Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CSI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Very High Momentum Particle Identification Detector for the ALICE experiment

The main purpose of the ALICE experiment at CERN is to identify and study the quark-gluon plasma (QGP) in heavy ion collisions at the LHC. Among others, hadrochemistry allows for a detailed insight into the characteristics of the high temperature and density system created in these events. It is therefore important to be able to identify charged particles on a track by track basis. Moreover, results from high energy nucleus-nucleus collisions obtained by other experiments (e.g. at RHIC) indicate that it is imperative to extend the detection capability of ALICE to higher momenta. To meet these challenges, we propose the construction of the Very High Momentum Particle Identification Detector (VHMPID), which aims to identify charged pions, kaons, protons and antiprotons in the momentum range of 10 GeV/c<p{sub T}<30 GeV/c. In this contribution we will review the relevant physics arguments in proton-proton and heavy ion collisions as well as the detector proposal based on a RICH (Ring Imaging Cherenkov) detector with a C{sub 4}F{sub 10} radiator and a MWPC based CsI photon counter. In addition, we will present the advances in the development of an alternative multi-THGEM based CsI photon detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo Simulation of Gamma-Ray Response of BaF2 and CaF2

We have employed a Monte Carlo (MC) method to study intrinsic properties of two alkaline-earth halides, namely BaF2 and CaF2, relevant to their use as radiation detector materials. The MC method follows the fate of individual electron-hole (e-h) pairs and thus allows for a detailed description of the microscopic structure of ionization tracks created by incident γ-ray radiation. The properties of interest include the mean energy required to create an e-h pair, W, Fano factor, F, the maximum theoretical light yield, and the spatial distribution of e-h pairs resulting from γ-ray excitation. Although W and F vary with incident photon energy at low energies, they tend to constant values at energies higher than 1 keV. W is determined to be 18.9 and 19.8 eV for BaF2 and CaF2, respectively, in agreement with published data. The e-h pair spatial distributions exhibit a linear distribution along the fast electron tracks with high e-h pair densities at the end of the tracks. Most e-h pairs are created by interband transition and plasmon excitation in both scintillators, but the e-h pairs along fast electron tracks in BaF2 are slightly clustered, forming nanoscale domains and resulting in the higher e-h pair densities than in CaF2. Combining the maximum theoretical light yields calculated for BaF2 and CaF2 with those obtained for CsI and NaI shows that the theoretical light yield decreases linearly with increasing band gap energy.

detector materials↗

Enhanced quantum efficiency from hybrid cesium halide/copper photocathodes

The quantum efficiency (QE) of Cu is found to increase dramatically when coated by a CsI film and then irradiated by a UV laser. Over three orders of magnitude quantum efficiency enhancement at 266 nm is observed in CsI/Cu(100), indicating potential application in future photocathode devices. Upon laser irradiation, a large work function reduction to a value less than 2 eV is also observed, significantly greater than for similarly treated CsBr/Cu(100). The initial QE enhancement, prior to laser irradiation, is attributed to interface interaction and the intrinsic properties of the Cs halide film. Further QE enhancement following activation is attributed to formation of inter-band states and Cs metal accumulation at the interface induced by laser irradiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A split imaging spectrometer for temporally and spatially resolved titanium absorption spectroscopy

We present a temporally and a spatially resolved spectrometer for titanium x-ray absorption spectroscopy along 2 axial symmetric lines-of-sight. Each line-of-sight of the instrument uses an elliptical crystal to acquire both the 2p and 3p Ti absorption lines on a single, time gated channel of the instrument. The 2 axial symmetric lines-of-sight allow the 2p and 3p absorption features to be measured through the same point in space using both channels of the instrument. The spatially dependent material temperature can be inferred by observing the 2p and the 3p Ti absorption features. The data are recorded on a two strip framing camera with each strip collecting data from a single line-of-sight. The design is compatible for use at both the OMEGA laser and the National Ignition Facility. The spectrometer is intended to measure the material temperature behind a Marshak wave in a radiatively driven SiO{sub 2} foam with a Ti foam tracer. In this configuration, a broad band CsI backlighter will be used for a source and the Ti absorption spectrum measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alkali halide microstructured optical fiber for X-ray detection

Microstructured optical fibers containing alkali halide scintillation materials of CsI(Na), CsI(Tl), and NaI(Tl) are presented. The scintillation materials are grown inside the microstructured fibers using a modified Bridgman-Stockbarger technique. The x-ray photon counts of these fibers, with and without an aluminum film coating are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The photon count results show significant variations in the fiber output based on the materials. The alkali halide fiber output can exceed that of the CdTe detector, dependent upon photon counter efficiency and fiber configuration. The results and associated materials difference are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

Here, developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C 60 , AlPcCl:C 70 , and P3HT:PC 61 BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy -1 cm -2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

36 MATERIALS SCIENCE↗

Surface physicochemical properties and decay of the low-lying isomer in the {sup 229}Th nucleus

