Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONGESTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Insufficiency Fractures After Radiation Therapy: An Update

Purpose of Review: Radio therapy, alone or in combination with surgery and/or chemotherapy, is commonly used to treat a variety of neoplasms, resulting in effective local tumor control. Unfortunately radiation therapy can also change the structure of the skeletal system, leading to edema, vascular congestion, areas of hemorrhage, loss of cellularity, focal bone marrow changes, fatty transformation, osteitis, hematopoietic marrow regeneration, osteolysis of symphysis pubis or sacroiliac joints, avascular necrosis, insufficiency fractures, osteoradionecrosis, and radiation-induced neoplasms. Recent Findings: The various radiotherapy effects can be studied and diagnosed by analyzing MR signal intensity, CT attenuation, and FDG-PET activity. Summary: In this review, we report a complete analysis of side effects of radiotherapy on bones, focusing on the spine, chest wall, and pelvis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian modeling framework for crash severity effects of active traffic management systems

Transportation agencies utilize Active traffic management (ATM) systems to dynamically manage recurrent and non-recurrent congestion based on real-time conditions. While these systems have been shown to have some safety benefits, their impact on injury severity outcomes is currently uncertain. In this paper, we used full Bayesian mixed logit models to quantify the impact that ATM deployment had on crash severities. The estimation results revealed lower severities with ATM deployment. Marginal effects for ATM deployments that featured hard shoulder running (HSR) revealed lower likelihoods for severe and moderate injury crashes of 15.9 % and for minor injury crashes of 10.1 %. The likelihood of severe and moderate injury crashes and minor injury crashes reduced by 12.4 % and 8.33 % with ATM without HSR. The models were observed to be temporally transferable and had forecast error of 0.301 and 0.304 for the two models, revealing better performance with validation data. These results have implications for improving freeway crash risk at critical locations.

97 MATHEMATICS AND COMPUTING↗

Analysis and prediction of intersection traffic violations using automated enforcement system data

We report that the automated enforcement system (AES) is an effective way of supplementing traditional traffic enforcement, and the traffic violation data from AES can also be effectively used for safety research. In this study, traffic violation data were used to analyze the influencing factors associated with traffic violations and to predict the probability of violations at intersections. The potential factors influencing violations include 24 independent factors related to time, space, traffic and weather. Results from a logistic model showed that the midday period, weekends, residential districts, collector roads, congested traffic conditions, high traffic flow, lower wind speed and low temperature would increase the probability of traffic violations. The probability of violations was predicted by the random forest algorithm, which was proven to be the best traffic violation prediction model among logistic regression, Gaussian naive Bayes, and support vector machine. Moreover, the proximity weighted synthetic oversampling technique (ProWSyn) method was applied to reduce the impact of the imbalance ratio (IR) and improve the model’s prediction performance. The receiver operating characteristics (ROC) curves and Precision-Recall (PR) curves illustrated that the random forest algorithm using oversampling data had the best classifier prediction performance than undersampling data. The area under curve (AUC) and out-of-bag (OOB) error with IR = 1 reached 0.914 and 0.0787, which showed the better performance of the random forest algorithm using ProWSyn in dealing with imbalanced traffic violation data.

42 ENGINEERING↗

A data-centric weak supervised learning for highway traffic incident detection

Using the data from loop detector sensors for near-real-time detection of traffic incidents on highways is crucial to averting major traffic congestion. While recent supervised machine learning methods offer solutions to incident detection by leveraging human-labeled incident data, the false alarm rate is often too high to be used in practice. Specifically, the inconsistency in the human labeling of the incidents significantly affects the performance of supervised learning models. To that end, we focus on a data-centric approach to improve the accuracy and reduce the false alarm rate of traffic incident detection on highways. We develop a weak supervised learning workflow to generate high-quality training labels for the incident data without the ground truth labels, and we use those generated labels in the supervised learning setup for final detection. This approach comprises three stages. First, we introduce a data preprocessing and curation pipeline that processes traffic sensor data to generate high-quality training data through leveraging labeling functions, which can be domain knowledge-related or simple heuristic rules. Second, we evaluate the training data generated by weak supervision using three supervised learning models-random forest, k-nearest neighbors, and a support vector machine ensemble-and long short-term memory classifiers. The results show that the accuracy of all of the models improves significantly after using the training data generated by weak supervision. Third, we develop an online real-time incident detection approach that leverages the model ensemble and the uncertainty quantification while detecting incidents. Finally, we show that our proposed weak supervised learning workflow achieves a high incident detection rate (0.90) and low false alarm rate (0.08).

