Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOILING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Toughened polyester composites containing polyester matrix and droplets of high boiling liquid therein

A toughened polyester composite comprising: (i) a polyester matrix and (ii) droplets of a high boiling point liquid having a boiling point of at least 140° C. dispersed in said polyester matrix, wherein the high boiling point liquid is present in an amount of 0.1-10 wt % by weight of the toughened polyester composite, and wherein the composite may further include: (iii) a modifier selected from polycarboxylic, polyol, and polyamine compounds, wherein the modifier is present in an amount of 0.1-10 wt % by weight of the toughened polyester composite. Methods for producing the polyester composite are also described.

Ozcan, Soydan↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient↗

Wall Area of Influence and Growing Wall Heat Transfer due to Sliding Bubbles in Subcooled Boiling Flow

A variety of dynamical features of sliding bubbles and their impact on wall heat transfer were observed at subcooled flow boiling conditions in a vertical square test channel. Among the wide range of parameters observed, we particularly focus in this paper on (i) the sliding bubbles’ effect on wall heat transfer (supplemantry discussion to the authors’ previous work in Yoo et al. (2016a,b)) and (ii) the wall area influenced by sliding bubbles in subcooled boiling flow. At first, this study reveals that the degree of wall heat transfer improvement due to sliding bubbles depended less on the wall superheat condition as the mass flux increased. Also, the sliding bubble trajectory was found to be one of the critical factors in order to properly describe the wall heat transfer associated with sliding bubbles. In particular, the wall area influenced by sliding bubbles depended strongly on both sliding bubble trajectory and sliding bubble size; the sliding bubble trajectory was also observed to be closely related to the sliding bubble size. Importantly, these results indicate the limitation of current approach in CFD analyses especially for the wall area of bubble influence. In addition, the analyses on the temporal fraction of bubbles’ residence (FR) along the heated wall show that the sliding bubbles typically travel through narrow path with high frequency while the opposite was observed downstream. That is, both FR and sliding bubble trajectory depended substantially on the distance from nucleation site, which is expected to be similar for the quenching heat transfer mode induced by sliding bubbles.

42 ENGINEERING↗

Development of a mechanistic model for sliding bubbles growth prediction in subcooled boiling flow

In this paper, a new mechanistic model for predicting the growth of sliding bubbles in subcooled boiling flow has been developed. The basis of this model is the assumption that the fundamental heat transfer mechanisms acting on a stagnant bubble growing at a nucleation site can also be applied to the growth of sliding bubbles. The physical assumptions of the existing bubble growth models were modified to reflect the intrinsic physics associated with the sliding bubble growth. The heat transfer mechanisms considered are microlayer evaporation, evaporation of superheated liquid, and condensation. The present model has been successfully validated against a broad set of subcooled flow boiling data, generated by three separate research groups using different working fluids and different heater surfaces. The model successfully reproduced the sliding bubble growth dependencies on mass flux, wall superheat, and liquid subcooling level as observed in the experiments. Finally, on the other hand, in a few cases where the bubble growth inertia was substantially involved in the sliding bubble growth, the predictive ability was limited.

42 ENGINEERING↗

Augmentation of pool boiling heat transfer on tube bundles using metal foam

Pool boiling on a tube bundle is one of the most important heat transfer modes in several industrial applications, including steam generators, shell and tube heat exchangers for waste heat recovery, and desalination. Although several enhanced tubes (e.g., external micro-finned tubes) have been extensively studied and commercialized, the studies that pertain to the metal foam enhanced tube bundles are limited in the open literature. The objective of the present study is to perform an experimental study to analyze the pool boiling heat transfer characteristics of a metal foam tube bundle and compare its performance with that of a tube bundle with no enhancement. The performance of the metal foam tube bundles with different porosities (81%, 75%, and 62%) is compared against the conventional bare tube bundle. The results showed that the heat transfer coefficients of the metal foam tube bundles are 100–212% higher than those of the bare tube bundle. Among the different porosities, metal foam with 75% porosity showed a higher heat transfer coefficient. Furthermore, the wall temperature of the metal foam tubes is nearly 5–14⁰C lower than that of the bare tubes. In conclusion, when compared with a tube pitch of 25.4 mm, a tube pitch of 19.05 mm showed a maximum of 9% and 14% enhancement in bare and metal foam tube bundles, respectively.

