At least 253 records · Page 14

Final Design for Thermal/Epithermal eXperiments using High 240 Pu Content Plutonium/Aluminum Zero Power Research Reactor Plates with Polyethylene Moderator (IER 520 Final Design CED-2 Report)

The US Department of Energy Nuclear Criticality Safety Program (NCSP) convened a multinational Thermal Epithermal eXperiments (TEX) meeting in July of 2011 to discuss the data and experimental needs of criticality safety practitioners. The number one and two priority integral experiment data needs were for 239 Pu and 240 Pu, with special emphasis on cross section performance in the intermediate energy range (from 0.625 eV to 100 keV). LLNL measured five critical configurations with LANL for the plutonium test bed (IER-184) and published the experiments as International Criticality Safety Benchmark Evaluation Project evaluation PUMET-MIXED-002. Modeling of the benchmark configurations using ENDF/B-VIII.0 nuclear data showed significant overprediction of reactivity for configurations that had a large percentage of fissions in the intermediate energy regime. This report documents a variation on the TEX plutonium test bed to provide a test of 240 Pu cross sections, with sensitivity of the configuration to 240 Pu radiative capture and fission cross sections a priority for the design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Semi-Empirical Density Law for Ternary, Homogeneous PuCl 3 /HCl/H 2 O Solutions

Nuclear material operations pose unique hazards that are not encountered in other chemical, energy, or manufacturing industries. One of these hazards is the potential for a nuclear criticality accident when handling fissile isotopes such as 235 U and 239 Pu. These hazards are particularly high when fissile material is dissolved in solution as the neutron behaviors of the system can change rapidly with the physical and chemical changes accessible in solution. Current estimates of solution density used for criticality safety are outdated and hinder fissile material handling. Developing new estimates for these safety calculations requires experimental characterization and the derivation of empirical density models. We have derived a density law describing PuCl 3 /HCl/H 2 O solutions from experimental data characterizing solution density. Density data was treated using a Pitzer-derived eight-parameter equation, defining density as a function of analyte concentrations, temperature, and interactions between these variables. The model is predictive across the concentration and temperature ranges from which it was derived. The potential effects of varying oxidation states of plutonium, which are easily accessible in aqueous media, on the bulk solution density of the ternary system were also investigated. The resulting Pitzer-derived density law was applied to a nuclear criticality safety model, and the impact of the experimental characterization of solution density relative to previous estimates was demonstrated to be significant and suggest that the current approach to estimating density in nuclear criticality safety calculations may lead to overly conservative controls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Python Tool for Aqueous Plutonium Nitrate Density Law Input Preprocessing in MCNP6

Here, this work develops a predictive density tool in Python, named Plutonium Nitrate Solutions (PuNS), to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer method and an empirical method were implemented into the PuNS tool to generate atom densities for use in MCNP6 material cards. These material cards are directly prepared into an MCNP6 input text file and are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, and plutonium isotope weight percentages. The PuNS tool is validated and verified against the International Criticality Safety Benchmark Evaluation Project Handbook experiments and is observed to predict densities within a root mean square error of 0.89% for the Pitzer method and 1.82% for the empirical method. These errors in density lead to up to 1569 pcm difference in MCNP6 calculated k eff for the Pitzer method and up to a 1751 pcm difference for the empirical method when compared to experimental benchmarks. Simultaneous work is also being performed at Los Alamos National Laboratory and the University of New Mexico to create a similar tool for plutonium chloride solutions, named Plutonium Chloride Solution, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also facilitate an improved understanding of solution systems and a potential relaxation in the conservatism of current aqueous plutonium processing criticality safety limits.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Planet Operations at NCERC

Planet is a vertical-lift assembly machine currently located at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. In the past, Planet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). Following the de-inventorying of LACEF, the Planet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The Class Foils experiment, which involves stacking highly enriched uranium foils to obtain a critical configuration, was the first critical experiment performed on Planet. As a major component of the Nuclear Criticality Safety Class taught for the U.S. Department of Energy (DOE) Nuclear Criticality Safety Program, the Class Foils experiment allows personnel from all over the DOE complex to handle nuclear material and to complete the approach to critical safely and successfully. This paper describes the Planet vertical assembly and recent engineering upgrade and a selection of the experiments that have been performed on Planet since its transition to NCERC 10 years ago.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE 6.2.4: Validation Overview

SCALE is a multi-application code system with tools for reactor physics, criticality safety, radiation shielding, and spent fuel characterization for a range of nuclear systems. The last of the SCALE 6.2 series, version 6.2.4, was released in June 2020. Validation studies in nuclear criticality safety, reactor physics, and shielding applications were performed to confirm results, assess accuracy, and identify biases from SCALE simulations. Nuclear criticality safety applications yield small code biases for a wide range of systems, generally overestimating cross section uncertainty. Reactor physics applications improvements in nuclide inventory and full-core eigenvalue predictions, with similar performance in decay heat predictions. Radiation shielding applications yield sufficient agreement in comparisons to measurements and alternate simulations for eight shielding experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic value of the international benchmark projects, ICSBEP and IRPhEP, for advanced reactor development