97 MATHEMATICS AND COMPUTING↗

Plentiful electricity turns wholesale prices negative

In 2020, average wholesale electricity prices in the United States fell to $21/MWh, their lowest level since the beginning of the 21st century. Low natural gas prices and the proliferation of low marginal cost resources like wind and solar had already established a trend toward lower wholesale prices, and this trend was exacerbated by declining electricity demand due to the Covid-19 pandemic in 2020. Negative real-time hourly wholesale prices occurred in about 4% of all hours and wholesale market nodes across the United States, but these were not distributed evenly. Regional clusters emerged, for example, in the Permian Basin in western Texas, and in Kansas and western Oklahoma in the Southwest Power Pool (SPP), negative prices accounted for more than 25% of all hours. Negative electricity prices result either from local congestion of the transmission system leading supply to exceed demand locally or due to system-wide oversupply. Looking at the latter condition in SPP, we find that all major generator types contribute to this excess supply, because of limited ramping flexibility or self-scheduled out-of-market unit commitments. Additional monetary production incentives such as renewable energy credits or tax credits also enable negative bids; indeed, negative prices predominantly occur when demand levels are low and wind production levels are high. Frequent negative prices can inform the value of additional renewable energy investments at specific locations, the need for transmission and storage development, and opportunities load growth or adaptation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling and simulation of consumer response to dynamic pricing.

Assessing the impacts of dynamic-pricing under the smart grid concept is becoming extremely important for deciding its full deployment. In this paper, we develop a model that represents the response of consumers to dynamic pricing. In the model, consumers use forecasted day-ahead prices to shift daily energy consumption from hours when the price is expected to be high to hours when the price is expected to be low while maintaining the total energy consumption as unchanged. We integrate the consumer response model into the Electricity Market Complex Adaptive System (EMCAS). EMCAS is an agent-based model that simulates restructured electricity markets. We explore the impacts of dynamic-pricing on price spikes, peak demand, consumer energy bills, power supplier profits, and congestion costs. A simulation of an 11-node test network that includes eight generation companies and five aggregated consumers is performed for a period of 1 month. In addition, we simulate the Korean power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive control of fast-acting demand response based on thermostatic loads in real-time retail electricity markets

Coordinated operation of distributed thermostatic loads such as heat pumps and air conditioners can reduce energy costs and prevents grid congestion, while maintaining room temperatures in the comfort range set by consumers. This paper furthers efforts towards enabling thermostatically controlled loads (TCLs) to participate in real-time retail electricity markets under a transactive control paradigm. An agent-based approach is used to develop an effective and low complexity demand response control scheme for TCLs. The proposed scheme adjusts aggregated thermostatic loads according to real-time grid conditions under both heating and cooling modes. Here, a case study is presented showing the method reduces consumer electricity costs by over 10% compared to uncoordinated operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An enhanced SOCP-based method for feeder load balancing using the multi-terminal soft open point in active distribution networks

