Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contingency Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Interactive Effects of Microbes and Nitrogen on Panicum virgatum Root Functional Traits and Patterns of Phenotypic Selection

Premise of research. Plants in natural and agricultural systems are influenced in myriad ways by their microbial communities, particularly by providing goods and services that change plant functional traits. Microbes are considered an influential part of the environmental context that change plant trait expression, but often, microbe-mediated effects are contingent on local resources, such as nitrogen. Here, we ask how microbes and nitrogen affect belowground functional traits and patterns of phenotypic selection. Methodology. We performed a fully factorial greenhouse experiment with switchgrass (Panicum virgatum), manipulating microbial community composition and nitrogen availability. We measured plant performance and belowground functional traits and performed 16S amplicon sequencing of the root-associated microbial communities. We looked for correlations between microbial taxa and root functional traits, and we performed phenotypic selection analysis on five belowground functional traits to determine how traits affect plant relative performance across biotic and abiotic contexts. Pivotal results. All belowground plant functional traits except root tissue density were affected by adding nitrogen. We found that a microbial taxon (amplicon sequence variant [ASV]) in the genus Micromonospora correlated with shorter root lengths. We also found strong positive selection for longer roots regardless of the abiotic or biotic environment. In contrast, selection favored lower root-to-shoot ratios in high-nitrogen conditions, and selection on root tissue density was highest in treatments that had high nitrogen levels and perturbed microbial communities. Conclusions. We did not detect microbial effects on the expression of plant traits (ecological effects); however, patterns of phenotypic selection (evolutionary effects) on root tissue density differed depending on the biotic and abiotic environment. Additionally, we detected strong selection for increased root length across treatments; we also found that one ASV correlated with decreased root length, indicating potential conflict between root microbiome components and plant fitness. Future work would be to include microbial taxa in phenotypic selection analysis and to conduct manipulations of the microbes correlated with functional traits to determine causality.

59 BASIC BIOLOGICAL SCIENCES↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating residential AC load control into ancillary service markets: Measurement and settlement

Many pre-existing air conditioner load control programs can provide valuable operational flexibility but have not been incorporated into electricity ancillary service markets or grid operations. Multiple demonstrations have shown that residential air conditioner (AC) response can deliver resources quickly and can provide contingency reserves. A key policy hurdle to be overcome before AC load control can be fully incorporated into markets is how to balance the accuracy, cost, and complexity of methods available for the settlement of load curtailment. Overcoming this hurdle requires a means for assessing the accuracy of shorter-term AC load control demand reduction estimation approaches in an unbiased manner. This paper applies such a method to compare the accuracy of approaches varying in cost and complexity ? including regression analysis, load matching and control group approaches ? using feeder data, household data and AC end-use data. We recommend a practical approach for settlement, relying on an annually updated set of tables, with pre-calculated reduction estimates. These tables allow users to look up the demand reduction per device based on daily maximum temperature, geographic region and hour of day, simplifying settlement and providing a solution to the policy problem presented in this paper.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost Recovery for Standby and Ancillary Services for Distributed Generation: Considerations for New Mexico