The International Criticality Safety Benchmark Evaluation Project, a sanctioned program under the auspices of the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development, has been a highly successful and productive collaboration, now encompassing over 5,000 evaluated experimental benchmarks trusted and relied upon throughout the international nuclear communities. The success of this project led to the development of the International Reactor Physics Experiment Evaluation Project, which is dedicated to the evaluation of benchmark experiment data to sustain current and future reactor physics validation needs. These exemplary programs, and their widely utilized handbooks, serve as gold standards to which other databases strive to emulate. The purpose of the two projects is to preserve modern and legacy experimental data and evaluate it in a standardized handbook format to provide quality benchmarks to support modern and future criticality safety and reactor physics validation. These two projects have often served as the mechanism through which historic and modern neutronics experiments are evaluated and shared across international borders, to best provide unique, high-quality peer-reviewed, and often otherwise unavailable, benchmark data. The contents of these handbooks are utilized not only in validating criticality safety, reactor physics, and advanced reactor calculations, but are used to validate neutronics calculations and nuclear data for most other nuclear applications. This paper discusses both international programs and available content to enable advanced reactor design validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the New MCNP6.3 Criticality Features

The MCNP6® code, version 6.3, has been extensively verified and validated for many applications. The use of the same default capabilities existing in the MCNP6.2 code are also used in the verification and validation (V&V) of the MCNP6.3 code. In this paper, selected new features, code enhancements, and bug fixes in the MCNP6.3 code that impact criticality safety applications are described and investigated. More specifically, the changes within the MCNP6.3 code that are studied in this work include both the new fission matrix and the Doppler broadening resonance correction (DBRC) features. For nuclear criticality safety applications, the V&V benchmark problems within the criticality, extended criticality, and Rossi-α suites are used to study the upgrades within the MCNP6.3 code. Some additional investigations into benchmarks at elevated temperatures are used to showcase the impacts of the temperature-specific capabilities.

97 MATHEMATICS AND COMPUTING↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE

Analyses of cross section sensitivity data from systems with fissile material allow analysts to associate an importance for each material, nuclide, reaction, and neutron energy by simulating real world criticality scenarios. Although criticality safety validation efforts can be guided by the cross-section sensitivity and uncertainty data generated for a particular system, these calculations can often be computationally expensive and sometimes cumbersome without proper guidance. The TSUNAMI suite within the SCALE code package has several methods for generating sensitivity data, including multigroup and continuous energy (CE) capabilities. The release of SCALE 6.3 has three different CE methods for generating cross section sensitivity data: (1) the Iterated Fission Probability (IFP) method with the KENO Monte Carlo transport solver, (2) the IFP method with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method with the KENO Monte Carlo transport solver. Although the CLUTCH method has additional parameters for generating sensitivity data files relative to the IFP method, all three methods use latent generations, which are the generations between an event (i.e., fission) and the assessment of importance based on the asymptotic population of progeny neutrons. Increasing the number of latent generations in a calculation leads to increased discrimination of the sensitivity coefficients but at the cost of the increased uncertainty associated with those generated values. Analysts must balance the accuracy of the sensitivity calculations and its uncertainty with the associated computational cost involved in generating the values. This paper discusses the impact of adjusting the latent generation parameter for a range of sensitivity values and how these changes compare with the direct perturbation values obtained from a change of ±0.5% Δ k in both benchmark and safety application models. Two benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the MPC-32 dual purpose canister for spent nuclear fuel are used for analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of Critical Experiments Involving Graphite elements at the IPEN/MB-01 Plate-Type Core

A series of critical experiments were designed involving the use of characterized graphite elements in the new plate-type core of the IPEN/MB-01 reactor. Eleven configurations with different graphite quantities are considered, each producing distinct effects on neutron fluxes and offering opportunities to analyze varying sensitivities to k eff in the system. The analysis shows that the experiments can be performed with acceptably low k eff uncertainties considering an adequate characterization of the graphite elements to be used. The sensitivity results obtained using SCALE TSUNAMI calculations show that the experiments have a notable k eff sensitivity coefficient to graphite. In the configurations tested, the k eff sensitivity to graphite TSL is low. This experiment will be useful for criticality safety validation of applications using uranium fuel enriched to around 19.75 wt % 235 U, light water and graphite. It will also be useful to gain more insight into graphite material properties and their effect on k eff as a result of using the well-characterized graphite elements. The execution of the experiments is planned for the summer of 2025. The 11 designed configurations serve as a basis for the final design, and fewer configurations will be executed. Once executed, these critical experiments will be evaluated and submitted for publication in the International Criticality Safety Benchmark Evaluation Project Handbook, supporting the DOE/NRC Collaboration for Criticality Safety Support for Commercial-Scale HALEU for Fuel Cycles and Transportation project goal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Chlorine Worth Study Benchmark Evaluation

