Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

BOUT++ nonlinear simulation for a comparative study with the measured 2D ELM structures in the KSTAR H-mode plasma

Here, time-dependent nonlinear simulation using the BOUT++ 3-field model is performed for a study of edge localized mode (ELM) dynamics in KSTAR H-mode plasmas. The simulated results of the ELM evolution are directly compared with the 2D ELM structures, measured by electron cyclotron emission imaging systems, from the initial growth to crash phase. The simulation results are qualitatively in good agreement with the observations. Specifically, it is notable in simulation and experiment that higher-n modes in a quasi-steady state phase evolve into lower-n modes close to the ELM-crash in time. It indicates that lower-n modes may be responsible for the onset of the crash. A postanalysis confirms that nonlinear mode coupling between toroidal harmonics may drive the lower-n mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Amplifier Output Power, Gain, Efficiency, and Bandwidth: A Comparative Study of GaN HEMT MMIC Multi-Stage Power Amplifiers versus Distributed Power Amplifiers

In this paper we present first, the results of a study conducted to investigate the microwave performance of a wideband (25-31 GHz) GaN MMIC distributed high power amplifier (HPA). Second, we compare and contrast the above performance with that of an alternate architecture that relies on two HPAs to provide contiguous 25-31 GHz coverage. The two HPAs operate across 25-28 GHz and 27-31 GHz, respectively, and can be switched in and out depending on the need at any given time. The parameters investigated includes the output power, gain, power added efficiency, bandwidth, RMS error vector magnitude for offset-QPSK, 8PSK, 16APSK, and 32 APSK waveforms, 3rd-order intermodulation distortion products, noise figure, and single sideband phase noise.

MMIC↗

Photocatalytic Degradation of the Nanocomposite Film Comprising Polyvinyl Chloride (PVC) and Sonochemically Synthesized Iron-Doped Zinc Oxide: A Comparative Study of Performances Between Sunlight and UV Radiation

Photocatalytic degradation of a composite film made of PVC and Fe-doped ZnO nanoparticles under both UV and sunlight have been accomplished and compared. The metal-doped semiconductor nanoparticles were previously synthesized using ultrasound. The nanoparticles had average crystal size of 33.67 nm and a bandgap of 2.69 eV. Catalysts loading were varied. Composite film with 0.033 g Fe-ZnO per g PVC was found to be the optimum with respect to degradation and mechanical properties. Degradation was monitored by loss in weight. Under sunlight 12% degradation could be achieved with the composite film in 210 min whereas under UV light the degradation was 10%. For pure PVC film, the corresponding degradations were 4.2 and 4.84% respectively. A plausible mechanism has been suggested and validated with experimental results which fitted the proposed model satisfactorily.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A comparative study of optimum and suboptimum direct-detection laser ranging receivers

A summary of previously proposed receiver strategies for direct-detection laser ranging receivers is presented. Computer simulations are used to compare performance of candidate implementation strategies in the 1- to 100-photoelectron region. Under the condition of no background radiation, the maximum-likelihood and minimum mean-square error estimators were found to give the same performance for both bell-shaped and rectangular optical-pulse shapes. For signal energies greater than 100 photoelectrons, the root-mean-square range error is shown to decrease as Q to the -1/2 power for bell-shaped pulses and Q to the -1 power for rectangular pulses, where Q represents the average pulse energy. Of several receiver implementations presented, the matched-filter peak detector was found to be preferable. A similar configuration, using a constant-fraction discriminator, exhibited a signal-level dependent time bias.

Abshire, J. B.↗

Comparative studies of aerosol extinction measurements made by the SAM II and SAGE II satellite experiments

Results from the Stratospheric Aerosol Measurement (SAM) II and Stratospheric Aerosol and Gas Experiment (SAGE) II are compared for measurement locations which are coincident in time and space. At 1.0 micron, the SAM II and SAGE II aerosol extinction profiles are similar within their measurement errors. In addition, sunrise and sunset aerosol extinction data at four different wavelengths are compared for occasions when the SAGE II and SAM II measurements are nearly coincident in space and about 12 hours apart.

