SEARCH · Engineering Papers
Results for “Distributed Control”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Controlling Product Distribution of Polyethylene Hydrogenolysis Using Bimetallic RuM 3 (M = Fe, Co, Ni) Catalysts
Not Available
Conformations of polyolefins on platinum catalysts control product distribution in plastics recycling
The design of catalysts for the chemical recycling of plastic waste will benefit greatly from an intimate knowledge of the interfacial polymer–catalyst interactions that determine reactant and product distributions.
Blockchain-Assisted Resilient Control for Distributed Energy Resource Management Systems
Not provided.
Dissipativity-based Voltage Control in Distribution Grids.
Abstract not provided.
Distribution Voltage Control: Current Status and Future Trends
Explore the source record for details and available documents.
An Energy Storage Cost Comparison: Li-Ion Batteries vs Distributed Load Control
In 2017, San Diego Gas & Electric installed a 30 MW, 120 MWh lithium-ion battery storage facility-the world's largest at the time. But, recent work demonstrates that local control can enable flexible loads to provide equivalent battery-like services to the grid. Our cost comparison shows that it is much cheaper to acquire 30 MW, 120 MWh of capacity by retro-fitting 120,000 water heaters with control hardware and telecommunications. Surprisingly, it may even be cheaper to give away 120,000 'smart' water heaters!
Optimized Control of Distribution Switches to Balance a Low Cost Photovoltaic Microgrid.
Abstract not provided.
Optimal Energy Storage Schedules for Load Leveling and Ramp Rate Control in Distribution Systems
Continued integration of distributed energy resources (DERs) into the grid, such as solar PVs, at a large-scale, contributes into the famous Duck Curve. New DER management algorithms are therefore deemed necessary to alleviate rapid variations within net load profiles of distribution systems. Herein this paper proposes a process to determine the optimal energy storage schedules for leveling the distribution circuit feederhead net load. A series of sensitivity analyses shows how the proposed method can be used to determine the optimal energy storage schedules with different capacities, state of charge requirements, and net load ramp rate limitations.
The Strategic Value of Human Factors Engineering in Control Room Modernization
Control room modernization is one of the most challenging and complex upgrade projects that a nuclear power plant can undertake. It can have almost as big an impact on operations as, for example, turbine replacement. The challenges of migrating an analog control system to a distributed control system are already well known and a number of nuclear utilities have embarked upon various levels of effort to upgrade some of the systems in the control room. When planning for control room upgrades, plants have to deal with a multitude of engineering, operational, and regulatory impacts. This will inevitably include several human factors considerations, such as workstation ergonomics, viewing angles, lighting, seating, new interaction modalities, new communication requirements, and new concepts of operation. In helping nuclear power utilities to deal with these challenges, the United States Department of Energy researchers located at Idaho National Laboratory (INL) have developed research-based human factors design and evaluation methods to be used in the development of end-state concepts for modernized control rooms and to manage the various phases of the upgrade life cycle. The methodology includes interactive sessions with operators in INL’s Human System Simulation Laboratory, three-dimensional modeling to visualize control board changes and operator-system interaction, and development of human-system prototypes to evaluate various aspects of proposed modifications. This methodology has been applied at a number of U.S. nuclear power plants where modernization projects are underway, including Exelon’s Braidwood and Byron plants, and Arizona Public Service's Palo Verde plant. It was demonstrated that including this methodology in the plant’s engineering process helps to ensure an integrated and cohesive outcome that is consistent with human factors engineering principles and provide substantial improvement in operator performance.
Optimized Control of Distribution Switches to Balance a Low Cost Photovoltaic Microgrid.
Abstract not provided.
Dissipativity-based Voltage Control in Distribution Grids.
Abstract not provided.
Dissipativity-based Voltage Control in Distribution Grids.
Abstract not provided.
Towards High Performance Discrete-Event Simulations of Smart Electric Grids
Future electric grid technology is envisioned on the notion of a smart grid in which responsive end-user devices play an integral part of the transmission and distribution control systems. Detailed simulation is often the primary choice in analyzing small network designs, and the only choice in analyzing large-scale electric network designs. Here, we identify and articulate the high-performance computing needs underlying high-resolution discrete event simulation of smart electric grid operation large network scenarios such as the entire Eastern Interconnect. We focus on the simulator's most computationally intensive operation, namely, the dynamic numerical solution for the electric grid state, for both time-integration as well as event-detection. We explore solution approaches using general-purpose dense and sparse solvers, and propose a scalable solver specialized for the sparse structures of actual electric networks. Based on experiments with an implementation in the THYME simulator, we identify performance issues and possible solution approaches for smart grid experimentation in the large.
US Veteran Gets a Facelift
Idaho National Laboratory's Advanced Test Reactor (ATR) has received replacement instrumentation and control systems - the process distributed control system (DCS) and the console display system (CDS), which included a replacement annunciator subsystem. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. ATR, a pressurized, light water moderated 250 MW materials test reactor, became operational in 1965. In the early 1990s, after nearly thirty years of analogue/pneumatic controls, the laboratory upgraded ATR to digital-based instrumentation and control systems. By 2007, the equipment and technology used in these digital systems were reaching the end of their lifecycle. The systems component failure rates were on a rise, while vendor support and parts availability were declining. With current projections and plans for operating ATR into 2040, modernization of the reactor's infrastructure is necessary to maintain reliability and efficiency. As a result, the Idaho National Laboratory and the U.S. Department of Energy (DOE) invested more than $13 million in a four-year project to replace ATR's instrumentation and control systems.
DistFlow ODE: modeling, analyzing and controlling long distribution feeder
Abstract Not Provided
Optimal Control of Distributed Networked Energy Storage for Improved Small-Signal Stability.
Abstract not provided.