Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

First-principles thermodynamic theory of Seebeck coefficients

To begin, thermoelectric effects, measured by the Seebeck coefficients, refer to the phenomena in which a temperature difference or gradient imposed across a thermoelectric material induces an electrical potential difference or gradient, and vice versa, enabling the direct conversion of thermal and electric energies. All existing first-principles calculations of Seebeck coefficients have been based on the Boltzmann kinetic transport theory. In this work, we present a fundamentally different method for the first-principles calculations of Seebeck coefficients without using any assumptions of the electron-scattering mechanism, being in contrast to the traditional theory by Cutler and Mott that shows the dependence of the Seebeck coefficient on the scattering mechanisms. It is shown that the Seebeck coefficient is a well-defined thermodynamic quantity that can be determined from the change in the chemical potential of electrons induced by the temperature change and thus can be computed solely based on the electronic density of states through first-principles calculations at different temperatures. The proposed approach is demonstrated using the prototype PbTe and SnSe thermoelectric materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New calculation method of neutron kerma coefficients for carbon and oxygen below 30 MeV

On the basis of the statistical theory of a neutron-induced light nucleus reaction, a new kerma coefficient calculation formula, expressed as k{sub {phi}}=NijkE{sub ijk}(E{sub n}){sigma}{sub ijk}(E{sub n}), is developed in this paper. In an analysis of the n+{sup 12}C and n+{sup 16}O reactions below 30 MeV, the average energies E{sub ijk} of emitted particles of all kinds in the laboratory frame are derived in detail for different channels, allowing an exact energy balance. The optical model parameters of neutron and charged particles, which had reproduced very well the outgoing neutron double-differential cross sections in our early works, are used to obtain the cross sections {sigma}{sub ijk}. The calculated partial, elastic recoil, and total kerma coefficients for carbon and oxygen are consistent with existing experimental kerma coefficient data. The elastic cross sections and the first Legendre coefficients of elastic angular distribution derived from EBDF/B-VIIb3 are used in this paper to improve significantly the elastic recoil and total kerma coefficients.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to {sup 60}Co

Purpose: To investigate the applicability of a wide range of microionization chambers for reference dosimetry measurements in low- and medium-energy x-ray beams. Methods: Measurements were performed with six cylindrical microchamber models, as well as one scanning chamber and two Farmer-type chambers for comparison purposes. Air-kerma calibration coefficients were determined at the University of Wisconsin Accredited Dosimetry Calibration Laboratory for each chamber for a range of low- and medium-energy x-ray beams (20-250 kVp), with effective energies ranging from 11.5 keV to 145 keV, and a {sup 60}Co beam. A low-Z proof-of-concept microchamber was developed and calibrated with and without a high-Z silver epoxy on the collecting electrode. Results: All chambers composed of low-Z materials (Z{<=} 13), including the Farmer-type chambers, the scanning chamber, and the PTW TN31014 and the proof-of-concept microchambers, exhibited air-kerma calibration coefficients with little dependence on the quality of the beam. These chambers typically exhibited variations in calibration coefficients of less than 3% with the beam quality, for medium energy beams. However, variations in air-kerma calibration coefficients of greater than 50% were measured over the range of medium-energy x-ray beams for each of the microchambers containing high-Z collecting electrodes (Z > 13). For these high-Z chambers, which include the Exradin A14SL and A16 chambers, the PTW TN31006 chamber, the IBA CC01 chamber, and the proof-of-concept chamber containing silver, the average variation in air-kerma calibration coefficients between any two calibration beams was nearly 25% over the entire range of beam qualities investigated. Conclusions: Due to the strong energy dependence observed with microchambers containing high-Z components, these chambers may not be suitable dosimeters for kilovoltage x-ray applications, as they do not meet the TG-61 requirements. It is recommended that only microchambers containing low-Z materials (Z{<=} 13) be considered for air-kerma calibrations for reference dosimetry in low- and medium-energy x-ray beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-18C-05: Evaluation of a Method to Calculate Patient-Oriented MGD Coefficients Using Estimates of Glandular Tissue Distribution

