Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Aemulus $\nu$: precise predictions for matter and biased tracer power spectra in the presence of neutrinos

Here we present the Aemulusν simulations: a suite of 150 (1.05 h -1 Gpc) 3 N-body simulations with a mass resolution of 3.51 × 10 10 Ω cb /0.3 h -1 M ⊙ in a wνCDM cosmological parameter space. The simulations have been explicitly designed to span a broad range in σ8 to facilitate investigations of tension between large scale structure and cosmic microwave background cosmological probes. Neutrinos are treated as a second particle species to ensure accuracy to 0.5 eV, the maximum neutrino mass that we have simulated. By employing Zel'dovich control variates, we increase the effective volume of our simulations by factors of 10-10 5 depending on the statistic in question. As a first application of these simulations, we build new hybrid effective field theory and matter power spectrum surrogate models, demonstrating that they achieve ≤ 1% accuracy for k ≤ 1 hMpc -1 and 0 ≤ z ≤ 3, and ≤ 2% accuracy for k ≤ 4 hMpc -1 for the matter power spectrum. We publicly release the trained surrogate models, and estimates of the surrogate model errors in the hope that they will be broadly applicable to a range of cosmological analyses for many years to come.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulated effects of sample size and grain neighborhood on the modeling of extreme value fatigue response

Assessing the size of representative volume elements (RVEs) for fatigue-related applications is challenging. A RVE relevant to random microstructure requires a volume of material that is sufficiently large to capture the grain/phase heterogeneity that captures all statistical moments of the distribution of the driving force for fatigue crack formation at “hot spot” grains. Consequently, the large size of a microstructure RVE required to study fatigue phenomena is largely computationally intractable and difficult to explore. A more realistic objective in this work is to systematically study, as a function of the size of a statistical sample of microstructure, trends towards convergence of the simulated distribution of driving force for fatigue crack formation. Our present work accordingly leverages the recently developed open-source PRISMS-Fatigue framework to examine the trends in convergence of extreme value distributions (EVD) of Fatigue Indicator Parameters (FIPs) in progressively larger polycrystalline microstructure realizations of FCC Al alloy 7075-T6 using crystal plasticity finite element method simulations. The results are compared to the traditional method in which ensembles of statistical volume elements (SVEs) are simulated to build up statistics intended to approximate those associated with a larger volume of material. The convergence of EVDs with increase of size of a SVE of microstructure is closely related to the extent of grain nearest neighbor (NN) interactions. Accordingly, the sensitivity of the local micromechanical response at hot spot grains is quantitatively investigated by systematically varying the orientations of NN grains. Results indicate that SVEs with cubic crystallographic texture tend towards convergence of the EVD of FIPs with tens of thousands of grains while the random and rolled textures require larger volumes. Simple relationships based on microstructure parameters (e.g., Schmid Factor, grain size, NN misorientation) do not completely correlate to fatigue hot spot grains. Finally, the sensitivity of the extreme value fatigue response at hot spot grains extends to the 3rd NN when a single neighborhood grain orientation is altered.

36 MATERIALS SCIENCE↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An ontology to represent synthetic building occupant characteristics and behavior

Since the introduction of the occupant behavior Drivers-Needs-Actions-Systems (DNAS) framework in 2013, researchers have used the framework or further developed it based on their case studies, which include efforts to collect new data on occupant behaviors. The effort is often costly for the relatively few new data points added. Problems emerge when the already collected data do not meet the modelers' interoperability requirements. Previous studies addressed this issue by developing more sophisticated ontologies that enable integration with other datasets and synthetic data methodologies that would meet unique research applications. This paper presents an extension of the DNAS framework for the representation of synthetic occupant data to support various applications and use cases across the building life cycle. An agent-based modeling application is one of our motivations that requires more elaborate characteristics of an occupant-agent or a group-of-agent. The extension, built upon a review of the literature, introduces new elements to the framework that fall into five categories, including socio-economic, geographical location, activities, subjective values, and individual and collective adaptive actions. On-going research includes identifying occupant datasets and developing data fusion methods to generate synthetic occupants, as well as to demonstrate its applications in agent-based modeling coupled with building performance simulation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling

