Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARISON SOFTWARE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SU-E-T-341: DVH-Based Comparison of True 3D Measurements to a Delta4 System

Purpose: Delta4 dosimetric software can be used to calculate DVH-based metrics for patient-specific quality assurance from measurements made by a Delta4 QA device. This study investigates the effectiveness of a novel transform method that transposes measurements made with a full-density 3D dosimeter onto patient anatomy, enabling the calculation of DVHs. This allows for DVH comparisons from the transformed dose distribution, which are based on true 3D measurements, to those from the Delta4 system, which are based on semi-3D measurements and interpolation. Methods: A double-arc VMAT treatment for a head-and-neck case was delivered to a 1kg PRESAGE 3D dosimeter inserted into a polyurethane head phantom. The dosimeter was readout using an in-house optical-CT scanner to gather full-density 3D dosimetric data. The transform method is achieved by multiplication of the measured doses with a “transformation matrix” which accounts for heterogeneities and differences in geometry between the patient and the phantom. The transformation matrix is a voxel-by-voxel division of the patient planned dose by the phantom planned dose, both calculated in the treatment planning system (Eclipse). The transformed distribution was then overlaid on the patient CT data, enabling the calculation of DVHs. The same VMAT treatment was delivered to the Delta4 phantom and DVH data was calculated using its associated software. Results: The transformed dose distribution showed good agreement with calculated patient values, determined by similarity in dose profiles between the two distributions and a 3D gamma index passing rate of 94.87% for 3%/3mm criteria. For every structure contained within the dosimeter volume, the transformed DVHs demonstrated better agreement than the Delta4 DVHs, when compared to the values calculated in the treatment planning system. Conclusion: The coupled technique of full-density 3D dose measurements and the presented transform method enables clinical patient-specific quality assurance data that is more accurate than the semi-3D Delta4 system. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

A Method for Assessing the Accuracy of a Photogrammetry System for Precision Deployable Structures

The measurement techniques used to validate analytical models of large deployable structures are an integral Part of the technology development process and must be precise and accurate. Photogrammetry and videogrammetry are viable, accurate, and unobtrusive methods for measuring such large Structures. Photogrammetry uses Software to determine the three-dimensional position of a target using camera images. Videogrammetry is based on the same principle, except a series of timed images are analyzed. This work addresses the accuracy of a digital photogrammetry system used for measurement of large, deployable space structures at JPL. First, photogrammetry tests are performed on a precision space truss test article, and the images are processed using Photomodeler software. The accuracy of the Photomodeler results is determined through, comparison with measurements of the test article taken by an external testing group using the VSTARS photogrammetry system. These two measurements are then compared with Australis photogrammetry software that simulates a measurement test to predict its accuracy. The software is then used to study how particular factors, such as camera resolution and placement, affect the system accuracy to help design the setup for the videogrammetry system that will offer the highest level of accuracy for measurement of deploying structures.

