A Transactive Network Template for Decentralized Coordination of Electricity Provision and Value

Transactive energy systems facilitate and plan for an allocation of electricity based on distributed, value-based negotiations. They are currently extending the usage of market-based principles and transactions from wholesale electricity markets where they exist today downward into distribution systems. While many interesting transactive energy systems have been proposed, few fully decentralize price discovery and price-responsive control. Even fewer plan for extensibility that will be needed for the ultimate growth of transactive networks and for the inclusion of additional and new objectives and new flexible, responsive assets. This paper introduces a transactive network template from which an agent may be configured at its network node to negotiate for electricity with other neighboring network agents, manage a set of locally-owned supply and demand assets, and induce local power balance through price discovery. A set of base object classes defines the template and may be extended. Three important basic computational responsibilities are allocated among the base object classes—scheduling, balancing, and network coordination. These several basic classes and responsibilities may be used to represent the perspective of large and small devices and regions anywhere in the electric power grid because they are based on the self-similarity of these objects and responsibilities. Agents in a transactive network are not at all unique in these basic responsibilities. So far, these following dynamic values have been addressed by extension of the base classes: energy value, demand charges, transport losses, and impacts of distributed renewable resources. The template is designed to be further extended to address and monetize still other valuable objectives.

Transactive, Transactive network, Transactive netw↗

Knowledge-based commodity distribution planning

This paper presents an overview of a Decision Support System (DSS) that incorporates Knowledge-Based (KB) and commercial off the shelf (COTS) technology components. The Knowledge-Based Logistics Planning Shell (KBLPS) is a state-of-the-art DSS with an interactive map-oriented graphics user interface and powerful underlying planning algorithms. KBLPS was designed and implemented to support skilled Army logisticians to prepare and evaluate logistics plans rapidly, in order to support corps-level battle scenarios. KBLPS represents a substantial advance in graphical interactive planning tools, with the inclusion of intelligent planning algorithms that provide a powerful adjunct to the planning skills of commodity distribution planners.

Saks, Victor↗

SU-F-T-216: Evaluating Dosimetry Accuracy of a Treatment Planning System On Small Proton Fields

Purpose: This study is aiming to identify the smallest field size for which a treatment planning system (TPS) can accurately calculate the relative dose distribution. The finding would be used as a guideline to choose the smallest proton field for clinical treatment. Methods: Mevion S250™ double scattering proton delivery system and Eclipse™ TPS (Varian) with pencil beam convolution (PBC) dose algorithm were used in this study. Square sized fields of 1 cm, 2 cm, 3 cm, 4 cm, 5 cm, and 10 cm were planned on a cubical water phantom with iso-center placed at 10 cm depth. All beams used the same proton beam option: range 15 cm and modulation 10 cm. Dose in water was calculated without any compensator. Gafchromic™ EBT3 film and diode detectors were used to measure the central axis dose distribution and lateral dose profiles at 5 cm, 10 cm, and 14 cm depth. Results: The preliminary film measurement shows good agreement between Eclipse calculated lateral dose profiles for all tested field sizes. The differences on full width half maximum were ≤ 1 mm while the differences on the penumbras were between 1 mm and 2 mm between Eclipse and film. For the depth dose, Eclipse results matched well with film measurements for field sizes down to 2 cm{sup 2}. With smaller field size of 1 cm{sup 2}, Eclipse was able to predict the decreasing of SOBP due to the lack of lateral charged particle equilibrium in depth. However, it did not match the film measurement. Diode measurement results will be available at the time of presentation. Conclusion: The PBC dose algorithm in Eclipse can accurately calculate relative dose distribution in double scattered proton system for field size down to 2 cm{sup 2}.