The integration of distributed generators (DGs) exacerbates the feeder power flow fluctuation and load unbalanced condition in active distribution networks (ADNs). The unbalanced feeder load causes inefficient use of network assets and network congestion during system operation. The flexible interconnection based on the multi-terminal soft open point (SOP) significantly benefits the operation of ADNs. The multi-terminal SOP, which is a controllable power electronic device installed to replace the normally open point, provides accurate active and reactive power flow control to enable the flexible connection of feeders. An enhanced SOCP-based method for feeder load balancing using the multi-terminal SOP is proposed in this paper. Furthermore, by regulating the operation of the multi-terminal SOP, the proposed method can mitigate the unbalanced condition of feeder load and simultaneously reduce the power losses of ADNs. Then, the original non-convex model is converted into a second-order cone programming (SOCP) model using convex relaxation. In order to tighten the SOCP relaxation and improve the computation efficiency, an enhanced SOCP-based approach is developed to solve the proposed model. Finally, case studies are performed on the modified IEEE 33-node system to verify the effectiveness and efficiency of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-traffic coordinated operation for bi-peak shaving and bi-ramp smoothing – A hierarchical data-driven approach

The power distribution system and urban transportation system are two networked system bare their own operation constraints, such peak load in power systems and traffic congestion in transportation system. With the increasing number of electrical vehicles and charging/discharging stations, two systems are become tightly coupled. However, to optimize the two systems target using electrical vehicles as decision control variables cannot be easily solved using a uniformed optimization frame work. Thus we propose a hierarchical optimization approach to address this problem, which consists of a higher and a lower level. In the higher level, the power distribution system and urban transportation system are treated together to minimize the social cost. Meanwhile, the electrical vehicles and the charging/discharging stations are treated as customers to minimize their own expenditures. Then, an equilibrium is designed to determine the optimal charging/discharging price. In the lower level, the models of power distribution system and urban transportation system are developed to provide a detailed analysis. Specifically, in power distribution system, the three-phase unbalanced optimal power flow problem is relaxed with the semidefinite relaxation programming, and solved with alternating direction method of multiplier. A dynamic user equilibrium problem is formulated for the urban transportation system. For electrical vehicles, the state of charge is considered to optimize the charging/discharging schedule and reduce the impacts of power distribution systems. We conducted the simulation and numerical analysis using the IEEE 8500-bus distribution system and the Sioux Falls system with about 10,000 cars. The results demonstrate the feasibility and effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characteristics of locational uncertainty marginal price for correlated uncertainties of variable renewable generation and demands

With the rapid increase of variable renewable energy sources in power systems, how to manage and price the uncertainty of renewable resources’ power outputs is becoming an urgent issue. Current market designs considering the uncertainties are mainly based on the probabilistic scenario set of demand and renewable energy resources power outputs. This consideration makes market designs vulnerable to three significant challenges when put into practice. First, the accurate probability distribution of renewable generation is hard to obtain in real-time. Second, it is challenging to clear the market timely with many scenarios to guarantee accuracy. Third, generation cost recovery cannot be guaranteed for some scenarios. To overcome these challenges, this paper proposes a locational uncertainty marginal price model to price the uncertainty explicitly based on a scenario-free stochastic market-clearing model. Instead of using the probabilistic scenario set, the uncertainty of renewable energy sources and loads is modeled with distributionally-robust chance constraints. The correlation of uncertainties can be endogenously modeled in both the market-clearing and the locational uncertainty marginal price formation. Furthermore, this paper proves that generation cost recovery, revenue adequacy, and partial market equilibrium can be achieved using the locational uncertainty marginal price model. Numerical results from both the small and large systems simulations validate that the generation cost recovery is maintained no matter the generation participates in uncertainty mitigation or not. The transmission congestion surplus is also allocated appropriately among loads, renewable energy sources, and financial transmission right owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Temporal complementarity of marine renewables with wind and solar generation: Implications for GB system benefits

Wave and tidal energy have the potential to provide benefits to power systems with high proportions of stochastic renewable generation. This is particularly applicable with wind and solar photovoltaics, as the offsetting of these renewable resources results in more reliable renewable generation. This study utilises ten metrics to quantify the temporal complementarity and supply-demand balancing requirements of the energy mix in Great Britain, to investigate the potential magnitude of these system benefits. Wave and tidal generation profiles are created using historical resource data and hydrodynamic models. The results show that the inclusion of wave and tidal generation creates a renewable energy mix which is more available under multiple conditions: throughout a year of operation; at times of peak demand; for multiple consecutive hourly time periods; and at times when wind and solar generation are not available. Three regional case studies also show that the inclusion of marine energy allows for improved regional supply-demand matching, reducing instances of energy shortage and excess and potentially relieving transmission congestion at particularly constrained locations within GB. Finally, the implications of these findings are discussed in terms of GB wholesale market operation, system balancing and system security.

