Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

AN ANALYTICAL MODEL OF INTERSTELLAR GAS IN THE HELIOSPHERE TAILORED TO INTERSTELLAR BOUNDARY EXPLORER OBSERVATIONS

The stationary distribution of interstellar neutral gas in the heliosphere subject to solar gravity, solar radiation pressure, photoionization, and charge exchange is investigated analytically assuming ionization rates and radiation pressure that are proportional to R{sup -2}, where R is the heliocentric radius. The collisionless hyperbolic trajectories of the individual atoms including ionization losses are combined with Liouville's Theorem to construct the heliospheric phase-space distribution function of an interstellar gas species in the solar reference frame under the assumption that the distribution is a drifting Maxwellian at large distances from the Sun. The distribution is transformed to the Earth (essentially Interstellar Boundary Explorer (IBEX)) frame as a function of solar longitude. The expression is then tailored to the latitudinal scan of IBEX as a function of longitude using the fact that IBEX detects each atom close to perihelion in its hyperbolic orbit. The distribution is further adapted to IBEX by integrating the differential intensity over the entrance aperture solid angle of the IBEX-Lo collimator, and over energy to predict the IBEX count rate of helium. The major features of the predicted count rate are described, including a peak in longitude, a peak in latitude at each longitude, and the widths of the major peak in both latitude and longitude. Analytical formulae for these features are derived for comparison with IBEX observations in order to determine the temperature and bulk velocity of the gas in interstellar space. Based in part on these formulae, the results for helium are presented in the companion paper by Moebius et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrasoft x ray bursts: A clue to the origin of gamma ray bursts?

A search was conducted for short timescale (less than or approx. 10 s) faint X ray bursts in the complete 201,000,000 photon Einstein Observatory imaging proportional counter (IPC) data base. Some 73,000,000 events were extracted which were distributed among 11,230 observing intervals with an average observing time of approx. 1400 seconds. To exclude all sources, only those spatial pixels were searched with a count rate less than 6 x 10(exp -4) counts/sec sq arcmin. The mean count rate was much less. All files with less than 400 secs of observing time were excluded. The data was then binned into overlapping cells 4'.3 by 4'.3 by 10 secs in volume, and all the space-time cells were searched to locate cells with more than 5 counts in a 10 sec interval; i.e., a minimum flux enhancement of 50 over the mean rate for that point in space. Some 52 such events were found. An annulus was inspected around the event to see if it coincided with a general rise in the counter's event rate. Ten events did coincide with counter phenomena; these were associated with sunrise, sunset, or the approach of the South Atlantic Anomaly and were excluded. The remaining 42 events were then examined in an attempt to associate them with instrumental or environmental artifacts. The event occurrence times are uniformly distributed over the course of the mission and show no correlation with local solar time; their positions are randomly distributed in geographic, Galactic, and celestial coordinates. Their summed radial distribution is consistent with the point response function of the IPC for a soft source, indicating that the events are focused by the Observatory's mirror system. The integrated spectrum is, indeed, quite soft and is very similar to that of the cataclysmic variable star U Gem in outburst. Most of the events have risetimes of less than or approx. 1 sec and decay times ranging from 1 to 20 sec. Their positions are not associated with any class of catalogued objects. Several possible origins are discussed for the events; if they are associated with gamma ray bursters, they provide interesting constraints on the space density and repetition rate of the underlying source population.

Helfand, D. J.↗

Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, and the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

First results of the observation of {sup 7}Be solar neutrinos with the BOREXINO detector

The results of a direct measurement of the counting rate for solar neutrinos from the electron-capture process on {sup 7}Be, {sup 7}Be(e{sup -}, {nu}{sub e}){sup 7}Li(E{sub {nu} }= 0.862 MeV), with the low-background scintillation detector BOREXINO are presented. This is the first ever real-time observation of a signal from solar neutrinos of energy below 1 MeV. The counting rate for monoenergetic beryllium neutrinos in the BOREXINO detector proved to be 47 {+-} 7 (stat.) {+-} 12 (syst.) counts/(day x 100 t), which is in agreement with the predictions of the standard solar model and the hypothesis of neutrino oscillations in matter with parameters in the LMA region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dead-time effects in pulse-counting Digicon detectors

The Hubble Space Telescope's High Resolution Spectrograph employs two pulse-counting Digicon detectors to record UV spectra. At higher measured count rates, the intervals between photon arrivals become comparable to the response time of the electronics, so that not every pulse will be counted; this 'paired pulse' effect causes departures from linearity and must be corrected for during raw data reduction. Attention is given to two analytic equations that quantify the dead-time losses. The less attenuated spectra are noted to be severely distorted by these losses; a comparison with the undistorted low count rate data allows a detailed analysis to be made of the pulse-counting characteristics over five decades of input event rates. The present equations and calibration methods should be applicable to all kinds of multichannel pulse-counting detectors.

