enrichment meter approaches were found to be more robust and less prone to deviation than isotope ratio approaches such as FRAM, but the impact can be minimized by using observable dose changes to avoid impacted areas.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extension of OpenMC for Fixed Source Transmutation Calculations

This report documents work performed under a Strategic Partnership Project between Argonne National Laboratory (ANL) and the United Kingdom Atomic Energy Authority (UKAEA). The overall goal of this project is to extend OpenMC [1], a community-developed Monte Carlo particle transport code, to be able to perform fixed-source transmutation calculations. In fission and fusion reactors, the high flux of energetic neutrons causes materials within the reactor to “transmute,” or undergo a nuclear reaction that results in the addition/removal of neutrons and protons from the nucleus of an atom. If subjected to these reactions for long enough, the overall composition and physical properties of the material itself begin to change as a result of transmutation. Such a feature is vital for predicting the decrease in tritium production rate within a breeder blanket during the lifetime of a fusion reactor. OpenMC is capable of simulating neutron transport in fission/fusion systems, thereby allowing it to estimate the flux that causes transmutation. It is also capable of solving the transmutation equations, which determine how the composition of a material changes over time due to neutron irradiation and radioactive decay. However, solving the transmutation equations was previously only possible when the source of neutrons came from a fission system. In a fusion system, the source of neutrons is typically determined by a separate code and then given as an input to the particle transport simulation. This is known as a fixed source calculation. Through this project, we have extended OpenMC to solve the transmutation equations for a fixed source calculation. Evaluating the change in material compositions due to transmutation and its effect on physical properties is of key importance to a range of engineering analyses for fission and fusion systems. For example, in a fusion reactor, estimating the dose rate at different physical locations resulting from irradiated materials in the reactor allows designers to ensure that workers are not exposed to doses beyond applicable regulations. In order to properly dispose of irradiated materials, designers also need to estimate the radiotoxicity, which again relies on knowledge of the material composition at some future time. The specific tasks for this project that were agreed to between ANL and UKAEA were as follows: 1. Make changes and additions in the openmc.deplete and related modules in OpenMC to support transmutation calculations following a fixed source transport simulation. 2. Make necessary changes to OpenMC to model transmutation due to an arbitrary set of reactions needed for fusion applications. Use this new capability to generate a depletion chain file based on the TENDL nuclear data library. 3. Improve the openmc.deplete module in OpenMC to keep track of gases produced as a by-product of nuclear reactions during transmutation calculations. 4. Validate the new capabilities by carrying out fixed-source transmutation calculations on a suitable benchmark problem using OpenMC and a comparable Monte Carlo neutron transport code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes

Radiotherapy with very high energy electrons has been investigated for a couple of decades as an effective approach to improve dose distribution compared to conventional photon-based radiotherapy, with the recent intriguing potential of high dose-rate irradiation. Its practical application to treatment has been hindered by the lack of hospital-scale accelerators. High-gradient laser-plasma accelerators (LPA) have been proposed as a possible platform, but no experiments so far have explored the feasibility of a clinical use of this concept. We show the results of an experimental study aimed at assessing dose deposition for deep seated tumours using advanced irradiation schemes with an existing LPA source. Measurements show control of localized dose deposition and modulation, suitable to target a volume at depths in the range from 5 to 10 cm with mm resolution. The dose delivered to the target was up to 1.6 Gy, delivered with few hundreds of shots, limited by secondary components of the LPA accelerator. Measurements suggest that therapeutic doses within localized volumes can already be obtained with existing LPA technology, calling for dedicated pre-clinical studies.

59 BASIC BIOLOGICAL SCIENCES↗

Van de Graaff Irradiation Studies of Oxygen Sensor and Hydrated Zirconia Sorbent

Commercial-scale production of Mo-99 demands a facility-wide assessment of radiation-induced degradation across process equipment, instrumentation, and purification media. Key factors— total ionizing dose, dose rate, radiolysis-driven chemistry, thermal loads, activation, and any neutron-related effects—should inform material selection, shielding, and component layout. Purification materials (sorbents, resins, filters, seals, housing) require particular attention to ensure that irradiation does not alter selectivity or capacity, generate fines, or introduce leachables that could compromise Mo-99 purity or downstream Tc-99m generator performance. Dose mapping, accelerated irradiation testing, and studies of extractables/leachables together provide the basis for setting maintenance, calibration, and replacement intervals and for qualifying materials that retain mechanical integrity, chemical compatibility, and radiopurity over their service life.

36 MATERIALS SCIENCE↗

Methods for Estimating Dose from Galactic Cosmic Rays and Jovian Radiation Belts on Reduced-Order Monte Carlo Geometries

This document outlines the methods and tools developed to estimate dose rates from galactic cosmic rays and the trapped radiation belts surrounding Jupiter using Monte Carlo particle transport software. Furthermore, the techniques described here are specific for translating high-resolution MAVRIC models to analogous but lower resolution Monte Carlo N-Particle Transport (MCNP) code models to estimate charged particle effects on models originally developed to study neutral particles only. This capability was initially developed to predict doses to various components of dynamic radioisotope power systems for spaceflight applications, but the tools and methods can be easily applied to other problem geometries and expanded to other space radiation environments.

