Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Analysis of Skeletal Muscle Metrics as Predictors of Functional Task Performance

PURPOSE: The ability to predict task performance using physiological performance metrics is vital to ensure that astronauts can execute their jobs safely and effectively. This investigation used a weighted suit to evaluate task performance at various ratios of strength, power, and endurance to body weight. METHODS: Twenty subjects completed muscle performance tests and functional tasks representative of those that would be required of astronauts during planetary exploration (see table for specific tests/tasks). Subjects performed functional tasks while wearing a weighted suit with additional loads ranging from 0-120% of initial body weight. Performance metrics were time to completion for all tasks except hatch opening, which consisted of total work. Task performance metrics were plotted against muscle metrics normalized to "body weight" (subject weight + external load; BW) for each trial. Fractional polynomial regression was used to model the relationship between muscle and task performance. CONCLUSION: LPMIF/BW is the best predictor of performance for predominantly lower-body tasks that are ambulatory and of short duration. LPMIF/BW is a very practical predictor of occupational task performance as it is quick and relatively safe to perform. Accordingly, bench press work best predicts hatch-opening work performance.

Ryder, Jeffrey W.↗

A Better ARED Squat

The 0-G ARED squat under loads the legs relative to the 1g ARED squat. In 1g the knee extensor/flexor muscles are primarily engaged due to the body's center of gravity is behind the knees during the motion of the squat. As body weight does not play a sufficient role 0 G, a crewmember's load exposure is limited by the load delivered by ARED through the exercise bar. Prescription loads for lowerbody resistance exercise in microgravity aim to include 1-G exercise bar load in addition to the crewmember's Earth body weight (BW); however, pressure points from the bar and the 1BW increased load at the shoulders translating to higher loads on the back have been a historical limitation for shoulders, requiring a decrease in exercise load at the start of the mission. Analogous to crewmembers, bed rest subjects report limitations of exercising with high loads on the back while performing squats on the horizontal exercise fixture (HEF), a custom exercise device that serves as an analog to 0-G ARED. Improvements for increasing loads on the HEF squat were suggested by distributing total exercise load between the hips and the bar1. The same is recommended for the 0-G ARED squat, with using current equipment on the ISS, which include the T2 running harness and T2 bungees. Quantification of this improvement has been accessed through computational modeling. The purpose of this study is to characterize joint torque during a squat with a distribution in exercise load on the ARED in 0 G. The analysis used existing models from NASA's Digital Astronaut Project. The biomechanics squat model was integrated with the ARED model and T2 bungees. The spring constant for the bungees were derived from ground testing. Forward dynamic simulation was performed for various conditions including anchor point attachments on the footplate of the ARED, bar load, hip load, and gravitational environment. The model confirms joint torques at knees is lower relative to 1G conditions primarily because the load delivery system is just with the exercise bar in 0 G. By distributing partial loads through use of the bungees to the hips joint-torque profiles were altered during a squat and provided options to enhance targeting lower-body loading in aims as for an improved countermeasure.

Caldwell, E. E.↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

Lidar Observations Revealing Transport of O3 in the Presence of a Nocturnal Low-Level Jet: Regional Implications for "Next-Day" Pollution

Remotely sensed profiles of ozone (O3) and wind are presented continuously for the first time during anocturnal low-level jet (NLLJ) event occurring after a severe O3 episode in the Baltimore-Washington D.C.(BW) urban corridor throughout 11-12 June 2015. High-resolution O3 lidar observations indicate a well mixedand polluted daytime O3 reservoir, which decayed into a contaminated nocturnal residual layer(RL) with concentrations between 70 and 100 ppbv near 1 km above the surface. Observations indicatethe onset of the NLLJ was responsible for transporting polluted O3 away from the region, while simultaneouslyaffecting the height and location of the nocturnal residual layer. High-resolution modelinganalyses and next-day (12 June) lidar, surface, and balloon-borne observations indicate the trajectory ofthe NLLJ and polluted residual layer corresponds with ''next-day'' high O3 at sites throughout thesouthern New England region (New York, Connecticut, Massachusetts). The novel O3 lidar observationsare evidence of both nocturnal advection (via high NLLJ wind fields) and entrainment of the pollutedresidual layer in the presence of the ''next-day'' convectively growing boundary layer. In the greatercontext, the novel observational suite described in this work has shown that the chemical budget in areasdownwind of major urban centers can be altered significantly overnight during transport events such asthe NLLJ.