60 APPLIED LIFE SCIENCES↗

Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques

Purpose: To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. Methods: The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch distance and a sensitive volume of about 4 mm{sup 3}. The detector has been characterized with {sup 60}Co radiation and MV x rays from different linear accelerators (with flattened and unflattened beam qualities). Sensitivity dependence on dose per pulse has been evaluated under MV x rays by changing both the source to detector distance and the beam quality. Bias voltage has been varied in order to evaluate the charge collection efficiency in the most critical conditions. Relative dose profiles have been measured for both flattened and unflattened distributions with different field sizes. The reference detectors were a commercial array of ionization chambers and an amorphous silicon flat panel in direct conversion configuration. Profiles of dose distribution have been measured also with intensity modulated radiation therapy (IMRT), stereotactic radiosurgery (SRS), and volumetric modulated arc therapy (VMAT) patient plans. Comparison has been done with a commercial diode array and with Gafchromic EBT3 films. Results: Repeatability and stability under continuous gamma irradiation are within 0.3%, in spite of low active volume and sensitivity (∼200 pC/Gy). Deviation from linearity is in the range [0.3%, −0.9%] for a dose of at least 20 cGy, while a worsening of linearity is observed below 10 cGy. Charge collection efficiency with 2.67 mGy/pulse is higher than 99%, leading to a ±0.9% sensitivity change in the range 0.09–2.67 mGy/pulse (covering all flattened and unflattened beam qualities). Tissue to phantom ratios show an agreement within 0.6% with the reference detector up to 34 cm depth. For field sizes in the range 2 × 2 to 15 × 15 cm{sup 2}, the output factors are in agreement with a thimble chamber within 2%, while with 25 × 25 cm{sup 2} field size, an underestimation of 4.0% was found. Agreement of field and penumbra width measurements with the flat panel is of the order of 1 mm down to 1 × 1 cm{sup 2} field size. Flatness and symmetry values measured with the 1D array and the reference detectors are comparable, and differences are always smaller than 1%. Angular dependence of the detector, when compared to measurements taken with a cylindrical chamber in the same phantom, is as large as 16%. This includes inhomogeneity and asymmetry of the design, which during plan verification are accounted for by the treatment planning system (TPS). The detector is capable to reproduce the dose distributions of IMRT and VMAT plans with a maximum deviation from TPS of 3.0% in the target region. In the case of VMAT and SRS plans, an average (maximum) deviation of the order of 1% (4%) from films has been measured. Conclusions: The investigated technology appears to be useful both for Linac QA and patient plan verification, especially in treatments with steep dose gradients and nonuniform dose rates such as VMAT and SRS. Major limitations of the present prototype are the linearity at low dose, which can be solved by optimizing the readout electronics, and the underestimation of output factors with large field sizes. The latter problem is presently not completely understood and will require further investigations.

60 APPLIED LIFE SCIENCES↗

Grid-Integrated Distributed Solar: Addressing Challenges for Operations and Planning, Greening the Grid

Greening the Grid provides technical assistance to energy system planners, regulators, and grid operators to overcome challenges associated with integrating variable renewable energy into the grid. This document introduces a brief overview of common technical impacts of PV on distribution systems and operations, as well as emerging strategies for successfully addressing some of the priority issues.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-F-T-194: Analyzing the Effect of Range Shifter Air Gap On TPS Dose Modeling Accuracy in Superficial PBS Proton Therapy

Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dose optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.

60 APPLIED LIFE SCIENCES↗

Grid-Edge resource controller to enhance distribution grid resilience [SWR-19-70]

This Grid-Edge resource controller provides an unprecedented operational resilience enhancement solution for distribution grids to achieve the lowest system degradation and fast service restoration during extreme events. Specifically, it involves integrated planning and operation approaches that provide distribution grids with a self-evolving capability on dynamically altering system topology and adjusting the operations of edge-intelligent resources in response to dynamic weather disruptions.

Ding, Fei↗

Sci—Thur PM: Planning and Delivery — 06: Real-Time Interactive Treatment Planning

