Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

THE CARNEGIE HUBBLE PROGRAM: THE LEAVITT LAW AT 3.6 AND 4.5 {mu}m IN THE MILKY WAY

The Carnegie Hubble Program (CHP) is designed to calibrate the extragalactic distance scale using data from the post-cryogenic era of the Spitzer Space Telescope. The ultimate goal of the CHP is a systematic improvement in the distance scale leading to a determination of the Hubble constant to within an accuracy of 2%. This paper focuses on the measurement and calibration of the Galactic Cepheid period-luminosity (PL, Leavitt) relation using the warm Spitzer/IRAC 1 and 2 bands at 3.6 and 4.5 {mu}m. We present photometric measurements covering the period range 4-70 days for 37 Galactic Cepheids. Data at 24 phase points were collected for each star. Three PL relations of the form M = a(log (P) - 1) + b are derived. The method adopted here takes the slope a to be -3.31, as determined from the Spitzer Large Magellanic Cloud (LMC) data of Scowcroft et al. Using the geometric Hubble Space Telescope guide-star distances to 10 Galactic Cepheids, we find a calibrated 3.6 {mu}m PL zero point of -5.80 {+-} 0.03. Together with our value for the LMC zero point, we determine a reddening-corrected distance modulus of 18.48 {+-} 0.04 mag to the LMC. The mid-IR period-color diagram and the [3.6]-[4.5] color variation with phase are interpreted in terms of CO absorption at 4.5 {mu}m. This situation compromises the use of the 4.5 {mu}m data for distance determinations.

79 ASTRONOMY AND ASTROPHYSICS↗

Net Zero Energy Model for Wastewater Treatment Plants

The primary objective of this study is to achieve net-zero energy (NZE) wastewater treatment plants (WWTPs) by utilizing energy efficiency opportunities (EEO), combined heat and power (CHP) systems, and other renewable energy (RE) sources, e.g., solar, water, and wind powers. Herein, this study discusses an innovative energy solution for WWTPs in the United States, and one of the WWTPs with a flow capacity of 1.5 million gallons per day (MGD) was selected as a case study. An optimization tool, Hybrid Optimization of Multiple Energy Resources (HOMER) software, is used in this study to find the best energy system configuration to run the system. An energy audit for one WWTP was conducted in early 2020 and the report is used to do this study. The proposed EEOs were able to reduce WWTP energy consumption by about 11%. The excess anaerobic digester gas was utilized in a CHP system to cover about 42% of the facility’s consumption. Also, 3% of the utility energy consumption can be claimed by microturbines in the aeration tanks. Another two renewable energy systems, solar photovoltaic (PV) with 29% and water turbines with 15%, contribute to covering 100% of the WWTP energy consumption and achieving an NZE WWTP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

VOLTTRON/econ-dispatch

Work space for in development Economic Dispatch Application. Multi-purpose open-source control algorithms that will ensure real-time optimal operation, increase electric grid reliability, and lead to the goal of clean, efficient, reliable and affordable next generation building-integrated combine cooling, heating and power (CHP) system.The CHP system could include conventional heating, ventilation, air conditioning (HVAC) systems, distributed generation (DG), local storage (both thermal and electric) and local solar photovoltaic (PV) systems.

Katipamula, Srinivas↗

Geothermal Play Fairway Analysis for Low-Temperature Resources in the Denver Basin

This dataset is part of an effort to highlight the advantages of incorporating low-temperature (< 150 C) geothermal resource evaluation into the implementation of combined heat and power (CHP), and geothermal direct use (GDU) technologies (e.g., space heating and/or cooling). For this Denver Basin example, resource favorability maps were created to identify potentially favorable areas for further geothermal exploration and are provided here. Favorability was based on three types of data: (1) geologic, (2) economic, and (3) risk. This raw data is also provided below. Geologic data include bottom-hole temperatures (BHT) from oil and gas wells, water co-production volumes from oil and gas wells, well groundwater levels, hot spring locations, temperatures, and chemistries, faults, and earthquakes. Economic feasibility data include population, thermal energy demand, infrastructure, and roads. Risk data (which includes data on excluded areas) include flood plains, protected lands (e.g. wildlife conservation areas, national parks). The included report describes this project in detail, covering workflows, relevant datasets, Python code, and both common and composite maps used to create low-temperature geothermal resource favorability maps for the Denver Basin, which extends across Colorado, Nebraska, and Wyoming. The figures in this report include: maps of the original datasets; maps of transformed data and derived parameters (such as the geothermal gradient or thermal conductivity); results of uncertainty analyses; results of data completeness (using the GeoRePORT tool); examples of the data combination and processing (using the geoPFA Python library, which is introduced in the attached report); favorability maps for each criteria; and a final combined favorability map. This project is designed to facilitate future deployment of CHP and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources in sedimentary basins.

