Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A review of issues and strategies in nondestructive evaluation of fiber reinforced structural composites

The need for advanced nondestructive evaluation (NDE) techniques for quantitative assessment of the mechanical strength and integrity of fiber composites during manufacture and service and following repair operations is stressed. The discussion covers problems and different approaches in regard to acceptance criteria, calibration standards, and methods for NDE of composites in strength critical applications. Finally, it is concluded that acousto-ultrasonic techniques provide the 'methods of choice' in this area.

Vary, A.↗

Summary of flight technology workshop on radiometric calibration

The conclusions and recommendations from a three-day NASA sponsored workshop to assess deficiencies and shortcomings of previously flown electro-optical space sensors are summarized. Space technologists for NASA, NOAA, DOD, and industry also developed recommendations for improving instrumentation and calibration technology. The conclusions reached include the fact that the past knowledge of in-orbit radiometric accuracy has been poor relative to available calibration standards, whereas stringent accuracy requirements for planned NASA programs will require significant SOA improvements. The Shuttle contamination environment may also compromise future sensor accuracy. A number of panel recommendations to improve in-orbit accuracy of future sensors will be summarized, including one to establish a set of National Standards for Remote Sensors at NBS as a basis for long term accuracy.

Dodgen, J. A.↗

BL Herculis stars - Theoretical models for field variables

Type II Cepheids with periods between 1 and 3 days, commonly designated as Bl Herculis stars, have been modeled here with the aim of interpreting the wide variety of light curves observed among the field variables. Previously modeled globular cluster members are used as standard calibration objects. The major finding is that only a small range of luminosities is capable of generating a large variety of light curve types at a given period. For a mass of approximately 0.60 solar mass, the models are able to reproduce the observed mean luminosities, dispersion of mean luminosities, periods, light amplitudes, light asymmetries, and phases of secondary features in the light curves of known BL Her stars. It is possible that the metal-rich variables (which are found only in the field) have luminosities lower than those of most metal-poor variables. The present revised mass for BL Her, a metal-rich object, is not significantly different from the mean mass of the metal-poor variables.

Carson, R.↗

NTF model pressure measurements

Pressure measurements on the National Transonic Facility models will be made using electronically scanned pressure instrumentation. The system consists of pressure modules, a pressure calibration standard, and a system controller. The pressure modules, which must be operated above -18 C, will be housed in model-integrated designed thermally controlled containers. The Pathfinder 1 192-channel pressure package is described. Recent and planned developments to reduce the pressure module's volume per channel ratio are discussed, including the 48-channel module and a proposed 32-channel module that would be 2.54 by 2.54 by 8.13 cm. Pressure transducers capable of operating at cryogenic temperatures for dynamic and static pressure measurements are discussed.

Kern, F. A.↗

The Atmospheric Lifetime Experiment. II - Calibration

The calibration standards used in the Atmospheric Lifetime Experiment (ALE) for CFCl3, CF2Cl2, CH3CCl3, and CCl4 are described. This includes the preparation of the primary standards by static dilution and their propagation and stability for the period 1977-1982. Two independent assessments of the absolute concentrations of the primary standards used to initiate the ALE measurements in 1977-1978 are reported. For consistency in the ALE program the values assigned to the primary standards and subsequent working standards used in the field were not altered during the experiment when results of better estimates of the original concentration values were obtained. Rather, the appropriate factors by which the ALE mixing ratios for a given species should be multiplied to obtain the best estimate of the current concentration of a given species, are provided.

Rasmussen, R. A.↗

The great Tambora eruption in 1815 and its aftermath

The events consequent to the cataclysmic eruption of Mount Tambora, Indonesia, in April of 1815 are reconstructed by quantitative analytical methods which synthesize data and methods from the volcanological, oceanographic, glaciological, meteorological, climatological, astronomical and historical disciplines. This eruption is noteworthy in having been an order of magnitude greater in discharged pyroclastics volume than the Krakatau eruption of 1883, and further, in exceeding the size of any known eruption in the last 10,000 years. The mean temperature in the Northern Hemisphere dropped by 0.4 to 0.7 C in 1816 as a result of its dust veil. It is suggested that Tambora may be used as a calibrating standard in the investigation of other volcanic eruptions.

