Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Status of the muon neutrino charged-current zero mesons cross section measurement in the NOvA near detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement will be made with respect to the kinematics of the final state particles. Our chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and will provide a handle for constraining the cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Differential Neutral Current Elastic $ν_μ$-Argon Scattering Cross Sections with MicroBooNE

The MicroBooNE experiment is an 85 ton active mass liquid-argon time projection chamber located in the Fermilab Booster Neutrino Beamline. MicroBooNE’s ability to detect low-energy protons allows us to study single proton events with momenta as low as 300 MeV/c. We present a measurement of the flux-averaged neutral-current elastic differential cross section for neutrinos scattering on argon as functions of four-momentum transfer squared, Q 2 , proton kinetic energy, momentum and angle with respect to the beam direction. Our measured cross section as a function of Q 2 goes as low Q 2 = 0.10 GeV2 . This is our first step towards extracting the strange quark contribution to the axial form factor, which is not only the least-constrained contribution to the neutral-current elastic scattering cross section but is also crucial for understanding the strange quark contribution to the proton spin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transparent, High‐Charge Capacity Metal Mesh Electrode for Reversible Metal Electrodeposition Dynamic Windows with Dark‐State Transmission <0.1%

Abstract Dynamic windows allow user control over light and heat flow to save energy and maximize comfort. Reversible metal electrodeposition (RME) dynamic windows can uniquely tint to a color‐neutral privacy state (0.1% visible light transmission). The design parameters of transparent metal mesh counter electrodes for high‐contrast RME dynamic windows: high transparency, charge capacity and surface area with low haze, sheet resistance and cost are discussed, concluding that woven metal meshes meet these design parameters. Electroplated current is measured on an indium tin oxide electrode and two meshes with different wire spacings, showing the meshes’ cylindrical geometry enable them to draw more current per square area. The mesh material composition is analyzed to ensure cycling durability in a CuBi electrolyte by developing a transparent mesh with an inert core (stainless steel, SS), a thin Au coating, and a high charge‐capacity (1.5 C cm −2 ) CuBi outer coating. The study demonstrates that the films maintain a consistent Cu:Bi ratio and optical properties after 250 privacy cycles or 1500 cycles to 10% transmission, showing that the Cu and Bi coating is effective in keeping the films from becoming Cu rich with cycling. Finally, a 100 cm 2 device with excellent uniformity and color neutrality is demonstrated.

Yeang, Andrew L.↗

First Measurement of Charged-Current Muon-Neutrino-Induced 𝐾 + Production on Argon Using the MicroBooNE Detector

The MicroBooNE experiment is an 85 tonne active mass liquid argon time projection chamber neutrino detector exposed to the on-axis Booster Neutrino Beam at Fermilab. One of MicroBooNE’s physics goals is the precise measurement of neutrino interactions on argon in the 1 GeV energy regime. Building on the capabilities of the MicroBooNE detector, this analysis identifies 𝐾 + mesons, a key signature for the study of strange particle production in neutrino interactions. This measurement is furthermore valuable for background estimation for future nucleon decay searches and for improved reconstruction and particle identification capabilities in experiments such as the Deep Underground Neutrino Experiment. In this Letter, we present the first-ever measurement of a flux-integrated cross section for charged-current muon neutrino induced 𝐾 + production on argon nuclei, determined to be 7.93 ± 3.22⁢(stat) ± 2.83⁢(syst)×10 −42 cm 2 /nucleon based on an analysis of 6.88 × 10 20 protons on target. This result was found to be consistent with model predictions from different neutrino event generators within the reported uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New constraint on the Np 237 ( n , γ ) Np 238 integral cross section using the Godiva-IV critical assembly

Accurate knowledge of the 237 Np(n, γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. Perform a model-independent measurement of the 237 Np(n, γ) 238 Np integral cross section using a well characterized fast neutron source and compare the result with previous measurements and current nuclear data evaluations. Provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np(n, γ) 238 Np reaction and an integral cross section of 342(11) mb was measured for the Godiva-IV neutron spectrum. Further, the 238 Np half-life has been measured with a result of 50.31(5) hours. The 237 Np(n, γ) 238 Np integral cross section measured in this work is in agreement with overlapping 1σ error bands to ENDF/B-VIII.0. However, the measured value is 3σ away from the calculated integral cross section using JENDL-5. This measurement offers a reliable benchmark for future 237 Np(n, γ) 238 Np cross section evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of physical and chemical hydrology on bioremediation of a U-contaminated aquifer informed by reactive transport modeling incorporating 238 U/ 235 U ratios