A New Mexico statute allows investor-owned utilities to recover costs of “standby and ancillary services” resulting from distributed generation (DG). In attempting to do so, it is important to recognize both the physical and economic impacts, positive and negative, that distributed generation creates. Distributed generation has different impacts on ancillary and standby services depending on the location, capacity, and production patterns of the systems. Low penetrations of small distributed generation systems will not create significant contingencies for utilities. System impact of fluctuations in DG production may be no larger than normal fluctuations caused by customer demand, such as an air conditioner cycling. Higher penetrations and large DG system may produce noticeable impacts; so magnitude is critical when determining potential additional recoverable utility costs. Understanding DG impact on ancillary services is a relatively new and emerging area of study and as such there are not well-established formulas or protocols. Discretion is required. A hosting capacity analysis can help determine how much DG can be implemented before the impacts become substantive. Standby rates are traditionally used for large industrial generators or combined heat and power systems and threshold system size levels are often used in determining applicability of standby rates. System size thresholds may also be appropriate for standby rates and DG. Relatively small, geographically diverse DG systems are unlikely to create a noticeable coincident outage, so developing a standby charge based on assumed coincidence may not be appropriate. Individual lines and feeders may have considerable excess capacity during coincident outages, or they may be fully utilized and facing upgrades in the near future, which could vary over time. Understanding specific events that create concern for utilities is critical to developing an appropriate rate mechanism (e.g., single residential or community system outage, cascading event, clouds, eclipse). Any modeling or studies of the grid should also recognize the unique situation created when DG is coupled with a smart inverter or storage. These devices change the value proposition and can help mitigate some of the voltage and ramping issues DG can pose for a utility. Utilities can recover their fixed costs in a variety of ways, and some are better suited for DG than others. Beyond charging for standby and ancillary services, other options include fixed customer charges, demand charges, minimum bills, time-of-use rates and updated net energy-metering policies. Studies and analyses of the specific impacts that DG has on the grid should inform utilities’ decision-making process because distributed generation creates both costs and benefits for the grid. Any charge specific to DG customers should be backed up with analysis. At the heart of this conversation is utilities attempting to recover fixed costs. Allowing utilities to indiscriminately recover all stranded fixed costs can negatively affect long-term market efficiency by blunting utility incentives to lower costs and acting as a barrier to entry and exit. The current status of New Mexico’s grid, impending infrastructure updates, and likely customer adoption patterns for DG (backed up by transparent analysis) should remain at the forefront when considering charges for standby and ancillary services. Recognizing that utility regulation is largely a reactive process, it is recommended that applications for DG related standby or ancillary services cost recovery mechanisms be thoroughly reviewed by an experienced economist. If the commission has no such skill set on staff, one might be hired.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The role of annealing and grain boundary controls on the mechanical properties of limestones and marbles

Chemical and mechanical processes are coupled in many geological and geochemical environments. Reactive processes anneal defects and restructure grain boundaries, modifying their elastic properties, levels of internal friction, wave propagation rates and fracture behaviors. The nature of these changes is, however, contingent on the initial state of the rock. Here, in this study, impulse excitation was used to measure changes in mechanical properties as a function of dry and steam heating time at 300 °C for three carbonate rocks: Carrara marble, Carthage marble (Burlington Limestone), and Texas Cream limestone (Edwards limestone), with initial porosities of about 1 %, 3 %, and 27 %, respectively. Frequency-dependent phenomena along with mineral recrystallization were observed. This was coupled with small-angle X-ray and neutron scattering analysis to determine the relationship between changes in bulk mechanical and microstructural properties. An observed decrease in both the Young's and shear moduli in the experimental limestones as a function of heating time reflects and quantifies a reduction in the stiffness of the rock due to annealing. The internal friction of the samples first increases then decreases with reaction time, reflecting defect annealing, but this was balanced against grain boundary dissolution apparently driven by condensation of steam in the confined grain-boundary environment. This suggests an increase in the boiling point under confinement leading to dissolution, increased porosity and widening of the grain boundaries. In addition, comparison of small-angle X-ray and neutron scattering results suggests that it is inappropriate to assume that pores are empty for quantitative analysis of typical small-angle scattering samples.