Yue, Glenn K.↗

Phosphides or nitrides for better NLO properties? A detailed comparative study of alkali metal doped nano-cages

Highlights: • Alkali metal doped boron and aluminum phosphide nano-cages are evaluated for NLO properties. • The NLO response of phosphide nano-cages is compared with nitride nano-cages. • Phosphide nano-cages show better NLO properties than the corresponding nitride nano-cages. • Conductivity of doped nano-cages is much higher than pristine nano-cages. • MAl{sub 11}P{sub 12} and MB{sub 11}P{sub 12} show monotonic increase in hyperpolarizability with size of alkali metal. - Abstract: Phosphide nano-cages of MX{sub 12}P{sub 11} and MX{sub 11}P{sub 12} (where X = B or Al, M = Li, Na, K) are investigated theoretically for geometric, electronic and nonlinear optical (NLO) properties. Alkali metal is doped by replacing (a) aluminum or boron atom and (b) phosphorus atom. Alkali metal doping can remarkably alter the electronic and NLO properties of the nano-cages, regardless of doping site. HOMO-LUMO gap is decreased whereas first hyperpolarizability is enhanced significantly in doped AlP and BP nano-cages. PDOS (partial density of states) analysis suggests that diffuse excess electrons from alkali metal play important role in boosting NLO properties of phosphide nano-cages. TD-DFT calculations are performed to study the effect of alkali metal doping on absorption spectra. Red shift is observed in the UV–vis spectra of all considered nano-cages. Comparison of phosphide nano-cages with nitride nano-cages indicated that doping nitride nano-cages with alkali metal leads to greater hyperpolarizability and NLO response than doping phosphide nano-cages.

36 MATERIALS SCIENCE↗

Conduction Heat Transfer through Solid in Porous Materials: A Comparative Study by Finite-Element Simulations and Effective Medium Approximations

The development of insulation materials with low effective thermal conductivity is essential for energy savings in various applications, including buildings, food services, pipe insulation, and refrigeration. Such materials can be developed by using micro- or nanoporous structures, as well as low-thermal conductivity gases and/or reduced pressure. A variety of effective medium approximation (EMA) models have been developed to study thermal transport through solid in porous structures. However, in many cases, the impacts of porosity on solid conduction are not well predicted by EMA models because of the assumptions made for simplification. Furthermore, the results can vary by a factor of up to 1.5, depending on the morphology of the pores. Hence, proper guidance is needed to choose the appropriate EMA model for a given morphology. This work presents a finite element method study using COMSOL Multiphysics software for various geometries, including hollow cubes, overlapping hollow spheres (normally stacked and tightly packed), and Voronoi structures, and compares the results to those obtained from various EMA models. Simulation results for the hollow cubes and Voronoi structures matched well with the Maxwell-Eucken and Russell model. The results for hollow spheres closely matched the Bauer model and the Glicksman model with fitting parameters. This work provides guidance on analyzing and designing insulation materials for energy savings in the future.

36 MATERIALS SCIENCE↗

Six Machine-Learning Methods for Predicting Hospital-Stay Duration for Patients with Sepsis: A Comparative Study

Sepsis is a life-threatening medical condition that, if not treated promptly, can result in tissue damage, organ failure, and death. According to the Centers for Disease Control, about 270,000 individuals die of sepsis in the US each year. Further, sepsis expenditures accounted for 13% of total US hospital costs in 2013, totaling more than $24 billion. Our project objectives were to determine if Machine Learning algorithms could reliably predict hospital stay duration for patients with sepsis. The data set we used has been de-identified and is freely available through the BupaR package. The data includes 1050 cases, 15214 events, and 16 types of actions related to sepsis patient care. First, we used process mining to determine how long each patient was in the hospital. Using BupaR’s functions, we created several process model graphs. These process models depict the movement of patients at a hospital and provide duration data for each patent case. Second, we identified outlier data and created two dataset versions: one with and one without outliers. We then applied the following analysis methods: Linear Regression, Random Forest, K-Nearest Neighbors, Neural Networks, XGBoost, and lightGBM. We compared the model validations for the six machine learning models using the same data-splitting method. We found that the XGBoost model had the best prediction accuracy of 73.9 percent for cases with outliers, and 79 percent for cases without outliers. We also found that the lightGBM model had the lowest mean absolute error between prediction and actual duration in days with 3.66 days for the case with outliers, and 2.4 days for the case without outliers. These two models outperformed the other four models. This work will be enhanced in the future by exploring new prediction algorithms and comparing them with the results of this study.

