Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Mapping Conductance and Switching Behavior of Graphene Devices In Situ

Graphene is proposed for use in various nanodevice designs, many of which harness emergent quantum properties for device functionality. However, visualization, measurement, and manipulation become nontrivial at nanometer and atomic scales, representing a significant challenge for device fabrication, characterization, and optimization at length scales where quantum effects emerge. Herein, proof of principle results at the crossroads between 2D nanoelectronic devices, e-beam-induced modulation, and imaging with secondary electron e-beam induced currents (SEEBIC) is presented. A device platform compatible with scanning transmission electron microscopy investigations is introduced. Then how the SEEBIC imaging technique can be used to visualize conductance and connectivity in single layer graphene nanodevices, even while supported on a thicker substrate (conditions under which conventional imaging fails) is shown. Finally, it is shown that the SEEBIC imaging technique can detect subtle differences in charge transport through time in nonohmic graphene nanoconstrictions indicating the potential to reveal dynamic electronic processes.

36 MATERIALS SCIENCE↗

Understanding the Role of CdTe in Polycrystalline CdSe x Te 1– x /CdTe-Graded Bilayer Photovoltaic Devices

Grading of bandgap by alloying CdTe with selenium to form a CdSe x Te 1–x /CdTe-graded bilayer device has led to a device efficiency over 19%. A CdSe x Te 1–x absorber would increase the short-circuit current due to its lower bandgap but at the expense of open-circuit voltage. It has been demonstrated that adding a CdTe layer at the back of such a CdSe x Te 1–x film reduces the voltage deficit caused by the lower bandgap of absorber from selenium alloying while maintaining the higher short-circuit current. This leads to a photovoltaic device that draws advantage from both materials with an efficiency greater than either of them. In this report there is a detailed account using device data, ultraviolet photoelectron spectroscopy, electron microscopy, and first-principles density functional theory modeling is provided, which shows that CdTe acts as an electron reflector for CdSe x Te 1–x .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial control system device classification using network traffic features and neural network embeddings

Characterization of modern cyber–physical Industrial Control System (ICS) devices is critical to the evaluation of their security posture and an understanding of the underlying industrial processes with which they interact. In this work, we address two related ICS device identification tasks: (1) separating ICS from non-ICS devices and (2) identifying specific ICS device types. We propose two distinct methods (one based on the existing IP2Vec method, and a novel traffic-features-based method) for achieving the first task. For transferability of the first task between two datasets, the traffic-features-based method performs significantly better (75% overall accuracy) compared to IP2Vec (22.5% overall accuracy). We further propose a novel method called DNP2Vec to address the second task. DNP2Vec is evaluated on two different datasets and achieves perfect multi-class classification accuracy (100%) for both datasets.

42 ENGINEERING↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Even–Odd Layer-Dependent Exchange Bias Effect in MnBi 2 Te 4 Chern Insulator Devices

Magnetic topological materials with coexisting magnetism and nontrivial band structures exhibit many novel quantum phenomena, including the quantum anomalous Hall effect, the axion insulator state, and the Weyl semimetal phase. As a stoichiometric layered antiferromagnetic topological insulator, thin films of MnBi 2 Te 4 show fascinating even–odd layer-dependent physics. Here, in this work, we fabricate a series of thin-flake MnBi 2 Te 4 devices using stencil masks and observe the Chern insulator state at high magnetic fields. Upon magnetic field training, a large exchange bias effect is observed in odd but not in even septuple layer (SL) devices. Through theoretical calculations, we attribute the even–odd layer-dependent exchange bias effect to the contrasting surface and bulk magnetic properties of MnBi 2 Te 4 devices. Our findings reveal the microscopic magnetic configuration of MnBi 2 Te 4 thin flakes and highlight the challenges in replicating the zero magnetic field quantum anomalous Hall effect in odd SL MnBi 2 Te 4 devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Black Phosphorus for Mid-Infrared Optoelectronics: Photophysics, Scalable Processing, and Device Applications