Purpose: To describe and evaluate a novel system for generalized Real-Time Interactive Planning (RTIP) applied to head and neck (H and N) VMAT. Methods: The clinician interactively manipulates dose distributions using DVHs, isodoses, or rate of dose fall-off, which may be subjected to user-defined constraints. Dose is calculated using a fast Achievable Dose Estimate (ADE) algorithm, which simulates the limits of what can be achieved during treatment. After each manipulation contributing fluence elements are modified and the dose distribution updates in effectively real-time. For H and N VMAT planning, structure sets for 11 patients were imported into RTIP. Each dose distribution was interactively modified to minimize OAR dose while constraining target DVHs. The resulting RTIP DVHs were transferred to the Eclipse™ VMAT optimizer, and conventional VMAT optimization was performed. Results: Dose calculation and update times for the ADE algorithm ranged from 2.4 to 22.6 milliseconds, thus facilitating effectively real-time manipulation of dose distributions. For each of the 11 H and N VMAT cases, the RTIP process took ∼2–10 minutes. All RTIP plans exhibited acceptable PTV coverage, mean dose, and max dose. 10 of 11 RTIP plans achieved substantially improved sparing of one or more OARs without compromising dose to targets or other OARs. Importantly, 10 of the 11 RTIP plans required only one or two post-RTIP optimizations. Conclusions: RTIP is a novel system for manipulating and updating achievable dose distributions in real-time. H and N VMAT plans generated using RTIP demonstrate improved OAR sparing and planning efficiency. Disclosures: One author has a commercial interest in the presented materials.

60 APPLIED LIFE SCIENCES↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated Smart Distribution RD&D Project Final Technical Report

Title XIII of the Energy Independence and Security Act of 2007 (EISA), tasked OE with accelerating the commercialization, deployment and integration of advanced digital systems that are needed to modernize the nation’s electricity delivery network for enhanced interoperability and cyber security. To support this mandated task, a goal of the SGR&D Program is to develop technology with the ability to dynamically optimize grid operations and resources and incorporate demand response and consumer participation. The majority of historical research and development in the domain of distribution management systems (DMS) had focused on classical, radial and passive networks with one-way power flow from transmission to distribution systems and thus to the end customer. With the focus on customers, a bottom-up approach required a completely new thinking in real-time operations, and automation, of smart distribution systems. Thus, the GE team embarked on a project with a plan of two distinct phases. Work during the first phase concentrated on research and development (R&D) for the first three years. The second phase, lasting approximately two years, accomplished the demonstration of the use cases developed during the first phase, with further sharing and dissemination of the research at industry events. The consolidated technical scope of the project can be summarized into the following six areas: Advanced distribution modeling capability to accurately simulate/model smart grid operations. Accurate representation of the distribution system in real- or near real-time (capture real-time topology). Interoperability with, and seamless communication between, other management systems and databases used by the utility Simulation of distribution systems based on real-time operational planning to analyze the benefits of smart grid assets. Integration of network, market, and renewable resource models for next generation DMS. Management and forecasting of DER (Distributed Generation, Storage, Demand Response).

14 SOLAR ENERGY↗

SU-E-T-764: Track Repeating Algorithm for Proton Therapy Applied to Intensity Modulated Proton Therapy for Head-And-Neck Patients

Purpose: To determine the suitability of fast Monte Carlo techniques for dose calculation in particle therapy based on track-repeating algorithm for Intensity Modulated Proton Therapy, IMPT. The application of this technique will make possible detailed retrospective studies of large cohort of patients, which may lead to a better determination of Relative Biological Effects from the analysis of patient data. Methods: A cohort of six head-and-neck patients treated at the University of Texas MD Anderson Cancer Center with IMPT were utilized. The dose distributions were calculated with the standard Treatment Plan System, TPS, MCNPX, GEANT4 and FDC, a fast track-repeating algorithm for proton therapy for the verification and the patient plans. FDC is based on a GEANT4 database of trajectories of protons in a water. The obtained dose distributions were compared to each other utilizing the g-index criteria for 3mm-3% and 2mm-2%, for the maximum spatial and dose differences. The γ-index was calculated for voxels with a dose at least 10% of the maximum delivered dose. Dose Volume Histograms are also calculated for the various dose distributions. Results: Good agreement between GEANT4 and FDC is found with less than 1% of the voxels with a γ-index larger than 1 for 2 mm-2%. The agreement between MCNPX with FDC is within the requirements of clinical standards, even though it is slightly worse than the comparison with GEANT4.The comparison with TPS yielded larger differences, what is also to be expected because pencil beam algorithm do not always performed well in highly inhomogeneous areas like head-and-neck. Conclusion: The good agreement between a track-repeating algorithm and a full Monte Carlo for a large cohort of patients and a challenging, site like head-and-neck, opens the path to systematic and detailed studies of large cohorts, which may yield better understanding of biological effects.