Purpose: Evaluate mammographic mean glandular dose (MGD) coefficients for particular known tissue distributions using a novel formalism that incorporates the effect of the heterogeneous glandular tissue distribution, by comparing them with MGD coefficients derived from the corresponding anthropomorphic computer breast phantom. Methods: MGD coefficients were obtained using MCNP5 simulations with the currently used homogeneous assumption and the heterogeneously-layered breast (HLB) geometry and compared against those from the computer phantom (ground truth). The tissue distribution for the HLB geometry was estimated using glandularity map image pairs corrected for the presence of non-glandular fibrous tissue. Heterogeneity of tissue distribution was quantified using the glandular tissue distribution index, Idist. The phantom had 5 cm compressed breast thickness (MLO and CC views) and 29% whole breast glandular percentage. Results: Differences as high as 116% were found between the MGD coefficients with the homogeneous breast core assumption and those from the corresponding ground truth. Higher differences were found for cases with more heterogeneous distribution of glandular tissue. The Idist for all cases was in the [−0.8{sup −}+0.3] range. The use of the methods presented in this work results in better agreement with ground truth with an improvement as high as 105 pp. The decrease in difference across all phantom cases was in the [9{sup −}105] pp range, dependent on the distribution of glandular tissue and was larger for the cases with the highest Idist values. Conclusion: Our results suggest that the use of corrected glandularity image pairs, as well as the HLB geometry, improves the estimates of MGD conversion coefficients by accounting for the distribution of glandular tissue within the breast. The accuracy of this approach with respect to ground truth is highly dependent on the particular glandular tissue distribution studied. Predrag Bakic discloses current funding from NIH, NSF, and DoD, former funding from Real Time Tomography, LLC and a current research collaboration with Barco and Hologic.

60 APPLIED LIFE SCIENCES↗

Interfacial Effects on Transport Coefficient Measurements in Li-ion Battery Electrolytes

Development of Li + -containing electrolytes with improved transport properties requires reliable, reproducible, and ideally low volume techniques to rigorously understand ion-transport with varying composition. Precisely measuring the complete set of transport coefficients in liquid electrolytes under battery-relevant operating conditions is difficult and the reliability of these methods are sparsely described in electrolyte transport literature. In this work, we apply a potentiostatic polarization-based transport characterization approach typically used for polymer electrolytes to liquid electrolyte systems in an attempt to fully measure all transport coefficients (conductivity, total salt diffusion coefficient, thermodynamic factor and transference number) for the model system of LiPF 6 in an ethylene carbonate—ethyl methyl carbonate (EC:EMC) mixture. Using systematic timescale and statistical analyses, we find that transport coefficients measured using potentiostatic polarization of Li-Li symmetric cells exhibit strong correlation to Li electrode interfacial resistance, indicating that such methods are probing both bulk and interfacial phenomena. This reveals a major roadblock in characterizing electrolyte systems where the interfacial resistance is significantly larger than ohmic electrolyte resistance. As a result, we find that methods that rely on potentiostatic Li metal stripping/plating do not readily result in reliable liquid electrolyte transport coefficients, unlike similar methods for solid polymer electrolytes, where interfacial resistances are typically smaller than electrolyte resistances at the elevated temperatures typically of interest for such electrolytes.

25 ENERGY STORAGE↗

A simple method for obtaining heat capacity coefficients of minerals

Abstract Heat capacity data are unavailable or incomplete for many minerals at geologically relevant temperatures. Despite the availability of entropy and enthalpy values in numerous thermodynamic tables (even sometimes at elevated temperatures), there remains need for extrapolation beyond, or interpolation between, temperatures. This approach inevitably results in estimates for entropy and enthalpy values because the heat capacity coefficients required for optimal thermodynamic treatment are less frequently available. Here we propose a simple method for obtaining heat capacity coefficients of minerals. This method requires only the empirically measured temperature-specific heat capacity for calculation via a matrix algorithm. The system of equations solver is written in the Python computing language and has been made accessible in an online repository. Thermodynamically, the solution to a system of equations represents the heat capacity coefficients that satisfy the mineral-specific polynomial. Direct coefficient calculation will result in more robust thermodynamic data, which are not subject to fitting uncertainties. Using hematite as an example, this method provides results that are comparable to conventional means and is applicable to any solid material. Coefficients vary within the traditional large 950 K temperature interval, indicating that best results should instead utilize a smaller 400 K temperature interval. Examples of large-scale implications include the refinement of geothermal gradient estimation in rapidly subsiding sedimentary basins or metamorphic and hydrothermal evolution.

Geochemistry & Geophysics↗

A MATLAB GUI for the prediction of coefficients of restitution

The motivation behind a MATLAB GUI to predict the coefficients of restitution is to enhance the fidelity of rigid body simulations. Currently, the common practice is to use the coefficient of restitution as a way to capture numerous factors of damping instead of using a coefficient true to the materials in contact. By switching to a model that predicts the coefficient of restitution as a function of velocity between any two materials, rigid body simulations will be more accurate due to higher fidelity models of the actual physics. Additionally, by packaging this software with a library of materials, all rigid body simulations can be run using consistent properties, eliminating any guesswork and “ballpark” figures. This report will therefore cover the existing code and how it delivers all of the features needed to easily estimate coefficients of restitution.