Moore, Ashley↗

Software Tools to Support the Assessment of System Health

This presentation provides an overview of three software tools that were developed by the NASA Glenn Research Center to support the assessment of system health: the Propulsion Diagnostic Method Evaluation Strategy (ProDIMES), the Systematic Sensor Selection Strategy (S4), and the Extended Testability Analysis (ETA) tool. Originally developed to support specific NASA projects in aeronautics and space, these software tools are currently available to U.S. citizens through the NASA Glenn Software Catalog. The ProDiMES software tool was developed to support a uniform comparison of propulsion gas path diagnostic methods. Methods published in the open literature are typically applied to dissimilar platforms with different levels of complexity. They often address different diagnostic problems and use inconsistent metrics for evaluating performance. As a result, it is difficult to perform a one ]to ]one comparison of the various diagnostic methods. ProDIMES solves this problem by serving as a theme problem to aid in propulsion gas path diagnostic technology development and evaluation. The overall goal is to provide a tool that will serve as an industry standard, and will truly facilitate the development and evaluation of significant Engine Health Management (EHM) capabilities. ProDiMES has been developed under a collaborative project of The Technical Cooperation Program (TTCP) based on feedback provided by individuals within the aircraft engine health management community. The S4 software tool provides a framework that supports the optimal selection of sensors for health management assessments. S4 is structured to accommodate user ]defined applications, diagnostic systems, search techniques, and system requirements/constraints. One or more sensor suites that maximize this performance while meeting other user ]defined system requirements that are presumed to exist. S4 provides a systematic approach for evaluating combinations of sensors to determine the set or sets of sensors that optimally meet the performance goals and the constraints. It identifies optimal sensor suite solutions by utilizing a merit (i.e., cost) function with one of several available optimization approaches. As part of its analysis, S4 can expose fault conditions that are difficult to diagnose due to an incomplete diagnostic philosophy and/or a lack of sensors. S4 was originally developed and applied to liquid rocket engines. It was subsequently used to study the optimized selection of sensors for a simulation ]based aircraft engine diagnostic system. The ETA Tool is a software ]based analysis tool that augments the testability analysis and reporting capabilities of a commercial ]off ]the ]shelf (COTS) package. An initial diagnostic assessment is performed by the COTS software using a user ]developed, qualitative, directed ]graph model of the system being analyzed. The ETA Tool accesses system design information captured within the model and the associated testability analysis output to create a series of six reports for various system engineering needs. These reports are highlighted in the presentation. The ETA Tool was developed by NASA to support the verification of fault management requirements early in the Launch Vehicle process. Due to their early development during the design process, the TEAMS ]based diagnostic model and the ETA Tool were able to positively influence the system design by highlighting gaps in failure detection, fault isolation, and failure recovery.

Melcher, Kevin J.↗

Development of an Automated J-R Curve Analysis Software Based on the ASTM E1820-18 Normalization Method

The J-integral versus crack-growth resistance curve (J-R curve) is a useful tool for evaluating material fracture toughness in the ductile region. A widely accepted practice for conducting J-R curve testing is ASTM standard E1820, which introduces the normalization method. This method does not require compliance measurements during testing, significantly simplifying J-R curve testing compared with the conventional elastic unloading compliance (EUC) method. Despite the advantage in testing, analysis procedures for the normalization method are very complicated. Also, there is no open source software currently available to perform such analysis.The authors developed an open source automated J-R curve-analysis software based on the normalization method in ASTM E1820-18. Source codes were written in MATLAB and the compiled software, in the form of a stand-alone executable, has a user-friendly graphic interface and is readily compatible with modern Windows operating systems. Both source codes and the compiled executable file are available for download at https://code.ornl.gov/xc8/ANJR.git. Comparisons between resulting J-R curves from the software and manual analysis procedures show essentially identical results, indicating the suitability of applying the automated software for J-R curve analysis.

36 MATERIALS SCIENCE↗

FUN3D Analyses in Support of the 1st AIAA Stability and Control Prediction Workshop