The evaluation of natural ventilation potential for cooling indoor spaces during the early design phases is of great interest to researchers and practitioners. Among various definitions and usages for natural ventilation potential (NVP) in early design evaluation, this paper reviews and identifies the key performance indicators, and proposes two new dynamic metrics—natural ventilation cooling effectiveness (NVCE) and climate potential utilization ratio (CPUR). The metrics are dynamically responsive to various design options, in both steady and transient states, allowing consideration of thermal mass. Assisting in design development processes, the metrics quantify how well indoor spaces make use of natural ventilation’s cooling capacity. Case studies are presented to demonstrate how NVCE and CPUR enable designers to evaluate the predicted performance and how to apply the information to improve building design. Finally, the results of the design iterations showed that the relationship among various design parameters should be dynamically understood in order to evaluate the performance of natural ventilation, confirming that “the more the airflow, the greater the potential,” and “the heavier the thermal mass, the greater the energy saving” were not always true.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

From roads to roofs: How urban and rural mobility influence building energy consumption

In this article, understanding the relationship between travel behavior and building energy use at an urban scale is crucial for developing effective energy management strategies. Mobility patterns significantly impact building occupancy, which in turn affects energy consumption. However, existing methods often focus on individual buildings, whereas geographical influences on energy usage are not adequately examined. This study addresses this gap by using transportation origin-destination (OD) data to estimate building occupancy and energy. The proposed method assigns OD trips from census block groups to the building level, incorporating building, travel survey, and census data to derive building occupancy profiles. This method was applied to urban and rural areas with 4062 buildings in 70 census block groups. We found that the OD-informed occupancy profile exhibits smoother energy consumption patterns compared with that of Department of Energy reference occupancy profiles. Our analysis reveals distinct building energy consumption patterns among groups with long and short commutes, emphasizing the effect of commute times and work schedules on residential energy usage. This framework is useful for practitioners in transportation agencies and utility companies, enabling the estimation of building energy based on mobility patterns. Overall, this study shows the potential of integrating transportation and building energy data to inform cross-sector energy management strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Specific Ion Solvation and Pairing Effects in Glycerol Carbonate

Identifying the driving forces behind the solvation of inorganic salts by nonaqueous solvents is an important step in the development of green solvents. Here we focus on one promising solvent: glycerol carbonate (GC). Using ab initio molecular dynamics simulations, we build upon our previous work by detailing glycerol carbonate’s interactions with a series of anions, a lithium ion, and the LiF ion pair. Through these investigations, we highlight the changes in solvation behavior as the anion size increases, the competition of binding shown by lithium for the oxygens of GC, and the behavior of the LiF ion pair in a GC solution. These results in this work indicate the importance of the cation’s identity in ion-pairing structure and dynamics and lend insight into the key factors behind the specific ion effects seen in GC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the Senseiver for efficient field reconstruction from sparse observations

Abstract The reconstruction of complex time-evolving fields from sensor observations is a grand challenge. Frequently, sensors have extremely sparse coverage and low-resource computing capacity for measuring highly nonlinear phenomena. While numerical simulations can model some of these phenomena using partial differential equations, the reconstruction problem is ill-posed. Data-driven-strategies provide crucial disambiguation, but these suffer in cases with small amounts of data, and struggle to handle large domains. Here we present the Senseiver, an attention-based framework that excels in reconstructing complex spatial fields from few observations with low overhead. The Senseiver reconstructs n -dimensional fields by encoding arbitrarily sized sparse sets of inputs into a latent space using cross-attention, producing uniform-sized outputs regardless of the number of observations. This allows efficient inference by decoding only a sparse set of output observations, while a dense set of observations is needed to train. This framework enables training of data with complex boundary conditions and extremely large fine-scale simulations. We build on the Perceiver IO by enabling training models with fewer parameters, which facilitates field deployment, and a training framework that allows a flexible number of sensors as input, which is critical for real-world applications. We show that the Senseiver advances the state-of-the-art of field reconstruction in many applications.