Volk, Christopher Patterson↗

Low-speed aerodynamic characteristics of an airfoil optimized for maximum lift coefficient

An investigation has been conducted in the Langley low-turbulence pressure tunnel to determine the two-dimensional characteristics of an airfoil optimized for maximum lift coefficient. The design maximum lift coefficient was 2.1 at a Reynolds number of 9.7 million. The airfoil with a smooth surface and with surface roughness was tested at angles of attack from 6 deg to 26 deg, Reynolds numbers (based on airfoil chord) from 2.0 million to 12.9 million, and Mach numbers from 0.10 to 0.35. The experimental results are compared with values predicted by theory. The experimental pressure distributions observed at angles of attack up to at least 12 deg were similar to the theoretical values except for a slight increase in the experimental upper-surface pressure coefficients forward of 26 percent chord and a more severe gradient just behind the minimum-pressure-coefficient location. The maximum lift coefficients were measured with the model surface smooth and, depending on test conditions, varied from 1.5 to 1.6 whereas the design value was 2.1.

Bingham, G. J.↗

Zonal and tesseral harmonic coefficients for the geopotential function, from zero to 18th order

Zonal and tesseral harmonic coefficients for the geopotential function are usually tabulated in normalized form to provide immediate information as to the relative significance of the coefficients in the gravity model. The normalized form of the geopotential coefficients cannot be used for computational purposes unless the gravity model has been modified to receive them. This modification is usually not done because the absolute or unnormalized form of the coefficients can be obtained from the simple mathematical relationship that relates the two forms. This computation can be quite tedious for hand calculation, especially for the higher order terms, and can be costly in terms of storage and execution time for machine computation. In this report, zonal and tesseral harmonic coefficients for the geopotential function are tabulated in absolute or unnormalized form. The report is designed to be used as a ready reference for both hand and machine calculation to save the user time and effort.

Kirkpatrick, J. C.↗

Description of a Computer Program Written for Approach and Landing Test Post Flight Data Extraction of Proximity Separation Aerodynamic Coefficients and Aerodynamic Data Base Verification

A computer program written to calculate the proximity aerodynamic force and moment coefficients of the Orbiter/Shuttle Carrier Aircraft (SCA) vehicles based on flight instrumentation is described. The ground reduced aerodynamic coefficients and instrumentation errors (GRACIE) program was developed as a tool to aid in flight test verification of the Orbiter/SCA separation aerodynamic data base. The program calculates the force and moment coefficients of each vehicle in proximity to the other, using the load measurement system data, flight instrumentation data and the vehicle mass properties. The uncertainty in each coefficient is determined, based on the quoted instrumentation accuracies. A subroutine manipulates the Orbiter/747 Carrier Separation Aerodynamic Data Book to calculate a comparable set of predicted coefficients for comparison to the calculated flight test data.

Homan, D. J.↗

Refinement of the aeronomically determined rate coefficient for the reaction of N2/+/ with O

An earlier aeronomic determination of the rate coefficient for the reaction N2(+) + O yields NO(+) + N using Atmosphere Explorer data indicated a small increase in the rate coefficient with ion temperature, contrary to laboratory observations. This was incorrectly attributed to neglect of an increase in the N2(+) recombination rate with vibrational excitation. Recent aeronomical results have shown that the rate coefficient for charge exchange of O(+)(2D) with N2 is about an order of magnitude smaller at thermal temperatures than at energies greater than 0.5 eV (i.e., energies at which laboratory measurements have been made). It is shown that the use of the smaller charge exchange rate coefficient coupled with recent results on N2 quenching of O(+)(2D) yields a temperature dependence in excellent agreement with the laboratory results for the rate coefficient.

Torr, D. G.↗

Absorption coefficients of ozone for the backscatter UV experiment

Band-averaged absorption coefficients for the wavelength channels of the backscatter ultraviolet (BUV) experiment computed with the laboratory ozone absorption measurements are presented. The coefficients ranged from plus or minus 11 to plus or minus 4% about the range midpoint for the major ozone-determining channels on the BUV; these percentage uncertainties in the band absorption coefficients lead to similar uncertainties in the absolute values of derived total ozone because of their reciprocal relationship. Derived total-ozone ratios of the BUV A:B pairs, the Dobson (1963) AD:CD double pairs; and the BUV B:Dobson AD are estimated for the different sets of coefficients based on the ratios experimentally observed in the BUV and Dobson data. It is shown that the Inn and Tanaka (1959) measurements produce the most consistent results, and band-averaged coefficients for the BUV-profiling wavelengths are computed.