Stothers, R. B.↗

Far Infrared and Submillimeter Observations of the Giant Planets

Far infrared measurements of the effective temperatures of Jupiter, Saturn, Uranus and Neptune were made. The measurements presented here cover the range from 35-1000 micrometers in relatively narrow bands. The observations at lambda 350 micrometers were made at the 3m NASA Infrared Telescope Facility (IRTF) of the Mauna Kea Observatory; those at lambda 350 micrometer were made on the Kuiper Airborne Observatory (KAO). All observations of Saturn were made when the ring inclination to Earth was 1.7 deg assuring an unambiguous measurement of the flux from the disk itself. Mars was used as the calibration reference. The results represent a consistent set of calibration standards. In these measurements, it is assumed that sub b(lambda = 350 micrometers) = T sub (lambda 350 micrometers). Measurements have been made of roughly 50% of the total flux emitted by Jupiter, 65% by Saturn, and 92% by Uranus and Neptune. These measurements therefore permit a considerable reduction in the uncertainties associated with the bolometric thermal outputs of the planets. The effective temperatures (T sub e) and the ratios of emitted to absorbed solar radiation were calculated.

Loewenstein, R. F.↗

A cryogenic blackbody for millimeter wavelengths

The present cryogenic blackbody reference, or 'cold load', for mm-wavelength radiation has an emissivity of more than 0.99 over a two-octave wavelength range and can be used as a calibrating standard for sensitive IR photometers. The transmittance spectrum obtained indicates that wave impedance and index do not vary significantly over the 80-360 GHz range.

Peterson, J. B.↗

On the direct and dissociative excitation of the O(3s 3S0) state by electron impact on atomic and molecular oxygen

The ratio of the cross sections for the direct and dissociative excitation of the OI(3s 3S0-2p 3P; 1304 A wavelength) transition, sigma A/sigma D, are accurately determined, and the sigma A/sigma D ratio is directly normalized to the ratio of the O(+) and O2(+) ionization cross sections using a high-density diffuse gas source, an electrostatically focused electron gun, a vacuum-ultraviolet monochromater, and a quadrupole mass spectrometer for simultaneous optical and composition measurements. Using revised sigma A(1304 A) values calculated with new calibration standards, the shape of the cross section for the excitation of the O(3s 3S0) state agrees well with previous results, though the absolute magnitude of sigma A(1304 A) is smaller than the results of Stone and Zipf (1974) by a factor of 2.8. The revised cross sections agree well with recent quantum calculations when cascade excitation of the 3s 3S0 state is taken into account.

Zipf, E. C.↗

Device Maintains Water At The Triple Point

Inexpensive device maintains water at 0.01 degree C for 10 weeks or longer. New device consists of four basic assemblies; small, commercial chest freezer containing insulated water tank; insulated copper cell holder; "ice switch" for cycling freezer compressor and externally-mounted air pump for circulation. Access hole in freezer lid allows triple point measurements without opening lid. Modified freezer used to calibrate standard platinum resistance thermomenters.

West, J. W.↗

Universal test fixture for monolithic mm-wave integrated circuits calibrated with an augmented TRD algorithm

The design and evaluation of a novel fixturing technique for characterizing millimeter wave solid state devices is presented. The technique utilizes a cosine-tapered ridge guide fixture and a one-tier de-embedding procedure to produce accurate and repeatable device level data. Advanced features of this technique include nondestructive testing, full waveguide bandwidth operation, universality of application, and rapid, yet repeatable, chip-level characterization. In addition, only one set of calibration standards is required regardless of the device geometry.