15 GEOTHERMAL ENERGY↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DESCRIPTION OF ACTIVITIES AND SELECTED RESULTS FOR THE U.S. DEPARTMENT OF ENERGY S CLEAN ENERGY APPLICATION CENTERS: FISCAL YEAR 2010

The U.S. Department of Energy (DOE) sponsors a set of Clean Energy Application Centers that promote the development and deployment of clean energy technologies. There are eight regional centers that provide assistance for specific areas of the country plus a separate center operated by the International District Energy Association that provides technical assistance on district energy issues and applications to the regional centers. The original focus of the centers was on combined heat and power (CHP) alone but, beginning in fiscal year 2010, their scope expanded to include district energy systems and waste heat recovery. At that time, the official name of the centers changed from CHP Regional Application Centers (RACs) to Clean Energy Application Centers, and their number was expanded to include the previously-mentioned center focusing on district energy. Oak Ridge National Laboratory (ORNL) has performed two previous studies of RAC activities. The first one examined what the RACs had done each year from the initiation of the program through fiscal year (FY) 2008 and the second one examined RAC activities for the 2009 fiscal year. The most recent study, described in this report, examines what was accomplished in fiscal year 2010, the first year since the RACs expanded their focus and changed their name to Clean Energy Application Centers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Combined Heat and Power: Enabling Resilient Energy Infrastructure for Critical Facilities

Critical infrastructure (CI) collectively refers to those assets, systems, and networks that, if incapacitated, would have a substantial negative impact on national or regional security, economic operations, or public health and safety. Combined heat and power (CHP) offers the opportunity to improve CI resiliency, mitigating the impacts of an emergency by keeping critical facilities running without any interruption in electric or thermal service. If the electricity grid is impaired, a specially configured CHP system can continue to operate, ensuring an uninterrupted supply of power and heating or cooling to the host facility.

Hampson, Anne↗

Northwest Region Clean Energy Application Center

The main objective of the Northwest Clean Energy Application Center (NW CEAC) is to promote and support implementation of clean energy technologies. These technologies include combined heat and power (CHP), district energy, waste heat recovery with a primary focus on waste heat to power, and other related clean energy systems such as stationary fuel cell CHP systems. The northwest states include AK, ID, MT, OR, and WA. The key aim/outcome of the Center is to promote and support implementation of clean energy projects. Implemented projects result in a number of benefits including increased energy efficiency, renewable energy development (when using opportunity fuels), reduced carbon emissions, improved facility economics helping to preserve jobs, and reduced criteria pollutants calculated on an output-based emissions basis. Specific objectives performed by the NW CEAC fall within the following five broad promotion and support categories: 1) Center management and planning including database support; 2) Education and Outreach including plan development, website, target market workshops, and education/outreach materials development 3) Identification and provision of screening assessments & feasibility studies as funded by the facility or occasionally further support of Potential High Impact Projects; 4) Project implementation assistance/trouble shooting; and 5) Development of a supportive clean energy policy and initiative/financing framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Total Cost of Ownership Model for Low Temperature PEM Fuel Cells in Combined Heat and Power and Backup Power Applications

A total cost of ownership model is described for low temperature proton exchange membrane stationary fuel cell systems for combined heat and power (CHP) applications from 1-250kW and backup power applications from 1-50kW. System designs and functional specifications for these two applications were developed across the range of system power levels. Bottom-up cost estimates were made for balance of plant costs, and detailed direct cost estimates for key fuel cell stack components were derived using design-for-manufacturing-and-assembly techniques. The development of high throughput, automated processes achieving high yield are projected to reduce the cost for fuel cell stacks to the $300/kW level at an annual production volume of 100 MW. Several promising combinations of building types and geographical location in the U.S. were identified for installation of fuel cell CHP systems based on the LBNL modelling tool DER CAM. Life-cycle modelling and externality assessment were done for hotels and hospitals. Reduced electricity demand charges, heating credits and carbon credits can reduce the effective cost of electricity ($/kWhe) by 26-44percent in locations such as Minneapolis, where high carbon intensity electricity from the grid is displaces by a fuel cell system operating on reformate fuel. This project extends the scope of existing cost studies to include externalities and ancillary financial benefits and thus provides a more comprehensive picture of fuel cell system benefits, consistent with a policy and incentive environment that increasingly values these ancillary benefits. The project provides a critical, new modelling capacity and should aid a broad range of policy makers in assessing the integrated costs and benefits of fuel cell systems versus other distributed generation technologies.

