Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Comparison of Oxygen Liquefaction Gaseous Oxygen Injection via Ullage and Dip Tube

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing demonstrated constant and transient oxygen liquefaction in a scaled lander tank integrated with an industrial cryocooler. Early in the test series, two methods for injecting gaseous oxygen into the test tank were ran under similar constant liquefaction conditions for comparison. Gaseous oxygen was either injected directly from the lid into the ullage or bubbled up through the liquid using a dip tube that extends to the bottom of the test tank. The direct comparison of these gaseous oxygen injection methods for constant liquefaction indicated ullage injection provided a greater liquefaction rate than injection via a dip tube. Injection through the ullage was subsequently selected as the nominal injection method for the CryoFILL test series. The comparison of the two injection methods will be highlighted with a discussion of what may cause the variation in liquefaction rate.

Cryogenic Fluid Management↗

Comparison of OVERFLOW Computational and Experimental Results of the CobraMRV Mars Entry Vehicle Concept during Supersonic Retropropulsion

The CFD solver Overflow was used to simulate the CobraMRV undergoing supersonic retropropulsion (SRP) in the Langley Unitary Plan Wind Tunnel as part of a CFD and wind tunnel integration effort. Selection of numerical methods and resulting comparisons to selected tunnel conditions of interest are detailed. Comparisons of mean pressures with static taps and pressure-sensitive paint are provided for multiple SST-based turbulence models. URANS predicitons of heat shield pressures at high thrust conditions are poor compared to TMRC and DES predictions. Comparisons to experimental measurements of pressure fluctuations indicate complex relationships between heat shield unsteadiness, flight Mach number, and engine thrust coefficient. Bow shock topology and shock cell structure between experimental and OVERFLOW data show good agreement in Schlieren imaging. Recommendations for future investigation into flow field unsteadiness and turbulence models are suggested.

CFD↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept during Supersonic Retropropulsion

Simulations of unsteady supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the OVERFLOW Computational Fluid Dynamics (CFD) solver. High-fidelity flow solver techniques, including Detached Eddy Simulation (DES) turbulence modeling and Adaptive Mesh Refinement (AMR), were employed to obtain improved realism in CFD predictions. Simulation conditions and geometry configurations were designed to match specific runs in the Descent System Study (DSS) wind tunnel testing (WTT) campaign. The accuracy of each simulation is assessed by direct comparison to experimental data. Comparisons of computational predictions of the SRP flowfield and bow shock shape to experimental schlieren imaging show reasonable prediction of mean shock shape, with approximately 10% similarity in shock standoff distance for selected conditions, as well as similarity in local, time-varying fluctuations of the shock-plume interaction. Comparisons of discrete measurements of surface pressure coefficient (Cp) indicate CFD accuracy within approximately 10% of the experiment across the majority of the model heatshield, with larger variations at some of the heatshield edge locations with stronger flow unsteadiness. Simulated unsteadiness of these chaotic flows, which were highly dynamic and multi-modal, was shown to be within 20-40% of experimentally-measured pressure standard deviation (SD) for the majority of the sampled locations.

Supersonic Retropropulsion↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept during Supersonic Retropropulsion

Simulations of unsteady supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the OVERFLOW Computational Fluid Dynamics (CFD) solver. High-fidelity flow solver techniques, including Detached Eddy Simulation (DES) turbulence modeling and Adaptive Mesh Refinement (AMR), were employed to obtain improved realism in CFD predictions. Simulation conditions and geometry configurations were designed to match specific runs in the Descent System Study (DSS) wind tunnel testing (WTT) campaign. The accuracy of each simulation is assessed by direct comparison to experimental data. Comparisons of computational predictions of the SRP flowfield and bow shock shape to experimental schlieren imaging show reasonable prediction of mean shock shape, with approximately 10% similarity in shock standoff distance for selected conditions, as well as similarity in local, time-varying fluctuations of the shock-plume interaction. Comparisons of discrete measurements of surface pressure coefficient (Cp) indicate CFD accuracy within approximately 10% of the experiment across the majority of the model heatshield, with larger variations at some of the heatshield edge locations with stronger flow unsteadiness. Simulated unsteadiness of these chaotic flows, which were highly dynamic and multi-modal, was shown to be within 20-40% of experimentally-measured pressure standard deviation (SD) for the majority of the sampled locations.