The effect of the {sup 229}Th nucleus proximity to the CsI surface on the decay probability of its anomalously low lying isomeric level is studied. Results of experimental and theoretical studies show that the CsI surface does not produce chemical bonding with Th and does not noticeably change its valence shells. Hence, it is an optimal substrate for measuring the probability of the {sup 229}Th isomer state decay via internal electron conversion. The half-life of the {sup 229}Th{sup m} isomer in the thorium atom is calculated for neutral chemical environment. (paper)

07 ISOTOPE AND RADIATION SOURCES↗

The Carnegie-Spitzer-IMACS redshift survey of galaxy evolution since z = 1.5. I. Description and methodology

We describe the Carnegie-Spitzer-IMACS (CSI) Survey, a wide-field, near-IR selected spectrophotometric redshift survey with the Inamori Magellan Areal Camera and Spectrograph (IMACS) on Magellan-Baade. By defining a flux-limited sample of galaxies in Spitzer Infrared Array Camera 3.6 μm imaging of SWIRE fields, the CSI Survey efficiently traces the stellar mass of average galaxies to z ∼ 1.5. This first paper provides an overview of the survey selection, observations, processing of the photometry and spectrophotometry. We also describe the processing of the data: new methods of fitting synthetic templates of spectral energy distributions are used to derive redshifts, stellar masses, emission line luminosities, and coarse information on recent star formation. Our unique methodology for analyzing low-dispersion spectra taken with multilayer prisms in IMACS, combined with panchromatic photometry from the ultraviolet to the IR, has yielded high-quality redshifts for 43,347 galaxies in our first 5.3 deg{sup 2} of the SWIRE XMM-LSS field. We use three different approaches to estimate our redshift errors and find robust agreement. Over the full range of 3.6 μm fluxes of our selection, we find typical redshift uncertainties of σ {sub z}/(1 + z) ≲ 0.015. In comparisons with previously published spectroscopic redshifts we find scatters of σ {sub z}/(1 + z) = 0.011 for galaxies at 0.7 ≤ z ≤ 0.9, and σ {sub z}/(1 + z) = 0.014 for galaxies at 0.9 ≤ z ≤ 1.2. For galaxies brighter and fainter than i = 23 mag, we find σ {sub z}/(1 + z) = 0.008 and σ {sub z}/(1 + z) = 0.022, respectively. Notably, our low-dispersion spectroscopy and analysis yields comparable redshift uncertainties and success rates for both red and blue galaxies, largely eliminating color-based systematics that can seriously bias observed dependencies of galaxy evolution on environment.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

Direct dark matter searches with metal halide perovskites

Polar materials with optical phonons in the meV range are excellent candidates for both dark matter direct detection via dark photon-mediated scattering and light dark matter absorption. In this study, we propose, for the first time, the metal halide perovskites MAPbI 3 , MAPbCl 3 , and CsPbI 3 for these purposes. Our findings reveal that CsPbI 3 is the best material, significantly improving exclusion limits compared to other polar materials. For scattering, CsPbI 3 can probe dark matter masses down to the keV range. For absorption, it enhances sensitivity to detect dark photon masses below ∼10 meV. The only material that has so far been investigated and that could provide competitive bounds is CsI, which, however, demonstrates lower stability as device platform compared to CsPbI 3 . Moreover, CsI is isotropic while the anisotropic structure of CsPbI 3 enables daily modulation analysis, showing that a significant percentage of daily modulation exceeding 1% is achievable for dark matter masses below 40 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Covariance Shaping Over Riemannian Manifolds for Massive MIMO Communication

Acquiring accurate instantaneous channel state information (CSI) is a challenging aspect of massive multi-input multi-output (MIMO) communication. Utilizing statistical information, such as channel covariance matrix, to design statistical beamforming vectors is robust when compared to instantaneous CSI. In this paper, we propose a novel MIMO covariance shaping scheme over Riemannian manifolds. It serves as an effective statistical beamforming solution to a number of close proximity user equipment (UE) that are undergoing substantial channel correlation. Proposed algorithm exploits the Hermitian positive definite nature of covariance matrices lying over Riemannian manifold. We introduce Wasserstein distance function as a Riemannian metric to measure distances between channel covariance matrices. Furthermore, K-means clustering technique is utilized to effectively identify the optimal shape of effective optimal covariance matrices. Our findings suggest that maximizing the geodesic distance between covariance matrices ultimately leads to a corresponding increase in the network throughput, as determined by the beamforming vector used to shape the covariance matrices. Simulation results validate that the proposed solution converges faster than Euclidean-based state-of-the-art, while maintaining the same computational complexity. Finally, the sum rate performance asymptotically achieves full capacity for two-UE case and more than 96% of the upper bound exhaustive search benchmark for multi-UE scenario.