58 GEOSCIENCES↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Robust and Versatile Method of Combinatorial Chemical Synthesis of Gene Libraries via Hierarchical Assembly of Partially Randomized Modules

A major challenge in gene library generation is to guarantee a large functional size and diversity that significantly increases the chances of selecting different functional protein variants. The use of trinucleotides mixtures for controlled randomization results in superior library diversity and offers the ability to specify the type and distribution of the amino acids at each position. Here we describe the generation of a high diversity gene library using tHisF of the hyperthermophile Thermotoga maritima as a scaffold. Combining various rational criteria with contingency, we targeted 26 selected codons of the thisF gene sequence for randomization at a controlled level. We have developed a novel method of creating full-length gene libraries by combinatorial assembly of smaller sub-libraries. Full-length libraries of high diversity can easily be assembled on demand from smaller and much less diverse sublibraries, which circumvent the notoriously troublesome long-term archivation and repeated proliferation of high diversity ensembles of phages or plasmids. We developed a generally applicable software tool for sequence analysis of mutated gene sequences that provides efficient assistance for analysis of library diversity. Finally, practical utility of the library was demonstrated in principle by assessment of the conformational stability of library members and isolating protein variants with HisF activity from it. Our approach integrates a number of features of nucleic acids synthetic chemistry, biochemistry and molecular genetics to a coherent, flexible and robust method of combinatorial gene synthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Eastern Renewable Generation Integration Study

The Eastern Interconnection (EI) is one of the largest power systems in the world, and its size and complexity have historically made it difficult to study in high levels of detail in a modeling environment. In order to understand how this system might be impacted by high penetrations (30% of total annual generation) of wind and solar photovoltaic (PV) during steady state operations, the National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy (DOE) conducted the Eastern Renewable Generation Integration Study (ERGIS). This study investigates certain aspects of the reliability and economic efficiency problem faced by power system operators and planners. Specifically, the study models the ability to meet electricity demand at a 5-minute time interval by scheduling resources for known ramping events, while maintaining adequate reserves to meet random variation in supply and demand, and contingency events. To measure the ability to meet these requirements, a unit commitment and economic dispatch (UC&ED) model is employed to simulate power system operations. The economic costs of managing this system are presented using production costs, a traditional UC&ED metric that does not include any consideration of long-term fixed costs. ERGIS simulated one year of power system operations to understand regional and sub-hourly impacts of wind and PV by developing a comprehensive UC&ED model of the EI. In the analysis, it is shown that, under the study assumptions, generation from approximately 400 GW of combined wind and PV capacity can be balanced on the transmission system at a 5-minute level. In order to address the significant computational burdens associated with a model of this detail we apply novel computing techniques to dramatically reduce simulation solve time while simultaneously increasing the resolution and fidelity of the analysis. Our results also indicate that high penetrations of wind and PV (collectively variable generation (VG)), significantly impact the operation of traditional generating resources and cause these resources to be used less frequently and operate across a broader output range because wind and PV have lower operating costs and variable output levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation of Citation-Based Scholarly Activity Among Radiation Oncology Faculty at Domestic Residency-Training Institutions: 1996-2007

Purpose: Advancement in academic radiation oncology is largely contingent on research productivity and the perceived external influence of an individual's scholarly work. The purpose of this study was to use the Hirsch index (h-index) to estimate the research productivity of current radiation oncology faculty at U.S. academic institutions between 1996 and 2007. Methods and Materials: We performed bibliometric citation database searches for available radiation oncology faculty at domestic residency-training institutions (n = 826). The outcomes analyzed included the total number of manuscripts, total number of citations, and the h-index between 1996 and 2007. Analysis of overall h-index rankings with stratification by academic ranking, junior vs. senior faculty status, and gender was performed. Results: Of the 826 radiation oncologists, the mean h-index was 8.5. Of the individuals in the top 10% by the h-index, 34% were chairpersons, 88% were senior faculty, and 13% were women. A greater h-index was associated with a higher academic ranking and senior faculty status. Recursive partitioning analysis revealed an h-index threshold of 15 (p <0.0001) as an identified breakpoint between the senior and junior faculty. Overall, women had lower h-indexes compared with men (mean, 6.4 vs. 9.4); however, when stratified by academic ranking, the gender differential all but disappeared. Conclusion: Using the h-index as a partial surrogate for research productivity, it appears that radiation oncologists in academia today comprise a prolific group, however, with a highly skewed distribution. According to the present analysis, the h-index correlated with academic ranking. Thus, it potentially has utility in the process of promotion decisions. Overall, women in radiation oncology were less academically productive than men; the possible reasons for the gender differential are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using landscape typologies to model socioecological systems: Application to agriculture of the United States Gulf Coast

