Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commonality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Common-Coil Dipole for a Very Large Hadron Collider [Book Chapter]

A dipole magnet based on the common-coil design and pre-reacted Nb$_{3}$Sn cable was developed at the Fermi National Accelerator Laboratory (FNAL) for a Very Large Hadron Collider. Three technological racetrack models and a short dipole model have been fabricated and tested. This chapter summarizes the main results of this program.

43 PARTICLE ACCELERATORS↗

A common origin for the QCD axion and sterile neutrinos from SU(5) strong dynamics

We identify the QCD axion and right-handed (sterile) neutrinos as bound states of an SU(5) chiral gauge theory with Peccei-Quinn (PQ) symmetry arising as a global symmetry of the strong dynamics. The strong dynamics is assumed to spontaneously break the PQ symmetry, producing a high-quality axion and naturally generating Majorana masses for the right-handed neutrinos at the PQ scale. The composite sterile neutrinos can directly couple to the left-handed (active) neutrinos, realizing a standard see-saw mechanism. Alternatively, the sterile neutrinos can couple to the active neutrinos via a naturally small mass mixing with additional elementary states, leading to light sterile neutrino eigenstates. The SU(5) strong dynamics therefore provides a common origin for a high-quality QCD axion and sterile neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transcholecystic Placement of an ePTFE/FEP-Covered Stent in the Common Bile Duct

We report the case of a 78-year-old male patient with obstructive jaundice due to a pancreatic head neoplasm. The patient's general condition did not permit an endoscopic approach and the presence of diffuse liver metastases prohibited hepatic puncture for percutaneous biliary drainage, therefore the transcolecystic transperitoneal approach was decided to be the safest decompression route. Through a gallbladder access, a Viabil-covered stent with a mesh extension was placed in the distal common bile duct, without complications. The patient died 8 months later without signs of stent dysfunction or necessity of reintervention. Transcholecystic transperitoneal access is a safe option when diffuse liver metastases prohibit the transhepatic approach, even in cases where placement of a covered stent is considered necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a-the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Entrapment of the StarClose Vascular Closure System After Attempted Common Femoral Artery Deployment

A complication of the StarClose Vascular Closure System (Abbott, Des Plaines, IL) after a transarterial hepatic chemoembolization is described. After attempted clip deployment, the entire device became lodged in the tissues overlying the common femoral artery and could not be removed percutaneously. Successful removal of the device required surgical cutdown for removal and arterial repair. Entrapment of the StarClose vascular closure deployment system is a potentially serious complication that has been reported in the Manufacturer and User Facility Device Experience database, but has not been recognized in the literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Recanalization of a Longstanding Right Common Iliac Artery Occlusion with a Radiofrequency Guidewire

We describe a case of successful recanalization of a longstanding right common iliac occlusion with a radiofrequency (RF) guidewire. The patient had been symptomatic with claudication for 3 years, and a preliminary attempt to cross the lesion using conventional techniques proved unsuccessful. Using low and medium intensity RF pulses and a PowerWire, a tract through the occlusion was established, which allowed subsequent stenting with an excellent angiographic result and a good immediate clinical response. We propose this as a useful technique in the peripheral arterial system for occlusive lesions not amenable to traditional recanalization techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture and Collapse of Balloon-Expandable Stents in the Bilateral Common Iliac Arteries Due to Shiatsu Massage

We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapse of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Infrarenal Abdominal Aortic Lesions With or Without Common Iliac Artery Involvement