ozone↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam↗

Crew State and Risk Model Development to Predict Hydration Status During Extravehicular Activity Training Events

Introduction: Hydration is critical for optimal human health and performance and dehydration can lead to impaired cardiovascular function, thermal dysregulation, decreased blood plasma volume, and cognitive impacts, particularly during physical activity. Prolonged and repeated extravehicular activities (EVA) without sufficiently available drinking water may increase risk for dehydration, which could impair crew health and impact mission success. Understanding hydration needs and potential effects on health and performance are necessary to optimize crew well-being and enable successful EVA objectives. This study aims to develop a model of hydration status during EVA using water balance techniques. Methods: Water balance measures were collected on 15 healthy astronauts who performed ≈6-hour simulated microgravity extravehicular activity (EVA) training in the NASA Neutral Buoyancy Laboratory (NBL). Data collected included pre-and post-EVA nude body weight (BW), maximum absorption garment (MAG) weight, Disposable In-suit Drink Bag (DIDB) weight, urine specific gravity (USG), and extra pre-EVA intake (W). Variables were combined to create the water balance model as pre-EVA (Hn)= BWn+ MAGn+ DIDBn+ Wnand post EVA (Hn+1) = BWn+1+ MAGn+1+ DIDBn+1. Urine specific gravity values were used to refine water balance measures into hydration categories: Hydrated, Marginally Hydrated, and Dehydrated. Results: Pre-EVA modeling indicated53% of crew were hydrated, 20% were marginally hydrated, and 27% were dehydrated. Alternately, Hn+1 showed 13% of crew remained hydrated, 47% were marginally hydrated, and 40% were dehydrated at the end of the EVA. Furthermore, 75% of the crewmembers who started sufficiently hydrated finished the run marginally hydrated or dehydrated. According to USG indices presented by Casa and Lawrence, et al. (2000), only 25% of the crew started and remained hydrated throughout the EVA, and those who were dehydrated at the outset stayed dehydrated. Conclusion: Model outcomes assessing hydration status during 6-hour simulated microgravity EVAs demonstrate the necessity to further address hydration requirements for optimal human performance during spaceflight and EVA. This study enables additional baseline development of the Crew State and Risk Model Hydration, Nutrition, and Waste Management component that aims to provide individualized crew state and risk predictions during EVAs. Reference: Casa, D. J., Armstrong, L. E., et al. (2000). National Athletic Trainers’ Association Position Statement: Fluid Replacement for Athletes. Journal of Athletic Training, 35:212-224.

L Cooper↗

PID techniques: Alternatives to RICH Methods

In this review article we discuss the recent progress in PID techniques other than the RICH methods. In particular we mention the recent progress in the Transition Radiation Detector (TRD), dE/dx cluster counting, and Time Of Flight (TOF) techniques. The TRD technique is mature and has been tried in many hadron colliders. It needs space though, about 20cm of detector radial space for every factor of 10 in the {pi}/e rejection power, and this tends to make such detectors large. Although the cluster counting technique is an old idea, it was never tried in a real physics experiment. Recently, there are efforts to revive it for the SuperB experiment using He-based gases and waveform digitizing electronics. A factor of almost 2 improvement, compared to the classical dE/dx performance, is possible in principle. However, the complexity of the data analysis will be substantial. The TOF technique is well established, but introduction of new fast MCP-PMT and G-APD detectors creates new possibilities. It seems that resolutions below 20-30ps may be possible at some point in the future with relatively small systems, and perhaps this could be pushed down to 10-15ps with very small systems, assuming that one can solve many systematic issues. However, the cost, rate limitation, aging and cross-talk in multi-anode devices at high BW are problems. There are several groups working on these issues, so progress is likely. Table 6 summarizes the author's opinion of pros and cons of various detectors presented in this paper based on their operational capabilities. We refer the reader to Ref.40 for discussion of other more general limits from the PID point of view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lattice design and optimization for the PEP-X ultra low emittance storage ring at SLAC