Supersonic Retropropulsion↗

Equivalent System Mass Comparison of ECLSS CO2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO2 Scrubber (4BCO2), CO2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO2 technologies best suited for a specific vehicle or mission.

Madeleine C Oliver↗

Equivalent System Mass Comparison of ECLSS CO 2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO 2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO 2 Scrubber (4BCO2), CO 2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO 2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO 2 technologies best suited for a specific vehicle or mission.

Madeleine Oliver↗

Comparison between PARFUME and Bison Using the AGR-2 Irradiation Experiment

This report documents comparisons between Fuel Model (PARFUME) model predictions versus Bison for selected compacts from the second irradiation test of the Advanced Gas Reactor (AGR) program that occurred from June 2010 to October 2013 in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). PARFUME is a fuel performance analysis and modeling code, used for evaluating gas-reactor tristructural isotropic (TRISO) coated particle fuel for prismatic, pebble bed, plate, and cylindrical type fuel geometries. PARFUME is an integrated mechanistic computer code that evaluates the thermal, mechanical, and physico-chemical behavior of TRISO coated-fuel particles and the probability for fuel failure given the particle-to-particle statistical variations in physical dimensions and material properties that arise during the fuel fabrication process. Bison is a nuclear fuel performance application built using the Multiphysics Object-Oriented Simulation Environment (MOOSE) finite element library (Permann 2020). Bison is capable of modeling multiple fuel forms in a wide variety of dimensions and geometries. It solves coupled nonlinear partial differential equations, including heat conduction, mechanics, fission product species transport etc., in a fully implicit manner. Comparisons between PARFUME and Bison were performed using four compacts from the AGR-2 experiment. Selected outputs were chosen based on their impact on the probability of the SiC layer failing. In general there was good agreement between PARFUME and Bison with the exception of predicting the gap formed between the buffer and IPyC. Further comparisons between PARFUME and Bison are planned to further develop Bison’s capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summarizing experimental sensitivities of collider experiments to dark matter models and comparison to other experiments

Comparisons of the coverage of current and proposed dark matter searches can help us to understand the context in which a discovery of particle dark matter would be made. In some scenarios, a discovery could be reinforced by information from multiple, complementary types of experiments; in others, only one experiment would see a signal, giving only a partial, more ambiguous picture; in still others, no experiment would be sensitive and new approaches would be needed. In this whitepaper, we present an update to a similar study performed for the European Strategy Briefing Book performed within the dark matter at the Energy Frontier (EF10) Snowmass Topical Group We take as a starting point a set of projections for future collider facilities and a method of graphical comparisons routinely performed for LHC DM searches using simplified models recommended by the LHC Dark Matter Working Group and also used for the BSM and dark matter chapters of the European Strategy Briefing Book. These comparisons can also serve as launching point for cross-frontier discussions about dark matter complementarity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Comparison of Homogeneous and Heterogeneous Uranium Metal-Water Systems using Calculated and Experimental Critical Data

Heterogeneous effects of fissile units latticed in water has been documented in several forms in commonly referenced handbooks and guides. Many of these documents provide guidance for when heterogeneous systems are more reactive than their homogenous counterparts if controlling fissile mass or volume. This information provides insight into when heterogeneity should be considered for conservatism, however this information is not always displayed in a manner that is comparable to commonly referenced data, such as critical curves based on spherical systems. This paper aims to provide a juxtaposition of homogenous and heterogeneous uranium metal-water systems using both experimental and calculated critical data displayed in the format of commonly referenced critical curves. This format allows for easy comparison between the two systems against parameters that are often considered for single unit analysis such as: uranium density, fissile mass, system volume, and total system mass (fissile mass plus moderator mass). Calculated critical spherical systems provide an equal comparison between latticed geometry types as the latticed array can be cut off or restricted in the same manner in each series of models, which is not true for experimental values. Additionally, enrichment of the latticed units can be made uniform in the calculated systems, which is also difficult to achieve when referencing experimental data of varying latticed geometries. A comparison of calculated critical values and available experimental values is provided to show how these parameters can impact the critical spherical system result.

