Reliable Ignition of LOX Methane Propellants in Thermal Vacuum Environment

The goal of this project is to demonstrate reliable ignition of liquid oxygen-liquid methane at thermal vacuum conditions using a coil-on-plug (COP) sparking exciter. Testing will be performed using EP’s Frost-Mint cryogenic propellant test stand, using an engine updated based on data collected from previous engine testing at Plum Brook Station, to determine conditions under which the cryogenic propellants will consistently and reliably ignite. In FY22 the project successfully completed the following milestones. The cryogenic test stand Frost-Mint was upgraded to include an integrated vacuum tube and liquid nitrogen cooling system enabling cold vacuum ignition testing. The Integrated GN2/LN2 Ultra-Low-temperature Enclosure (IGLUE), a custom-built close-coupled heater exchanger shroud was designed, fabricated, tested and integrated into the test stand. The vacuum tube and IGLUE enabled the thruster body and propellants to be conditioned to temperatures and pressures desired. This work recreated the no-light conditions experienced during vehicle-level thermal vacuum testing and obtained thruster performance data and ignition imagery.

liquid oxygen↗

Independent Technical Assessment of NASA and External Quantum Sensing Capability

The recent FY 2020 federal Research and Development Budget Priorities memo addresses the leadership need in Quantum Information Science (QIS) directing agencies to “prioritize QIS research and development (R&D), which will build the technical and scientific base necessary to explore the next generation of QIS theory, devices, and applications.” Quantum Sensing (QS) is an integral part of QIS. NASA is a key part of the directive to forward American space exploration and commercialization by providing “capabilities that have broad potential applications in space and on Earth.” QS provides an arena for NASA to demonstrate leadership in both areas of the administrative directive. QS uses quantum properties to achieve unprecedented measurement sensitivity and performance, including quantum-enhanced methodologies that outperform their classical counterparts. Typical quantum sensors exploit techniques such as atomic systems, matter waves, quantum entanglement, quantum superposition of states, quantum illumination methods, and manipulation of photons and atoms, in general. Guided by advancements in our ability to generate, manipulate, and control quantum systems, the emerging quantum sensing technologies promise unrivalled sensitivity, resolution, and precision, potentially leading to game-changing applications. Significant gains include technologies important for a range of NASA missions such as remote sensing, in situ measurements, metrology, interferometry, quantum communication, ranging, imaging, radar and lidar receivers, and gravity measurements. NASA Engineering and Safety Center has convened an independent external panel, comprising of Quantum Sensing Experts from Government, DoD, academia, and Federally funded Research and Development Center to conduct an independent technical assessment of the agency's capabilities in Quantum Sensing to understand NASA's internal needs and competencies related to Quantum Sensing and compare agency capabilities with those available externally including industry, academia, and other government agencies. The outcomes of the assessment will help the agency in establishing appropriate strategies and investments to develop and maintain the state-of-the-art sensing competence and capabilities required to meet the agency’s future needs. The External Experts Panel (EEP) is collaborating with HQ, various NASA Center and the representatives in the NASA Quantum Sensing Community of Practice (QS CoP), a part of NASA Sensors and Instrumentation Technical Fellow Technical Discipline Team, in obtaining common, current understanding of agency mission needs where QS can be an important enabler for future needs, and any programs, projects, assets, and technologists working in QS. The EEP organized a Quantum Sensing Workshop of practitioners from industry, academia, other government agencies, external experts, and interested NASA personnel to gather the assessment information. EEP also conducted information gathering on the industry at large, educational institutions, and other government agency research efforts for capture in the assessment database. At the conclusion of this assessment, EEP team will develop findings and conclusions describing NASA’s capabilities for the mission needs, NASA's relative position on new, enabling technologies, and an analysis of the gaps that may present any risks to near-term or far-term mission needs. This presentation will give details of the NASA and External Quantum Sensing Assessment outcomes, findings, observations, and its recommendation to NASA as how it can advance Quantum Sensing technologies and techniques for its science and explorations related missions.

External Quantum Sensing Capability↗

NASA and External Quantum Sensing Capability Assessment for NASA Space-Based Science Measurements

The Subject Matter Experts in the Sensors & Instrumentation Quantum Sensing Community of Practice (CoP) requested an independent technical assessment of the agency's capabilities in QS to understand NASA's internal needs and competencies related to QS and compare agency capabilities with those available externally including industry, academia, and other government agencies. The outcomes of the assessment will help the agency in establishing appropriate strategies and investments to develop and maintain the state-of-the-art sensing competence and capabilities required to meet the agency’s future needs. NASA Engineering and Safety Center Review Board approved the assessment request and assigned NASA Technical Fellow to lead and conduct the assessment by engaging NASA Centers, NASA HQ and an independent, non-commercial, and highly credible Quantum Sensing Experts from Academia, Department of Defense, other Government Agencies. The assessment started in October 2021 and final report was completed in October 2023.

