Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Energy Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays

This is the final technical report for the Virginia Tech Center for Photonics Technology (VT-CPT) research project entitled “Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays”. In the the four-year effort, VT-CPT collaborated with the Departments of Mathmatics at VT and Sentek Instrument, LLC (Sentek) to develop a fiber-optic sensing system capable of real-time simultaneous distributed measurement of multiple subsurface, drilling, and production parameters. The ultra-sensitive fiber optic distributed acoustic sensing technology, picoDAS, developed by Sentek was integrated with a novel multi-material optical sensing fiber fabricated by CPT-VT to obtain distributed acoustic and magnetic field measurements with ultrahigh sensitivity and high spatial resolution. The sensing technology successfully developed and demonstrated under this research program is truly unique has application beyond subsurface imaging to include carbon storage and electrical grid monitoring, as well as healthcare and nuclear fusion. The project, sponsored by the Advanced Technology Program, began in 2019 and had the original goal of developing the next generation of harsh environment sensing systems. Exhaustive theoretical modeling was performed to optimize the multi-material optical fiber design. VT developed the processing techniques employed to successfully fabricate single mode fibers with metal cladding wires. Sensing fibers with nickel and Metglas cladding wires were fully characterized, inscribed with sensors, and fully integrated with the picoDAS system. Laboratory scale testing was performed to demonstrate performance upon exposure to lateral and transverse magnetic fields. Preliminary field trials were performed for prototype magnetic and acoustic sensing systems upon near surface deployment at VT. The distributed acoustic and magnetic field sensing system was advanced from a (Technology Readiness Level) TRL=2 to a TRL=5 via laboratory scale system validation in relevant environments. The truly one-of-its kind distributed magnetic and acoustic sensing system is expected to find immediate applications that require subsurface monitoring, to include carbon storage site monitoring, and has the potential to be a distributive technology in healthcare and electric grid markets. The technologies developed by Virginia Tech’s Center for Photonics Technology will support the mission of the National Energy Technology Laboratory (NETL) to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future by ensuring affordable, abundant, and reliable energy that drives a robust economy and national security. Technical accomplishments during the program are summarized briefly here and described in detail in the remainder of the report.

02 PETROLEUM↗

Uncertainty Analysis of Consequence Management Data Products

An interlaboratory effort has developed a probabilistic framework to characterize uncertainty in data products that are developed by the US Department of Energy Consequence Management Program in support of the Federal Radiological Monitoring and Assessment Center. The purpose of this paper is to provide an overview of the probability distributions of input variables and the statistical methods used to propagate and quantify the overall uncertainty of the derived response levels that are used as contours on data products due to the uncertainty in input parameters. Uncertainty analysis results are also presented for several study scenarios. This paper includes an example data product to illustrate the potential real-world implications of incorporating uncertainty analysis results into data products that inform protective action decisions. Data product contours that indicate areas where public protection actions may be warranted can be customized to an acceptable level of uncertainty. Finally, the investigators seek feedback from decision makers and the radiological emergency response community to determine how uncertainty information can be used to support the protective action decision-making process and how it can be presented on data products.

61 RADIATION PROTECTION AND DOSIMETRY↗

Primary System Test Facility Review

Idaho National Laboratory (INL) is designing a Dynamic Energy Transport and Integration Laboratory (DETAIL) to demonstrate the operation of an integrated energy system as part of supporting research and development needs for the DOE Office of Nuclear Energy Integrated Energy Systems (IES) Program. DETAIL will demonstrate real-time integration with the electrical grid, renewable energy inputs, thermal and electrical energy storage, and energy delivery to an end user. A Thermal Energy Distribution System (TEDS) is being constructed within the DETAIL facility to demonstrate the operation of integrated energy system heat transfer components, thermal energy storage, distribution systems, and instrumentation and control (I&C), which will allow the facility to emulate the distribution of thermal energy to the generation of electrical power, and/or producing non-electrical commodities (e.g., hydrogen). As is the case for other subsystems within DETAIL, TEDS is designed to operate either independently or as a part of an integrated system to demonstrate the operation of integrated components, develop and validate thermal energy transport models and control systems, and study thermal energy inertia and energy storage. In an effort to completely understand how TEDS will integrate with operational plants, data from tests previously run at existing integral system test facilities (IST) will be used to drive the TEDS heater. Alternatively, a real-time data connection would allow steam conditions at the IST to drive the TEDS heater at the same time as having TEDS conditions provide feedback to the IST in terms of steam demand and/or pressure. This integrated testing approach will assess the ability of TEDS to operate during all plant conditions. Three existing integral system test facilities have been reviewed to determine their suitability for demonstrating TEDS capabilities when integrated within the DETAIL. This report summarizes the capabilities of each IST facility and any challenges that must be overcome to meet the operational needs of TEDS and DETAIL.