42 ENGINEERING↗

A High-Accuracy Power Loss Model of SiC MOSFETs in Current Source Inverter Considering Current Commutation and Parasitic Parameters

Power loss estimation of power electronic devices is important to the efficiency optimization of motor drives used in many applications. However, most existing simplified power loss models of silicon carbide (SiC) MOSFETs are not sufficiently accurate due to their neglect of parasitic parameters in the current commutation loop. In addition, the loss model of the voltage source inverter (VSI) cannot be directly applied to the current source inverter (CSI) because of differences between their commutation loops. First, the commutation processes for VSIs and CSIs are compared. The voltage and current trajectories of SiC MOSFETs in the switching transition of a CSI-based motor drive system are analyzed in detail. Based on these results, the conduction and switching losses of SiC MOSFETs in CSIs are modeled considering the current commutation details. In addition, the proposed analytical model includes parasitic inductances and capacitances in the current commutation loop. Experimental results have verified that the proposed power loss model delivers higher accuracy loss predictions than the conventional loss model.

current commutation, current source inverter, powe↗

Thermal Stress Reduction in Power Switching Devices Using Distributed Loss PWM Concept for Current Source Inverters

A new modulation scheme is proposed for current source inverters (CSIs) that reduces the variation and peak junction temperature in the CSIs' power devices. The distributed loss pulse-width modulation (DLM) concept is introduced and applied to traditional space vector modulation methods to develop modified modulation schemes that reduce the thermal stress on power devices. The device junction temperatures resulting from conventional and DLM schemes are compared. Simulation and experimental results confirm that the proposed DLM concept reduces thermal stress on the devices while maintaining the same high output current waveform quality compared to traditional CSI modulation schemes. The CSI power device lifetime (i.e., the number of cycles to failure) are estimated using the simulation and experimental results. The proposed DLM significantly increases the device lifetime (by 5 to 6 times) by reducing the junction temperature variation compared to the conventional modulations.

42 ENGINEERING↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonproportionality of Scintillator Detectors. III. Temperature Dependence Studies

This paper is the third in a series of articles on the basic physics of nonproportionality in scintillators. In this work, we focus on the temperature dependence of six scintillators, NaI(Tl), CsI(Tl), CsI(Na), CeBr 3 , LaBr 3 (Ce), and undoped SrI 2 , and report their nonproportionality curves at -40 °C, 0 °C and +40 °C. We fit the data to a modified form of our previously employed model, including the competition of carrier trapping with the Onsager-mediated attraction between electrons and holes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emerging New Pseudobinary and Ternary Halides as Scintillators for Radiation Detection

Recently there has been a discernible shift from simple binary halide scintillators (e.g., NaI, CsI) toward host compounds that are structurally and electronically more complex. Besides SrI 2 and LaBr 3 , several pseudobinary, ternary and quaternary halides have emerged as promising scintillators for radiation detection. Here, we survey our recent first-principles based computational studies of different hosts belonging to a class of mixed halides or distinct stoichiometric compounds. The mixed halides are comprised of simple binary end members, NaI or CsI, that are known scintillators. The ternary compounds belong to a family of iodides of the type AB 2 I 5 or ABI 3 , where the A and B cations are alkali and alkaline-earth metals, respectively. These are usually activated by Eu 2+ . We will consider Eu-dopant behavior in these compounds before delving into a set of ns 2 containing ternaries. They are analogous to the AB 2 I 5 group of materials, except that the ns 2 ion is part of the crystal framework, replacing the alkali “A” ion, e.g., InBa 2 I 5 or TlBa 2 I 5 . Interestingly, we predict Eu 2+ activation will be rendered ineffective in these ns 2 compounds, caused by changes in the valence and conduction band edges. However, the possibility of fast electron capture at ns 2 sites and the prospect of self-activated scintillation could be interesting for detector applications.

Kang, Byungkyun↗

Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging

Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525x525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25x25 {mu}m pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10{sup 5} electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 {mu}m, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at {approx}0.44 {mu}C/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a:Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physical characteristics of GE Senographe Essential and DS digital mammography detectors

The purpose of this study was to investigate physical characteristics of two full field digital mammography (FFDM) systems (GE Senographe Essential and DS). Both are indirect conversion (x ray to light) a-Si flat panels coupled with a CsI(Tl) scintillator. The examined systems have the same pixel size (100 {mu}m) but a different field of view: a conventional size 23x19.2 cm{sup 2} and a large field 24x30.7 cm{sup 2}, specifically designed to image large breasts. In the GE Senographe Essential model relevant improvements in flat panel design were implemented and new deposition tools for metal, a-Si, and CsI(Tl) were introduced by GE. These changes in detector design are expected to be beneficial for advanced applications such as breast tomosynthesis. The presampling modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) were measured for a wide range of exposure (25-240 {mu}Gy) with a RQA-M2 technique (28 kVp with a Mo/Mo target/filter combination and 2 mm of additional aluminum filtration). At 1, 2, and at 4 lp/mm MTF is equal to 0.9, 0.76, and 0.46 for the conventional field detector and to 0.85, 0.59, and 0.24 for the large field detector. The latter detector exhibits an improved NNPS due to a lower electronic noise and a better DQE that reaches 60%. In addition a contrast-detail analysis was performed with CDMAM 3.4 phantom and CDCOM software: GE Senographe DS showed statistically significant poorer detection ability in comparison with the GE Senographe Essential. These results could have been expected, at least qualitatively, considering the relative DQE of the two systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