Ebbets, Dennis C.↗

Hubble Space Telescope observations of the NUV transit of WASP-12b

We present new observations of four closely spaced near-ultraviolet (NUV) transits of the hot Jupiter-like exoplanet WASP-12b using Hubble Space Telescope (HST)/Cosmic Origins Spectrograph (COS), significantly increasing the phase resolution of the observed NUV light curve relative to previous observations, while minimizing the temporal variation of the system. We observe significant excess NUV absorption during the transit, with mean normalized in-transit fluxes of F{sub norm}≃0.97, i.e., ≃2–5σ deeper than the optical transit level of ≃0.986 for a uniform stellar disk (the exact confidence level depending on the normalization method used). We further observe an asymmetric transit shape, such that the post-conjunction fluxes are overall ≃2–3σ higher than pre-conjunction values, and characterized by rapid variations in count rate between the pre-conjunction and out-of-transit levels. We do not find evidence for an early ingress to the NUV transit as suggested by earlier HST observations. However, we show that the NUV count rate observed prior to the optical transit is highly variable, but overall ≃2.2–3.0σ below the post-transit values and comparable in depth to the optical transit, possibly forming a variable region of NUV absorption from at least phase ϕ≃0.83, limited by the data coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Application of a dedicated micro-processor for automatic data acquisition of load strain and acoustic-emission data

This paper describes an automatic system for acquisition, logging and analysis of stress, strain and acoustic emission data. The complete system is a combination of several standard items of equipment and a newly developed intelligent data logger which has the capability to send data directly to a large scale computer for reduction and plotting. The data logging and all interfacing with peripheral equipment are accomplished using digital electronics. The heart of the system is a four-bit microprocessor and digital cassette tape unit. The system, which is controlled by instructions from a cathode ray tube terminal, has the capability to transmit data from the cassette unit to a large computer via a time sharing option. Typical results are presented for acoustic emission count rate and total count curves superimposed on stress-strain diagrams for boron/epoxy advanced composites.

Wilson, G. H.↗

Radioactivities of Long Duration Exposure Facility (LDEF) materials: Baggage and bonanzas

Radioactivities in materials onboard the returned Long Duration Exposure Facility (LDEF) satellite were studied by a variety of techniques. Among the most powerful is low background Ge semiconductor detector gamma ray spectrometry. The observed radioactivities are of two origins: those radionuclides produced by nuclear reactions with the radiation field in orbit and radionuclides present initially as contaminants in materials used for construction of the spacecraft and experimental assemblies. In the first category are experiment related monitor foils and tomato seeds, and such spacecraft materials as Al, stainless steel, and Ti. In the second category are Al, Be, Ti, Va, and some special glasses. Consider that measured peak-area count rates from both categories range from a high value of about 1 count per minute down to less than 0.001 count per minute. Successful measurement of count rates toward the low end of this range can be achieved only through low background techniques, such as used to obtain the results presented here.

Smith, Alan R.↗

Contemporaneous IUE, EUVE, and High-Energy Observations of 3C 273

We present the results of our 1994 January and 1995 January observations of the quasar 3C 273 obtained with the International Ultraviolet Explorer (IUE) and the Extreme-Ultraviolet Explorer (EUVE). These observations were part of a large multiwavelength campaign to observe 3C 273 from radio through gamma-rays. Our 1995 January photometric observations with the EUVE Lexan/B Deep Survey (DS) instrument indicate strong evidence for variability, at a 99% confidence level, during the 12 day observing period. We have utilized ROSAT PSPC soft X-ray power-law models to correlate with EUVE count rates. Besides variations in the normalization level between both observations, our EUV count rates are consistent with a simple power-law model with spectral index alpha approx. 1.77 (F(sub upsilon) proportional to upsilon(sup -alpha) that can be extrapolated from the soft X-rays to the EUV range. The active galactic nucleus 3C 273 is an important blazar to study because in our picture it reveals the presence of both disk and relativistic beam spectral contributions.

