Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Fast and accurate simulations of calorimeter showers with normalizing flows

In this study, we introduce caloflow, a fast detector simulation framework based on normalizing flows. For the first time, we demonstrate that normalizing flows can reproduce many-channel calorimeter showers with extremely high fidelity, providing a fresh alternative to computationally expensive geant4 simulations, as well as other state-of-the-art fast simulation frameworks based on generative adversarial networks (GANs) or variational autoencoders (VAEs). In addition to the usual histograms of physical features and images of calorimeter showers, we introduce a new metric for judging the quality of generative modeling: the performance of a classifier trained to differentiate real from generated images. We show that GAN-generated images can be identified by the classifier with nearly 100% accuracy, while images generated from caloflow are better able to fool the classifier. More broadly, normalizing flows offer several advantages compared to other state-of-the-art approaches (GANs and VAEs), including tractable likelihoods, stable and convergent training, and principled model selection. Normalizing flows also provide a bijective mapping between data and the latent space, which could have other applications beyond simulation, for example, to detector unfolding.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerating accurate simulations of calorimeter showers with normalizing flows and probability density distillation

Recently, we introduced caloflow, a high-fidelity generative model for GEANT4 calorimeter shower emulation based on normalizing flows. Here, we present caloflow v2, an improvement on our original framework that speeds up shower generation by a further factor of 500 relative to the original. The improvement is based on a technique called probability density distillation, originally developed for speech synthesis in the machine learning literature, and which we develop further by introducing a set of powerful new loss terms. We demonstrate that caloflow v2 preserves the same high fidelity as the original using qualitative (average images, histograms of high-level features) and quantitative (classifier metric between geant4 and generated samples) measures. The result is a generative model for calorimeter showers that matches the state of the art in speed (a factor of 10 4 faster than GEANT4) and greatly surpasses the previous state of the art in fidelity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anomaly detection with flow-based fast calorimeter simulators

Recently, several normalizing flow-based deep generative models have been proposed to accelerate the simulation of calorimeter showers. Using caloflow as an example, we show that these models can simultaneously perform unsupervised anomaly detection with no additional training cost. As a demonstration, we consider electromagnetic showers initiated by one (background) or multiple (signal) photons. The caloflow model is designed to generate single-photon showers, but it also provides access to the shower likelihood. We use this likelihood as an anomaly score and study the showers tagged as being unlikely. As expected, the tagger struggles when the signal photons are nearly collinear but is otherwise effective. This approach is complementary to a supervised classifier trained on only specific signal models using the same low-level calorimeter inputs. While the supervised classifier is also highly effective at unseen signal models, the unsupervised method is more sensitive in certain regions, and, thus, we expect that the ultimate performance will require a combination of these approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear-nuclear collision centrality determination by the spectators calorimeter for the MPD setup at the NICA facility

The work conditions of the hadron calorimeter for spectators registration (Zero Degree Calorimeter, ZDC) were studied for the heavy nuclei collisions with the several GeV invariant energy. The ZDC simulations were performed for the MPD (Multi-Purpose Detector) at the NICA (Nuclotron-based Ion Collider fAcility) collider, which are under developement at the Joint Institute for Nuclear Research (JINR, Dubna). Taking into account the spectator nuclear fragments leads to a nonmonotonic dependence of the ZDC response on the impact parameter. The reason for this dependence studied with several event generators is the primary beam hole in the ZDC center. It is shown, that the ZDC signal should be combined with a data from other MPD-NICA detector subsystems to determine centrality.

