Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BUBBLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Ring Bubbles of Dolphins

The article discusses how dolphins create and play with three types of air-filled vortices. The underlying physics is discussed. Photographs and sketches illustrating the dolphin's actions and physics are presented. The dolphins engage in this behavior on their own initiative without food reward. These behaviors are done repeatedly and with singleminded effort. The first type is the ejection of bubbles which, after some practice on the part of the dolphin, turn into toroidal vortex ring bubbles by the mechanism of baroclinic torque. These bubbles grow in radius and become thinner as they rise vertically to the surface. One dolphin would blow two in succession and guide them to fuse into one. Physicists call this a vortex reconnection. In the second type, the dolphins first create an invisible vortex ring in the water by swimming on their side and waving their tail fin (also called flukes) vigorously. This vortex ring travels horizontally in the water. The dolphin then turns around, finds the vortex and injects a stream of air into it from its blowhole. The air "fills-out" the core of the vortex ring. Often, the dolphin would knock-off a smaller ring bubble from the larger ring (this also involves vortex reconnection) and steer the smaller ring around the tank. One other dolphin employed a few other techniques for planting air into the fluke vortex. One technique included standing vertically in the water with tail-up, head-down and tail piercing the free surface. As the fluke is waved to create the vortex ring, air is entrained from above the surface. Another technique was gulping air in the mouth, diving down, releasing air bubbles from the mouth and curling them into a ring when they rose to the level of the fluke. In the third type, demonstrated by only one dolphin, the longitudinal vortex created by the dorsal fin on the back is used to produce 10-15 foot long helical bubbles. In one technique she swims in a curved path. This creates a dorsal fin vortex since centrifugal force has to be balanced by a lift-like force. She then re-traces her path and injects air into the vortex from her blowhole. She can even make a ring reconnect from the helix. In the second technique, demonstrated a few times, she again swims in a curved path, releases a cloud or group of bubbles from her blowhole and turns sharply away (Which presumably strengthens the vortex). As the bubbles encounter the vortex, they travel to the center of the vortex, merge and, in a flash, elongate along the core of the vortex. In all the three types, the air-water interface is shiny smooth and stable because the pressure gradient in the vortex flow around the bubble stabilizes it. A lot of the interesting physics still remains to be explored.

Shariff, Karim↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer. respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting. distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receive, the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble Measuring Instrument and Method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Robert Kline-Schoder↗

Bubble measuring instrument and method

Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

Kline-Schoder, Robert↗

Capillary Channel Flow (CCF) EU2-02 on the International Space Station (ISS): An Experimental Investigation of Passive Bubble Separations in an Open Capillary Channel

It would be signicantly easier to design fluid systems for spacecraft if the fluid phases behaved similarly to those on earth. In this research an open 15:8 degree wedge-sectioned channel is employed to separate bubbles from a two-phase flow in a microgravity environment. The bubbles appear to rise in the channel and coalesce with the free surface in much the same way as would bubbles in a terrestrial environment, only the combined effects of surface tension, wetting, and conduit geometry replace the role of buoyancy. The host liquid is drawn along the channel by a pump and noncondensible gas bubbles are injected into it near the channel vertex at the channel inlet. Control parameters include bubble volume, bubble frequency, liquid volumetric flow rate, and channel length. The asymmetrically confined bubbles are driven in the cross-flow direction by capillary forces until they at least become inscribed within the section or until they come in contact with the free surface, whereupon they usually coalesce and leave the flow. The merging of bubbles enhances, but does not guarantee, the latter. The experiments are performed aboard the International Space Station as a subset of the Capillary Channel Flow experiments. The flight hardware is commanded remotely and continuously from ground stations during the tests and an extensive array of experiments is conducted identifying numerous bubble flow regimes and regime transitions depending on the ratio and magnitude of the gas and liquid volumetric flow rates. The breadth of the publicly available experiments is conveyed herein primarily by narrative and by regime maps, where transitions are approximated by simple expressions immediately useful for the purposes of design and deeper analysis.