The 1st AIAA Stability and Control Prediction Workshop was created to establish best practices for the prediction of stability & control derivatives using computational fluid dynamics and assess the limitations of these computational methods when those best practices are applied. The inaugural workshop considers the ONERA version of the NASA/Boeing Common Research Model(CRM), which includes the wing, body, horizontal tail, and a vertical tail designed by ONERA. Wind tunnel tests have been conducted for this configuration with longitudinal tests having been previously published, in addition to unpublished data at small sideslip angles that will serve as ‘blind’ data for workshop data comparisons. Participants were provided a ‘family’ of unstructured grids for the full-span ONERA CRM model with the wind-tunnel sting included. This family of mixed-element grids consists of 5 levels of refinement (tiny, coarse, medium, fine, and extra fine) with surface and volume mesh scaling, resulting in a size range of 14.6 to 53.4 million nodes. In addition, a medium refinement mesh has been provided for the ONERA CRM configuration without a sting to evaluate the sting’s impact on static longitudinal stability characteristics. In addition to these workshop-provided grids, the present work also considers an equivalent ‘family’ of computational grids generated using Heldenmesh™, a rapid grid generation software by Helden Aerospace Corporation for creating high-quality, three-dimensional, mixed-element unstructured meshes. Because of the authors’ familiarity with this software, these additional grids were generated as a comparison to the workshop-provided grids and to better understand the implications of using volume-mirrored grids for stability and control predictions. The present work will contribute to the workshop with test case data generated using the NASA FUN3D code, a parallelized, unstructured, node-based, finite-volume discretization, Reynolds-averaged Navier-Stokes flow solver. Numerical simulations will be conducted using the Quadratic Constitutive Relationship (QCR) version of the Spalart-Allmaras (SA) turbulence model with negative turbulence variable provisions. Both steady and2nd-order, time-accurate simulation results are to be generated and compared for select test cases, as time permits, to investigate their impact on FUN3D predictions. The present work will consider the three primary workshop test cases: (1) grid convergence study, (2) Mach number effect on static stability, and (3) wind tunnel sting increments. Additionally, data will be provided for the two optional test cases, which include:(1) static stability derivative calculations and (2)sideslip angle sweeps. In each of the test cases, the vehicle is stationary, and the body is assumed to be rigid, where vehicle deformation has been accounted for in the model configuration geometry. For all test cases, longitudinal and lateral force and moment aerodynamic coefficients will be provided for the total configuration, in addition to a component-level breakdown that includes the port wing, starboard wing, fuselage, and tail.

CFD↗

The Satellite Flythrough and Reconstruction Softwares at CCMC

The next-generation of model data visualization to be offered at the Community Coordinated Modeling Center (CCMC) will be based on Kamodo, an open source python package. To increase the usefulness of our services, we are also developing new capabilities based on this software, called the satellite flythrough and the reconstruction tools, to be offered both as packages for offline analysis and through an online interface (coming soon). The satellite flythrough software ‘flies’ a satellite trajectory, whether real or imaginary, through either model data hosted at CCMC or on a personal machine. This service greatly simplifies the complexity of users’ access to model data, abstracting away the time-consuming details of model data formats and interpolation. We demonstrate execution times of a few seconds to a few minutes for several example flythroughs of a trajectory stretching over a few days, depending on the parameters chosen. We also demonstrate a reconstruction tool built on top of the satellite flythrough software, for use with mission planning and model-data comparisons. This tool, based on reconstructions provided for the GDC Science and Technology Definition Team, converts multiple, simultaneous satellite flythroughs into two-dimensional reconstructions. The reconstruction tool provides a software capability for satellite constellations to determine how many satellites are needed and in what configuration to resolve the desired features in the model data. Both tools are currently available through GitHub for a selection of CCMC-hosted ITM models. Finally, we present initial results from work in progress and plans for future work, including an expansion of the reconstruction tool to provide 3D reconstruction capabilities and a line-of-sight calculation tool.

software, python↗

Global Precipitation Mission Visualization Tool

The Global Precipitation Mission (GPM) software provides graphic visualization tools that enable easy comparison of ground- and space-based radar observations. It was initially designed to compare ground radar reflectivity from operational, ground-based, S- and C-band meteorological radars with comparable measurements from the Tropical Rainfall Measuring Mission (TRMM) satellite's precipitation radar instrument. This design is also applicable to other groundbased and space-based radars, and allows both ground- and space-based radar data to be compared for validation purposes. The tool creates an operational system that routinely performs several steps. It ingests satellite radar data (precipitation radar data from TRMM) and groundbased meteorological radar data from a number of sources. Principally, the ground radar data comes from national networks of weather radars (see figure). The data ingested by the visualization tool must conform to the data formats used in GPM Validation Network Geometry-matched data product generation. The software also performs match-ups of the radar volume data for the ground- and space-based data, as well as statistical and graphical analysis (including two-dimensional graphical displays) on the match-up data. The visualization tool software is written in IDL, and can be operated either in the IDL development environment or as a stand-alone executable function.