High efficiency mid-infrared (λ = 3-8 μm) light emitters and photodetectors are pivotal for advancing next-generation optoelectronics. However, narrow-bandgap semiconductors face fundamental challenges such as pronounced nonradiative carrier recombination and thermally generated noise, which impede device performance. Recently, two-dimensional layered black phosphorus (BP) and its alloys have attracted substantial interest for mid-infrared device applications, demonstrating superior performance relative to conventional III-V and II-VI semiconductors with similar bandgaps. In this review, we discuss the optical properties of BP, contrasting these with those of covalent compounds. Owing to its inherently self-terminated surface structure and reduced nonradiative recombination, BP exhibits high performance in light emission and photodetection at room temperature. Furthermore, this review highlights recent advances in the large-area processing of BP thin films, paving the way for practical device applications and integration. Finally, we explore ongoing challenges and emerging opportunities in the utilization of BP for functional mid-infrared devices.

Higashitarumizu, Naoki↗

Predicting Device Parameters for Dye-Sensitized Solar Cells from Electronic Structure Calculations to Reproduce Experiment.

Given that improvements to the power-conversion efficiency (PCE) of dye-sensitized solar cells (DSSCs) have slowed in recent years, a means to accurately predict the device parameters yielded by trial dyes in silico, without having to synthesize them, would be extremely valuable to speed up the design process. Currently, the best-performing methods of calculating device parameters rely on a set of experimentally determined kinetic coefficients. In practice, it is very difficult to measure these kinetic parameters accurately, limiting the overall accuracy of such predictive methods. This work proposes a model to obtain key parameters such as J(SC), V-OC, and PCE using only the results from density functional theory (DFT) and time-dependent DFT calculations, noting that rates of electron-transfer steps are ultimately linked to the electronic structure of the dye center dot center dot center dot TiO2 working electrode. Six organic DSSC dyes from dissimilar chemical classes (L0, L1, L2, WS-2, WS-92, and C281) were chosen to demonstrate the power of this approach. Their a priori known experimentally determined device performance metrics served to validate our predictions. The greatest absolute error in our predicted PCE values was 0.36% relative to the experiment, while the greatest fractional error was 0.042. This indicates that the proposed model offers a dramatic improvement on previous predictive methods for DSSC device parameters, both in accuracy and in consistency. Moreover, such a predictive model has great potential to be applied to other photovoltaic applications, further enabling the design of novel, highly efficient photoactive materials.

density functional theory↗

Directly Linking Low-Angle Grain Boundary Misorientation to Device Functionality for GaAs Grown on Flexible Metal Substrates

A new growth method to make highly oriented GaAs thin films on flexible metal substrates has been developed, enabling roll-to-roll manufacturing of flexible semiconductor devices. The grains are oriented in the <001> direction with <1 degree misorientations between them, and they have a comparable mobility to single-crystalline GaAs at high doping concentrations. At the moment, the role of low-angle grain boundaries (LAGBs) on device performance is unknown. A series of electron backscatter diffraction (EBSD) and cathodoluminesence (CL) studies reveal that increased doping concentrations decrease the grain size and increase the LAGB misorientation. Cross-sectional scanning transmission electron microscopy (STEM) reveals the complex dislocation structures within LAGBs. Most importantly, a correlative EBSD/electron beam-induced current (EBIC) experiment reveals that LAGBs are carrier recombination centers and that the magnitude of recombination is dependent on the degree of misorientation. The presented results directly link increased LAGB misorientation to degraded device performance, and therefore, strategies to reduce LAGB misorientations and densities would improve highly oriented semiconductor devices.