Romanofsky, Robert R.↗

Characterization of production GaAs solar cells for space

The electrical performance of GaAs solar cells was characterized as a function of irradiation with protons and electrons with the underlying goal of producing solar cells suitable for use in space. Proton energies used varied between 50 keV and 10 MeV, and damage coefficients were derived for liquid phase epitaxy GaAs solar cells. Electron energies varied between 0.7 and 2.4 MeV. Cells from recent production runs were characterized as a function of electron and proton irradiation. These same cells were also characterized as a function of solar intensity and operating temperature, both before and after the electron irradiations. The long term stability of GaAs cells during photon exposure was examined. Some cells were found to degrade with photon exposure and some did not. Calibration standards were made for GaAs/Ge solar cells by flight on a high altitude balloon.

Anspaugh, B. E.↗

AM0 efficiency measurements

Procedures for measuring the air mass zero (AM0) current versus voltage characteristics and calculating the efficiency are discussed. The various factors influencing the determination of the efficiency include the I-V measurement system, reference cell calibration, standard reporting conditions, area measurement, light source characteristics, temperature measurement and control, and the measurement procedures. Each of these sources contributes to the precision index and bias limit which is combined to obtain the total uncertainty in the efficiency. These factors are discussed as well as how to minimize differences in the reported AM0 efficiency of a given PV cell between various laboratories.

Emery, Keith↗

Microwave microstrip resonator measurements of Y1Ba2Cu3O(7-x) and Bi2Sr2Ca1Cu2O(8-y) thin films

Radio frequency (RF) surface resistance measurement experiments on high T(sub c) thin films were performed. The method uses a microstrip resonator comprising a top gold conductor strip, an alumina dielectric layer, and a separate superconductivity ground plane. The surface resistance of the superconducting ground plane can be determined, with reference to a gold calibration standard, from the measured quality factor of the half-wave resonator. Initial results near 7 GHz over the temperature range from 25 to 300 K are presented for YBa2Cu3O(7-x) and Bi2Sr2CaCu2O(8-y) thin film samples deposited by an electron beam flash evaporation process. The RF surface resistance at 25 K for both materials in these samples was found to be near 25 milliohms.

Lichtenberg, Christopher L.↗

The distribution of middle tropospheric carbon monoxide during early October 1984

The distribution of middle tropospheric carbon monoxide measure by the Measurement of Air Pollution from Satellites (MAPS) instrument carried aboard the space shuttle is reported. The data represent average mixing ratios in the middle troposphere and are presented in the form of maps that show the carbon monoxide mixing ratios averaged for 6 days of the mission. Comparisons with concurrent, direct measurements taken aboard aircraft show that the inferred concentrations are systematically low by from 20 to 40 percent depending upon which direct measurement calibration standard is used. The data show that there are very large CO sources resulting from biomass burning over South America and southern Africa. Measured mixing ratios were high over northeast Asia and were highly variable over Europe.

Reichle, Henry G., Jr.↗

Space Station-era ground data handling

Planning is underway for the handling of the peak return link data rates ranging from 300 to 1200 Mbps that are associated with the emerging Space Station orbital-systems era. Ground data handling services encompass the enhancement of on-board ancilliary data packets to furnish standard calibrations and transformations not available on-board; remote access to an interactive data base will allow users to select and withdraw specified parameters based on user-defined criteria.

Smith, Gene A.↗

Calibration of the Shuttle borne solar backscatter ultraviolet spectrometer

The Shuttle Solar Backscatter UV (SSBUV) spectrometer that will be furnishing regular, on-orbit calibration checks of the ozone-monitoring instruments aboard NOAA satellites. The long-term ozone-monitoring program requires a reduction of uncharacterized drifts in the satellite instrument to a value lower than the expected ozone trend at the 95 percent confidence level; this translates into a requirement for the calibration of the SSBUV to a 1-sigma precision level of 1 percent from one flight to the next. A hierarchy of calibration standards is used to furnish redundancy and minimize biases; laboratory fixtures have been designed to minimize setup-induced systematic errors.

Cebula, Richard P.↗