36 MATERIALS SCIENCE↗

A Comparison of Homogeneous and Heterogeneous Uranium Metal-Water Systems using Calculated and Experimental Critical Data

Heterogeneous effects of fissile units latticed in water has been documented in several forms in commonly referenced handbooks and guides. Many of these documents provide guidance for when heterogeneous systems are more reactive than their homogenous counterparts if controlling fissile mass or volume. This information provides insight into when heterogeneity should be considered for conservatism, however this information is not always displayed in a manner that is comparable to commonly referenced data, such as critical curves based on spherical systems. This paper aims to provide a juxtaposition of homogenous and heterogeneous uranium metal-water systems using both experimental and calculated critical data displayed in the format of commonly referenced critical curves. This format allows for easy comparison between the two systems against parameters that are often considered for single unit analysis such as: uranium density, fissile mass, system volume, and total system mass (fissile mass plus moderator mass). Calculated critical spherical systems provide an equal comparison between latticed geometry types as the latticed array can be physically cut off or restricted in the same manner in each series of models, which is not true for experimental values. Additionally, enrichment of the latticed units can be made uniform in the calculated systems, which is difficult to achieve when referencing experimental data of varying latticed geometries. A comparison of calculated critical values and available experimental values is provided to show how these parameters can impact the critical spherical system result.

36 MATERIALS SCIENCE↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) selected as application models: IEU-MET- FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP- THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET- FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Side-by-Side Comparison of Subhourly Clipping Models: Preprint

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to inter-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of said approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating two different clipping correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons will be performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The models can improve accuracy up to 3% in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

clipping↗

Comparison of Gas Phase Fragmentation Behaviors of Nuclear Fuel Cycle Ligands in Lanthanide and Americium Metal Ligand Nitrate Clusters

Introduction (120 words): Transport of metal ions across the aqueous-organic phase boundary is an essential step in a hydrometallurgical nuclear fuel reprocessing strategy. The study of transport agents for nuclear fuel elements is imperative to guide the design of ligands that boost the separation efficiency of the recovery process from fission products. However, limited studies have been made on the chemistry of these transport agents when complexing with transuranic elements in gas-phase where all surrounding factors are essentially excluded. This work investigates the reagent ligand complexations to transuranic and other metals and their dissociations in the gas phase. Comparisons are made between 4f and 5f elements and between ligands. Methods (120 words): (N,N-diisobutylcarbamoylmethyl)phenyloctylphosphine oxide (CMPO) and N,N,N',N'-tetraoctyldiglycolamide (TODGA) have been selected to complex with metal nitrates. The actinide americium and lanthanides neodymium, samarium, and europium were investigated as part of this work. The lanthanides were selected to act as size and electron configuration analogues of the minor actinides. Metal complexes with two ligands and two nitrates ([M(NO3)2(CMPO)2]+, for example) are studied in Bruker micrOTOF-Q II mass spectrometer equipped with collision-induced dissociation capability. The comparisons of the mass spectra are made in groups of homogenous ligands and mixed TODGA-CMPO ligands clusters. Comparisons are also made based on the complexed metals (Am and lanthanides). Preliminary data (300 words): Collision-induced dissociation mass spectrometry data are collected on two ligands complexed with metal nitrates where the two ligands are homogenous, with (CMPO)2 or (TODGA)2, or heterogeneous, with (TODGA)(CMPO). Several fragmentation patterns are observed among complexes with the CMPO ligand whereas the TODGA ligand commonly dissociates intact from the complex. Most of the metal complexes exhibit similar fragmentation patterns, but there are a few notable deviations in fragmentation patterns between the Am and Ln-bearing complexes. For the [M(CMPO)2(NO3)2]+ complexes, the initial loss of nitrate in the form of nitric acid is observed in all four complexes. However, [Am(CMPO)2(NO3)2]+ exhibits an additional fragmentation not found in the lanthanide complexes. Also, a significantly different ratio of the second nitric acid loss is found in the Am complex. These deviations may indicate the different interaction behaviors between actinides and lanthanides. The [M(TODGA)2(NO3)2]+ complexes exhibit the fragmentation as the loss of one TODGA ligand as an intact form and the loss of nitrate as nitric acid. The Am complex exhibits an additional fragmentation after losing the TOGDA ligand, which is not observed among the Ln complexes. The heterogeneous [M(TODGA)(CMPO)(NO3)2]+ complexes exhibit both similarities and differences between the Am and Ln complexes. For example, the heterogenous Am complex does not exhibit the loss of an intact TODGA ligand while all three Ln complexes do. This indicates that TODGA may bind more strongly to Am than Ln. Additionally, the intensity of the loss of CMPO ligand (as partially or whole) is found to be significantly larger than that of the loss of TODGA (as partially of whole) indicating that TODGA is bound to the metal significantly stronger than CMPO. Planned computational analysis will help understand the deviation in fragmentation behaviors between americium and lanthanide metal centers, or between TODGA and CMPO ligands. Novel aspect (20 words): Gas-phase actinide and lanthanide complex formation and fragmentation provide insight into the coordination environment differences of f-element metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Second-order wave excitation forces in WEC-Sim/MOST: Implementation, experimental validation, and code-to-code comparison