Chen, Lingtao↗

A comparative study on the physicochemical characteristics of nanoparticles released in vivo from CoCrMo tapers and cement–stem interfaces of total hip replacements

The good biocompatibility and corrosion resistance of the bulk CoCrMo alloy has resulted in it being used in the manufacture of implants and load bearing medical devices. These devices, however, can release wear and corrosion products which differ from the composition of the bulk CoCrMo alloy. The physicochemical characteristics of the particles and the associated in vivo reactivity are dictated by the wear mechanisms and electrochemical conditions at the sites of material loss. Debris released from CoCrMo hip bearings, taper junctions, or cement–stem interfaces can, therefore, have different chemical and morphological characteristics, which provide them with different in vivo toxicities. Here, we propose to assess and compare the characteristics of the particles released in vivo from CoCrMo tapers and cement–stem interfaces which have received less attention compared to debris originating from the hip bearings. The study uses state–of–art characterization techniques to provide a detailed understanding of the size, morphology, composition, and chemistry of the particles liberated from the wear and corrosion flakes from revised hip replacements, with an enzymatic treatment. The phase analyses identified Cr 2 O 3 nanoparticles released from tapers and cement–stem interfaces, whose composition did not vary with origin or particle morphology. The size distributions showed significantly smaller particles were released from the stems, compared to the particles originating from the corresponding tapers. Furthermore, the investigation demonstrates that the tribocorrosive processes occurring at the taper and stem interfaces both result in Cr 2 O 3 nanoparticle formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Life Cycle Analysis of Extruded Films Based on Poly(lactic acid)/Cellulose Nanocrystal/Limonene: A Comparative Study with ATBC Plasticized PLA/OMMT Systems

Life cycle analysis (LCA) of limonene plasticized poly(lactic acid) (PLA) films containing cellulose nanocrystals (CNC) extracted, by acid hydrolysis, from Phormium tenax leaf fibres, was assessed and compared with the results of acetyl tributyl citrate (ATBC) plasticized PLA films, having equivalent mechanical properties, containing organo-modified montmorillonite (OMMT). Eco-Indicator 99 tool has been adopted as the main method for life cycle assessment. Results indicated that, despite CNC are biobased fillers obtained by natural sources, the related chemical extraction leads to a large environmental footprint and a relatively relevant energy expense. LCA characterization of these films demonstrated that the environmental impact of PLA/limonene film reinforced with 1% in weight of CNC (PLA/CNC/limonene) is comparable to the environmental impact of polylactic acid films reinforced with OMMT and plasticized with a petroleum based plasticizer (ATBC) (PLA/OMTT/ATBC). A “cradle to gate” approach has been considered for both the film typologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimation of retired mobile phones generation in China: A comparative study on methodology

Highlights: • The sales data of mobile phones in China was revised by considering the amount of smuggled and counterfeit mobile phones. • The estimation of retired mobile phones in China was made by comparing some relevant methods. • The advanced result of estimation can help improve the policy-making. • The method suggested in this paper can be also used in other countries. • Some discussions on methodology are also conducted in order for the improvement. - Abstract: Due to the rapid development of economy and technology, China has the biggest production and possession of mobile phones around the world. In general, mobile phones have relatively short life time because the majority of users replace their mobile phones frequently. Retired mobile phones represent the most valuable electrical and electronic equipment (EEE) in the main waste stream because of such characteristics as large quantity, high reuse/recovery value and fast replacement frequency. Consequently, the huge amount of retired mobile phones in China calls for a sustainable management system. The generation estimation can provide fundamental information to construct the sustainable management system of retired mobile phones and other waste electrical and electronic equipment (WEEE). However, the reliable estimation result is difficult to get and verify. The priority aim of this paper is to provide proper estimation approach for the generation of retired mobile phones in China, by comparing some relevant methods. The results show that the sales and new method is in the highest priority in estimation of the retired mobile phones. The result of sales and new method shows that there are 47.92 million mobile phones retired in 2002, and it reached to 739.98 million in China in 2012. It presents an increasing tendency with some fluctuations clearly. Furthermore, some discussions on methodology, such as the selection of improper approach and error in the input data, are also conducted in order to improve generation estimation of retired mobile phones and other WEEE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Perpendicular exchange bias behaviors of CoPt/IrMn and CoPt/FeMn bilayers: A comparative study