97 MATHEMATICS AND COMPUTING↗

A Novel Partitioned Approach for Reduced Order Model—Finite Element Model (ROM-FEM) and ROM-ROM Coupling

Partitioned methods allow one to build a simulation capability for coupled problems by reusing existing single-component codes. In so doing, partitioned methods can shorten code development and validation times for multiphysics and multiscale applications. In this work, we consider a scenario in which one or more of the “codes” being coupled are projection-based reduced order models (ROMs), introduced to lower the computational cost associated with a particular component. We simulate this scenario by considering a model interface problem that is discretized independently on two non-overlapping subdomains. Here we then formulate a partitioned scheme for this problem that allows the coupling between a ROM “code” for one of the subdomains with a finite element model (FEM) or ROM “code” for the other subdomain. The ROM “codes” are constructed by performing proper orthogonal decomposition (POD) on a snapshot ensemble to obtain a low-dimensional reduced order basis, followed by a Galerkin projection onto this basis. The ROM and/or FEM “codes” on each subdomain are then coupled using a Lagrange multiplier representing the interface flux. To partition the resulting monolithic problem, we first eliminate the flux through a dual Schur complement. Application of an explicit time integration scheme to the transformed monolithic problem decouples the subdomain equations, allowing their independent solution for the next time step. We show numerical results that demonstrate the proposed method’s efficacy in achieving both ROM-FEM and ROM-ROM coupling.

de Castro, Amy↗

A graphene edge-mediated quantum gate

We propose a quantum gate architecture that allows for the systematic control of the effective exchange interactions between magnetic impurities embedded in nanoscale graphene flakes connected by a gated bridge. The entanglement between the magnetic moment and the edge states of the fragments is used to electrostatically tune the exchange interaction from ferro to antiferromagnetic by merely changing the bridge's carrier density. By characterizing the effects of size and coupling parameters, we explore different operation regimes of this device by means of exact calculations with the density matrix renormalization group. We analyze the results utilizing a simplified model that accounts for the main many-body mechanisms. Finally, we discuss how to use arrays of these devices to build quantum simulators for quantum many-body Hamiltonians.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic Performance Comparison and Prediction based on Distribution-level Phasor Measurement Units

This paper introduces a new distribution level Phasor Measurement Unit (PMU) which adopts advanced hardware components and structure. The hardware parameters from the new PMU and the existing PMU are used to build a simulation model to predict the PMU performance. Therefore, a real-world testbench is built and four distribution level PMUs are tested under the steady-state and dynamic tests. The quantitative experiment result confirms the prediction model which could guide future PMU design, and also verifies the accuracy of the new PMU on the synchrophasor and frequency measurements in multiple scenarios.

Wu, Yuru↗

A Contextually Supervised Optimization-Based HVAC Load Disaggregation Methodology

This paper presents a novel contextually supervised optimization-based approach for disaggregating heating, ventilation, and air-conditioning (HVAC) loads using smart meter or Supervisory Control and Data Acquisition data. To disaggregate the load into HVAC loads, large and infrequently used loads (LIUL), and base loads, we formulate an optimization problem to minimize a set of five loss terms, consisting of the reconstruction errors of the overall load profile, the ramp rate losses, and three distinct loss functions linked with the HVAC load, base load, and LIUL, respectively. To enhance accuracy, we incorporate two forms of contextual information into the problem formulation. First, we utilize mutual information to estimate HVAC energy consumption. Second, we employ a base load dictionary to constrain HVAC load estimation errors. The obtained HVAC load profiles are fine-tuned by abnormal ramp detection followed by binary hypothesis testing. Here, the proposed method is developed and tested using sub-metered residential and commercial building data. Simulation results show that the proposed method outperforms existing methods across various data resolutions and load aggregation levels, showing excellent transferability and generalizability.

24 POWER TRANSMISSION AND DISTRIBUTION↗