External Quantum Sensing↗

Federal USS Synthesis Effort: 2023 Flight Test Report. A NASA and Department of Defense Joint Evaluation of Multi-Domain Airspace Integration

In recent years, advancements in technology have greatly improved the utility and applicability of Uncrewed Aircraft Systems (UAS) and have highlighted the need for and importance of UAS Traffic Management (UTM). Onboard sense and avoid systems, ground-based sensors, and long- range command and control (C2) systems have significantly expanded the possibilities for UAS beyond visual line of sight (BVLOS) operations. Initially, research on UTM flights focused on their interactions with other UTM operations, but that has since been expanded to include interactions with the flight profiles of Advanced Air Mobility (AAM) and upper Class E Traffic Management (ETM) operations. Recognizing the potential of these systems and the increase in UAS autonomy, the Department of Defense (DoD) is working towards integrating these missions and systems into a unified DoD Federal ecosystem. The Federal USS Synthesis Effort (FUSE) aims to develop a live system that can efficiently combine this wide range of UTM, AAM, and ETM systems, thus enabling expanded operations within a single common operating environment. The goal of the Federal USS Synthesis Effort (FUSE) is for NASA and the DoD to develop a live system that can efficiently combine UTM, AAM, and ETM systems. The most recent endeavor in this effort was a live flight test conducted near Grand Forks Air Force Base in June, 2023, where the FUSE ecosystem successfully demonstrated integrating UTM, AAM, and ETM operations while providing a single, shared COP to users. Additional investigations were made during the test, including assessing the usefulness of the system and its capability to support UAS weighing over 55 lbs.; testing user messaging capabilities and a DoD adaptation of a Federal USS; and assessing user workload, automated vs manual control, and the usability of NASA’s XTMClient.

Federal USS↗

Upper Class E Traffic Management: NASA's Collaborative Research and Technical Development to Enable Routine, Safe, and Scalable High Altitude Operation

In the past, operations at high altitudes have been limited in number and largely conducted for defense/security purposes. However, with broad technological advances, a growing number of commerical and public good use cases, and a significant rise in the number of capable platforms, the demand for operating in high altitude airspace - known as upper Class E in the United States - is increasing. With that increase in demand comes the need for a means to manage the airspace in a way that does not burden current air traffic services and infrastructure given that provisions for commercial operations are limited. NASA, in collaboration with other government agencies and strong representation from industry, has developed a cooperative approach to airspace management referred to as Upper Class E Traffic Management (ETM). Key aspects of the ETM concept are the ability to exchange information through services that enable the operators to share airspace in cetain areas by adhering to cooperative operating practices (COPs) and by having shared situation awareness. To advance the concept, NASA recently developed and formally tested the first dedicated reference ETM system and supportin architecture. The test involved real-time simulation of high altitude operations with a diverse set of aircraft and encourter situations that included industry partners connected to the system from their remote operating centers. This presentation will provide attendees with an understanding of the ETM concept, the details and importance of the system that has been developed, an overview of the groundbreaking simulation, and a glimpse of things to come in our next steps.

Conrad Dang-Gabriel↗

Provider of Services for Urban Air Mobility (PSU) Prototype Simulation (X5) Final Report