Klenk, K. F.↗

Determination of the hypersonic-continuum/rarefied-flow drag coefficient of the Viking lander capsule 1 aeroshell from flight data

Results of an investigation to determine the full scale drag coefficient in the high speed, low density regime of the Viking lander capsule 1 entry vehicle are presented. The principal flight data used in the study were from onboard pressure, mass spectrometer, and accelerometer instrumentation. The hypersonic continuum flow drag coefficient was unambiguously obtained from pressure and accelerometer data; the free molecule flow drag coefficient was indirectly estimated from accelerometer and mass spectrometer data; the slip flow drag coefficient variation was obtained from an appropriate scaling of existing experimental sphere data. Comparison of the flight derived drag hypersonic continuum flow regime except for Reynolds numbers from 1000 to 100,000, for which an unaccountable difference between flight and ground test data of about 8% existed. The flight derived drag coefficients in the free molecule flow regime were considerably larger than those previously calculated with classical theory. The general character of the previously determined temperature profile was not changed appreciably by the results of this investigation; however, a slightly more symmetrical temperature variation at the highest altitudes was obtained.

Blanchard, R. C.↗

Diffusion and viscosity coefficients for helium

The first order Boltzmann-Fokker-Planck equation is solved numerically to obtain diffusion and viscosity coefficients for a ternary gas mixture composed of electron, protons, and helium. The coefficients are tabulated for five He/H abundances ranging from 0.01 to 10 and for both He II and He III. Comparison with Burgers's thermal diffusion coefficients reveals a maximum difference of 9-10% for both He II and He III throughout the range of helium abundances considered. The viscosity coefficients are compared to those of Chapman and Cowling and show a maximum difference of only 5-6% for He II but 15-16% for He III. For the astrophysically important gas mixtures, it is concluded that the results of existing studies which employed Burgers's or Chapman and Cowling's coefficients will remain substantially unaltered.

Roussel-Dupre, R.↗

Damage and coefficients and thermal annealing of irradiated silicon and GaAs solar cells

Electron and proton damage coefficients have been measured for several types of silicon cells of recent manufacture using 1 MeV electrons and protons with energies of 8.3, 17.5 and 40 MeV. LPE (AlGa)As-GaAs cells were also irradiated and pseudodamage coefficients derived under the assumption that the irradiation changes the diffusion length in only one of the n- or p-type layers. After irradiation the cells were annealed isochronally up to 450 C. The damage coefficient and annealing data for silicon cells are in substantial agreement with previous work. The GaAs cells have pseudo-damage coefficients which are dependent on fluence, and have about the same energy dependence as Si damage coefficients.

Anspaugh, B. E.↗

Collisional excitation rate coefficients for Fe XI

It is pointed out that electron collisional rate coefficients for iron ions are important atomic data for studies of both laboratory and astrophysical plasmas. Datla et al. (1975) have measured the ionization and relative excitation rate coefficients for Fe VIII, Fe IX, and Fe X. The present investigation is concerned with the relative excitation rate coefficients for Fe XI. Absolute intensities of VUV transitions 3s2 3p3 3d-3s2 3p4, 3s 3p5-3s2 3p4, and 3s2 3p3 4s-3s2 3p4 in Fe XI are measured and interpreted in terms of excitation rate coefficients. Data regarding the Fe XI line intensities and plasma parameters, and the relative excitation rate coefficients for Fe XI are provided in tables.

Wang, J.-S.↗

Measurement of heat-transfer coefficients in shock wave-turbulent boundary layer interaction regions with a multi-layered thin film heat transfer gauge

A thin film heat transfer gauge is applied to the measurement of heat transfer coefficients in the interaction regions of incident shock waves and fully developed turbulent boundary layers. It was developed to measure heat flux with high spatial resolution and fast response for wind tunnels with long flow duration. To measure the heat transfer coefficients in the interaction region in detail, experiments were performed under the conditions of Mach number = 4, total pressure = 1.2 MPa, 0.59 to approximately 0.65. Reynolds number = 1.3 to approximately 1.5 x 10 to the 7th power and incident shock angles from 17.8 to 22.8 degrees. The results show that the heat transfer coefficient changes complicatedly in the interaction region. At the beginning the interaction region, the heat transfer coefficient decreases at first, reaches its minimum value at the point where the pressure begins to increase, and then increases sharply. When the boundary layer begins to separate, even a small separation bubble causes significant changes in the heat transfer coefficient, while the pressure does not show any changes which suggests that the boundary layer begins to separate.

Hayashi, M.↗