08 HYDROGEN↗

EPA RE-Powering America's Lands: Kansas City Municipal Farm Site ₋ Biomass Power Analysis

Through the RE-Powering America's Land initiative, the economic and technical feasibility of utilizing biomass at the Kansas City, Missouri, Municipal Farm site, a group of City-owned properties, is explored. The study that none of the technologies we reviewed--biomass heat, power and CHP--are economically viable options for the Municipal Farms site. However, if the site were to be developed around a future central biomass heating or CHP facility, biomass could be a good option for the site.

09 BIOMASS FUELS↗

Appendix D – GPRA06 Distributed Energy Program Documentation

Because the time horizon of the Annual Energy Outlook 2004 Reference Case (AEO-4 case) version of the National Energy Modeling System (NEMS) is 2025, and the goals of Distributed Energy (DE) programs are relatively short term, the approach taken in this GPRA cycle is that most of the outputs are captured before that date. However, DE programs are part of a wider effort to transform the power system from its current highly centralized form to a more robust decentralized paradigm, a transformation with a longer time horizon than NEMS-GPRA provides, and are not readily represented in the NEMS-GPRA framework. Distributed generation (DG) appears in multiple modules (roughly corresponding to subsectors of the full energy sector, i.e. utility, commercial, etc.), which hinders DE program’s representation in NEMS-GPRA. Further, only a limited number of technology slots are available to represent a broad array of equipment types, sizes, and configurations. For example, the reciprocating engines in the commercial sector all have combined heat and power (CHP) heating (but not cooling) capability, while those in the utility sector do not, while in some instances, engines without CHP might be attractive in the commercial sector and vice-versa. Proper representation of DE program goals includes an accurate representation of DE’s technologyadvancement targets, while accounting for the limitations of NEMS. Therefore, in addition to changing input assumptions relative to the AEO-4 version of NEMS, other fixes to perceived limitations or omissions are also appropriate in both the base and program cases.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Appendix D: GPRA05 Distributed Energy Program Documentation

Because the time horizon of the Annual Energy Outlook 2003 Reference Case (AEO-3 case) version of the National Energy Modeling System (NEMS) is 2025, and the goals of Distributed Energy (DE) programs are relatively short-term, the approach taken in this GPRA cycle is that most of the outputs are captured before that date. However, DE programs are part of a wider effort to transform the power system from its current highly centralized form to a more robust decentralized paradigm, a transformation with a longer time horizon than NEMS-GPRA provides. Distributed generation (DG) appears in multiple modules (roughly corresponding to subsectors of the full energy sector, i.e. utility, commercial, etc.), which hinders the DE program’s use of NEMS-GPRA. Further, only a limited number of technology slots are typically available to represent a broad array of equipment types, sizes, and configurations. For example, the reciprocating engines in the commercial sector all have combined heat and power (CHP) heating (but not cooling) capability, while those in the utility sector do not—in some instances, engines without CHP might be attractive in the commercial sector and vice-versa. Proper representation of DE program goals includes an accurate representation of DE’s technology-advancement targets, as well as an accounting for the limitations in the structure of NEMS, which can hinder estimation of the benefits that can be realized from DG technologies. Therefore, in addition to changing input assumptions relative to the AEO-3 version of NEMS, other fixes to perceived limitations or omissions are also appropriate in both the base and program cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Fuel Cell Markets in Japan and the US: Experience Curve Development and Cost Reduction Disaggregation