36 MATERIALS SCIENCE↗

Low Threshold Voltages Electrochemically Drive Gold Migration in Halide Perovskite Devices

The constituent ions of halide perovskite materials are mobile in the solid state and known to participate in reduction/oxidation reactions. Yet few parameters related to electrochemical processes occurring within devices have been carefully determined. Here, we characterize such reactions in model MAPbI3 perovskite devices, and we quantify threshold voltages for key reactions. Gold is oxidized and mobilized under nitrogen, in the dark, at the MAPbI3/Au interface at 0.8 V. When this interface is buffered with the organic hole transport material (HTM), 2,2',7,7'-tetrakis(N,N-di-p-methoxyphenylamino)-9,9'-spirobifluorene, MAPbI3 begins to degrade at 1.2 V; degradation liberates ions that subsequently enable Au migration. Thresholds are insensitive to MAPbI3 thickness or choice of organic HTM or oxide cathode, which suggests that these reactions are driven electrochemically; the electric field across the device is less important. These results have profound implications for understanding in operando degradation pathways of optoelectronic perovskite devices that are varied in terms of interface structures, active material compositions, and ranges of external stressors.

42 ENGINEERING↗

Superhydrophobic Array Devices for the Enhanced Formation of 3D Cancer Models

During the metastatic cascade, cancer cells travel through the bloodstream as circulating tumor cells (CTCs) to a secondary site. Clustered CTCs have greater shear stress and treatment resistance, yet their biology remains poorly understood. We therefore engineered a tunable superhydrophobic array device (SHArD). The SHArD-C was applied to culture a clinically relevant model of CTC clusters. Using our device, we cultured a model of cancer cell aggregates of various sizes with immortalized cancer cell lines. These exhibited higher E-cadherin expression and are significantly more capable of surviving high fluid shear stress-related forces compared to single cells and model clusters grown using the control method, helping to explain why clustering may provide a metastatic advantage. Additionally, the SHArD-S, when compared with the AggreWell 800 method, provides a more consistent spheroid-forming device culturing reproducible sizes of spheroids for multiple cancer cell lines. Overall, we designed, fabricated, and validated an easily tunable engineered device which grows physiologically relevant three-dimensional (3D) cancer models containing tens to thousands of cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pick-and-Place Transfer of Arbitrary-Metal Electrodes for van der Waals Device Fabrication

Van der Waals electrode integration is a promising strategy to create nearly perfect interfaces between metals and 2D materials, with advantages such as eliminating Fermi-level pinning and reducing contact resistance. However, the lack of a simple, generalizable pick-and-place transfer technology has greatly hampered the wide use of this technique. Here, we demonstrate the pick-and-place transfer of prefabricated electrodes from reusable polished hydrogenated diamond substrates without the use of any sacrificial layers due to the inherent low-energy and dangling-bond-free nature of the hydrogenated diamond surface. The technique enables transfer of arbitrary-metal electrodes and an electrode array, as demonstrated by successful transfer of eight different elemental metals with work functions ranging from 4.22 to 5.65 eV. We also demonstrate the electrode array transfer for large-scale device fabrication. The mechanical transfer of metal electrodes from diamond to van der Waals materials creates atomically smooth interfaces with no interstitial impurities or disorder, as observed with cross-section high-resolution transmission electron microscopy and energy-dispersive X-ray spectroscopy. As a demonstration of its device application, we use the diamond transfer technique to create metal contacts to monolayer transition metal dichalcogenide semiconductors with high-work-function Pd, low-work-function Ti, and semimetal Bi to create n- and p-type field-effect transistors with low Schottky barrier heights. We also extend this technology to air-sensitive materials (trilayer 1T’ WTe 2 ) and other applications such as ambipolar transistors, Schottky diodes, and optoelectronics. This highly reliable and reproducible technology paves the way for new device architectures and high-performance devices.

2D materials↗

Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides. Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm 3 ) capable of generating an electron density of greater than 10 13 cm –3 was constructed to produce reactive species (N 2 *, N 2 +, O, OH, and H α ) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. In conclusion, this compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

On-device lead sequestration for perovskite solar cells

Perovskite solar cells (PSCs) face obstacles on their way towards commercialization. Potential issues with lead toxicity and leaching from devices remain relatively unexplored. It is desirable to develop strategies that avoid potential Pb leakage to the environment, although enhanced physical encapsulation can lessen Pb leakage from devices when subjected to mild environmental damage. We present a new chemical approach for on-device sequestration (>96%) of lead leakage caused by severe device damage without sacrificing the efficiency and stability of PSCs under normal operation.