Microbially-catalyzed reductive immobilization of aqueous uranium (U) as a solid phase has been proposed as a U remediation technique. Both laboratory and field experiments have demonstrated that this reduction reaction alters the 238 U/ 235 U ratio, producing a 238 U-enriched U(IV) solid. In contrast, other major U reactive transport processes fractionate these isotopes much less. This suggests the potential to quantify the extent of bioreduction occurring in groundwater containing U using the 238 U/ 235 U ratio, which would substantially improve upon current practices largely relying on U concentration measurements alone. Current reactive transport models for uranium dynamics include only concentration measurements, which are strongly influenced by highly coupled reactive transformation and aqueous transport processes. The complex physical and chemical behavior of U potentially compromises such quantitative analysis of U storage and release. Here we report the first numerical reactive transport model which explicitly incorporates variations in the 238 U/ 235 U ratio of U and demonstrates improved interpretation of the principal chemical reactions and groundwater transport processes affecting the subsurface mobility and distribution of this widespread contaminant. Recent U bioreduction studies performed in a contaminated aquifer in Rifle, Colorado, USA applied Rayleigh distillation models to interpret U stable isotope fractionation observed as a result of acetate amendment. These simplified models were unable to resolve the spatiotemporal pattern of U isotope fractionation recorded in the aqueous solutes. Here, we employ the multi-component, isotope-enabled CrunchTope reactive transport software to interpret these measured U isotope ratios, and demonstrate accurate reproduction of observed trends in both geochemistry and 238 U/ 235 U ratios for two consecutive years of field experiments. Overall, our results indicate that accurately modeling both the U concentration and isotope ratio distributions greatly constrains the parameter space of the model. We find that the transport properties of U in the Rifle aquifer are governed by the presence of low-permeability regions, which the isotopes are uniquely sensitive to. When U reduction is spatially constrained by these low-permeability regions, the shift in the 238 U/ 235 U ratio becomes more muted. Accurate modeling of observed U isotope ratios thus provides a powerful means to better understand bioremediation, and the current study serves to advance the application of this novel method.

238U/235U↗

Measurement of Kinetic-Scale Current Filamentation Dynamics and Associated Magnetic Fields in Interpenetrating Plasmas

Here, we present the first local, quantitative measurements of ion current filamentation and magnetic field amplification in interpenetrating plasmas, characterizing the dynamics of the ion Weibel instability. The interaction of a pair of laser-generated, counterpropagating, collisionless, supersonic plasma flows is probed using optical Thomson scattering (TS). Analysis of the TS ion-feature revealed anticorrelated modulations in the density of the two ion streams at the spatial scale of the ion skin depth c/ω pi = 120 μm, and a correlated modulation in the plasma current. The inferred current profile implies a magnetic field amplitude ~30 ± 6 T , corresponding to ~1% of the flow kinetic energy, indicating that magnetic trapping is the dominant saturation mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstruction of current profiles from external magnetic and MSE measurements on DIII-D

This work introduces a new current model into the EFIT code for plasma current profile reconstruction. Using this model, edge-localized current density profiles are reconstructed solely from external magnetic measurements. Quantitative comparisons show that edge current profiles obtained with the new current model align closely with those from kinetic equilibrium reconstruction. The new model enables current density reconstruction with fewer diagnostics than kinetic equilibrium reconstruction (Lao et al 1990 Nucl. Fusion 30 1035–49), demonstrating that edge-localized current density information can be obtained from external magnetic measurements only, without the help of kinetic profiles and internal diagnostics, and without using the bootstrap current model. Furthermore, with the constraints of external magnetic and MSE measurements, current profiles in full radius obtained from the new model are in good agreement with the results of kinetic equilibrium reconstruction, which not only improves the efficiency of current reconstruction but also helps avoid possible errors caused by different kinds of diagnoses. Possible applications are also discussed, and a brief analysis of the evolution of the full-radius current density is performed. Noticeable decreases in both the magnitude and gradient of the edge current around the time of ELM bursts are observed. Moreover, analysis of the full radius current density profiles ( ρ N = 0 − 1.0, ρN denotes to square root of the normalized toroidal flux) reveals that as the edge current changes, the inner current also changes following a sinusoidal-like pattern at almost all time slices during four type-I ELMs in discharge 161493. The current evolution in the inner region ( ρ N = 0.2 − 0.6) is synchronized with the boundary region ( ρ N = 0.89 − 1.0), while the intermediate region ( ρ N = 0.6 − 0.89) shows opposite behavior. This sinusoidal-like variations in full-radius current density profile indicates strong core-pedestal coupling, suggesting ELMs significantly affect core plasmas, though current changes manifest differently across radial regions.

