Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Operando 3D imaging of defects dynamics of twinned-nanocrystal during catalysis

Using operando Bragg coherent x-ray diffraction imaging, we visualised three-dimensionally a single twinned-gold nanocrystal during the CO oxidation reaction. We describe the defect dynamics process occurring under operating conditions and indicate the correlation between the nucleation of highly strained regions at the surface of the nanocrystal and its catalytic activity. Understanding the twinning deformation mechanism sheds light on the creation of active sites, and could well contribute to the understanding of the catalytic behaviour of other catalysts. Furthermore, with the start-up of 4th generation synchrotron sources, we anticipate that coherent hard x-ray diffraction imaging techniques will play a major role in imaging in situ chemical processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Filtering Image Records Using Wavelets and the Zakai Equation

Consider the problem of detecting and localizing a faint object moving In an "essentially stationary" background, using a sequence of two-dimensional low-SNR images of the scene. A natural approach consists of "digitizing" each snapshot into a discrete set of observations, sufficiently (perhaps not exactly) matched to the object In question, then tracking the object using an appropriate stochastic filter. The tracking would be expected to make up for the low signal-to-noise ratio, this allowing one to "coherently" process successive images in order to beat down the noise and localize the object. Thus, "tracking" here does not refer to the usual notion of detecting then tracking: rather, we track in order to detect The problem then becomes one of choosing the appropriate image representation as well as the optimal (and necessarily nonlinear filter. We propose exact and approximate solutions using wavelets and the Zakai equation. The smoothness of the wavelets used is required in the derivation of the evolution equation for the conditional density giving the filter, and their orthogonality makes it possible to carry out actual computations of the Ito- and change-of-gauge-terms in the algorithm effectively.

Haddad, Ziad S.↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Revealing the three-dimensional structure of microbunched plasma-wakefield-accelerated electron beams

Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high- Z gas-target dopants or by uncontrolled laser–plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators.

43 PARTICLE ACCELERATORS↗

Visual Impairment/lntracranial Pressure Risk Clinical Care Data Tools

Prior to 2010, several ISS crewmembers returned from spaceflight with changes to their vision, ranging from a mild hyperopic shift to frank disc edema. As a result, NASA expanded clinical vision testing to include more comprehensive medical imaging, including Optical Coherence Tomography and 3 Tesla Brain and Orbit MRIs. The Space and Clinical Operations (SCO) Division developed a clinical practice guideline that classified individuals based on their symptoms and diagnoses to facilitate clinical care. For the purposes of clinical surveillance, this classification was applied retrospectively to all crewmembers who had sufficient testing for classification. This classification is also a tool that has been leveraged for researchers to identify potential risk factors. In March 2014, driven in part by a more comprehensive understanding of the imaging data and increased imaging capability on orbit, the SCO Division revised their clinical care guidance to outline in‐flight care and increase post‐flight follow up. The new clinical guidance does not include a classification scheme

Van Baalen, Mary↗

Tracking hurricane paths

The South East coastal region experiences hurricane threat for almost six months in every year. To improve the accuracy of hurricane forecasts, meteorologists would need the storm paths of both the present and the past. A hurricane path can be established if we could identify the correct position of the storm at different times right from its birth to the end. We propose a method based on both spatial and temporal image correlations to locate the position of a storm from satellite images. During the hurricane season, the satellite images of the Atlantic ocean near the equator are examined for the hurricane presence. This is accomplished in two steps. In the first step, only segments with more than a particular value of cloud cover are selected for analysis. Next, we apply image processing algorithms to test the presence of a hurricane eye in the segment. If the eye is found, the coordinate of the eye is recorded along with the time stamp of the segment. If the eye is not found, we examine adjacent segments for the existence of hurricane eye. It is probable that more than one hurricane eye could be found from different segments of the same period. Hence, the above process is repeated till the entire potential area for hurricane birth is exhausted. The subsequent/previous position of each hurricane eye will be searched in the appropriate adjacent segments of the next/previous period to mark the hurricane path. The temporal coherence and spatial coherence of the images are taken into account by our scheme in determining the segments and the associated periods required for analysis.

Prabhakaran, Nagarajan↗

1-D imaging of rotation-vibration non-equilibrium from pure rotational ultrafast coherent anti-Stokes Raman scattering

We present one-dimensional (1-D) imaging of rotation-vibration non-equilibrium measured by two-beam pure rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Simultaneous measurements of the spatial distribution of molecular rotation-vibration non-equilibrium are critical for understanding molecular energy transfer in low temperature plasmas and hypersonic flows. However, non-equilibrium CARS thermometry until now was limited to point measurements. The red shift of rotational energy levels by vibrational excitation was used to determine the rotational and vibrational temperatures from 1-D images of the pure rotational spectrum. Vibrational temperatures up to 5500 K were detected in a CH4/N2 nanosecond-pulsed pin-to-pin plasma within 2 mm near the cathode. As a result, this approach enables study of non-equilibrium systems with 40 µm spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seasat-A - An ocean observation satellite

Mission details, onboard equipment, and measurements to be taken are described for the Seasat-A global ocean monitoring satellite. The satellite is designed for mapping the global ocean geoid, charting ice fields and leads, precision measurement of sea surface topography, global monitoring of wave height and wave directional spectra, surface winds and wind direction, current patterns, and ocean temperature. Data handling subsystems, a compressed pulse radar altimeter, coherent synthetic aperture imaging radar, microwave wind scatterometer, scanning visible/IR radiometer, scanning multispectral (5 freq) microwave radiometer mounted on the satellite are described briefly.