79 ASTRONOMY AND ASTROPHYSICS↗

MX precipitate behavior in an irradiated advanced Fe-9Cr steel: Self-ion irradiation effects on phase stability

In an effort to optimize Fe-9Cr reduced activation ferritic/martensitic (RAFM) steels and to inform the design and operation of fusion reactors, this work represents the first in a series of cohesive studies dedicated to the evolution of MX-TiC precipitates under accelerated single and dual ion irradiations. This study investigates CNA9, a simplified Fe-9Cr RAFM steel featuring initial MX-TiC precipitate densities of (2.3±0.3)×10²¹ m⁻³. This material was subjected to single self-ion irradiation at damage levels ranging from 1 to 100 displacements per atom (dpa) over a temperature range of 300 to 600°C, with a nominal dose rate of 7×10⁻⁴ dpa/s. Irradiation-induced coarsening was observed, as evidenced by statistically significant increases in mean diameter sizes, at 15 dpa at both 500°C and 600°C, whereas no coarsening was noted at 300°C or 400°C. Further, complete dissolution of precipitates occurred at damage levels of 50 and 100 dpa across the two temperatures tested (300°C and 500°C) while no significant changes were observed at any doses below 15 dpa at 500°C. Experimentally parameterized recoil resolution modeling suggests that the observed radiation stability of MX-TiC precipitates is intricately linked to diffusional changes of solutes resulting from the co-evolution of microstructural features within the experiments. The findings align with current theoretical perspectives on radiation-induced precipitate stability in complex alloys.

36 MATERIALS SCIENCE↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiolysis of Thin Water Ice in Electron Microscopy

Little is known about the radiolysis of water ice, especially as compared to the radiolysis of liquid water. In this study, the radiolytic decomposition of thin water ice films is probed for an initial 80 keV electron beam using electron energy loss spectroscopy, EELS. Pre-peaks in the oxygen K-edge spectra give the relative intensities of most of the oxygen containing species produced by radiolytic water decomposition. Contrary to expectations from the extrapolation of liquid water radiolysis data to high dose rates where significant H 2 O 2 production is expected, the main molecular product observed in the oxygen K-edge EELS spectra of water ice is O 2 . Significant mass loss of water and decomposition of most of its radiolytic products are observed for higher exposures, and the O atom seems to have a major role in the subsequent chemistry. An inverse relationship between the formation of O 2 and of ·OH is observed. A new high-dose reaction scheme is proposed. Furthermore, the significance of our results with respect to the radiolysis of water ice and for electron microscopy studies is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the mechanism of radiation and thermal-induced degradation of the insulation cables in nuclear power plants-the presence of long-lived polyenyl C-centered radicals

Radiolytically and thermally produced long-lived polyenyl C-centered radicals in the nuclear power plants’ insulation cables are detected and measured after more than 45 months of aging since the irradiation and the thermal treatment. Electron Paramagnetic Resonance (EPR) results of the irradiated Cross-linked Polyethylene (XLPE) and Ethylene Propylene Rubber (EthProRu), used as primary insulation materials at Nuclear Power Plants (NPP), clearly demonstrate the presence of polyenyl radicals along with allyl and peroxyl radicals. The yields of these free radicals are dose-rate dependent. EPR results also show the presence of the long-lived polyenyl along with allyl and peroxyl free radicals in the thermally treated XLPE, and EthProRu. These free radicals can cause a major failure in the performance of these cables in NPPs. Besides, the results showed the enhancement in the oxidation reactions due to the migration of copper ions from the conductor to the bulk of the insulation. Further, this study also shows that the oxidation index (OI) and Elongation at Break (EAB) increases and decreases respectively at higher doses and temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Activation Analysis in Preparation for a Tungsten Irradiation Experiment at LANSCE

To organize the safe handling of activated material, knowing the residual dose rates is crucial. Here, in this work, we present the pre-experiment activation analysis for an experiment in which tungsten blocks are irradiated by 800-MeV protons. In this analysis, we use the Monte Carlo N-Particle (MCNP) code for radiation transport, Attila4MC for unstructured mesh generation, and Activation in Accelerator Radiation Environments (AARE), including CINDER2008, for activation analysis. If the tungsten blocks must be removed within a day after the experiment, then exposure to personnel entering the room must be reduced. One exposure-reduction strategy is to add carbon steel shielding around the tungsten blocks, efficiently reducing the dose from the activated tungsten. However, the shielding becomes activated itself during irradiation: 56Mn is the dominant contributor for short decay times. The actual schedule at the time of the experiment allowed sufficient cool-off time for the tungsten in the room so that additional shielding was not necessary. A less rigorous comparison of the calculated values with the post-experiment measurements showed reasonable agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data on Cu- and Ni-Si-Mn-rich solute clustering in a neutron irradiated austenitic stainless steel

The data presented in this article is supplementary to the research article “Phase instabilities in austenitic steels during particle bombardment at high and low dose rates” (Levine et al.). Needle-shaped samples were prepared with focused ion beam milling from a 304L stainless steel that was irradiated with fast neutrons (E 0.1 MeV) in the BOR-60 reactor at 318 °C to 47.5 dpa. Atom probe tomography (APT) experiments in voltage mode were then conducted on a Cameca LEAP 5000X HR. Atom position, range, and mass spectrum files after reconstruction with Cameca’s IVAS software are included. Cu- and Ni-Si-Mn-rich solute nanoclusters were identified and analyzed using the Open Source Characterization of APT Reconstructions (OSCAR) program. Python code for OSCAR, information on the program’s underlying algorithm, and sample output files are provided. A proximity histogram of a Ni-Si-Mn-rich cluster and a 1D density/solute concentration profile of a Cu-rich cluster are given to demonstrate OSCAR’s analytical functionalities. The provided APT dataset is valuable for benchmarking phase instabilities in neutron-irradiated austenitic stainless steels that occur at high doses. The OSCAR program can be reused to process other APT data sets where solute nanoclustering is of interest.

42 ENGINEERING↗