14 SOLAR ENERGY↗

Multiparameter laser performance characterization of liquid crystals for polarization control devices in the nanosecond regime

Abstract Interactions of liquid crystals (LC’s) with polarized light have been studied widely and have spawned numerous device applications, including the fabrication of optical elements for high-power and large-aperture laser systems. Currently, little is known about both the effect of incident polarization state on laser-induced–damage threshold (LIDT) and laser-induced functional threshold (LIFT) behavior at sub-LIDT fluences under multipulse irradiation conditions. This work reports on the first study of the nanosecond-pulsed LIDT’s dependence on incident polarization for several optical devices employing oriented nematic and chiral-nematic LC’s oriented by surface alignment layers. Accelerated lifetime testing was also performed to characterize the ability of these devices to maintain their functional performance under multipulse irradiation as a function of the laser fluence at both 1053 nm and 351 nm. Results show that the LIDT varies as a function of input polarization by 30–80% within the same device, while the multipulse LIFT (which can differ from the nominal LIDT) depends on irradiation conditions such as laser fluence and wavelength.

47 OTHER INSTRUMENTATION↗

Scalable fabrication of an array-type fixed-target device for automated room temperature X-ray protein crystallography

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals. To address this need, we have developed a device that facilitates the straightforward mounting of protein crystals for diffraction analysis, and that can be easily manufactured at scale. Inspired by grid-style devices that have been reported in the literature, we have developed an X-ray compatible microfluidic device that can be used to trap protein crystals in an array configuration, while also providing excellent optical transparency, a low X-ray background, and compatibility with the robotic sample handling and environmental controls used at synchrotron macromolecular crystallography beamlines. At the Stanford Synchrotron Radiation Lightsource (SSRL), these capabilities allow for fully remote-access data collection at controlled humidity conditions. Furthermore, we have demonstrated continuous manufacturing of these devices via roll-to-roll fabrication to enable cost-effective and efficient large-scale production.

chemical engineering↗

Trade-off between processability and device performance in donor–acceptor semiconductors revealed using discrete siloxane side chains

Donor–acceptor polymeric semiconductors are crucial for state-of-the-art applications, such as electronic skin mimics. The processability, and thus solubility, of these polymers in benign solvents is critical and can be improved through side chain engineering. Nevertheless, the impact of novel side chains on backbone orientation and emerging device properties often remains to be elucidated. Here, we investigate the influence of elongated linear and branched discrete oligodimethylsiloxane (oDMS) side chains on solubility and device performance. Thereto, diketopyrrolopyrrole–thienothiophene polymers are equipped with various oDMS pendants (PDPPTT-Si n ) and subsequently phase separated into lamellar domains. The introduction of a branching point in the siloxane significantly enhanced the solubility of the polymer, as a result of increased backbone distortion. Simultaneously, the charge carrier mobility of the polymers decreased by an order of magnitude upon functionalization with long and/or branched siloxanes. This work unveils the intricate balance between processability and device performance in organic semiconductors, which is key for the development of next-generation electronic devices.

36 MATERIALS SCIENCE↗

Antifouling strategies for protecting bioelectronic devices

Bioelectronic devices are playing an increasingly important role in many areas of our lives. They power a significant portion of medical diagnostics and are becoming more and more important for delivery of therapeutics and monitoring of chronic symptoms. However, surface fouling phenomena, and especially biofouling in complex biological fluids, restricts the performance of these devices and severely reduces their useful lifespan. In this Research Update, we discuss the main principles and strategies that researchers use to prevent fouling and minimize or remove the foulants from bioelectronic device surfaces. We also survey a variety of antifouling approaches that can enhance device performance.

36 MATERIALS SCIENCE↗