Accurate prediction of second-order hydrodynamic loads is essential for floating bodies, including floating offshore wind turbines, wave energy converters, and hybrid wind–wave platforms. These nonlinear effects, arising from both sum- and difference-frequency forcing, are critical for capturing key response characteristics but remain challenging to model efficiently. In this work, we extend the open-source Wave Energy Converter Simulator / MATLAB for Offshore Simulation Tool by implementing second-order wave excitation forces, supporting both the full Quadratic Transfer Function formulation and the Newman approximation. The full Quadratic Transfer Function method is used for all code-to-code comparisons and experimental validation, while the Newman approximation is provided as a computationally lighter alternative. To benchmark the new capability, we perform a code-to-code comparison with OpenFAST and OrcaFlex. We then validate the enhanced model using wave-tank measurements of a 1:96 scale DeepCwind semi-submersible, showing that second-order effects are required to reproduce platform motions. The implementation employs a computationally efficient pre-computation strategy for second-order wave excitation forces, reducing simulation cost while maintaining engineering accuracy. Overall, this work advances the tool as an open-source and versatile tool for modelling floating offshore renewable-energy systems requiring second-order hydrodynamic fidelity.

17 WIND ENERGY↗

Aeroelastic code comparison using the IEA 22MW reference turbine

Reference wind turbine designs and the associated aeroelastic models are widely used in both research and industry. Reference models representing future concepts are of particular interest. Current state of the art aeroelastic tools are relied upon to design the next generation of large wind turbines. However, modelling assumptions may be invalidated by upcoming very large turbines, and different aeroelastic tools may give inconsistent results. A 22MW turbine model has been defined as part of International Energy Agency (IEA) Wind Task 55 on Reference Wind Turbines and Farms to represent future turbines to be deployed in the 2030s. In this study, an aeroelastic model of this turbine has been created in four tools; Bladed, HAWC2, OpenFAST, and QBlade. Code comparisons are presented for steady state operation, linear stability analysis, and time domain power production simulations in steady and turbulent wind. Generally, the codes show a good agreement, but with some differences present in the linear stability analysis, periodic azimuthal variation, and time domain simulations. The models are a good basis for further study with the IEA 22MW turbine, and further code comparison exercises.

17 WIND ENERGY↗

Review of the 1st EUV Light Sources Code Comparison Workshop

We review the results of the 1 st Extreme Ultraviolet (EUV) Light Sources Code Comparison Workshop. The goal of this workshop was to provide a platform for specialists in EUV light source plasma modeling to benchmark and validate their numerical codes using well-defined case studies. Detailed consideration of a plethora of atomic collisional and radiative processes is required for modeling EUV light source plasmas. Eight institutions spanning four countries contributed data to the workshop. Two topics were addressed, namely (i) the atomic kinetics and radiative properties of tin plasmas under EUV-generating conditions and (ii) laser absorption in a fully ionized, one-dimensional hydrogen plasma. In this paper, we summarize the key findings of the workshop and outline plans for future iterations of the code comparison activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