Agricultural enterprises are vulnerable to the effects of climate variability and change. Improved understanding of the determinants of vulnerability and adaptive capacity in agricultural systems is important for projecting and managing future climate risk. At present, three analytical tools dominate methodological approaches to understanding agroecological vulnerability to climate: process-based crop models, empirical crop models, and integrated assessment models. A common weakness of these approaches is their limited treatment of socio-economic conditions and human agency in modeling agroecological processes and outcomes. This study proposes a framework that uses spatial cluster analysis to generate regional socioecological typologies that capture geographic variance in regional agricultural production and enable attribution of that variance to climatic, topographic, edaphic, and socioeconomic components. This framework was applied to historical corn production (1986-2010) in the U.S. Gulf of Mexico region as a testbed. The results demonstrate that regional socioeconomic heterogeneity is an important driving force in human dominated ecosystems, which we hypothesize, is a function of the link between socioeconomic conditions and the adaptive capacity of agricultural systems. Meaningful representation of future agricultural responses to climate variability and change is contingent upon understanding interactions among biophysical conditions, socioeconomic conditions, and human agency their incorporation in predictive models.

58 GEOSCIENCES↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Annual report of monitoring at Barnes, Kansas, in 2010.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, in 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). The results of that investigation indicated that carbon tetrachloride contamination is present in groundwater at low to moderate levels in the vicinity of the former CCC/USDA grain storage facility. Information obtained during the 2006-2007 investigation also indicated that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). The former agriculture building owned by the local school district, located immediately east of well PWS3, is also a potential source of the contamination. In November 2007, the CCC/USDA began periodic groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, under the direction of the Kansas Department of Health and Environment (KDHE). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. Through 2010, sampling was conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events (Argonne 2008a-d, 2009a,b, 2010) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Long-term monitoring of the groundwater levels and the contaminant distribution has confirmed that pumping of the public water supply wells affects the direction of groundwater flow. When these wells are not pumping, the direction of groundwater flow is to the northeast. However, when they are pumping, groundwater flow is directed to the northwest, toward the public wells. A contingency interim measure (Argonne 2009c) has been approved by the KDHE (2009) and will be implemented if the two operating public water supply wells become contaminated at levels above the RBSL of 5.0 {micro}g/L for carbon tetrachloride. This current report presents the results of monitoring conducted in 2010. Sampling of the monitoring well network was conducted in March-April 2010 and September 2010. In addition, the two operating public water supply wells were sampled in June 2010 and December 2010. On the basis of an evaluation of the data collected in 2006-2009 (Argonne 2010), including a trend analysis of the site contamination and its migration, the KDHE (2010) concurred that future monitoring will occur on an annual basis, with twice-yearly sampling of the two public water supply wells in service (conducted in cooperation with the city). The KDHE (2010) also agreed to decrease the number wells to be sampled in the future, as discussed in Section 5.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗

Established Regulatory Limits for Surface Water and Groundwater

The regulatory limits for surface water and groundwater contained in this database comprise chemical-specific preliminary remediation goals (PRGs) based on potential Applicable or Relevant and Appropriate Requirements (ARARs). These values should be used in conjunction with PRGs based on risk assessment to ensure that the PRGs for a site meet the residual risk requirements for protection of human health and the environment in the National Oil and Hazardous Substance Pollution Contingency Plan (NCP). In some cases, the values presented in this database may be To-Be-Considered (TBC) Guidance because these values are superseded by site-specific state requirements. ARARs are available for the Federal government, California, Georgia, Illinois, Kentucky, New Jersey, New Mexico, Nevada, New York, Ohio, South Carolina, Tennessee, Washington, and Wisconsin. The dataset provides maximum contaminant levels for drinking water and water quality criteria for fresh and marine environments based on acute and chronic exposures. Users can select ARAR sources, drinking water standards and water quality standards, individual chemicals, and retrieve results in tabular or spreadsheet formats for analysis. ARARs are derived from authoritative sources, including federal and state government agencies. The dataset supports environmental risk assessments, regulatory decision-making, and environmental planning, with tools for benchmarking against promulgated standards. This structured approach ensures a robust evaluation of environmental risks tailored to regulatory needs.