Schwaller, Mathew↗

Impact Study of Metal Fasteners in Roofing Assemblies using Three-Dimensional Heat Transfer Analysis

Heat transfer analysis was performed on typical roofing assemblies using HEAT3, a three-dimensional heat transfer analysis software. The difference in heat transferred through the roofing assemblies considered is compared between two cases - without any steel fasteners and with steel fasteners. In the latter case, the metal roofing fasteners were arranged as per Factor Mutual Global (FMG) approvals, in the field, perimeter, and corner zones of the roof. The temperature conditions used for the analysis represented summer and winter conditions for three separate Climate Zones (CZ) namely Climate Zone 2 or CZ2 represented by Orlando, FL; CZ3 represented by Atlanta, GA; and CZ6 zone represented by St. Paul, MN. In all the climatic conditions, higher energy transfer was observed with increase in the number of metal fasteners attributed to high thermal conductivity of metals as compared to the insulation and other materials used in the roofing assembly. This difference in heat loss was also quantified in the form of percentage change in the overall or effective insulation of the roofing assembly for better understanding of the practical aspects. Besides, a comparison of 2D heat transfer analysis (using THERM software) and 3D analysis using HEAT3 is also discussed.

3D modeling↗

Advanced statistical methods for improved data analysis of NASA astrophysics missions

The investigators under this grant studied ways to improve the statistical analysis of astronomical data. They looked at existing techniques, the development of new techniques, and the production and distribution of specialized software to the astronomical community. Abstracts of nine papers that were produced are included, as well as brief descriptions of four software packages. The articles that are abstracted discuss analytical and Monte Carlo comparisons of six different linear least squares fits, a (second) paper on linear regression in astronomy, two reviews of public domain software for the astronomer, subsample and half-sample methods for estimating sampling distributions, a nonparametric estimation of survival functions under dependent competing risks, censoring in astronomical data due to nondetections, an astronomy survival analysis computer package called ASURV, and improving the statistical methodology of astronomical data analysis.

Feigelson, Eric D.↗

SU-E-T-36: A GPU-Accelerated Monte-Carlo Dose Calculation Platform and Its Application Toward Validating a ViewRay Beam Model

Purpose: To build a fast, accurate and easily-deployable research platform for Monte-Carlo dose calculations. We port the dose calculation engine PENELOPE to C++, and accelerate calculations using GPU acceleration. Simulations of a Co-60 beam model provided by ViewRay demonstrate the capabilities of the platform. Methods: We built software that incorporates a beam model interface, CT-phantom model, GPU-accelerated PENELOPE engine, and GUI front-end. We rewrote the PENELOPE kernel in C++ (from Fortran) and accelerated the code on a GPU. We seamlessly integrated a Co-60 beam model (obtained from ViewRay) into our platform. Simulations of various field sizes and SSDs using a homogeneous water phantom generated PDDs, dose profiles, and output factors that were compared to experiment data. Results: With GPU acceleration using a dated graphics card (Nvidia Tesla C2050), a highly accurate simulation – including 100*100*100 grid, 3×3×3 mm3 voxels, <1% uncertainty, and 4.2×4.2 cm2 field size – runs 24 times faster (20 minutes versus 8 hours) than when parallelizing on 8 threads across a new CPU (Intel i7-4770). Simulated PDDs, profiles and output ratios for the commercial system agree well with experiment data measured using radiographic film or ionization chamber. Based on our analysis, this beam model is precise enough for general applications. Conclusions: Using a beam model for a Co-60 system provided by ViewRay, we evaluate a dose calculation platform that we developed. Comparison to measurements demonstrates the promise of our software for use as a research platform for dose calculations, with applications including quality assurance and treatment plan verification.