EFIT↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

A Hybrid DC Fault Primary Protection Algorithm for Multi-Terminal HVdc Systems

Protection against dc faults is one of the main technical hurdles faced when operating converter-based HVdc systems. Protection becomes even more challenging for multi-terminal dc (MTdc) systems with more than two terminals/converter stations. In this paper, a hybrid primary fault detection algorithm for MTdc systems is proposed to detect a broad range of failures. Sensor measurements, i.e., line currents and dc reactor voltages measured at local terminals, are first processed by a top-level context clustering algorithm. For each cluster, the best fault detector is selected among a detector pool according to a rule resulting from a learning algorithm. The detector pool consists of several existing detection algorithms, each performing differently across fault scenarios. The proposed hybrid primary detection algorithm: i) offers superior performance compared to an individual detector through a data-driven approach; ii) detects all major fault types including pole-to-pole (P2P), pole-to-ground (P2G), and external dc faults; iii) identifies faults with various fault locations and impedances; iv) is more robust to noisy sensor measurements compared to existing methods; v) does not require exhaustive simulation and sampling for training the model. Performance and effectiveness of the proposed algorithm are evaluated and verified based on time-domain simulations in the PSCAD/EMTDC software environment. The results confirm satisfactory operation, accuracy, and detection speed of the proposed algorithm under various fault scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Acoustic Particle Velocity Measurements around a Tidal Current Turbine

Quantifying the underwater sound produced by tidal turbines is essential both to understand their potential environmental impacts and to understand how that sound might interfere with the intended application of the turbine (e.g., powering acoustic monitoring systems). In this project, we measured the sound radiated by a small-scale crossflow tidal turbine. The turbine was deployed from October 2023 to March 2024 in the tidal channel at the entrance to Sequim Bay, WA. Acoustic measurements were made with three different sensor packages: a commercial-off-the-shelf vector sensor (operated by PNNL), a vector sensor array (operated by Integral Consulting), and drifting hydrophones (operated by UW). Acoustic recordings from the three sensors highlight changes in the turbine acoustic signature over the course of a tidal cycle and throughout the 6-month turbine deployment. Our results also highlight the utility of acoustic vector sensors for localizing sound attributable to marine energy devices in acoustically complex environments.

16 TIDAL AND WAVE POWER↗

First Measurement of Inclusive Muon Neutrino Charged Current Triple Differential Cross Section on Argon

The field of accelerator neutrino experiments is entering an era of precision oscillation measurements where the remaining unknown neutrino measurements will be determined. The upcoming DUNE and Hyper-K experiments aim to determine the neutrino mass hierarchy and degree of Charge-Parity (CP) violation in the neutrino sector, providing potential insight on the matter-antimatter imbalance observed in the universe. However, these experiments require highly accurate measurements, and neutrino cross section modeling uncertainties may limit their capabilities. Cross section measurements at current- generation experiments can aid the development of neutrino interaction models to reduce these uncertainties. This is especially true for measurements of neutrino energy, as it drives neutrino oscillations and is of key importance to oscillation experiments. The MicroBooNE experiment uses a Liquid Argon Time Projection Chamber (LArTPC) to produce neutrino-argon cross sections as one of its physics goals. The MicroBooNE detector’s fully active volume, precision reconstruction, and calorimetry information are leveraged in the Wire-Cell analysis to produce a muon neutrino selection that is 92% pure while maintaining 68% efficiency. A reconstruction chain featuring a fully 3D charge reconstruction and a graph-based particle trajectory fit are used to produce accurate measurements of lepton kinematics as well as visible hadronic energy produced in a neutrino interaction. This thesis presents the first neutrino-argon triple-differential cross section measurement, targeting inclusive charged-current final states. Wiener SVD unfolding is used to produce a measurement over neutrino energy, muon momentum, and muon scattering angle. A series of constrained goodness of fit tests are used to demonstrate the validity of MicroBooNE’s model in describing the distribution of reconstructed kinematics seen in data to ensure the accuracy of unfolding. The validated unfolding to neutrino energy represents a step forward in the field of neutrino cross sections, and demonstrates the capabilities of the LArTPC detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement Of Charged-current 1 Muon 2 Proton 0 Pion Single Differential Cross-sections On Argon-40 At 0.8 Gev Average Neutrino Energy With The MicroBooNE Detector

Constraining systematic uncertainties that arise from neutrino-nucleon cross-section modeling is critical for upcoming neutrino oscillation experiments. Neutrino interactions that lead to the ejection of 2 particles from the target nucleus, leaving the nucleus with 2 holes, are one cross-section of interest. These instances, known as 2-particle 2-hole (2p2h) states, can be produced either by neutrino interaction modes or from the influence of nuclear physics on the neutrino interaction. While there are many theoretical models that attempt to describe the nature of 2p2h states, very few experimental measurements of this process exist, making it difficult to benchmark theoretical calculations. Furthermore, no high statistic cross-section measurements of 2p2h states exist on $^{40}$Ar, the target nucleus of many current and next generation neutrino oscillation experiments. This analysis aims to address this issue by providing the first high-statistic single differential cross-section me asurements of 2p2h states. Using data collected from the first 3 years of running of the MicroBooNE experiment, we select $\nu_\mu$ charged-current interaction events that produce a single muon, 2 protons, and no pions in the final state (CC1$\mu$2p0$\pi$). The single differential cross-section is then extracted as a function of a variety of physics variables and compared to theoretical predictions from several event generator model sets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transport and relaxation of current-generated nonequilibrium phonons from nonlocal electronic measurements