Ramos, E.↗

Using Beta Cen to Probe the Photosphere-wind Connection in B Stars

In this project we began by identifying the large number of emission lines visible in the XMM-Newton RGS spectra of Beta Cen. A comprehensive analysis of the temperature structure of the hot gas was carried out by simultaneously fitting the data from all the instruments on the spacecraft. This resulted in a measured temperature range of 0.1-0.6 keV. In more detailed analysis, three characteristic plasma temperatures were found: 0.1, 0.2, and 0.6 keV. The research carried out at UW-Eau Claire primarily focused on two aspects of the data: the analysis of the forbidden line to intercombination line ratio for He-like ions and the time variability of the overall X-ray flux as detected in the direct X-ray images of the star. The analysis of the lines from He-like ions indicate that the Ne IX lines are formed no farther than about 4 stellar radii from the star's photosphere, while the N VI lines are formed within 11 stellar radii of the photosphere. X-ray flux variability would be particularly interesting for this star because it is a known Beta Cep-type variable as seen in optical light: similar variation in the X-ray region would forge an interesting link between the two wavebands. Initial analysis of the X-ray flux was complicated by spikes in the count rates early in the observation. Detailed analysis of the spectral characteristics these count rate anomalies indicated that these flares were probably not intrinsic to the star, rather they were contaminations of the data due to the passage of the satellite through soft proton clouds in the Earth's magnetosphere. An analysis of the light curve of the uncontaminated portions of the light curve did not reveal any variation on the known optical period of variation for this star, and a general search for periodic variability also did not find any significant periods of variation.

Miller, Nathan A.↗

SU-E-I-79: Source Geometry Dependence of Gamma Well-Counter Measurements

Purpose: To determine the effect of liquid sample volume and geometry on counting efficiency in a gamma well-counter, and to assess the relative contributions of sample geometry and self-attenuation. Gamma wellcounters are standard equipment in clinical and preclinical studies, for measuring patient blood radioactivity and quantifying animal tissue uptake for tracer development and other purposes. Accurate measurements are crucial. Methods: Count rates were measured for aqueous solutions of 99m- Tc at four liquid volume values in a 1-cm-diam tube and at six volume values in a 2.2-cm-diam vial. Total activity was constant for all volumes, and data were corrected for decay. Count rates from a point source in air, supported by a filter paper, were measured at seven heights between 1.3 and 5.7 cm from the bottom of a tube. Results: Sample volume effects were larger for the tube than for the vial. For the tube, count efficiency relative to a 1-cc volume ranged from 1.05 at 0.05 cc to 0.84 at 3 cc. For the vial, relative count efficiency ranged from 1.02 at 0.05 cc to 0.87 at 15 cc. For the point source, count efficiency relative to 1.3 cm from the tube bottom ranged from 0.98 at 1.8 cm to 0.34 at 5.7 cm. The relative efficiency of a 3-cc liquid sample in a tube compared to a 1-cc sample is 0.84; the average relative efficiency for the solid sample in air between heights in the tube corresponding to the surfaces of those volumes (1.3 and 4.8 cm) is 0.81, implying that the major contribution to efficiency loss is geometry, rather than attenuation. Conclusion: Volume-dependent correction factors should be used for accurate quantitation radioactive of liquid samples. Solid samples should be positioned at the bottom of the tube for maximum count efficiency.

60 APPLIED LIFE SCIENCES↗

Spent Fuel Assay with an Ultra-High Rate HPGe Spectrometer

Traditional verification of spent nuclear fuel (SNF) includes determination of initial enrichment, burnup and cool down time (IE, BU, CT). Along with neutron measurements, passive gamma assay provides important information for determining BU and CT. Other gamma-ray-based assay methods such as passive tomography and active delayed gamma offer the potential to measure the spatial distribution of fission products and the fissile isotopic concentration of the fuel, respectively. All fuel verification methods involving gamma-ray spectroscopy require that the spectrometers manage very high count rates while extracting the signatures of interest. PNNL has developed new digital filtering and analysis techniques to produce an ultra-high rate gamma-ray spectrometer from a standard coaxial high-purity germanium (HPGe) crystal. This 37% relative efficiency detector has been operated for SNF measurements at input count rates of 500-1300 kcps and throughput in excess of 150 kcps. Optimized filtering algorithms preserve the spectroscopic capability of the system even at these high rates. This paper will present the results of both passive and active SNF measurement performed with this system at PNNL. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Equipment for subcriticality monitoring by pulse method - 240