SLAC is developing a long-range plan to transfer the evolving scientific programs at SSRL from the SPEAR3 light source to a much higher performing photon source. One of the possibilities is a new PEP-X 4.5 GeV storage ring that would be housed in the 2.2 km PEP-II tunnel. The PEP-X is designed to produce photon beams having brightness near 10{sup 22} (ph/s/mm{sup 2}/mrad{sup 2}/0.1% BW) at 10 keV with 3.5 m undulator at beam current of 1.5 A. This report presents an overview of the PEP-X baseline lattice design and describes the lattice optimization procedures in order to maximize the beam dynamic aperture. The complete report of PEP-X baseline design is published in SLAC report.

43 PARTICLE ACCELERATORS↗

Precision X-Band Linac Technologies for Nuclear Photonics Gamma-Ray Sources

Nuclear photonics is an emerging field of research requiring new tools, including high spectral brightness, tunable gamma-ray sources; high photon energy, ultrahigh-resolution crystal spectrometers; and novel detectors. This presentation focuses on the precision linac technology required for Compton scattering gamma-ray light sources, and on the optimization of the laser and electron beam pulse format to achieve unprecedented spectral brightness. Within this context, high-gradient X-band technology will be shown to offer optimal performance in a compact package, when used in conjunction with the appropriate pulse format, and photocathode illumination and interaction laser technologies. The nascent field of nuclear photonics is enabled by the recent maturation of new technologies, including high-gradient X-band electron acceleration, robust fiber laser systems, and hyper-dispersion CPA. Recent work has been performed at LLNL to demonstrate isotope-specific detection of shielded materials via NRF using a tunable, quasi-monochromatic Compton scattering gamma-ray source operating between 0.2 MeV and 0.9 MeV photon energy. This technique is called Fluorescence Imaging in the Nuclear Domain with Energetic Radiation (or FINDER). This work has, among other things, demonstrated the detection of {sup 7}Li shielded by Pb, utilizing gamma rays generated by a linac-driven, laser-based Compton scattering gamma-ray source developed at LLNL. Within this context, a new facility is currently under construction at LLNL, with the goal of generating tunable {gamma}-rays in the 0.5-2.5 MeV photon energy range, at a repetition rate of 120 Hz, and with a peak brightness in the 10{sup 20} photons/(s x mm{sup 2} x mrad{sup 2} x 0.1% bw).

42 ENGINEERING↗

Search for Pair Production of a Heavy Up-Type Quark Decaying to a W Boson and a b Quark in the lepton plus jets Channel with the ATLAS Detector

A search is presented for production of a heavy up-type quark (t{prime}) together with its antiparticle, assuming subsequent decay to a W boson and a b quark, t{prime}{bar t}{prime} {yields} W{sup +}bW{sup -}{bar b}. The search is based on 1.04 fb{sup -1} of proton-proton collisions at {radical}s = 7 TeV collected by the ATLAS detector at the CERN Large Hadron Collider. Data are analyzed in the lepton+jets final state, characterized by a high transverse momentum isolated electron or muon, high missing transverse momentum, and at least three jets. No significant excess of events above the background expectation is observed. A 95% C.L. lower limit of 404 GeV is set for the mass of the t{prime} quark.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charged Higgs Probes of Dark Bosons at the LHC

A very light (GeV scale) dark gauge boson (Z') is a recently highlighted hypothetical particle that can address some astrophysical anomalies as well as the 3.6σ deviation in the muon g-2 measurement. We suggest top quark decays as a venue to search for light dark force carriers at the LHC. Such Z's can be easily boosted, and they can decay into highly collimated leptons (lepton-jet) with large branching ratio. We investigate a scenario where a top quark decays to bW accompanied by one or multiple dark force carriers and find that such a scenario could be easily probed at the early stage of LHC Run 2.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of NSLS-II

NSLS-II, the new 3rd generation light source at BNL was designed for a brightness of 10 22 photons s -1 mm -2 mrad -2 (0.1%BW) -1 . It was constructed between 2009 and 2014. The storage ring was commissioned in April 2014 which was followed by insertion device and beamline commissioning in the fall of 2014. All ambitious design parameters of the facility have already been achieved except for commissioning the full beam intensity of 500mA which requires more RF installation. This paper reports on the results of commissioning.