25 ENERGY STORAGE↗

Integration of Clean Energy into Oil Field Operations

Integrating clean energy into oil and gas operations could reduce emissions and maximize higher-value use of produced hydrocarbons. In this published study, analysts from the Joint Institute for Strategic Energy Analysis (JISEA) and the National Renewable Energy Laboratory (NREL) evaluated clean power technologies for an oil field in the Delaware Basin using NREL’s Renewable Energy Integration and Optimization, or REopt, tool. The analysts evaluated different configurations of distributed energy resources based on the technologies available and the load they could satisfy, available land, and hypothetical carbon pricing. The analysis is part of a collaborative program with industry to understand site-specific energy consumption and prices in the oil and gas supply chain and determine under what conditions clean energy options are economically attractive. This work was sponsored by a consortium including ConocoPhillips, Baker Hughes, Extraction Oil & Gas, Kinder Morgan, and the Interstate Natural Gas Association of America Foundation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

State Energy Justice Roundtable Series: Participation in Decision Making

The National Association of Regulatory Utility Commissioners (NARUC), National Association of State Energy Officials (NASEO), and National Governors Association (NGA) hosted a State Energy Justice Roundtable (Roundtable) in April 2022. Participants included federal and state decision-makers, members of community-based organizations, and subject-matter experts. The Roundtable members explored current state efforts to articulate and incorporate energy justice concerns into energy-related decision-making. Participants established connections with one another to better understand the current landscape of existing resources, learn about emerging efforts, and identify ongoing support opportunities for advancing energy justice. This paper is one of five authored by the host organizations on topics that were the focus of the Roundtable. Each paper summarizes key themes, emerging efforts, and group takeaways that were discussed at the Roundtable and should assist state members in developing and meeting their own state goals around energy justice. The papers all include the same discussions of background, introduction, and reading list so they can be read separately. Each paper is written from the perspective of one association and includes options for its members to take actions that could support more equitable state energy policies and programs. The five papers cover: • Participation in decision making (NARUC) • Customer affordability and arrearages (NARUC) • Energy justice metrics (NARUC) • Equity in clean energy research and development (NASEO) • Equitable distributed energy resource (DER) access (NGA). The resources and recommendations listed in these papers are not meant to be exhaustive, as this field of study continues to evolve. Although this brief is focused on electricity, energy justice considerations extend to all energy needs and services, including the impact of energy extraction, processing, and distribution functions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

CP violation searches and distributed computing development with the Belle II Experiment at the University of Mississippi and Brookhaven National Laboratory (Final Report)

This report reflects the work performed at the University of Mississippi under the support of DOE EPSCoR grant DE‐SC0021274 during the period of September 2020 through August 2024, including a one-year, no-cost extension. A summary of the research outcomes is given, with reference to the project goals as stated in the proposal. This successful project supported the mission of the DOE High Energy Physics program by leveraging the complimentary expertise of researchers at the University of Mississippi and Brookhaven National Lab to search for CP violation in charmed baryon decays using data from the Belle II experiment and to provide vital support for Belle II distributed computing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing Storage Operation for a Probabilistic Locational Marginal Pricing Forecast: Preprint

This paper explores the applicability of using dynamic programing (DP) and approximate dynamic programming (ADP) based methods for optimal dispatch of utility scale energy storage systems (ESS). In this study, the effectiveness of these approaches have been tested using the IEEE 13 node test feeder with distributed photovoltaics (PVs) and a utility scale storage system. In this work, a co-simulation based approach has been used to setup the experiment to be able to implement detailed ESS and network models. The results obtained from DP/ADP runs have been compared with three other control strategies both myopic and intelligent. Simulations results show that DP/ADP algorithms are a good candidate for optimal EES dispatch in terms of both solution quality and execution time.

