Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Conceptual design report: a ring-based electron cooling system for the EIC

This report describes a concept of an EIC cooling system, based on a proven induction-linac technology with a DC electron beam. The system would operate in a full energy range of proton beams (100–270 GeV) and would provide 50–100 A electron beams, circulating in a cooler ring for 5 ms. Every 5 ms a new electron pulse would be injected into the cooler ring to provide continuous cooling at collisions. Operations with a 10-ms cycle is possible but it will reduce the cooling rates by ~30%. The system is capable of delivering the required performance in the entire EIC energy range with emittance cooling times of less than 1–2 hours.

43 PARTICLE ACCELERATORS↗

Imaging Carrier Dynamics and Transport in Hybrid Perovskites with Transient Absorption Microscopy

In this review, the recent progress in using transient absorption microscopy to image charge transport and dynamics in semiconducting hybrid organic–inorganic perovskites is discussed. The basic principles, instrumentation, and resolution of transient absorption microscopy are outlined. With temporal resolution as high as 10 fs, sub-diffraction-limit spatial resolution, and excited-state structural resolution, these experiments have provided crucial details on charge transport mechanisms that have been previously obscured in conventional ultrafast spectroscopy measurements. Morphology-dependent mapping unveils spatial heterogeneity in carrier recombination and cooling dynamics. By spatially separating the pump and probe beams, carrier transport across grain boundaries has been directly visualized. Further, femtosecond temporal resolution allows for the examination of nonequilibrium transport directly, revealing extraordinarily long-range hot carrier migration. The application of transient absorption microscopy is not limited to hybrid perovskites but can also be useful for other polycrystalline materials in which morphology plays an important role in carrier transport.

36 MATERIALS SCIENCE↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma-based particle sources

High-brightness particle beams generated by advanced accelerator concepts have the potential to become an essential part of future accelerator technology. In particular, high-gradient accelerators can generate and rapidly accelerate particle beams to relativistic energies. The rapid acceleration and strong confining fields can minimize irreversible detrimental effects to the beam brightness that occur at low beam energies, such as emittance growth or pulse elongation caused by space charge forces. Due to the high accelerating gradients, these novel accelerators are also significantly more compact than conventional technology. Advanced accelerators can be extremely variable and are capable of generating particle beams with vastly different properties using the same driver and setup with only modest changes to the interaction parameters. So far, efforts have mainly been focused on the generation of electron beams, but there are concepts to extend the sources to generate spin-polarized electron beams or positron beams. The beam parameters of these particle sources are largely determined by the injection and subsequent acceleration processes. Although, over the last decade there has been significant progress, the sources are still lacking a sufficiently high 6-dimensional (D) phase-space density that includes small transverse emittance, small energy spread and high charge, and operation at high repetition rate. This is required for future particle colliders with a sufficiently high luminosity or for more near-term applications, such as enabling the operation of free-electron lasers (FELs) in the X-ray regime. Major research and development efforts are required to address these limitations in order to realize these approaches for a front-end injector for a future collider or next-generation light sources. In particular, this includes methods to control and manipulate the phase-space and spin degrees-of-freedom of ultrashort plasma-based electron bunches with high accuracy, and methods that increase efficiency and repetition rate. These efforts also include the development of high-resolution diagnostics, such as full 6D phase-space measurements, beam polarimetry and high-fidelity simulation tools. A further increase in beam luminosity can be achieve through emittance damping. Emittance cooling via the emission of synchrotron radiation using current technology requires kilometer-scale damping rings. For future colliders, the damping rings might be replaced by a substantially more compact plasma-based approach. Here, plasma wigglers with significantly stronger magnetic fields are used instead of permanent-magnet based wigglers to achieve similar damping performance but over a two orders of magnitude reduced length.

43 PARTICLE ACCELERATORS↗

Oakridge PPU Magnets: Results and Measurements

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) is being upgraded from 1.0 GeV to 1.3 GeV (or 1.4 to 2.8 MW). Several water-cooled magnets have been upgraded to transport 30% higher beam energy. Fermilab contributed the magnet design for the new chicane magnets and injection/extraction septum. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field so as not to disturb the circulating beam. After fabrication of the magnets, an extensive measurement campaign was developed and performed at Fermilab’s Magnet Test Facility. The measurements needed to assess magnet performance and provide comparison to design calculations. These included verification of field strength and harmonics along an 8 m length and 200 mm good field diameter for the chicane dipoles, end-field Hall probe mapping of these magnets, and measurements along two differently curved trajectories within the ∼3 m septum gradient magnet. Details of the measurements and systems are presented along with results and comparison to field models.

DiMarco, J. [Fermilab] (ORCID:0000000228400036)↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solving Critical Problems of the Muon Collider Higgs Factory: Optics, Magnets and their Protection, Detector Backgrounds

A low-energy medium-luminosity Muon Collider (MC) is being studied as a possible Higgs Factory (HF). Electrons from muon decays will deposit more than 300 kW in superconducting magnets of the HF collider ring. This imposes significant challenges to superconducting (SC) magnets used in the MC storage ring (SR) and interaction regions (IR). Magnet designs are proposed which provide high operating gradient and magnetic field in a large aperture to accommodate the large size of muon beams (due to low beta*), as well as a cooling system to intercept the large heat deposition from the showers induced by decay electrons. The distribution of heat deposition in the MC SR lattice elements requires large-aperture magnets in order to accommodate thick high-Z absorbers to protect the SC coils. Based on the developed MARS15 model and intensive simulations, a sophisticated radiation protection system was designed for the collider SR and IR to bring the peak power density in the superconducting coils below the quench limit and reduce the dynamic heat deposition in the cold mass by a factor of 100. The system consists of tight tungsten masks in the magnet interconnect regions and elliptical tungsten liners in the magnet aperture optimized individually for each magnet. These also reduce the background particle fluxes in the collider detector.