In this study, FeMn was introduced as an antiferromagnetic (AFM) layer to couple with a single-layered Co{sub 49}Pt{sub 51} alloy thin film, and it was compared with a Co{sub 49}Pt{sub 51}/IrMn bilayer system in exchange bias (EB) effect, to explore the mechanism of spontaneous perpendicular exchange bias (PEB), which has been recently observed in CoPt/IrMn bilayers. Bilayers of CoPt/IrMn and CoPt/FeMn were prepared under the same conditions by sputtering at room temperature without any inducing field. Although PEB was observed in as-grown CoPt/FeMn bilayers, the loop shape and PEB behavior were found to exhibit different characteristics from those of CoPt/IrMn bilayers. The CoPt (5 nm)/FeMn (10 nm) bilayer has a sheared loop that is similar to a double-shifted loop and a much lower squareness ratio (SQR = 0.52) and exchange bias field (H{sub e} = 180 Oe) than the CoPt (5 nm)/IrMn (10 nm) system, which has a rectangular loop shape and a high SQR of 0.97 and large H{sub e} of 290 Oe. The two systems present entirely different dependences of PEB on the thickness of the AFM layer. CoPt/IrMn exhibits behavior that is typical of most EB systems, but for CoPt/FeMn, this dependence is more complicated with an unusual peak at an AFM layer thickness of 10 nm. Based on the dissimilar loop shapes and dependences of PEB on AFM thickness, the mechanisms of the spontaneously established PEB in these two systems are considered to differ. Investigations of cross-sectional transmission electron microscopy revealed no apparent difference between the interfacial microstructures of the two systems. X-ray diffraction studies demonstrated the 〈111〉 texture of both systems. Therefore, different interfacial spin configurations may be responsible for the dissimilar PEB behaviors in these two FM/AFM bilayer systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of curing temperature on belite cement hydration: A comparative study with Portland cement

Belite cements (BCs) could be a more sustainable binder than Portland cements (PCs) but adequate knowledge of the hydration features has still to be built. In particular, the mild curing hydration temperature effects have been extensively studied for PCs but not for BCs. This research was triggered by a previous work reporting improved mechanical strengths of BCs at higher curing temperatures. Here, we report the hydration characteristics of a BC at 20, 40 and 60 °C and compared to those of a typical PC. We have corroborated previous findings and used a multi-technique approach including Rietveld phase analysis, thermal analysis, calorimetry, silicon MAS-NMR, mercury intrusion porosimetry and chiefly synchrotron X-ray microtomography, to thoroughly understand the different behavior. In a nutshell, the improved mechanical performances at mild curing temperatures for BCs are mainly due to a much larger belite degree of reaction, with lower porosity coarsening of belite cements also playing a role.

36 MATERIALS SCIENCE↗

A Comparative Study of Automated Infrasound Detectors - PMCC and AFD with Analyst Review.

Automated detections calculated by the progressive multi-channel correlation (PMCC) method (Cansi, 1995) and the adaptive F detector (AFD) (Arrowsmith et al., 2009) are compared to the signals identified by five independent analysts. Each detector was applied to a four-hour time sequence recorded by the Korean infrasound array CHNAR. This array was used because it is composed of both small (<100 m) and large (~1000 m) aperture element spacing. The four hour time sequence contained a number of easily identified signals under noise conditions that have average RMS amplitudes varied from 1.2 to 4.5 mPa (1 to 5 Hz), estimated with running five-minute window. The effectiveness of the detectors was estimated for the small aperture, large aperture, small aperture combined with the large aperture, and full array. The full and combined arrays performed the best for AFD under all noise conditions while the large aperture array had the poorest performance for both detectors. PMCC produced similar results as AFD under the lower noise conditions, but did not produce as dramatic an increase in detections using the full and combined arrays. Both automated detectors and the analysts produced a decrease in detections under the higher noise conditions. Comparing the detection probabilities with Estimated Receiver Operating Characteristic (EROC) curves we found that the smaller value of consistency for PMCC and the larger p-value for AFD had the highest detection probability. These parameters produced greater changes in detection probability than estimates of the false alarm rate. The detection probability was impacted the most by noise level, with low noise (average RMS amplitude of 1.7 mPa) having an average detection probability of ~40% and high noise (average RMS amplitude of 2.9 mPa) average detection probability of ~23%.