25 ENERGY STORAGE↗

Distributed Magnetic Measurements Using Fiber Optic Pulsed Polarimetry (Final Report)

Measurement of the magnetic fields surrounding magnetic fusion energy (MFE) devices, such as tokamaks, is critical for characterizing and monitoring the plasma inside these devices, and it is especially important for detecting plasma instabilities, which can lead to the plasma damaging the inside of these devices. This program successfully demonstrated a new type of magnetic field diagnostic that is capable for the first time of measuring simultaneously the spatial and temporal magnetic field distributions of MFE devices in real-time and with high resolution. This is a capability not feasible with existing magnetic field diagnostics and, moreover, the technique we developed provides other advantages, such as less susceptibility to noise, the ability to operate during both pulsed and steady-state plasma conditions, the ability to detect relatively weak poloidal fields, and potentially lower costs. This new capability of being able in real-time to detect anomalies in the magnetic field distribution corresponding to the onset of plasma instabilities offers the ability to automatically shut down the MFE device before the plasma can damage the machine. Hence, this machine protection capability can be vital for future fusion power stations. Our technique uses optical fibers where changes in the polarization of the laser light traveling through the fiber provide a direct measurement of the magnetic field at any point along the fiber. The small size of the fibers allows them to be easily installed either outside or inside the MFE vacuum vessel, and in any direction one wishes (e.g., poloidal or toroidal). We demonstrated the basic capabilities of our new diagnostic during a proof-of-principle experiment performed on the General Atomics DIII-D tokamak, and published the results in: W. D. Kimura, D. S. Dhillon, S. Munaretto, E. J. Strait, D. Du, S. Loranger, J.-S. Boisvert, and R. Kashyap, “Measurements of DIII-D poloidal field by fiber-optic pulsed polarimetry,” Rev. Sci, Inst. 89, 10J102 (2018).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Categorizing distributed wind energy installations in the United States to inform research and stakeholder priorities

Abstract Background Distributed wind energy adoption in the United States can contribute to the diverse portfolio of energy technologies needed to achieve ambitious decarbonization goals. However, with limited deployment to date, the current distributed wind market must be better understood; these efforts will support the range of stakeholders who will drive successful deployment. This article first distinguishes three categories of distributed wind from existing literature: (1) behind the meter, (2) intended for explicit local load, and (3) physically distributed. A novel methodology to classify individual wind installations into each of these categories is then presented and applied to two data sets of wind installations in the United States to categorize and illuminate distinct segments in the distributed wind market. Results Physically distributed installations, constituted by small to moderately sized projects serving local loads on distribution systems solely because of their proximity to them, account for the highest amount of capacity but the lowest number of installations out of the three categories. The inverse is true for behind-the-meter installations, which are used to serve on-site loads. Installations intended for explicit local load, which are interconnected on the utility side of the distribution system and intentionally built to provide energy to loads on the same distribution system, rank in the middle for both installed capacity and number of installations. Conclusions Distributed wind energy deployment in the United States is geographically widespread, but the extent to which a single category is developed in each state varies. Policies, wind resources, and broad energy technology trends contribute to these deployment patterns. By identifying the extent to which each category of installations exists, decision-makers are empowered with data necessary to tailor research and development programs and address stakeholder priorities through policy and other means, ultimately supporting future deployment.

17 WIND ENERGY↗

Jefferson Lab at 12 GeV: The Science Program

Jefferson Lab’s upgrade of its Continuous Electron Beam Accelerator Facility (CEBAF) has recently been completed. The project involved an upgrade of the accelerator to achieve a maximum beam energy of 12 GeV and the construction of a fourth end station, Experimental Hall D, as well as new detector equipment for two of the three existing halls (A, B, and C). A broad experimental program has been developed to map the nucleon’s intrinsic quark distributions in transverse space and in longitudinal momentum through measurements of deeply exclusive and semi-inclusive processes, and to probe color confinement by studying the spectrum of hadrons with active gluon degrees of freedom in the wave function. Other programs include the forward parton distribution function at large quark momentum fraction χ, the quark and gluon polarized distribution functions, measurements of electromagnetic form factors of the nucleon ground state and of nucleon resonance transitions at short distances, and the exploration of physics beyond the Standard Model in high-precision parity-violating processes and in the search for signals of dark matter. The higher beam energy is also suitable for exploration of quark hadronization properties using the nucleus as a laboratory. This review highlights major areas of hadron and nuclear science that will be the focus of the first 5 years of operation.