43 PARTICLE ACCELERATORS↗

Testing of Helium Cooled Metal Molybdenum Disk Target System

NorthStar Medical Radioisotopes LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through a photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess as high a tensile strength as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and the high thermal stress from beam heating.

42 ENGINEERING↗

Proposed Longitudinal Profile Diagnostics for Optical Stochastic Cooling of Stored Electrons in the IOTA Ring

One of the predicted signatures of successful optical stochastic cooling (OSC) in the Fermilab Integrable Optics Test Accelerator (IOTA) ring is reduction of the bunch length. The IOTA OSC experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps*. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam. A similar measurement was previously performed at the Advanced Photon Source with a Hamamatsu C5680 synchroscan streak camera operating at 117.3 MHz**. In this case, synchronous summing of OSR resulted in a bunch length measurement of 276 ± 30 ps using only 57 electrons circulating at 425 MeV. At IOTA, an existing streak camera has been modified to operate at the 11th harmonic of the ring’s revolution frequency of 7.50 MHz and has been installed on an OSR port in support of the OSC experiments. The integrated system will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.

Lumpkin, Alex H.↗

Tolerance Studies for the IMCC Rectilinear 6D Ionization Cooling Channel

As one of the main proposed future colliders that will enable us to reach energy scales capable of probing Beyond the Standard Model phenomena, muon colliders present unique challenges. To reach the desired luminosity, namely 1, 10, and 20 ab-1 for 3, 10, and 14 TeV, respectively, the six-dimensional emittance of the muon beam needs to be reduced significantly in a process described as muon cooling. The currently proposed system for muon cooling by the International Muon Collider Collaboration involves 6D initial cooling post-muon charge separation through rectilinear channels (A) before and rectilinear channels (B) after muon bunch merge, as well as a final 4D transverse cooling. This work focuses on the former stage of cooling with B rectilinear channels. First, we will compare its cooling performance against the rectilinear channel studied by the Muon Accelerator Program. Then, we do tolerance studies on all B stages, focusing on properties of the Radiofrequency (RF) cavities used in the channels and how they affect 6D emittance and transmission. We will evaluate the impact of these modifications on the overall performance of the rectilinear 6D cooling channel.

Karaaslan, Inci [Chicago U., EFI] (ORCID:000000033↗

Design and demonstration of an economical SRF structure for Continuous Wave (CW), high-energy, Megawatt-class beams

Due to its very high RF-to-beam efficiency, superconducting radiofrequency (SRF) cavities have become the technology of choice for the construction of large linear accelerators (linacs) for basic science applications (examples, ESS and PIP-II). The technology is also attractive for high volume industrial applications such as electron irradiation processing of wastewater and flue gas. However, SRF’s current reliance on liquid helium for cryogenic cooling introduces infrastructural and safety challenges for use in industrial settings. Cryocooler conduction-cooling is a recently developed novel technique for operating SRF cavities without requiring liquid helium. This project aims for technical design and economic assessment of a medium energy, high average power e-beam linac based on the conduction-cooled SRF technique for high volume irradiation treatment of wastewater. The goals of this project are (1) to design a medium energy (10 MeV), high average power (1 MW) electron beam accelerator around the cryocooler conduction-cooled SRF cavity technology, (2) demonstrate the required accelerating voltage on a prototype cavity, and (3) build a cost-model to evaluate capital and operating expense of the accelerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Positron Injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the CEBAF at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam 1 mA, 130-370 MeV, and 90% longitudinal polarization that passes through a rotating, water-cooled, tungsten target. The simulations for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are performed, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, 1.2 mm bunch length and normalized emittance of 100 mm·mrad). The impact of target thickness, electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated. Target thermal and structural FEM analyses (ANSYS Fluent) are performed to determine the maximum electron beam current and minimum transverse beam size on the target.

Benesch, Jay [Thomas Jefferson National Accelerato↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Simulations of positron injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130‑370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The simulation results for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are presented, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, <1 mm bunch length and normalized emittance of <100 mm mrad). The impact of target thickness, drive electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated.

Accelerator Physics↗

Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Heavy neutral leptons at beam dump experiments of future lepton colliders

A new beam dump experiment that utilizes the beam of future high energy electron-positron colliders could be an excellent avenue to search for dark sector particles due to its unprecedented high energy and intensity. We consider heavy neutral leptons (HNLs) as a specific example to demonstrate the sensitivity of searches for dark sector particles at future electron-positron collider beam dump experiments. This includes the study of the reach at the International Linear Collider (ILC), the Cool Copper Collider (C 3 ), and the Compact Linear Collider (CLIC). We comprehensively examine the HNL production and detector acceptance at these electron beam dump experiments. We show that these experiments will probe regions of HNL parameter space, not yet probed by past experiments, as well as by future approved experiments. Our study also motivates a more detailed analysis of heavy meson productions in high-energy electron-nucleon collisions in thick targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