43 PARTICLE ACCELERATORS↗

Channeling Radiation Experiment at Fermilab ASTA

Electron beams with moderate energy ranging from 4 to 50 MeV can be used to produce x-rays through the Channeling Radiation (CR) mechanism. Typically, the xray spectrum from these sources extends up to 140 keV and this range covers the demand for most practical applications. The parameters of the electron beam determine the spectral brilliance of the x-ray source. The electron beam produced at the Fermilab new facility Advanced Superconducting Test Accelerator (ASTA) meets the requirements to assemble an experimental high brilliance CR xray source. In the first stage of the experiment the energy of the beam is 20 MeV and due to the very low emittance ($\approx 100$ nm ) at low bunch charge (20 pC) the expected average brilliance of the x-ray source is about $10^9$ photons/[s- $(mm-mrad)^2$-0.1% BW]. In the second stage of the experiment the beam energy will be increased to 50 MeV and consequently the average brilliance will increase by a factor of five. Also, the x-ray spectrum will extend from about 30 keV to 140 keV

Mihalcea, D.↗

Validation of fumonisin biomarkers in F344 rats

Fumonisins (FNs) are ubiquitous contaminants of cereal grains. Fumonisin B{sub 1} (FB{sub 1}) was linked to several animal and human diseases. To validate FB{sub 1} biomarkers for studying human disease risks, F344 rats were administered by gavage with either a single dose of 0, 10 or 25 mg FB{sub 1}/kg body weight (BW) or repeated doses of 0, 1.0, or 2.5 mg FB{sub 1}/kg BW/day for 5 weeks. FB{sub 1} excretion and FB{sub 1}-induced metabolic alterations of sphingolipids in rat urine, feces and serum were assessed. Dose-dependent urinary and fecal excretion of free FB{sub 1} were found in both single-dose- and repeat-dose-treated rats. In the single-dose study, urinary sphinganine (Sa) to sphingosine (So) ratio (Sa/So) reached a maximum at day 7 for the high-dose group and at day 5 for the low-dose group, whereas serum Sa/So showed only marginal changes. In the repeat-dose study, urinary Sa/So was persistently elevated at 2 weeks, while serum Sa/So was unchanged. Time course changes of sphinganine 1-phosphate (SaP) and sphingosine 1-phosphate (SoP) were also examined. Although serum Sa/So and SaP/SoP ratios showed no signs of time- or dose-dependent changes, a 10-fold increase in urinary SaP/SoP was observed, suggesting that urinary SaP/SoP is a more sensitive biomarker for FB{sub 1} exposure. The accumulation of SaP and SoP was evident in the time course of SaP/Sa and SoP/So, which may reflect activity changes of enzymes closely related to the metabolism and catabolism of SaP and SoP. These results provide concrete evidence towards the practical use of excreted FB{sub 1}, Sa/So and SaP/SoP as biomarkers of exposure to FNs.