60 APPLIED LIFE SCIENCES↗

Validation and Comparison of HyRAM Physics Models

The Hydrogen Risk Assessment Models (HyRAM) software version 3 uses a real gas equation of state rather than the Abel-Noble equation of state that is used in 2.0 and previous versions. This change enables the use of HyRAM 3 for cryogenic hydrogen flows, whereas the Abel-Noble equation of state is not accurate at low temperatures. HyRAM 3.1 results were compared to experimental data from the literature in order to demonstrate the accuracy of the physics models. HyRAM 3.1 results were also compared to HyRAM 2.0 for high-pressure, non-cryogenic flows to highlight the differences in predictions between the two major versions of HyRAM. Validation data sets are from multiple groups and span the range of HyRAM physics models, including tank blowdown, unignited dispersion jet plume, ignited jet flame, and accumulation and overpressure inside an enclosure. Both versions 2.0 and 3.1 of HyRAM are accurate for predictions of blowdowns, diffusion jets, and diffusion flames of hydrogen at pressures up to 900 bar, and HyRAM 3.1 also shows good agreement with cryogenic hydrogen data. Overall, HyRAM 3.1 improves on the accuracy of the physical models relative to HyRAM 2.0. In most cases, this reduces the conservatism in risk calculations using HyRAM.

08 HYDROGEN↗

Mass spectrometric investigations on the release of inorganic species during gasification and combustion of German hard coals

Na-, K-, Cl-, and S-species released during thermal conversion of coal can cause several problems such as fouling, slagging and corrosion, especially in gas turbines and heat recovery systems. To reduce this problems an enhanced understanding of the underlying release mechanisms for Na-, K-, Cl-, and S-species is needed. Therefore, basic investigations have been performed in an atmospheric lab-scale tube furnace at 1400 C under gasification and combustion conditions. Hot gas analysis has been carried out by molecular beam mass spectrometry. The release of H{sub 2}S, HCl, K+, NaCl, COS, and SO{sub 2} has been qualitative and quantitative analysed and correlated with the coal composition. The results show a strong dependence of coal composition and reaction atmosphere on the release of Na-, K-, Cl-, and S-species. Additionally, thermodynamic equilibrium calculations with the software package FactSage 5.4.1 have been undertaken for comparison with the experimental results. (author)

01 COAL, LIGNITE, AND PEAT↗

Variations in the Contouring of Organs at Risk: Test Case From a Patient With Oropharyngeal Cancer

Purpose: Anatomy contouring is critical in radiation therapy. Inaccuracy and variation in defining critical volumes will affect everything downstream: treatment planning, dose-volume histogram analysis, and contour-based visual guidance used in image-guided radiation therapy. This study quantified: (1) variation in the contouring of organs at risk (OAR) in a clinical test case and (2) corresponding effects on dosimetric metrics of highly conformal plans. Methods and Materials: A common CT data set with predefined targets from a patient with oropharyngeal cancer was provided to a population of clinics, which were asked to (1) contour OARs and (2) design an intensity-modulated radiation therapy plan. Thirty-two acceptable plans were submitted as DICOM RT data sets, each generated by a different clinical team. Using those data sets, we quantified: (1) the OAR contouring variation and (2) the impact this variation has on dosimetric metrics. New technologies were employed, including a software tool to quantify three-dimensional structure comparisons. Results: There was significant interclinician variation in OAR contouring. The degree of variation is organ-dependent. We found substantial dose differences resulting strictly from contouring variation (differences ranging from -289% to 56% for mean OAR dose; -22% to 35% for maximum dose). However, there appears to be a threshold in the OAR comparison metric beyond which the dose differences stabilize. Conclusions: The effects of interclinician variation in contouring organs-at-risk in the head and neck can be large and are organ-specific. Physicians need to be aware of the effect that variation in OAR contouring can play on the final treatment plan and not restrict their focus only to the target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the mirror instability in the presence of electron temperature anisotropy

Computation of the mirror instability growth rate in an ion-electron bi-Maxwellian plasma is revisited, starting from the low-frequency kinetic theory. The role of the electron finite Larmor radius (FLR) effects on the instability quenching is shown to possibly be dominant, even near threshold where the smallest unstable scales significantly exceed the electron gyroscale. Validation of the results by comparison with predictions of the fully kinetic whamp software is also presented. The influence of the electron temperatures on the ion FLR effects very near threshold, where the electron kinetic effects are negligible, is also pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Semi-empirical device model for Cu{sub 2}ZnSn(S,Se){sub 4} solar cells