fluid dynamics↗

Investigations of Bubbly Flows using Direct Numerical Simulations

Direct numerical simulations are used to examine the behavior of relatively high void fraction bubbly flows. The full Navier-Stokes equations are solved for both the bubbles and the ambient liquid and the flow near the moving and deforming phase boundaries is resolved fully. This yields detailed data for the evolution of the system that can be used to extract information about the basic bubble-bubble and bubble-flow interactions as well as about the averaged properties of the system. Such information are critical for the generation of averaged engineering models of industrial size systems as well as for novel applications of bubbly flows where experiments are difficult. The project has yielded detailed information about many aspects of bubbly flows. The results for flows in vertical channels are particularly significant and have yielded an essentially complete understanding of many aspects of the flows. The important insight is that the flow has a particularly simple structure, consisting of a homogeneous core in hydrostatic balance and a wall layer whose composition depends of whether the liquid is flowing upward or downward. These results hold for both laminar and turbulent flows and have allowed us to derive an analytical model to predict the flow. We have also shown that bubble deformability results in a completely different flow structure, but also giving rise to relatively simple predictive models. Preliminary studies of transient migration of a non-homogeneous bubble distribution and coalescence induced flow regime transitions in vertical channels were also done.

42 ENGINEERING↗

Nested bubbling apparatus

A device for bubbling a gas into a liquid is disclosed. The device comprises a first bubbling apparatus nested inside a second bubbling apparatus. The first bubbling apparatus comprises a gas inlet for receiving the gas and a plurality of first openings for releasing the gas. The second bubbling apparatus at least partially encloses the plurality of first openings of the first bubbling apparatus. The second bubbling apparatus receives the gas from the plurality of first openings. The second bubbling apparatus comprises a plurality of second openings for bubbling the gas into the liquid.

42 ENGINEERING↗

Effect of Recrystallization on Gas Bubble Swelling in UMo Fuels

The development of low-enriched uranium (LEU) fuels such as UMo dispersion fuels and monolithic UMo fuels is part of a global effort on nuclear nonproliferation. Although UMo fuels have the advantage of high density, excellent irradiation performance and good thermal conductivity, the volumetric swelling in irradiated metallic fuels is known to be an important design parameter because it affects not only the thermal conductivity of the fuels but also the mechanical integrity of fuel structures. Experiments also show that recrystallization dramatically affects the gas bubble swelling kinetics. A series of materials processes such as casting, mechanical rolling and thermal treatment are used in fuel fabrication. Resulting microstructure, such as grain size, porosity, and second phase, strongly depends on the material processes and process parameters. Therefore, a fundamental understanding how fabricated microstructures and irradiation conditions affect the nucleation of gas bubbles, recrystallization and gas bubble swelling kinetics is essential for optimizing material processes to obtain desired microstructure and fuel performance. Great effort has been made in the development of modeling capability for predicting gas bubble swelling kinetics and fission gas release kinetics in nuclear fuels. However, these models are based on the assumptions that the inter- and intra-granular gas bubble sizes are independent of position and only depend on time or fission density. Therefore, they are applicable to a material with uniform microstructure such as equiaxed grains with homogeneous defect distributions, homogeneous thermodynamic and kinetic properties of defects, and uniform radiation conditions. Very recently, we developed a three dimension (3D) microstructure dependent gas bubble swelling model for investigating the effect of heterogeneous microstructures and inhomogeneous thermodynamic properties of defects on gas bubble swelling in polycrystalline UMo fuels. However, the model doesn't take into account the effect of recrystallization on swelling kinetics. In this work, the spatially dependent rate theory is used to describe the evolution of interstitials and interstitial loop density. Recrystallization is described by a phase-field model with a concept of 'phase transition' when the local interstitial loop density is larger than a critical value. The intra- and inter- granular gas bubble evolution is described by the spatially dependent Booth model. A model integrating all the microstructure evolution enables one to study the effect of heterogeneous microstructures, recrystallization, and the metallic fuel thermodynamic and kinetic properties on gas bubble swelling kinetics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A hybrid discrete bubble-lattice Boltzmann–discrete element model for gas-charged sediments

In this paper, we present a hybrid discrete bubble-lattice Boltzmann–discrete element modelling framework for simulating gas-charged sediments, especially in the seabed. A discrete bubble model proposed in chemical engineering is adapted in the coupled discrete element/lattice Boltzmann method to model the migration of gas bubbles in saturated sediments involving interactions between gas bubbles and fluid/solid phases. Surface tension is introduced into the discrete bubble model in this work, so that it can handle the complex gas–fluid–solid interface. The lattice Boltzmann and discrete element methods are, respectively, employed to simulate fluid flows and mechanical behaviours of sediments. A velocity interpolation-based immerse boundary method is utilised to resolve the coupling between the fluid flow and the solid/gas phase. The proposed technique is preliminarily validated using simulations of bubble migration in fluids, which is followed by high-resolution investigations of the transport of a gas bubble in seabed sediments. Lastly, it is demonstrated that this hybrid method can reproduce, to a certain degree, the characters of bubbles moving in seabed sediment tests.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a mechanistic model for sliding bubbles growth prediction in subcooled boiling flow