Stewart, Debra [Oak Ridge National Laboratory (ORN↗

Grain2Mesh: Mesh Generation for Grain-Scale Nonlinear Elasticity Modeling

The nonlinear hysteretic behavior of rocks under cyclic loading is a crucial area of study in geomechanics. The macroscopic response of a variety of materials has been found to be contingent upon the behavior of the micro-scale structure. This project aims to develop a functional and maintainable software package for generating a multi-phase numerical mesh and accompanying simulation files for finite element modeling used in computational mechanics solvers. Meshes generated from images often lack key preprocessing that reduces noise and prevents mesh element distortion that can increase computational cost. By incorporating user feedback throughout, grain2mesh ensures a high-fidelity mesh that can be used to model grain-scale interactions such as shearing, crack propagation, and interfacial material contrast. Scientific applications of this software include material fracturing, stress-strain analysis for natural and engineered materials, and nonlinear meso-scale analysis.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the Effectiveness of Soil Profile Rehabilitation for Pluvial Flood Mitigation Through Two-Dimensional Hydrodynamic Modeling

Pluvial flooding, driven by increasingly impervious surfaces and intense storm events, presents a growing challenge for urban areas worldwide. In Baltimore City, MD, USA, climate change, rapid urbanization, and aging stormwater infrastructure are exacerbating flooding impacts, resulting in significant socio-economic consequences. This study evaluated the effectiveness of a soil profile rehabilitation scenario using a 2D hydrodynamic modeling approach for the Tiffany Run watershed, Baltimore City. This study utilized different extreme storm events, a high-resolution (1 m) LiDAR Digital Terrain Model (DTM), building footprints, and hydrological soil data. These datasets were integrated into a fully coupled 2D hydrodynamic model, the City Catchment Analysis Tool (CityCAT), to simulate urban flood dynamics. The pre-soil rehabilitation simulation revealed a maximum water depth of 3.00 m in most areas, with hydrologic soil groups C and D, especially downstream of the study area. The post-soil rehabilitation simulation was targeted at vacant lots and public parcels, accounting for 33.20% of the total area of the watershed. This resulted in a reduced water depth of 2.50 m. Additionally, the baseline runoff coefficient of 0.49 decreased to 0.47 following the rehabilitation, and the model consistently recorded a peak runoff reduction rate of 4.10 across varying rainfall intensities. The validation using a contingency matrix demonstrated true-positive rates of 0.75, 0.50, 0.64, and 0 for the selected events, confirming the model’s capability at capturing real-world flood occurrences.

Baltimore City↗

Trial Implementation of a Multihazard Risk Assessment Framework for High-Impact Low-Frequency Power Grid Events

The Pacific Northwest National Laboratory developed a risk framework for modeling high-impact, low-frequency power grid events to support risk-informed decisions. In this research article, we briefly recap the framework and demonstrate its implementation for seismic and geomagnetic hazards using a benchmark reliability test system. We describe integration of a collection of models implemented to perform hazard analysis, fragility evaluation, consequence estimation and post-event restoration. We demonstrate the value of the framework as a multi-hazard power grid risk assessment and management tool. The research will benefit transmission planners and emergency planners by improving their ability to maintain a resilient grid infrastructure against impacts from major events.

power grid, risk assessment, seismic hazard, dynam↗