We study phonons generated by current in a Pt nanowire by measuring the resistance of another nanowire separated from the first one by an insulating spacer. For thin spacers, the resistance varies almost linearly with current at cryogenic temperatures, while an additional quadratic contribution emerges for thicker spacers. These observations suggest a nonthermal distribution of current-generated phonons that relax via strongly nonlinear dynamical processes rather than few-phonon scattering. Our results provide insight into the nonequilibrium phonon dynamics at nanoscale, which may facilitate efficient heat management in electronic nanodevices.

36 MATERIALS SCIENCE↗

D 3 -creatine dilution for skeletal muscle mass measurement: historical development and current status

The French chemist Michel Eugène Chevreul discovered creatine in meat two centuries ago. Extensive biochemical and physiological studies of this organic molecule followed with confirmation that creatine is found within the cytoplasm and mitochondria of human skeletal muscles. Two groups of investigators exploited these relationships five decades ago by first estimating the creatine pool size in vivo with 14 C and 15 N labelled isotopes. Skeletal muscle mass (kg) was then calculated by dividing the creatine pool size (g) by muscle creatine concentration (g/kg) measured on a single muscle biopsy or estimated from the literature. This approach for quantifying skeletal muscle mass is generating renewed interest with the recent introduction of a practical stable isotope (creatine-(methyl-d 3 )) dilution method for estimating the creatine pool size across the full human lifespan. The need for a muscle biopsy has been eliminated by assuming a constant value for whole-body skeletal muscle creatine concentration of 4.3 g/kg wet weight. The current single compartment model of estimating creatine pool size and skeletal muscle mass rests on four main assumptions: tracer absorption is complete; tracer is all retained; tracer is distributed solely in skeletal muscle; and skeletal muscle creatine concentration is known and constant. Three of these assumptions are false to varying degrees. Not all tracer is retained with urinary isotope losses ranging from 0% to 9%; an empirical equation requiring further validation is used to correct for spillage. Not all tracer is distributed in skeletal muscle with non-muscle creatine sources ranging from 2% to 10% with a definitive value lacking. Lastly, skeletal muscle creatine concentration is not constant and varies between muscles (e.g. 3.89–4.62 g/kg), with diets (e.g. vegetarian and omnivore), across age groups (e.g. middle-age, ~4.5 g/kg; old-age, 4.0 g/kg), activity levels (e.g. athletes, ~5 g/kg) and in disease states (e.g. muscular dystrophies, <3 g/kg). Some of the variability in skeletal muscle creatine concentrations can be attributed to heterogeneity in the proportions of wet skeletal muscle as myofibres, connective tissues, and fat. These observations raise serious concerns regarding the accuracy of the deuterated-creatine dilution method for estimating total body skeletal muscle mass as now defined by cadaver analyses of whole wet tissues and in vivo approaches such as magnetic resonance imaging. A new framework is needed in thinking about how this potentially valuable method for measuring the creatine pool size in vivo can be used in the future to study skeletal muscle biology in health and disease.

body composition↗

Near surface defects: Cause of deficit between internal and external open-circuit voltage in solar cells

The presence of interface recombination in a complex multilayered thin-film solar structure causes a disparity between the internal open-circuit voltage (V OC,in ), measured by photoluminescence, and the external open-circuit voltage (V OC,ex ) i.e. an additional V OC deficit. Higher V OC,ex value aim require a comprehensive understanding of connection between V OC deficit and interface recombination. Here, a deep near-surface defect model at the absorber/buffer interface is developed for copper indium di-selenide solar cells grown under Cu excess conditions to explain the disparity between V OC ,in and V OC,ex . The model is based on experimental analysis of admittance spectroscopy and deep-level transient spectroscopy, which show the signature of deep acceptor defect. Further, temperature-dependent current-voltage measurements confirm the presence of near surface defects as the cause of interface recombination. The numerical simulations show strong decrease in the local V OC ,in near the absorber/buffer interface leading to a V OC deficit in the device. This loss mechanism leads to interface recombination without a reduced interface bandgap or Fermi level pinning. Further, these findings demonstrate that the V OC ,in measurements alone can be inconclusive and might conceal the information on interface recombination pathways, establishing the need for complementary techniques like temperature dependent current voltage measurements to identify the cause of interface recombination in the devices.

14 SOLAR ENERGY↗