74 ATOMIC AND MOLECULAR PHYSICS↗

TEST REPORT #11: Compressor Calorimeter Test of R-410A Alternatives R-32, DR-5, and L-41a

As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares performance of alternative refrigerants R32, DR-5, and L-41A to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. Compressor calorimeter tests were performed to evaluate the performance of the lower-GWP alternative refrigerants in place of the common refrigerant R-410A in a 36,000 Btu/hr compressor calorimeter using a compressor having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10°F to 55°F in 5°F increments and a discharge dew point temperature range of 70°F to 140°F in 10°F increments. All the tests were performed with 20°F superheat, 40°F superheat and 65°F suction temperature. A liquid subcooling level of 15°F was maintained for all the test conditions. The tests showed that performance of these three lower-GWP alternative refrigerants is comparable to that of R-410A. For the 20°F superheat and 15°F subcooling test conditions, EERs of R32, DR-5, and L-41A were 90% to 99%, 96% to 99%, and 94% to 101%, respectively, compared to that of R-410A. Similarly, cooling capacities of R32, DR-5, and L-41A were 98% to 103%, 92% to 96%, and 84% to 92%, respectively, compared to that of R-410A.

Alternative Refrigerants↗

Design and Prototyping of a High Granularity Scintillator Calorimeter

A novel approach for constructing fine-granularity scintillator calorimeters, based on the concept of an Integrated Readout Layer (IRL) was developed. The IRL consists of a printed circuit board inside the detector which supports the directly-coupled scintillator tiles, connects to the surface-mount SiPMs and carries the necessary front-end electronics and signal/bias traces. Prototype IRLs using this concept were designed, prototyped and successfully exposed to test beams. Concepts and implementations of an IRL carried out with funds associated with this contract promise to result in the next generation of scintillator calorimeters.

Direct coupling↗

A study on dual readout crystal calorimeter for hadron and jet energy measurement at a future lepton collider

Studies of requirements and specifications of crystals are necessary to develop a new generation of crystals for dual readout crystal hadron or total absorption calorimeter. This is a short and basic study of the characteristics and hadron energy measurement of PbWO4 and BGO crystals for scintillation and Cerenkov Dual Readout hadron calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance And Operation of the BaBar Calorimeter

The performance and operation of the CsI(Tl) crystal calorimeter of the BABAR detector during the last years of operation is discussed. The BABAR detector is located at the PEP-II B Factory at the Stanford Linear Accelerator Center (SLAC). PEP-II is an asymmetric e{sup +}e{sup -}-collider operating mainly at a center-of-mass energy of 10.58 GeV. This corresponds to the mass of the {Upsilon}(4S) resonance, which decays exclusively into B{sup 0}{bar B}{sup 0} and B{sup +}B{sup -} pairs. One main physics goal of the BABAR experiment was the measurement of CP-violating asymmetries in the decay of neutral B-mesons. Other goals of the experiment include precision measurements of the decays of bottom mesons to charm and {tau} leptons, as well as searches for rare decays utilizing the high luminosity delivered by the PEP-II accelerator. The BABAR detector (Fig 1) consists of 6 subdetectors. Starting from the interaction point and moving radially outwards there is a Silicon Vertex Detector, Drift Chamber, DRC (Cherenkov detector), an Electromagnetic Calorimeter, and an Instrumented Flux Return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the BaBar CsI(Tl) Calorimeter

After nine years of operation, the BABAR experiment at the e{sup +}e{sup -} B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standardization of tritium measuring devices based on a high-sensitivity calorimeter

A twin type thermal conduction calorimeter has been specially designed and constructed for absolute measurement of tritium, and then its performance was examined using two kinds of tritium samples, i.e., ZrNi alloy powders loaded with a given amount of tritium. Total amounts of tritium in the ZrNi alloy powders were previously estimated by a small ionization chamber. Changes in radioactivity of two samples were followed for three years, and it was seen that the activity changes obeys the half-life of 4505 days. The initial tritium amounts estimated by the small ionization chamber agreed well with the extrapolated values from the activity changes evaluated by the calorimeter. Namely, it was suggested that the small ionization chamber is able to be used as a secondary standard of the tritium measuring devices. The {beta}-ray-induced X-ray counter was also calibrated for non-destructive measurements of high-level tritium by using the present small ionization chamber. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for neutral long-lived particles that decay into displaced jets in the ATLAS calorimeter in association with leptons or jets using pp collisions at $\sqrt{\textrm{s}}$ = 13 TeV