In this paper, a new mechanistic model for predicting the growth of sliding bubbles in subcooled boiling flow has been developed. The basis of this model is the assumption that the fundamental heat transfer mechanisms acting on a stagnant bubble growing at a nucleation site can also be applied to the growth of sliding bubbles. The physical assumptions of the existing bubble growth models were modified to reflect the intrinsic physics associated with the sliding bubble growth. The heat transfer mechanisms considered are microlayer evaporation, evaporation of superheated liquid, and condensation. The present model has been successfully validated against a broad set of subcooled flow boiling data, generated by three separate research groups using different working fluids and different heater surfaces. The model successfully reproduced the sliding bubble growth dependencies on mass flux, wall superheat, and liquid subcooling level as observed in the experiments. Finally, on the other hand, in a few cases where the bubble growth inertia was substantially involved in the sliding bubble growth, the predictive ability was limited.

42 ENGINEERING↗

High-speed characterization of two-phase flow and bubble dynamics in titanium felt porous media for hydrogen production

Bubble dynamics and two-phase flow phenomena are closely related to the performance of proton exchange membrane electrolyzer cells (PEMECs). This paper reports an in-situ study of the oxygen bubble behavior and associated multiphase evolutions in the anode side of PEMECs with titanium (Ti) felt liquid gas diffusion layers (LGDLs) by a high-speed visualization system. The micro oxygen bubble dynamics was captured and analyzed at different locations and virous operating conditions. The results show that the bubble detachment frequency and detachment diameter greatly increase with the operating current density. Additionally, they are significantly impacted by the local pore structure and morphology of Ti felt LGDLs. In the flow channels, there exist only several discrete micro bubbles at a low current density (0.04 A/cm 2 ) and a large flow velocity (133 mm/s). At a current density (0.2 A/cm 2 ) and a flow velocity (67 mm/s), a number of gas slugs are formed in the follow channels, in addition to discrete micro bubbles. At a high current density (1 A/cm 2 ) and a flow velocity (67 mm/s), more bubbles appear in the channel, and the flow field is dominated by slug or annular flows. These investigations can help to better understand the two-phase flow and bubble detachment mechanism, and provide a foundation for electrochemical reaction, multiphase flow studies and optimize the design of gas diffusion layers and flow fields for PEMECs in the future.

08 HYDROGEN↗

Unraveling the Early-Stage Ordering of Krypton Solid Bubbles in Molybdenum: A Multimodal Study

Self-organization of defects such as fission gas bubbles in materials can lead to high inventory capacity for fission gas storage and help mitigate swelling caused by fission gases in nuclear fuel materials under radiation in nuclear reactors. Here, we report the physical mechanism of self-organization of krypton (Kr) gas bubbles in molybdenum (Mo) under ion implantation. The ion fluence and temperature-dependent formation of Kr solid bubble superlattice (SBS) in Mo were investigated by using both synchrotron-based small-angle X-ray scattering (SAXS) and transmission electron microscopy (TEM). Early stage self-organization of gas bubbles is observed at a fluence of 2.5 × 10 16 ions/cm 2 at temperatures of 300–400 °C. The bubble lattice constant increases with increasing implantation temperature from 300 to 400 °C. Both experiments and atomic kinetic Monte Carlo modeling indicate that the Kr solid bubbles are weakly ordered in comparison to previously studied helium (He) gas bubble superlattice (GBS) while the lattice constant are relatively smaller for Kr SBS compared to that of He GBS. The irradiation conditions suggest that spinodal decomposition, which is a form of phase separation, probably precedes gas bubble ordering in Mo. Altogether, our work sheds light on the formation mechanism of noble gas superlattice toward the development of radiation-tolerant materials which are important for the design of advanced nuclear reactors.