Fuel cells are both a longstanding and emerging technology for stationary and transportation applications, and their future use will likely be critical for the deep decarbonization of global energy systems. As we look into future applications, a key challenge for policy-makers and technology market forecasters who seek to track and/or accelerate their market adoption is the ability to forecast market costs of the fuel cells as technology innovations are incorporated into market products. Specifically, there is a need to estimate technology learning rates, which are rates of cost reduction versus production volume. Unfortunately, no literature exists for forecasting future learning rates for fuel cells. In this paper, we look retrospectively to estimate learning rates for two fuel cell deployment programs: (1) the micro-combined heat and power (CHP) program in Japan, and (2) the Self-Generation Incentive Program (SGIP) in California. These two examples have a relatively broad set of historical market data and thus provide an informative and international comparison of distinct fuel cell technologies and government deployment programs. We develop a generalized procedure for disaggregating experience-curve cost-reductions in order to disaggregate the Japanese fuel cell micro-CHP market into its constituent components, and we derive and present a range of learning rates that may explain observed market trends. Finally, we explore the differences in the technology development ecosystem and market conditions that may have contributed to the observed differences in cost reduction and draw policy observations for the market adoption of future fuel cell technologies. The scientific and policy contributions of this paper are the first comparative experience curve analysis of past fuel cell technologies in two distinct markets, and the first quantitative comparison of a detailed cost model of fuel cell systems with actual market data. The resulting approach is applicable to analyzing other fuel cell markets and other energy-related technologies, and highlights the data needed for cost modeling and quantitative assessment of key cost reduction components.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Green-House-Gas-Reduced Coal-and-Biomass-to-Liquid-Based Jet Fuel (GHGR-CBTL) Process - Final Technical report

This Final Technical Report describes the work and accomplishments of the project entitled, “Green-House-Gas-Reduced Coal-and-Biomass-to-Liquid-Based Jet Fuel (GHGR-CBTL) Process”. The main objective of the project was to raise the Technology Readiness Level (TRL) of the GHGR-CBTL fuel-production technology from TRL 4 to TRL 5 by producing a drop-in synthetic Jet Propellant 8 (JP-8) with a greenhouse-gas footprint less than or equal to petroleum-based JP-8 by utilizing mixtures of coal and biomass as the feedstock. The system utilizes the patented Altex fuel-production technology, which incorporates advanced catalysts developed by Pennsylvania State University. While the system was not fabricated and tested, major efforts were expended to design the 1-TPD and a full-scale plant. The system was designed, a Block-Flow Diagram (BFD), a Process-Flow Diagram (PFD), and Piping-and-Instrumentation Diagrams (P&IDs) were produced, a Bill of Materials (BOM) and associated spec sheets were produced, commercially available components were selected and procured, custom components were designed and fabricated, catalysts were developed and screened for performance, and permitting activities were conducted. Optimization tests for JP-8 production using C2 olefin as the feed were performed over a range of temperatures, pressures and WHSVs. Liquid yields of between 63 to 65% with 65% JP-8 fraction (41-42% JP-8 yield) at 50 psig were achieved. Life-Cycle Analysis (LCA) was performed by Argonne National Laboratory (ANL), and a GHGR-CBTL module was added to the Greenhouse gases, Regulated Emissions, and Energy use in Transportation (GREET®) model. Based upon the experimental results, the plant design was reconfigured for zero natural-gas imports and minimal electricity imports. The LCA analysis of the reconfigured process utilizing the GREET model showed that if the char from the process was utilized to produce combined heat and power (CHP) then a feed containing 23 wt% biomass and 77 wt% lignite would be needed for parity with petroleum-based JP-8. If the char is not utilized for CHP, but sequestered in a land fill, 24 wt% biomass and 76 wt% lignite would be required. A TEA was performed on this configuration following DOE guidelines and using the ANL-developed GREET module that showed that the GHGR-CBTL TOC and ECO are 69% and 58% of those for the DOE FT-Liquids Baseline Case, respectively. This analysis shows that the economics of the GHGR-CBTL process are significantly better than a gasification/FT process. No technical barriers were identified. The lower costs and the detailed design that was performed under this project are being used by Altex to attract funding partners to move the GHGR-CBTL development forward.

01 COAL, LIGNITE, AND PEAT↗

Final Technical Report: Affordable, High-Performance, Intermediate Temperature Solid Oxide Fuel Cells