16 TIDAL AND WAVE POWER↗

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage↗

Genetic mutations in adipose triglyceride lipase and myocardial up-regulation of peroxisome proliferated activated receptor-γ in patients with triglyceride deposit cardiomyovasculopathy

Highlights: •Triglyceride deposit cardiomyovasculopathy (TGCV) is a rare severe heart disease. •PPARγ is up-regulated in myocardium in patients with TGCV. •Possible vicious cycle for fatty acid may be involved in pathophysiology of TGCV. -- Abstract: Adipose triglyceride lipase (ATGL, also known as PNPLA2) is an essential molecule for hydrolysis of intracellular triglyceride (TG). Genetic ATGL deficiency is a rare multi-systemic neutral lipid storage disease. Information regarding its clinical profile and pathophysiology, particularly for cardiac involvement, is still very limited. A previous middle-aged ATGL-deficient patient in our institute (Case 1) with severe heart failure required cardiac transplantation (CTx) and exhibited a novel phenotype, “Triglyceride deposit cardiomyovasculopathy (TGCV)”. Here, we tried to elucidate molecular mechanism underlying TGCV. The subjects were two cases with TGCV, including our second case who was a 33-year-old male patient (Case 2) with congestive heart failure requiring CTx. Case 2 was homozygous for a point mutation in the 5′ splice donor site of intron 5 in the ATGL, which results in at least two types of mRNAs due to splicing defects. The myocardium of both patients (Cases 1 and 2) showed up-regulation of peroxisome proliferated activated receptors (PPARs), key transcription factors for metabolism of long chain fatty acids (LCFAs), which was in contrast to these molecules’ lower expression in ATGL-targeted mice. We investigated the intracellular metabolism of LCFAs under human ATGL-deficient conditions using patients’ passaged skin fibroblasts as a model. ATGL-deficient cells showed higher uptake and abnormal intracellular transport of LCFA, resulting in massive TG accumulation. We used these findings from cardiac specimens and cell-biological experiments to construct a hypothetical model to clarify the pathophysiology of the human disorder. In patients with TGCV, even when hydrolysis of intracellular TG is defective, the marked up-regulation of PPARγ and related genes may lead to increased uptake of LCFAs, the substrates for TG synthesis. This potentially vicious cycle of LCFAs could explain the massive accumulation of TG and severe clinical course for this rare disease.

60 APPLIED LIFE SCIENCES↗

PPARγ partial agonist GQ-16 strongly represses a subset of genes in 3T3-L1 adipocytes

Thiazolidinediones (TZDs) are peroxisome proliferator-activated receptor gamma (PPARγ) agonists that improve insulin resistance but trigger side effects such as weight gain, edema, congestive heart failure and bone loss. GQ-16 is a PPARγ partial agonist that improves glucose tolerance and insulin sensitivity in mouse models of obesity and diabetes without inducing weight gain or edema. It is not clear whether GQ-16 acts as a partial agonist at all PPARγ target genes, or whether it displays gene-selective actions. To determine how GQ-16 influences PPARγ activity on a gene by gene basis, we compared effects of rosiglitazone (Rosi) and GQ-16 in mature 3T3-L1 adipocytes using microarray and qRT-PCR. Rosi changed expression of 1156 genes in 3T3-L1, but GQ-16 only changed 89 genes. GQ-16 generally showed weak effects upon Rosi induced genes, consistent with partial agonist actions, but a subset of modestly Rosi induced and strongly repressed genes displayed disproportionately strong GQ-16 responses. PPARγ partial agonists MLR24 and SR1664 also exhibit disproportionately strong effects on transcriptional repression. We conclude that GQ-16 displays a continuum of weak partial agonist effects but efficiently represses some negatively regulated PPARγ responsive genes. Strong repressive effects could contribute to physiologic actions of GQ-16. - Highlights: • GQ-16 is an insulin sensitizing PPARγ ligand with reduced harmful side effects. • GQ-16 displays a continuum of weak partial agonist activities at PPARγ-induced genes. • GQ-16 exerts strong repressive effects at a subset of genes. • These inhibitor actions should be evaluated in models of adipose tissue inflammation.