Williams, F. L.↗

Seasat-A oceanographic data system and users

The Seasat-A system is reviewed with emphasis on data retrieval, processing and dissemination plans. Attention is paid to the sensors of the Seasat satellite including the compressed pulse radar altimeter, the coherent synthetic aperture imaging radar, the microwave wind scatterometer, and the scanning visible/infrared radiometer. Particular emphasis is placed on a particular set of experiments: the Navy's Fleet Numerical Weather Control will receive Seasat data in real time and process the data into products that will be used in weather and sea condition forecasts.

Mccandless, S. W., Jr.↗

A coherent, solid state, 225 GHz receiver

A low noise, broadband, balanced mixer has been developed for use as a 225-GHz receiver. It utilizes a local oscillator (LO), whose frequency is nearly 1/4 the signal frequency, to mix the signal power to a low IF, which is then amplified. This same LO drives a similar mixer that is used to phase lock a 225-GHz transmitter. The use of a subharmonic mixer lowers LO cost, noise, and complexity, increases LO availability and reliability, and is compact and portable. Typical applications for this type of mixer include coherent receivers, passive imaging, multiple receiver systems, and broadband detection systems

Forsythe, R. E.↗

Limitations To Optical/IR Interferometry

The primary limitation to ground-based optical/IR interferometry is the turbulent atmosphere, which limits sensitivity by restricting the coherence volume, limits imaging accuracy by corrupting the fringe phase, and limits astrometric acuracy by corrupting the angel of arrival.

Ground-based Optical Interferometry↗

Improved Speed and Functionality of a 580-GHz Imaging Radar

With this high-resolution imaging radar system, coherent illumination in the 576-to-589-GHz range and phase-sensitive detection are implemented in an all-solid-state design based on Schottky diode sensors and sources. By employing the frequency-modulated, continuous-wave (FMCW) radar technique, centimeter-scale range resolution has been achieved while using fractional bandwidths of less than 3 percent. The high operating frequencies also permit centimeter-scale cross-range resolution at several-meter standoff distances without large apertures. Scanning of a single-pixel transceiver enables targets to be rapidly mapped in three dimensions, so that the technology can be applied to the detection of concealed objects on persons.

Dengler, Robert↗

Chlorophyll-a Algorithms for Oligotrophic Oceans: A Novel Approach Based on Three-Band Reflectance Difference

A new empirical algorithm is proposed to estimate surface chlorophyll-a concentrations (Chl) in the global ocean for Chl less than or equal to 0.25 milligrams per cubic meters (approximately 77% of the global ocean area). The algorithm is based on a color index (CI), defined as the difference between remote sensing reflectance (R(sub rs), sr(sup -1) in the green and a reference formed linearly between R(sub rs) in the blue and red. For low Chl waters, in situ data showed a tighter (and therefore better) relationship between CI and Chl than between traditional band-ratios and Chl, which was further validated using global data collected concurrently by ship-borne and SeaWiFS satellite instruments. Model simulations showed that for low Chl waters, compared with the band-ratio algorithm, the CI-based algorithm (CIA) was more tolerant to changes in chlorophyll-specific backscattering coefficient, and performed similarly for different relative contributions of non-phytoplankton absorption. Simulations using existing atmospheric correction approaches further demonstrated that the CIA was much less sensitive than band-ratio algorithms to various errors induced by instrument noise and imperfect atmospheric correction (including sun glint and whitecap corrections). Image and time-series analyses of SeaWiFS and MODIS/Aqua data also showed improved performance in terms of reduced image noise, more coherent spatial and temporal patterns, and consistency between the two sensors. The reduction in noise and other errors is particularly useful to improve the detection of various ocean features such as eddies. Preliminary tests over MERIS and CZCS data indicate that the new approach should be generally applicable to all existing and future ocean color instruments.