36 MATERIALS SCIENCE↗

The role of breakup and coalescence in fine-scale bubble-induced turbulence. I. Dynamics

We study the effect of bubble breakup and coalescence on fine-scale dynamics of bubbly turbulent flows using direct numerical simulations. We perform two different simulations of dilute bubbly flows of void fraction 0.5%: one with bubbles breaking up and coalescing and the other without these physical processes. The volume of the fluid method is used for simulating bubbles undergoing breakup and coalescence while the bubbles are treated as rigid spheres in the immersed boundary method simulation. The energy spectrum in both types of simulation, consistent with previous studies, exhibits a -3 slope. We follow a single infinitesimal fluid element as it evolves to understand velocity gradient dynamics using conditional mean trajectories. We note finite-time divergence when the fluid element evolves under the action of inertial and pressure dynamics. The inertial, pressure, and viscous velocity gradient dynamics, when considered individually, produce the same results for bubble-induced turbulence (BIT) as with the classical homogeneous isotropic turbulence (HIT). Yet when the overall velocity gradient dynamics is considered, BIT results in non-cyclic trajectories moving toward stable node and unstable saddle while classical HIT shows cyclic behavior in their trajectories that move toward the origin. Interestingly, both the volume of fluid and immersed boundary simulations produce similar results. Therefore, there are two main takeaways from this research. First, new velocity gradient models are needed for BIT as their velocity gradients behavior is entirely different from the HIT. Second, we can neglect the bubble topology, breakup, and coalescence while studying or modeling the fine-scale dynamics of BIT.

42 ENGINEERING↗

Simulation of Bubble Behavior in a Water Physical Model of an Aluminum Degassing Ladle Unit Employing Compound Technique of Rotary Blowing and Ultrasonic

A two-dimensional volume of fluid (VOF) model was developed to simulate the behavior of bubbles in a physical model of the aluminum degassing unit employing the compound technique of rotary blowing and ultrasonic. The effect of rotation speed on bubble behavior under rotating flow field, and the effects of ultrasonic parameters including the amplitude, length, and position of ultrasonic end-face on bubble behavior under compound field were analyzed according to the simulation results, respectively. The experiment shows the simulation results for the bubble shape and trajectory agree well with the experimental observations. Under single rotating flow field, the rotation speed has a strong impact upon bubble trajectory and the optimal speed is 450 rpm. Under compound field, ultrasonic can increase the number of broken bubbles, and push bubbles to further area, which is beneficial to strengthen the bubble distribution and improve the degassing effect. The appropriate amplitude, length, and position of ultrasonic end-face are 23 μm, 50 mm, and 185 mm.

36 MATERIALS SCIENCE↗

Bubble formation in helium-implanted nanostructured ferritic alloys at elevated temperatures

Helium bubble formation was examined by scanning/transmission electron microscopy (S/TEM) in Fe-9/10Cr binary alloys and two dispersion strengthened nanostructured alloys (CNA3 and 14YWT containing 5–10 nm diameter carbide and oxide particles, respectively) after ex-situ and in-situ He implantation to ~10,000 appm at 500 to 900 °C. The combination of high-resolution STEM images and electron energy loss spectroscopy (EELS) revealed that the Y-Ti-O nanoparticles in 14YWT were uniformly distributed and exhibited a one-to-one relationship for bubble attachment to the nanoclusters. In the in-situ experiment at 900 °C, grain boundary cracking was severe in the Fe-10Cr model alloy, but not in the nanostructured alloys. From 500 to 900 °C, the bubble size generally increased with increasing irradiation temperature, while the bubble density decreased with increasing temperature. At the same temperatures, the bubble size in the implanted materials was in the order of Fe-9/10Cr > CNA3 > 14YWT, while the bubble density showed the opposite order. The observed bubble number densities for the nanostructured alloys are comparable to the nanoparticle density, suggesting that the nanoparticles in both alloys were effective in trapping He. Overall, our results indicate that very high He concentrations can be managed in nanostructured alloys by sequestering the helium into smaller bubbles (which leads to a lower volume swelling value) and to shield He from the grain boundaries. This can be attributed to the much higher sink strength associated with the nanoclusters or the He trapping ability between different types of nanoclusters.

36 MATERIALS SCIENCE↗

Probing He bubbles in naturally aged and annealed δ-Pu alloys using ultra-small-angle x-ray scattering

We report the self-irradiation of Pu alloys generates He that is trapped within the metal matrix in the form of He bubbles. The distribution of these He bubbles in δ-phase Pu-Ga alloys exhibits a peak near a radius of 0.7 nm, and this size is remarkably stable as function of time. When annealed, the He bubbles in δ-Pu alloys grow, coarsening the distribution. However, the magnitude of this coarsening is uncertain, as different experimental methods reveal bubbles that differ by at least one order of magnitude. Small-angle x-ray scattering results, which can probe a wide range of bubble sizes, imply only a mild coarsening of the He bubble distribution for an annealing treatment of 425 °C for 24 h, and analysis of the He bubble content suggests that He is actually lost from the bubbles with annealing.

36 MATERIALS SCIENCE↗