We present a device model for the hydrazine processed kesterite Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe) solar cell with a world record efficiency of ∼12.6%. Detailed comparison of the simulation results, performed using wxAMPS software, to the measured device parameters shows that our model captures the vast majority of experimental observations, including V{sub OC}, J{sub SC}, FF, and efficiency under normal operating conditions, and temperature vs. V{sub OC}, sun intensity vs. V{sub OC}, and quantum efficiency. Moreover, our model is consistent with material properties derived from various techniques. Interestingly, this model does not have any interface defects/states, suggesting that all the experimentally observed features can be accounted for by the bulk properties of CZTSSe. An electrical (mobility) gap that is smaller than the optical gap is critical to fit the V{sub OC} data. These findings point to the importance of tail states in CZTSSe solar cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards in-situ high precision local material velocity measurements in lattice materials under dynamic compression

The study of dynamic compression of materials requires high precision spatial and temporal resolution to infer the material state at any given time. In ultra-fast imaging experiments such as those performed at the Dynamic Compression Sector at the Advanced Photon Source, the current CCD frame rate is less than the X-ray pulse rate necessitating that 4 CCDs be used to image a single scintillator screen to obtain the same projection of transmitted or diffracted beam at time intervals synchronized with the X-ray beam. The use of multiple-camera setups is often employed for a variety of reasons including enhancing the temporal resolution through interleaving frames or increasing the number of viewpoints, for example. Physical corrections are made to have each CCD approximately viewing the same field of view, however we present corrections that can be made after the data collection to further refine and be able to compare movements and changes in the sample between independent CCDs. These software corrections enable higher precision and higher fidelity comparison of position changes due to sample deformation. Furthermore, we present a method to correct images (or frames) as a demonstration toward high fidelity displacement measurements in these types of ultra-fast multi-camera setup experiments.

36 MATERIALS SCIENCE↗

Experimental determination of the radial dose distribution in high gradient regions around {sup 192}Ir wires: Comparison of electron paramagnetic resonance imaging, films, and Monte Carlo simulations

Purpose: The experimental determination of doses at proximal distances from radioactive sources is difficult because of the steepness of the dose gradient. The goal of this study was to determine the relative radial dose distribution for a low dose rate {sup 192}Ir wire source using electron paramagnetic resonance imaging (EPRI) and to compare the results to those obtained using Gafchromic EBT film dosimetry and Monte Carlo (MC) simulations. Methods: Lithium formate and ammonium formate were chosen as the EPR dosimetric materials and were used to form cylindrical phantoms. The dose distribution of the stable radiation-induced free radicals in the lithium formate and ammonium formate phantoms was assessed by EPRI. EBT films were also inserted inside in ammonium formate phantoms for comparison. MC simulation was performed using the MCNP4C2 software code. Results: The radical signal in irradiated ammonium formate is contained in a single narrow EPR line, with an EPR peak-to-peak linewidth narrower than that of lithium formate ({approx}0.64 and 1.4 mT, respectively). The spatial resolution of EPR images was enhanced by a factor of 2.3 using ammonium formate compared to lithium formate because its linewidth is about 0.75 mT narrower than that of lithium formate. The EPRI results were consistent to within 1% with those of Gafchromic EBT films and MC simulations at distances from 1.0 to 2.9 mm. The radial dose values obtained by EPRI were about 4% lower at distances from 2.9 to 4.0 mm than those determined by MC simulation and EBT film dosimetry. Conclusions: Ammonium formate is a suitable material under certain conditions for use in brachytherapy dosimetry using EPRI. In this study, the authors demonstrated that the EPRI technique allows the estimation of the relative radial dose distribution at short distances for a {sup 192}Ir wire source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