3D imaging↗

Precision Measurement of Net-Proton-Number Fluctuations in Au + Au Collisions at RHIC

We report precision measurements on cumulants (𝐶 𝑛 ) and factorial cumulants (𝜅 𝑛 ) of (net) proton number distributions up to fourth order in Au + Au collisions over center-of-mass energies $\sqrt{s_{NN}}$ = 7.7–27 GeV from phase II of the Beam Energy Scan program at RHIC. (Anti)protons are selected at midrapidity (|𝑦| < 0.5) within a transverse momentum range of 0.4 < 𝑝 𝑇 < 2.0 GeV/𝑐. Relative to various noncritical-point model calculations and peripheral collision 70%–80% data, the net proton 𝐶 4 /𝐶 2 measurement in 0%–5% collisions shows a minimum around 19.6 GeV for significance of deviation at ∼2–5⁢𝜎. A minimum in 𝐶 4 /𝐶 2 with respect to a noncritical baseline is expected to be a characteristic feature of the signature associated with a critical point in the QCD phase diagram. In addition, deviations from noncritical baselines around the same collision energy region are also seen in proton factorial cumulant ratios, especially in 𝜅 2 /𝜅 1 and 𝜅 3 /𝜅 1 . As a result, dynamical model calculations including a critical point are called for in order to understand these precision measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sodium Ion Expansion Power Block for Distributed CSP

The Sodium Ion Expansion Power Block for Distributed CSP was a three-plus-one-year effort under the Concentrating Solar Power: Advanced Projects Offering Low LCOE Opportunities (CSP: APOLLO) funding program within the U.S. Department of Energy Solar Energy Technologies Office. The primary objective of this project is to develop a dual-stage modular sodium thermal electrochemical converter (Na-TEC) heat engine power block, which can be potentially integrated with either a small-scale dish solar or large-scale heliostats and parabolic trough CSP. Na-TEC is a heat engine that generates electricity through the isothermal expansion of sodium ions. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (650 K –1050 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management. In light of this, we first designed and developed a thermo-electrochemical model, and thermodynamically demonstrated how the dual-stage device can improve the efficiency by up to 8% points over the best performing single-stage device. We also established an application regime map for the single- and dual-stage Na-TEC in terms of the power density and the total thermal parasitic loss. Moreover, a thermal design of an axisymmetric dual-stage Na-TEC is developed to guide the scale-up and fabrication of sub-components of prototype module. A reduced-order finite-element model is used in conjunction with a Na-TEC thermodynamic model that was developed to determine the total parasitic heat loss of this dual-stage design. A number of simplifications are applied in the reduced-order model to decrease the computational time while maintaining acceptable accuracy. According to this analysis, a maximum efficiency of 29% and a maximum power output of 125 W can be achieved. Ultimately, we were able to demonstrate thermal efficiency improvements of the Na-TEC heat engine from 19% up to 40.3%, in a dual-stage (non-optimized) prototype module that we designed, fabricated, and tested with high temperature stage at 923 K. Furthermore, a cost-performance analysis for this improved dual-stage design was carried out for distributed-CSP systems. A high-level techno-economic analysis (TEA) explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per We are feasible, which equate to LCOEs from 6.9 to 17.2 cents/kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

A computationally efficient algorithm for computing convex hull prices

Electricity markets worldwide allow participants to bid non-convex production offers. While non-convex offers can more accurately reflect a resource's capabilities, they create challenges for market clearing processes. For example, system operators may be required to execute side payments to participants whose costs are not covered through energy sales as determined via traditional locational marginal pricing schemes. Convex hull pricing minimizes this and other types of side payments while providing uniform (i.e., locationally and temporally consistent) prices. Computing convex hull prices involves solving either a large-scale linear program or the Lagrangian dual of the corresponding non-convex scheduling problem. Further, the former approach requires explicit descriptions of market participants' convex hulls. While linear programs for computing convex hull prices are large, their structure is naturally decomposable by generators. Here, in this work, we propose and empirically analyze a Benders decomposition approach to computing convex hull prices that leverages recent advances in convex hull formulations for thermal generating units. We demonstrate across a large set of test instances that our decomposition approach only requires modest computational effort, obtaining solutions at least an order of magnitude faster than the equivalent large-scale linear programming approach. Overall, we provide a computationally feasible method for computing convex hull prices for industrial scale market clearing problems, enabling the possibility of practical adoption of this advanced pricing mechanism.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