The Chlorine Worth Studies (CWS) experiments with polyvinyl chloride (PVC with chemical formula (C 2 H 3 Cl) n ), chlorinated polyvinyl chloride (CPVC with chemical formula (C 9 H 11 Cl 7 ) n ), and high density polyethylene (HDPE with chemical formula (CH 2 ) n ) were a series of measurements performed at the National Criticality Experiments Research Center (NCERC). The purpose of the CWS experiments was to perform integral experiments that were highly sensitive to the thermal 35 Cl(n,γ) reaction and matched the sensitivities of aqueous chloride operations at the plutonium facility at Los Alamos National Laboratory (LANL). The CWS experiments were performed on the Planet critical assembly machine at NCERC and utilized weapons grade plutonium (WGPu) plates as fuel. The design process and design of the CWS experiment were discussed previously. This paper discusses the benchmark evaluation of the experiment, intended for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Criticality calculations were performed with MCNP version 6.3. Results presented here are preliminary, as the benchmark has not yet been submitted to the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical Simulation Pipeline for COG Suites [Poster]

The CRItical Simulation Pipeline (CRISP) is a Python package for automating validation of reactor criticality benchmarks. CRISP supplies COG—a multi-particle radiation transport code maintained by the Nuclear Criticality Safety Division—with a pipeline to calculate k eff performance for 400+ benchmark experiments with 3,400+ configurations from the International Criticality Safety Benchmark Evaluation Project (ICSBEP). The pipeline includes four stages: materials configuration, input card templating, cluster submission, and results analysis. CRISP includes a command-line interface to facilitate user interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of MCNP Critical Benchmark Models of PU-MET-FAST-016

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The repository is the combined effort of the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The initial set of benchmark models in the repository are derived from the Whisper Suite provided with MCNP6.2 and are evaluated against the benchmark experiments described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with PU-MET-FAST-016, “Flooded 3X3X3 Arrays of 3-kg Plutonium (Pu) Metal Cylinders – Phase I”. In this critical experiment, twenty-seven 3-kg Pu metal cylinders with a height of 46.33 ± 0.15 mm and diameter of 65.25 ± 0.05 mm were arranged in a cubic array. The Pu cylinders were sealed in aluminum cans, and three cans were placed in each of nine perforated aluminum sleeves, as shown in Fig. 1. The nine sleeves were supported by an aluminum frame that allowed for control of the lateral spacing of the cylinders, both in the X and Y directions. The benchmark experiment measured thirteen configurations. Of these configurations, six were modeled using MCNP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generating Models of the Flattop Critical Assembly for Benchmark Experiments with Python

Los Alamos National Laboratory has been performing nuclear criticality experiments since 1946 at the Pajarito site, starting the Los Alamos Critical Experiments Facility in 1948. A transition period occurred between 2004 and 2011 as operations moved to the National Criticality Experiments Research Center (NCERC), where criticality experiments are now performed. Criticality experiments are essential for determination and verification of nuclear data used in calculations and modeling—such as radiation transport codes—throughout the industry, enhancing nuclear criticality safety. In addition to nuclear data validation and benchmarking, the remotely operated critical assemblies at NCERC are used for a variety of experiments and training classes supporting criticality safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Testing of Multiple Graphite Benchmarks [Slides]

Integral criticality safety and reactor physics benchmark experiments from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) and the International Handbook of Reactor Physics Experiments (IRPhE Handbook) are essential for nuclear data validation and testing

ENDF↗

Lessons Learned From Ventilation and Glovebox Flooding Via Overfilling of the Wet Vacuum System in a Plutonium Facility

In the summer of 2021, operations personnel requested maintenance personnel to fill a wet vacuum (Wetvac) seal water tank in a plutonium facility at Los Alamos National Laboratory (LANL). After the filling was finished, the fill valve of the Wetvac seal water tank was left open and a ‘dead-man’ valve on an isolation line failed to close properly. After a series of other failures, the water exited the glovebox and contaminated three rooms of the first floor of the facility and an underlying area in the basement. A retrospective analysis of this event determined that there was no risk of a criticality due to the inherent design features of the ventilation system. This paper will explain the driving factors behind how this event was able to happen, as well as some of the major lessons learned that can be universally applied to other nuclear facilities. One of the main causes of the event was the delegation of work to maintenance personnel that were not qualified for the work being asked of them. Additionally, there was a lack of coordination between criticality safety engineers and facility operations equipment owners regarding equipment and connections present on the seal water tanks for the Wetvac, specifically the presence of overflow drain lines. The respective criticality safety evaluation credited an overflow drain line being present on the seal water tanks that was later found to have not been present. Lastly, there are lessons to be learned regarding equipment configuration and designing systems with safety in mind.