At the present time methods and means of determining, evaluating, and monitoring the effective neutron multiplication factor or the subcriticality are becoming very important for validating and monitoring nuclear safety in connection with the accumulation of a large number of spent fuel assemblies and the transition to a more tight mode of their storage arrangement in the spent-fuel pools of NPP. Pulse method is an effective subcriticality monitoring tool for subcritical reactors and spent nuclear fuel storages. This method is based on the use neutron generator, fission chambers and instrumentation for data acquisition and processing. The measurement and control equipment was designed. It allows: neutron pulses generation with specified parameters; neutron flux response monitoring by measuring the count rate at predetermined set of sequential time intervals; data transmitting to the personal computer; data processing and subcriticality calculation; self diagnostics and health monitoring; data recording, archiving and storage. The special device is proposed to check the electronic equipment. This device simulates a signal of a neutron detector counting rate after neutron generator pulses appear. The paper presents hardware structure and composition, specification and software of the control unit, which provides neutron generator operation, data acquisition and processing. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

THE CHANDRA SURVEY OF THE COSMOS FIELD. II. SOURCE DETECTION AND PHOTOMETRY

The Chandra COSMOS Survey (C-COSMOS) is a large, 1.8 Ms, Chandra program that covers the central contiguous {approx}0.92 deg{sup 2} of the COSMOS field. C-COSMOS is the result of a complex tiling, with every position being observed in up to six overlapping pointings (four overlapping pointings in most of the central {approx}0.45 deg{sup 2} area with the best exposure, and two overlapping pointings in most of the surrounding area, covering an additional {approx}0.47 deg{sup 2}). Therefore, the full exploitation of the C-COSMOS data requires a dedicated and accurate analysis focused on three main issues: (1) maximizing the sensitivity when the point-spread function (PSF) changes strongly among different observations of the same source (from {approx}1 arcsec up to {approx}10 arcsec half-power radius); (2) resolving close pairs; and (3) obtaining the best source localization and count rate. We present here our treatment of four key analysis items: source detection, localization, photometry, and survey sensitivity. Our final procedure consists of a two step procedure: (1) a wavelet detection algorithm to find source candidates and (2) a maximum likelihood PSF fitting algorithm to evaluate the source count rates and the probability that each source candidate is a fluctuation of the background. We discuss the main characteristics of this procedure, which was the result of detailed comparisons between different detection algorithms and photometry tools, calibrated with extensive and dedicated simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of the CUORE detector to 14.4 keV solar axions emitted by the M1 nuclear transition of {sup 57}Fe

In this paper we present a calculation of the sensitivity of the CUORE detector to the monoenergetic 14.4 keV solar axions emitted by the M1 nuclear transition of {sup 57}Fe in the Sun and detected by inverse coherent Bragg-Primakoff conversion in single-crystal TeO{sub 2} bolometers. The expected counting rate is calculated using density functional theory for the electron charge density of TeO{sub 2} and realistic background and energy resolution of CUORE. Monte Carlo simulations for 5y × 741 kg=3705 kg y of exposure are analyzed using time correlation of individual events with the theoretical time-dependent counting rate. We find an expected model-independent limit on the product of the axion-photon coupling and the axion-nucleon coupling g{sub aγγ}g{sub aN}{sup eff} < 1.105 × 10{sup −16} /GeV for axion masses less than 500 eV with 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron radiation-based Mössbauer spectra of {sup 174}Yb measured with internal conversion electrons

A detection system for synchrotron-radiation (SR)-based Mössbauer spectroscopy was developed to enhance the nuclear resonant scattering counting rate and thus increase the available nuclides. In the system, a windowless avalanche photodiode (APD) detector was combined with a vacuum cryostat to detect the internal conversion (IC) electrons and fluorescent X-rays accompanied by nuclear de-excitation. As a feasibility study, the SR-based Mössbauer spectrum using the 76.5 keV level of {sup 174}Yb was observed without {sup 174}Yb enrichment of the samples. The counting rate was five times higher than that of our previous system, and the spectrum was obtained within 10 h. This result shows that nuclear resonance events can be more efficiently detected by counting IC electrons for nuclides with high IC coefficients. Furthermore, the windowless detection system enables us to place the sample closer to the APD elements and is advantageous for nuclear resonant inelastic scattering measurements. Therefore, this detection system can not only increase the number of nuclides accessible in SR-based Mössbauer spectroscopy but also allows the nuclear resonant inelastic scattering measurements of small single crystals or enzymes with dilute probe nuclides that are difficult to measure with the previous detection system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