60 APPLIED LIFE SCIENCES↗

Carvedilol suppresses cartilage matrix destruction

Collagen type Ⅱ (col Ⅱ) and aggrecan, the main components of the extracellular matrix (ECM) in human joint cartilage, have been reported to be reduced by chronic production of inflammatory cytokine interleukin (IL)-1β in arthritic joints. Carvedilol, a licensed medicine, has been used for treatment of hypertension, congestive heart failure and coronary disease in clinics. In this study, we investigated the effects of Carvedilol on the expression of col Ⅱ and aggrecan. Our results demonstrate that treatment with Carvedilol didn't change the expression of aggrecan or col Ⅱ at mRNA levels in SW1353 chondrocytes. However, the expression of aggrecan and Col II at protein levels were significantly reduced by IL-1β treatment, which were reversed by Carvedilol in a dose dependent manner, suggesting the inhibitory effects of Carvedilol on the expression of aggrecan and Col II are at post-translational modification levels. In addition, it was shown that IL-1β treatment highly induced MMP-1 and MMP-13 expression in SW1353 chondrocytes at both gene and protein expression levels, which were restored by Carvedilol in a dose dependent manner. Mechanistically, exposure to IL-1β increased phosphorylation of IKK-α/β and degradation of IκB-α in SW1353 chondrocytes, which were suppressed by pretreatment with Carvedilol. Administration of Carvedilol inhibited IL-1β-induced translocation of NF-κB p65 from cytosol to nucleus manner. Notably, a luciferase reporter assay showed that IL-1β severely increased NF-κB luciferase activity, which was markedly suppressed by Carvedilol treatment. Our results suggest that Carvedilol might be a potential therapeutic agent for chondro-protective therapy. - Highlights: • Carvedilol abolishes IL-1β induced degradation of col Ⅱ and aggrecan. • Carvedilol inhibits the expression of MMP-1 and MMP-3 induced by IL-1β. • Carvedilol attenuates phosphorylation of IKK-α/β and degradation of IκB-α. • Carvedilol inhibits nuclear translocation of p65 and NF-κB luciferase activity.

60 APPLIED LIFE SCIENCES↗

Cyclosporine A exhibits gender-specific nephrotoxicity in rats: Effect on renal tissue inflammation

Cyclosporine A (CSA) is a widely used immunosuppressant drug known to commonly cause cardio and nephrotoxicity. A study looking at the sex specificity of the cardiotoxicity of CSA revealed that sexual dimorphism existed when looking at the electrocardiographs and left ventricles of CSA-treated rats. We hypothesized that cyclosporine A exhibited gender-specific nephrotoxicity by testing various parameters of kidney function in male and female rats treated for 21 days with 15 mg/kg CSA versus control male and female rats that received a vehicle consisting of 18% kolliphore and 2% ethanol in sterile saline. It was found that male rats treated with CSA had significantly higher levels of serum creatinine and lower creatinine clearance than control males. However, serum creatinine and creatinine clearance were not affected by CSA treatment in females. Histopathological examination of kidney cross-sections revealed a heavy aggregation of inflammatory cells and significant vascular congestion in males treated with CSA, which was less prominent in female rats receiving CSA. In addition CSA treated male rats had higher levels of serum cholesterol compared with control while, CSA did not affect serum cholesterol in female rats. Kidney tumor necrosis factor alpha (TNF-α) levels were found to drop in female rats following CSA treatment, whereas no change was observed in male rats before and after treatment. These results suggest that CSA exhibits gender-related nephrotoxicity in rats that might be mediated by differences in the inflammatory response between males and females.

60 APPLIED LIFE SCIENCES↗