60 APPLIED LIFE SCIENCES↗

The effects of deoxynivalenol on gene expression in the murine thymus

Deoxynivalenol (DON) is a mycotoxin produced by several Fusarium species and is often detected in grains. Because of its high abundance, there has been a large interest in the effects of DON in animals and humans. DON is known to be immunosuppressive at high concentrations and immunostimulatory at low concentrations. The present study aimed to acquire insight into the modes of action of DON. For this, C57Bl6 mice were orally exposed to 5, 10, or 25 mg/kg bw DON for 3, 6, or 24 h and thymuses were subjected to genome-wide expression microarray analysis. Gene set enrichment analysis (GSEA) demonstrated that DON downregulated genes involved in proliferation, mitochondria, protein synthesis, and ribosomal proteins. Furthermore, GSEA showed a selective downregulation of genes highly expressed at the early precursor thymocytes stage. This indicates that early precursor thymocytes, particularly at the double-positive CD4+CD8+ stage, are more vulnerable to DON than very early or late precursor thymocytes. There was a large overlap of genes upregulated by DON with genes previously reported to be either upregulated during T cell activation or upregulated during negative selection of thymocytes that recognize 'self-antigens'. This indicates that DON induces cellular events that also occur after activation of the T cell receptor, for example, release of calcium from the endoplasmatic reticulum. This T cell activation in the thymus then evokes negative selection and depletion of thymocytes, which provides a plausible explanation for the high sensitivity of the thymus for DON exposure. The expression patterns of four genes indicative for some of the processes that were affected after DON treatment were confirmed using real-time PCR. Immunocytological experiments with primary mouse thymocytes demonstrated the translocation of NFAT from the cytoplasm into the nucleus upon exposure top DON, thus providing further evidence for the involvement of T cell activation.

60 APPLIED LIFE SCIENCES↗

Methyl-parathion decreases sperm function and fertilization capacity after targeting spermatocytes and maturing spermatozoa

Paternal germline exposure to organophosphorous pesticides (OP) has been associated with reproductive failures and adverse effects in the offspring. Methyl parathion (Me-Pa), a worldwide-used OP, has reproductive adverse effects and is genotoxic to sperm. Oxidative damage has been involved in the genotoxic and reproductive effects of OP. The purpose of this study was to determine the effects of Me-Pa on spermatozoa function and ability to fertilize. Male mice were exposed to Me-Pa (20 mg/kg bw, i.p.) and spermatozoa from epididymis-vas deferens were collected at 7 or 28 days post-treatment (dpt) to assess the effects on maturing spermatozoa and spermatocytes, respectively. DNA damage was evaluated by nick translation (NT-positive cells) and SCSA (percentDFI); lipoperoxidation (LPO) by malondialdehyde production; sperm function by spontaneous- and induced-acrosome reactions (AR); mitochondrial membrane potential (MMP) by using the JC-1 flurochrome; and, fertilization ability by an in vitro assay and in vivo mating. Results showed alterations in DNA integrity (percentDFI and NT-positive cells) at 7 and 28 dpt, in addition to decreased sperm quality and a decrease in induced-AR; reduced MMP and LPO was observed only at 7 dpt. We found negative correlations between LPO and all sperm alterations. Altered sperm functional parameters were associated with reduced fertilization rates at both times, evaluated either in vitro or in vivo. These results show that Me-Pa exposure of maturing spermatozoa and spermatocytes affects many sperm functional parameters that result in a decreased fertilizing capacity. Oxidative stress seems to be a likely mechanism ofthe detrimental effects of Me-Pa in male germ cells.

59 BASIC BIOLOGICAL SCIENCES↗

Concepts for the PEP-X Light Source

SSRL and SLAC groups are developing a long-range plan to transfer its evolving scientific programs from the SPEAR3 light source to a much higher performing photon source that would be housed in the 2.2-km PEP-II tunnel. While various concepts for the PEP-X light source are under consideration, including ultimate storage ring and ERL configurations, the present baseline design is a very low-emittance storage ring. A hybrid lattice has double bend achromat (DBA) cells in two of the six arcs that provide a total 30 straight sections for insertion device (ID) beam lines extending into two new experimental halls. The remaining arcs contain TME cells. Using 90 m of damping wigglers the horizontal emittance at 4.5 GeV would be 100 pm-rad with 1.5-A stored beam. PEP-X will produce photon beams having brightnesses near 10{sup 22} (ph/s/mm{sup 2}/mrad{sup 2}/0.1% BW) at 10 keV. Studies indicate that a 90-m undulator could have FEL gain and brightness enhancement at soft x-ray wavelengths with the stored beam. Crab cavities or other beam manipulation systems could be used to reduce bunch length or otherwise enhance photon emission properties. The present status of the design of PEP-X as a storage ring is presented.

XFEL↗