60 APPLIED LIFE SCIENCES↗

SURE (Science User Resource Expert): A science planning and scheduling assistant for a resource based environment

SURE (Science User Resource Expert) is one of three components that compose the SURPASS (Science User Resource Planning and Scheduling System). This system is a planning and scheduling tool which supports distributed planning and scheduling, based on resource allocation and optimization. Currently SURE is being used within the SURPASS by the UARS (Upper Atmospheric Research Satellite) SOLSTICE instrument to build a daily science plan and activity schedule and in a prototyping effort with NASA GSFC to demonstrate distributed planning and scheduling for the SOLSTICE II instrument on the EOS platform. For the SOLSTICE application the SURE utilizes a rule-based system. Development of a rule-based program using Ada CLIPS as opposed to using conventional programming, allows for capture of the science planning and scheduling heuristics in rules and provides flexibility in inserting or removing rules as the scientific objectives and mission constraints change. The SURE system's role as a component in the SURPASS, the purpose of the SURE planning and scheduling tool, the SURE knowledge base, and the software architecture of the SURE component are described.

Thalman, Nancy E.↗

Combining Simulation and Emulation Systems for Smart Grid Planning and Evaluation

Software-defined networking (SDN) enables efficient network management. As the technology matures, utilities are looking to integrate those benefits to their operations technology (OT) networks. To help the community to better understand and evaluate the effects of such integration, we develop DSSnet, a testing platform that combines a power distribution system simulator and an SDN-based network emulator for smart grid planning and evaluation. DSSnet relies on a container-based virtual time system to achieve efficient synchronization between the simulation and emulation systems. To enhance the system scalability and usability, we extend DSSnet to support a distributed controller environment. To enhance system fidelity, we extend the virtual time system to support kernel-based switches. In conclusion, we also evaluate the system performance of DSSnet and demonstrate the usability of DSSnet with a resilient demand response application case study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Science Campaign Scheduling for Sensor Webs

Future Earth observing missions will study different aspects and interacting pieces of the Earth's eco-system. Scientists are designing increasingly complex, interdisciplinary campaigns to exploit the diverse capabilities of multiple Earth sensing assets. In addition, spacecraft platforms are being configured into clusters, trains, or other distributed organizations in order to improve either the quality or the coverage of observations. These simultaneous advances in the design of science campaigns and in the missions that will provide the sensing resources to support them offer new challenges in the coordination of data and operations that are not addressed by current practice. For example, the scheduling of scientific observations for satellites in low Earth orbit is currently conducted independently by each mission operations center. An absence of an information infrastructure to enable the scheduling of coordinated observations involving multiple sensors makes it difficult to execute campaigns involving multiple assets. This paper proposes a software architecture and describes a prototype system called DESOPS (Distributed Earth Science Observation Planning and Scheduling) that will address this deficiency.

Edgington, Will↗

Comparing Resource Adequacy Metrics: Preprint

As the penetration of variable generation (wind and solar) increases around the world, there is an accompanying growing interest and importance in accurately assessing the contribution that these resources can make toward planning reserve. This contribution, also known as the capacity credit or capacity value of the resource, is best quantified by using a probabilistic measure of overall resource adequacy. In recognizing the variable nature of these renewable resources, there has been interest in exploring the use of reliability metrics other than loss of load expectation. In this paper, we undertake some comparisons using data from the Western Electricity Coordinating Council in the western United States.

14 SOLAR ENERGY↗

Comparing Resource Adequacy Metrics

As the penetration of variable generation (wind and solar) increases around the world, there is an accompanying growing interest and importance in accurately assessing the contribution that these resources can make toward planning reserve. This contribution, also known as the capacity credit or capacity value of the resource, is best quantified by using a probabilistic measure of overall resource adequacy. In recognizing the variable nature of these renewable resources, there has been interest in exploring the use of reliability metrics other than loss of load expectation. In this paper, we undertake some comparisons using data from the Western Electricity Coordinating Council in the western United States.

14 SOLAR ENERGY↗