Urban Air Mobility (UAM) is a new air transportation service concept to carry passengers or cargo in metropolitan areas, leveraged by innovative aircraft and air traffic automation technologies. NASA has conducted a series of simulations, called the X-series simulation, to evaluate the UAM concept of operations and support the development of airspace procedures and services for UAM operations. The simulation called “X5” was conducted in 2023 to test a Provider of Services for UAM (PSU) prototype developed by NASA for UAM flight planning, strategic conflict management support, and data exchange between UAM operators. In this simulation, two strategic conflict management capabilities, Demand-Capacity Balancing and Sequencing and Scheduling, were further investigated. This document describes the UAM system architecture modeled, the X5 simulation environment to be executed (e.g., traffic scenario and UAM airspace construct), and the strategic conflict management processes developed and evaluated in this study. Then, the simulation results are provided using several system performance metrics, such as the number of operations planned and activated, demand-capacity imbalances detected and resolved, and pre-departure delays. Based on these metrics, the test findings and lessons learned from this simulation are discussed. NASA developed a PSU prototype as part of a reference implementation of UAM system architecture and evolved strategic conflict management capabilities for UAM operations from the previous collaborative simulations with industry partners. Below is the summary of the achievements: - Aligned NASA’s UAM reference architecture with the FAA’s UAM ConOps notional architecture - Extended UAM airspace management capabilities to include 1) Demand-Capacity Balancing (DCB) to ensure operators coordinate planned usage of shared vertiports, and 2) Sequencing and Scheduling (S&S) at UAM corridor entry and exit points to help facilitate an orderly flow of traffic - Defined the PSU information exchange APIs and requirements towards informing industry standards - Developed and tested a NASA PSU prototype as reference implementation to validate the requirements and APIs - Developed a prototype service connecting NASA’s PSU and the FAA system for testing future PSU-ATM interface requirements - Tested NASA-developed assumptions for UAM operations such as airspace design, procedures, vehicle performance, and strategic conflict management methods to inform future Cooperative Operating Practices (COPs) development with industry - Evaluated system performance metrics such as number of simultaneous operations and ground delays that can help define system-level requirements. The simulation results showed that the UAM traffic demand could be managed to minimize the needs of tactical separation provision with ground delays assigned by DCB and S&S. These accomplishments and the lessons learned from the PSU Prototype X5 simulation activities will be valuable inputs for the Air Mobility Pathfinders (AMP) project, which is NASA’s new project to create and evaluate a reference architecture for safe, secure, and scalable UAM operations.

Simulation↗

CBRN Situational Awareness Tools for the Modern Age

CBRN Situational awareness (SA) should be a key operational requirement in the CNI area of discussion, not only for the “boots-on-the-ground” warfighter, but at a strategic level. For example, maneuver plans will need to be developed for contamination avoidance and battlefield survivability. Large datasets from instruments dispersed across the battlefield will thus need to be collected and processed into a holistic assessment of the radiological hazard. From there, hazard maps then must be distributed at the tactical level, all while continuing to effectively engage a peer adversary. This vision represents a network of sensors, software tools, data processing algorithms, communications suites, and common operational picture (COP) platforms working in concert to inform warfighters and command echelons alike of evolving nuclear and radiological hazards. This complex system-of-systems and the ultimate goal of effective engagement in a nuclear or radiological-hazard battlefield can be achieved through pursuit of improvement in collaborative SA tools.

Becker, Eric M.↗

EMPIRICAL VALIDATION OF MULTI-ZONE BUILDING AND HVAC SYSTEM MODELS UNDER UNCERTAINTY

This study implemented a framework of empirical validation of building energy models under uncertainty to a set of controlled experiments that aim to validate multi-zone building and HVAC system models. Energy models were created through iterative acquisitions of information and data and uses measurement data from various types of sensors as both inputs and as observations to validate predictions. Experimental and modeling uncertainties were quantified and propagated accordingly, and probabilistic accuracy metrics were used to evaluate the agreement between model predictions and observations under uncertainty. Sensitivity analysis was performed to identify the most influential uncertainties that will be prioritized to be addressed in the next steps. Current results of two cooling tests show an overall good agreement between predictions and observations on a set of HVAC system outputs despite considerable and influential uncertainty in DX cooling coil COP. Agreements on zone-level responses vary notably among individual rooms, likely because of significant uncertainties in room radiation heat gain and system supply air.

Li, Qi↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Electrocaloric cooling with electrostatic actuation

A solid-state heat transporting device including a heat transporting element whose uniformity of contact with one or multiple surfaces is controllable so that various amounts of heat may be transported to and from the one or multiple surfaces. The heat transporting element uses the electrocaloric effect to absorb and release the heat and the uniformity of contact is controlled using an electrostatic effect which may change the shape of the heat transporting element. In one embodiment, the heat transporting element is an electrostatically actuated P(VDF-TrFE-CFE) polymer stack achieving a high specific cooling power of 2.8 W/g and a COP of 13 (the highest reported coefficient of performance to date) when used as a cooling device.

42 ENGINEERING↗

High performance earth-abundant electrocatalysts for hydrogen evolution reaction and other reactions

Electrodes for catalyzing electrochemical reactions (e.g., the hydrogen evolution reaction) are provided. The electrode may comprise a ternary pyrite-phase transition metal phosphochalcogenide (e.g., CoPS) disposed on a substrate, wherein the ternary pyrite-phase transition metal phosphochalcogenide is a solid material of a ternary compound of a transition metal, phosphorous (P), and a chalcogen, the solid material characterized by a substantially single, ternary alloy phase having a pyrite crystal structure. Methods of using and making the electrodes are also provided.

Jin, Song↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