In this project, we improved the power output and voltage efficiency of our intermediate temperature solid oxide fuel cells (IT-SOFCs) with a focus on ~600 °C operation. At these temperatures and with the increased power density (i.e., fewer cells for same power output), the stack cost should be greatly reduced while extending durability. Most SOFC stacks operate at temperatures greater than 800 °C. This can greatly increase the cost of the system (stacks and BOP) as well as maintenance costs since the most common degradation mechanisms are thermally driven. Our approach uses no platinum group metal (PGM) materials and the lower operating temperature allows use of simple stainless steel interconnects and commercial off-the-shelf gaskets in the stack. Furthermore, for combined heating and power (CHP) applications the stack exhaust still provides “high quality” waste heat that can be recovered and used in a chiller or boiler. The anticipated performance, durability, and resulting cost improvements (< $700/kWe) will also move us closer to reaching the full potential of this technology for distributed generation (DG) and residential/commercial CHP. This includes eventual extension to cleaner, more efficient portable generators, auxiliary power units (APUs), and range extenders for transportation. The research added to the understanding of the area investigated by exploring various methods for increasing power density (Watts/square centimeter of active area in each cell) and increasing cell efficiency (increasing the open circuit voltage, or cell voltage with zero external electrical current). The results from this work demonstrated an optimized cell that had greater than 1 W/cm2 at 600 °C and greater than 1.6 W/cm2 at 650 °C. This was demonstrated in large format sizes using both 5 cm by 5 cm and 10 cm by 10 cm cells. Furthermore, this work demonstrated that high stability (no degradation over > 500 hours) can be achieved together with high performance in large format cells as large as 10 cm by 10 cm when operated at ~600 °C. The project culminated in the demonstration of a 12-cell stack using the porous anode-based SOFC technology.

03 NATURAL GAS↗

Smart Matrix Development for Direct Carbonate Fuel Cell

FCE’s (FuelCell Energy, Inc.) SureSourceTM products based on high-temperature internal-reforming direct carbonate fuel cell (DFC®) technology are striving to meet growing worldwide demand for high-efficiency ultra-clean power for on-site electric and combined heat and power (CHP) generation. It promises ~20% higher energy conversion efficiency than existing technologies and its large-scale deployment would help to reduce GHG (Green House Gas) emission. In this program, FCE, teamed with University of Connecticut (UConn) and Illinois Institute of Technology (IIT), successfully developed an innovative electrolyte matrix (dubbed smart matrix since it promises higher power output, longer service life, and cost reduction gains concurrently) to enable the products to worldwide deployment. The electrolyte membrane (matrix) holds a very important key to fulfill these promises. The matrix, a porous microstructure consisting mainly of ultra-fine sub-micron α-LiAlO 2 powders sandwiched between two electrodes, immobilizes liquid electrolyte, isolates fuel from oxidant and facilitates ionic transport. However, faster coarsening of α-LiAlO 2 at the reducing anode side lowers capillary electrolyte-retention and eventually leads to matrix drying, limiting stack service life. This program, spanning over 3.5 years, successfully developed a high-yield cost-effective commercial-ready smart matrix with robust and stable fine-pore microstructure to enable the SureSource plants meeting DOE 2020 targets for CHP distributed generation fuel cell systems. Fundamental coarsening mechanism was established by investigating in detail the effects of electrolyte chemistry, powder morphology, powder purity, electrolyte chemistry, gas atmosphere and temperature. More stable powders with higher crystallinity, less surface disorder, less metastable impurities, less agglomeration and more uniform particle-size distribution have improved stability. FCE devised an innovative cost-effective additive approach to disrupt the fundamental coarsening process to enhance stability. The smart matrix design was validated in numerous long-term accelerated single cells and several 30kW technology stacks, many operated for >5,000 hours. Manufacturing process was successfully optimized to produce high-yield full-area (1 m 2 ) product-size smart matrices. Field deployment has been initiated. Successful development of this innovative smart matrix enables a quantum jump in useful life (100%) and power output (>20%). These improvements may project to >20% lower COE (Cost of Electricity) making the SureSource highly competitive with U.S. grid electricity cost leading to large-scale deployment, realizing the U.S. Government’s energy, environment, and economic agenda.