A search for neutral long-lived particles (LLPs) decaying in the ATLAS hadronic calorimeter using 140 fb -1 of proton-proton collisions at $\sqrt{s}$ = 13 TeV delivered by the LHC is presented. The analysis is composed of three channels. The first targets pair-produced LLPs, where at least one LLP is produced with sufficiently low boost that its decay products can be resolved as separate jets. The second and third channels target LLPs respectively produced in association with a W or Z boson that decays leptonically. In each channel, different search regions target different kinematic regimes, to cover a broad range of LLP mass hypotheses and models. No excesses of events relative to the background predictions are observed. Higgs boson branching fractions to pairs of hadronically decaying neutral LLPs larger than 1% are excluded at 95% confidence level for proper decay lengths in the range of 30 cm to 4.5 m depending on the LLP mass, a factor of three improvement on previous searches in the hadronic calorimeter. The production of long-lived dark photons in association with a Z boson with cross-sections above 0.1 pb is excluded for dark photon mean proper decay lengths in the range of 20 cm to 50 m, improving previous ATLAS results by an order of magnitude. Finally, long-lived photo-phobic axion-like particle models are probed for the first time by ATLAS, with production cross-sections above 0.1 pb excluded in the 0.1 mm to 10 m range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Autoencoder-Based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online data quality monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. In addition, the first results from deploying the autoencoder-based system in the CMS online data quality monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e Calorimeter Readout System

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: (1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; (2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of 200MHz with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of 20krads , neutron flux of 10 12 n(1MeVeq)/cm 2 , magnetic field of 1T and in vacuum level of 10 -4 Torr . A description of the readout system and qualification tests is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and data path integration test of the global Feature EXtractor for the ATLAS Level-1 calorimeter trigger system Phase-I upgrade

The global Feature Extractor (gFEX) is a component of the Phase-I upgrade of the Level-1 Calorimeter (L1Calo) trigger system for the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The gFEX is used to identify patterns of energy associated with the hadronic decays of high momentum Higgs, W and Z bosons, top quarks, and exotic particles in real time at the 40 MHz LHC bunch crossing rate. Three prototypes were implemented and tested from 2014 to 2017. With the lessons learned from the prototypes, the final gFEX production board has been implemented at the end of 2017. The gFEX receives up to 300 fiber optical links from the calorimeter and transmits trigger data on 96 links to the ATLAS Level-1 Topological [1] (L1Topo) trigger at a rate of up to 12.8 Gb/s. There are also 24 electrical links on board for communication between two FPGAs running at speeds of up to 25.6 Gb/s. Here, the hardware functionality and performance of the production board have been evaluated. A data path integration test between the Liquid Argon Digital Processing Blade (LDPB) [2] and the Front End LInk eXchange (FELIX) [3] was performed successfully at CERN in 2018.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the spatial shift in detector response for polarized protons within a calorimeter

Measurement of the helicity dependent elastic electron-proton scattering cross section provides a key means of investigating parity violation within the proton. However, such measurements exhibit potential instrumental effects associated with the detection of polarized recoiled protons. In particular, spin-orbit interactions within a massive detector induce a systematic spatial shift in the detector signal. In this study, we determine the size of this shift using the Geant4 simulation toolkit. For a typical hadron calorimeter, we found a polarization dependent shift on the order of 0.01-0.1 mm, multiple orders of magnitude smaller than the typical spatial resolution seen in hadronic calorimeters. Additionally, we provide the custom modifications required of the Geant4 source code to implement the quasi-elastic scattering of polarized protons incident on nuclei in the detector. The modifications are readily extendable to generic matter sources, and can be used for the study of additional spin dependent observables in Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