To evaluate the results of stent placement for obstructive atherosclerotic aortic disease with or without involvement of the common iliac artery. Forty patients had self-expanding stents primarily or after balloon dilatation in the abdominal aorta between January 2005 and May 2011. All patients had trouble walking. Follow-up examinations were performed with clinical visits; these included color Doppler ultrasonography and computed tomographic angiography. Technical, clinical, and hemodynamic success was achieved in all patients. None of the patients underwent reintervention during the follow-up period, which ranged from 3 months to 6 years (median 24 months). Nine complications occurred in six patients. Of the nine complications, four were distal thromboembolisms, which were successfully treated with catheter-directed thrombolysis or anticoagulation therapy. Endovascular treatment of the obstructive aortic disease using self-expanding stents was safe and effective, with high technical success and long-term patency. Thromboembolic complications were high even though direct stenting was considered protective for thromboembolism formation. Particularly for infrarenal aortic stenosis, it can be recommended as the first-line treatment option for patients with obstructive atherosclerotic aortic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 {+-} 5 years; range 42-67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4-25) before the procedure to 20 (range 1-25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Center Experience and 1-Year Follow-up Results of 'Sandwich Technique' in the Management of Common Iliac Artery Aneurysms During EVAR

Purpose: Abdominal aortic aneurysm (AAA) accompanied by common iliac artery (CIA) aneurysms requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent-graft limb(s), a potential site of endoleak. The 'sandwich technique' is a procedure to increase EVAR feasibility in the setting of adverse or challenging CIA anatomy. Its main advantages include no restrictions in terms of CIA diameter or length or internal iliac artery (IIA) diameter, no need to wait for a specific stent-graft. Our purpose is to describe our single-center experience and one year follow-up results of this new procedure. Materials and Methods: From April 2009 to June 2010, the sandwich technique was performed in our institution in 7 patients treated for AAA and unilateral CIA aneurysms (n. 5) or bilateral CIA aneurysms (n. 2). Inclusion criteria were the presence of unilateral or bilateral CIA aneurysm (independently from its diameter), IIA artery measuring up to 9 mm in its maximum diameter, not dilatation of IIA and EIA. Results: The mean follow-up length was 15 months (range: 14-20 months). All stent-implanted iliac branches remained patent on 1 year follow-up and IIA flow was preserved. None of the patients had symptoms of pelvic ischemia. CT scan follow-up showed aneurysm shrinkage in five patients, without any sign of endoleaks in all cases. Conclusions: In selected cases, the 'sandwich technique' showed good outcomes confirming to be a safe and easy to perform way to overcome anatomical constraints and expanding the limits of EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Amplatzer Vascular Plug with Preoperative Common Hepatic Artery Embolization for Distal Pancreatectomy with En Bloc Celiac Axis Resection

PurposeTo evaluate the feasibility and safety of the Amplatzer vascular plug (AVP) for preoperative common hepatic embolization (CHA) before distal pancreatectomy with en bloc celiac axis resection (DP-CAR) to redistribute blood flow to the stomach and liver via the superior mesenteric artery (SMA).Materials and MethodsFour patients (3 males, 1 female; median age 69 years) with locally advanced pancreatic body cancer underwent preoperative CHA embolization with AVP. After embolization, SMA arteriography was performed to confirm the alteration of blood flow from the SMA to the proper hepatic artery.ResultsIn three of four patients, technical successes were achieved with sufficient margin from the origin of gastroduodenal artery. In one patient, the margin was less than 5 mm, although surgery was successfully performed without any problem. Eventually, all patients underwent the DP-CAR without arterial reconstruction or liver ischemia.ConclusionsAVP application is feasible and safe as an embolic procedure for preoperative CHA embolization of DP-CAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perioperative Hemodynamic Monitoring of Common Hepatic Artery for Endovascular Embolization of a Pancreaticoduodenal Arcade Aneurysm with Celiac Stenosis

This report describes perioperative hemodynamic monitoring of the common hepatic artery (CHA) during endovascular treatment of a pancreaticoduodenal arcade aneurysm, in a patient with celiac artery stenosis caused by the median arcuate ligament. Pressure monitoring was performed as a safety measure against critical complications such as liver ischemia. As the aneurysm was located in the anterior pancreaticoduodenal artery (APDA) and the posterior pancreaticoduodenal artery (PPDA) was small in caliber, the patient was considered to be at a high risk of liver ischemia. No significant change in pressure was observed in the CHA on balloon occlusion test in the APDA. Immediately after embolization, the PPDA enlarged and the pressure in the CHA was well maintained. Pressure monitoring appears to improve patient safety during endovascular treatment of visceral aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