03 NATURAL GAS↗

ION Advanced Solvent CO 2 Capture Pilot Project

This final report to DOE/NETL presents all the work and tests performed during ION Engineering’s (ION) carbon dioxide (CO 2 ) capture pilot test campaign: “ION Advanced Solvent CO 2 Capture Project”. This project is comprised of three budget periods (BP): BP1 – Design of a 0.6 MWe system, BP2 – 0.5 MWe National Carbon Capture Center (NCCC) Testing Campaign, and BP3 – 12 MWe Technology Center at Mongstad (TCM) Testing Campaign. The program began in October 2013 and continued until December 2017. The campaign at NCCC, which took place from June to August of 2015, resulted in 1,116 operational hours where ~350 tonnes of CO 2 were captured from the 0.5 MWe coal-fired flue gas slipstream. The follow-up campaign at TCM took place from Oct 2016 to April 2017, where 2,775 hours of operation resulted in the capture of 14,820 tonnes of CO 2 , which is a cumulative of capturing CO 2 from the natural gas-fired Combined Heat and Power (CHP) plant, and a residue fluid catalytic cracker gas (RFCC) from Statoil at Mongstad. ION has conducted a thoughtful, comprehensive, and successful program in close collaboration with all its partners. CO 2 was successfully removed and captured for extended periods of time using three gas sources (NCCC Coal-fired Power plant, TCM CHP flue gas with and without CO 2 recycle, and TCM RFCC flue gas with air dilution) at various slipstream flows ranging from 0.5 MWe to 12 MWe. The data gathered on its solvent continues to strengthen the development of ION’s advanced solvent and positive track record in executing on-site test campaigns in highly industrialized settings. These existing pilot plants do not include the necessary process modifications that ION requires to obtain the lowest possible regeneration energy; processes such as a cold-rich bypass and intercooling, would allow for lowering the demonstrated specific reboiler duty. The resulting data was also used to validate the process model, and, in the absence of testing on a custom test rig specifically designed for ION’s advanced solvent, the results of the process model have shown specific reboiler duties under 2.5 MJ/kg CO 2 (1075 BTU/lb CO 2 ). When these regeneration energies are factored into the Techno-Economic Analysis (TEA), where ION’s technology is compared to the DOE/NETL BBS Case 12, which integrates a highly optimized and commercially available CO 2 capture technology, ION’s technology shows: 38% incremental reduction in capital cost of CO 2 capture; 28% incremental reduction in annual operating and maintenance costs of CO 2 capture; and $35-44 per tonne of CO 2 capture, which is a 20% to 40% reduction in cost of CO 2 capture. Throughout pilot testing, ION has confirmed its understanding of process improvements and analytics that will enable successful operation of its advanced solvent at significantly lower L/G circulation rates, packing heights and regeneration energies than MEA. ION has identified routes to further develop its technology and is looking forward to testing a fully optimized solvent and capture system in the near future.

01 COAL, LIGNITE, AND PEAT↗

Demonstration of μCHP in Light Commercial Hot Water Applications

Internal combustion engine driven combined heat and power (CHP) systems produce power while the waste heat is recovered and used for another purpose. For µCHP systems (less than 50kWe output) overall efficiencies can reach over 90% for products currently on the market throughout the world. On a fuel basis this offers an advantage over using grid-based power and another fuel for heat. Additionally, the cost of natural gas on an energy unit basis is significantly less expensive than electric power. This difference can lead to substantial savings for the end user of a CHP system. In some parts of the world, particularly Germany and Japan, µCHP has become a common part of the heat and distributed generation equipment mix. Market analysis conducted in 2012 showed that in North America there is potential of a 5,300 units per year market for µCHP, resulting in an annual energy savings of approximately 13.5 TBtu and more than $84 million in annual customer savings. However, µCHP still has not seen much market penetration in North America. This study helps to identify some of the reasons why, address roadblocks that still need to be overcome and provide experience to established best practices. Nine commercial sites were initially identified (fitness club, surgical center, senior community, resort and spa, commercial laundry, two multi-family housing, restaurant and manufacturing facility). Systems from two different manufacturers were installed at five sites total, but due to unforeseen circumstances, only three of those sites were finally commissioned: test data were collected by Oak Ridge National Laboratory. While not all systems were installed as intended, the project resulted in the following key findings: Micro combined heat and power is an unfamiliar technology for building owners and plumbing and electrical contractors that serve the buildings most suited for µCHP. Manufacturers will need to be aggressive in providing training and providing broad support to successfully bring the technology to market.; The proper integration of µCHP into other building systems is the most critical part of a successful installation. Manufacturers will need to be able to provide the expertise to train, advise and support the mechanical contractors during the design and installation of the heat integration system.; Regulations governing µCHP varies across the country. There are a few UL standards (UL 2200 and UL 1741) that apply nationally. Emissions are governed by EPA except in California where the California Air Resources Board (CARB) has established their own standard. Requirements that dictate installation and interconnection are dependent on local building codes and local utility processes and requirements. Some out of date building codes do not offer clear guidance for these requirements, leading to confusion. This makes developing training and determining broadly applicable best practices difficult.; Installation costs of µCHP are a key factor in making an installation successful. It is critical that these costs and all national, state and local regulations be understood and accounted for by all parties involved in the installation before a project is undertaken.; A robust customer service organization is important to meet the needs of the customers. These systems require annual maintenance and service and local capability is needed to keep costs inline.

03 NATURAL GAS↗