58 GEOSCIENCES↗

A comparative study of the Au + H{sub 2}, Au{sup +} + H{sub 2}, and Au{sup −} + H{sub 2} systems: Potential energy surfaces and dynamics of reactive collisions

In order to study the Au{sup −} + H{sub 2} collision, a new global potential energy surface (PES) describing the ground electronic state of AuH{sub 2}{sup −} system is developed and compared with the PESs of the neutral [Zanchet et al., J. Chem. Phys. 132, 034301 (2010)] and cationic systems [Anaís et al., J. Chem. Phys. 135, 091102 (2011)]. We found that Au{sup −} − H{sub 2} presents a H-Au-H insertion minimum attributed to the stabilization of the LUMO 3b{sub 2} orbital, which can be considered as the preamble of the chemisorption well appearing in larger gold clusters. While the LUMO orbital is stabilized, the HOMO 6a{sub 1} is destabilized, creating a barrier at the geometry where the energy orbitals’ curves are crossing. In the anion, this HOMO is doubly occupied, while in the neutral system is half-filled and completely empty in the cation, explaining the gradual disappearance of the well and the barrier as the number of electrons decreases. The cation presents a well in the entrance channel partially explained by electrostatic interactions. The three systems’ reactions are highly endothermic, by 1.66, 2.79, and 3.23 eV for AuH, AuH{sup +}, and AuH{sup −} products, respectively. The reaction dynamics is studied using quasi-classical trajectory method for the three systems. The one corresponding to the anionic system is new in this work. Collision energies between 1.00 and 8.00 eV, measured for the cation, are in good agreement with the simulated cross section for the AuH{sup +}. It was also found that the total fragmentation, in three atoms, competes becoming dominant at sufficiently high energy. Here, we study the competition between the two different reaction pathways for the anionic, cationic, and neutral species, explaining the differences using a simple model based on the topology of the potential energy surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative study on hydrostatic strain, stress and dislocation density of Al{sub 0.3}Ga{sub 0.7}N/GaN heterostructure before and after a-Si{sub 3}N{sub 4} passivation

The hydrostatic strain, stress and dislocation densities were comparatively analyzed before and after passivation of amorphous silicon nitride (a-Si{sub 3}N{sub 4}) layer on Al{sub 0.3}Ga{sub 0.7}N/GaN heterostructure by nondestructive high resolution x-ray diffraction (HRXRD) technique. The crystalline quality, in-plane and out-of plane strain were evaluated from triple-axis (TA) (ω-2θ) diffraction profile across the (002) reflection plane and double-axis (DA) (ω-2θ) glancing incidence (GI) diffraction profile across (105) reflection plane. The hydrostatic strain and stress of Al{sub 0.3}Ga{sub 0.7}N barrier layer were increased significantly after passivation and both are tensile in nature. The dislocation density of GaN was also analyzed and no significant change was observed after passivation of the heterostructure. The crystalline quality was not degraded after passivation on the heterostructure confirmed by the full-width-half-maximum (FWHM) analysis.

36 MATERIALS SCIENCE↗

A comparative study of structural and optical properties of Cu{sub 2}ZnSnS{sub 4} nanocrystals for photovotaic applications

The Cu{sub 2}ZnSnS{sub 4} (CZTS) nanocrystals were successfully synthesized by hot injection method. The synthesized nanocrystals were characterized by the X-ray diffraction (XRD) and UV–visible spectrometer. X-ray diffraction studies reveal polycrystalline films exhibiting kesterite structures with preferential orientation along (112) direction. From UV studies revealed that the CZTS nanocrystals band gap was tuned between 1.6 eV (for 1 hour, stirring) and 1.4 eV (for 2 hours stirrer) and its compared, structural and optical properties of CZTS by density functional theory based on Wien2K (FP-LAPW) simulation employing a combined Tran-Blaha modified Becke-Johnson (TB-MBJ) potential with scissor corrections. From this calculation, it was found that the compound is in direct nature. The estimated lattice constant and bandgap value is in good agreement with earlier reported results. The optical band-gap energy of the CZTS nanocrystals is 1.4 eV, which is quite close to the optimum value for solar cell.

36 MATERIALS SCIENCE↗