Hu, Chuanmin↗

Countermeasures for Mitigation of Sensorimotor Decrements Following Head-Down Tilt Bed Rest

BACKGROUND Astronauts experience postflight disturbances in postural and locomotor control due to sensorimotor adaptations during spaceflight. These alterations may have adverse consequences if a rapid egress is required after landing. Although exercise is partially effective for mitigating cardiovascular and muscular deconditioning, additional countermeasures are needed to further preserve sensorimotor function. Proprioception training and electrical muscle stimulation (EMS) are two promising in-flight countermeasures. Since prolonged head down tilt bed rest (HDTBR) is a spaceflight analog for body unloading and causes postural and locomotor control decrements that parallel those observed after spaceflight, it can be used to facilitate the development of these countermeasures. METHODS This study will determine the effects of proprioception training and EMS on functional task performance and sensorimotor function following 60 days of 6° HDTBR. Subjects will be randomly assigned to one of four groups: 1) an EMS arm, 2) a proprioception training arm, 3) an exercise plus proprioceptive training arm, and 4) a control arm. The EMS countermeasure will include daily bilateral stimulation of selected bilateral lower extremity muscles (30 minutes per session). Proprioception training will be performed three days per week (25 minutes per session) consisting of body-loaded postural tasks in the horizontal position on an air bearing sled. Exercise training will mimic current protocols used on the International Space Station, but treadmill aerobic exercise will be replaced with additional cycling aerobic exercise. Primary outcome measures will include pre- and post- HDTBR functional tests that require high demand for dynamic control of postural stability. Secondary measures will be used to explore key physiological changes that underlie countermeasure benefits. All HDTBR and data collection activities will be completed by the German Aerospace Center (DLR) at the :envihab facility. Given the constrained samples size, a Bayesian modelling approach will be used to quantify the probability that there is an effect of a given magnitude. HARDWARE AND PROTOCOL DEVELOPMENT Final hardware modifications and protocol developments were completed in preparation for Campaign 1, which began in September 2024. These included shipment, setup, and operator training for the transportable gravity bed, horizontal squat device, foam obstacle course, EMS devices, leg dexterity system, foot sole skin sensitivity system, and Radiofrequency Echographic Multi Spectrometry (REMS) ultrasound device. In addition, specialized protocols were developed for data collection using DLR’s equipment, including muscle morphology magnetic resonance imaging (MRI), optical coherence tomography, venous blood flow MRI and ultrasound, muscle ultrasound and impedance, and skin blood flow ultrasound. We will present early data from the first campaign, which concluded in November, 2024. These will be compared with previous data from the recent 30-day HDTBR campaigns (Spaceflight associated neuro-ocular syndrome countermeasures (SANS-CM)) conducted at DLR. RELEVANCE The deliverable from this project will be proof-of-concept sensorimotor countermeasure designs for functional task performance with full assessment of efficacy in a spaceflight analog. If one or more countermeasures are effective, they will be translated for validation with the suite of operationally implemented in-flight countermeasures.

T R Macaulay↗

Sizes of pure and doped helium droplets from single shot x-ray imaging

Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. Furthermore, this imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 10 9 –10 11 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical correlators for automated rendezvous and capture

The paper begins with a description of optical correlation. In this process, the propagation physics of coherent light is used to process images and extract information. The processed image is operated on as an area, rather than as a collection of points. An essentially instantaneous convolution is performed on that image to provide the sensory data. In this process, an image is sensed and encoded onto a coherent wavefront, and the propagation is arranged to create a bright spot of the image to match a model of the desired object. The brightness of the spot provides an indication of the degree of resemblance of the viewed image to the mode, and the location of the bright spot provides pointing information. The process can be utilized for AR&C to achieve the capability to identify objects among known reference types, estimate the object's location and orientation, and interact with the control system. System characteristics (speed, robustness, accuracy, small form factors) are adequate to meet most requirements. The correlator exploits the fact that Bosons and Fermions pass through each other. Since the image source is input as an electronic data set, conventional imagers can be used. In systems where the image is input directly, the correlating element must be at the sensing location.

Juday, Richard D.↗

Characterization of coherent structures in a turbulent mixing layer by digital image analysis

Digital image analysis has been applied to a shadowgraph motion picture of a helium nitrogen mixing layer in order to characterize the coherent vortex structures in the flow. Both the primary spanwise coherent vortices and secondary streamwise vortices are considered. Pattern recognition algorithms were designed to take advantage of the more pronounced features of the vortices and of their temporal coherence to isolate them and to measure their characteristics. The resulting data base permits a deterministic description of the evolution of primary and seconary vortices.

Bernal, L. P.↗

Comparison of several techniques to obtain multiple-look SAR imagery

In order to improve image interpretability when SAR imagery is contaminated by coherent speckle noise, multiple look images are often generated. The performance levels of techniques for the generation of such multiple look imagery are presently assessed, with attention to the detailed impulse responses and signal-to-speckle noise ratios obtainable. The speckle-reduction technique considered are those of the discrete mixed integrator and the image domain filter. It is found that, by using several types of image domain filters, the signal-to-speckle noise ratio can be improved over the conventional discrete mixed integrator method's results while maintaining the equivalent rectangular resolution constant.

Li, F.-K.↗