42 ENGINEERING↗

Prediction of heat transfer coefficients for forced convective boiling of N 2 -hydrocarbon mixtures at cryogenic conditions using artificial neural networks

A key problem faced in the design of heat exchangers, especially for cryogenic applications, is the determination of convective heat transfer coefficients in two-phase flow such as condensation and boiling of non-azeotropic refrigerant mixtures. Here, this paper proposes and evaluates three models for estimating the convective coefficient during boiling. These models are developed using computational intelligence techniques. The performance of the proposed models is evaluated using the mean relative error (mre), and compared to two existing models: the modified Granryd’s correlation and the Silver-Bell-Ghaly method. The three proposed models are distinguished by their architecture. The first is based on directly measured parameters (DMP-ANN), the second is based on equivalent Reynolds and Prandtl numbers (eq-ANN), and the third on effective Reynolds and Prandtl numbers (eff-ANN). In conclusion, the results demonstrate that the proposed artificial neural network (ANN)-based approaches greatly outperform available methodologies. While Granryd's correlation predicts experimental data within a mean relative error mre = 44% and the S-B-G method produces mre = 42%, DMP-ANN has mre = 7.4% and eff-ANN has mre = 3.9%. Considering that eff-ANN has the lowest mean relative error (one tenth of previously available methodologies) and the broadest range of applicability, it is recommended for future calculations. Implementation is straightforward within a variety of platforms and the matrices with the ANN weights are given in the appendix for efficient programming.

42 ENGINEERING↗

Numerical study on spray collapse process of ECN spray G injector under flash boiling conditions

This work features a numerical study of the spray collapse process that occurs under flash-boiling, gasoline-direct-injection conditions. The Engine Combustion Network's Spray G injector was modeled, and iso-octane, n-hexane, and propane were used as fuels with the goal to investigate fuel property effects. The development of individual jets and jet-to-jet interaction were analyzed to reveal the physical mechanisms of spray collapse. The results agreed qualitatively well with the experimental data of propane available from the literature and the predictions revealed the model's ability to capture the near-nozzle shock structures witnessed in the experiments. Simulations showed that the flow development of flashing sprays was strongly tied with the fuel properties. Specifically, under-expanded jets were not observed with iso-octane due to the fuel's low vapor pressure. In the case of n-hexane, the jets were under-expanded, and a low-pressure core was observed inside the jets due to the flow expansion. With propane, the very strong expansion caused the flow to become transonic and generate a unique shock structure near the nozzle exit. The shock structure revealed the formation of primary shock cells within the jets and secondary shock cells induced by jet-to-jet interaction. Based on the results, the spray collapse under flash boiling conditions was mainly attributed to two effects, i.e., the decrease in pressure at the spray center induced by the low-pressure cores inside and between the jets, and the isolation effect due to the jet-to-jet interaction which contributed to maintain the pressure differential between the spray center and the ambient.

42 ENGINEERING↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

Nucleate boiling performance evaluation of cavities at mesoscale level

Nucleate boiling heat transfer (NBHT) from enhanced structures is an effective way to dissipate high heat flux. Here, a 3D multi-relaxation-time (MRT) phase-change lattice Boltzmann method in conjunction with conjugated heat transfer treatment is proposed and then applied to the study of cavities behaviours for nucleation on roughened surfaces for an entire ebullition cycle without introducing any artificial disturbance. The bubble departure diameter, departure frequency and total boiling heat transfer rate are also explored. We demonstrate that the cavity shapes show significant influence on the features of NBHT. The total heat transfer rate increases with the cavity mouth and cavity base area while decreases with the increase in cavity bottom wall thickness. The cavity with low wetting can enhance the heat transfer and improve the bubble release frequency.

42 ENGINEERING↗

Experimental study of sprays with isooctane, hexane, ethanol and their binary mixtures under different flash boiling intensities

Here, this work investigated the behaviors of single-component and multi-component sprays under different flash boiling intensities. Isooctane, hexane, ethanol, isooctane-hexane, and isooctane-ethanol mixtures were used as test fuels. The pressure ratio of the ambient pressure over saturation pressure (R p ) was used as the indicator of the superheated degree. Macroscopic characteristics of the sprays under 10 different R p (1.1 to 0.14) were investigated using Diffused Backlight Imaging (DBI). Droplet size, which revealed the spray microscopic characteristics, was also investigated using Phase Doppler Anemometry (PDA). The results showed that ambient pressure reduction led to higher flash boiling intensity, significant spray morphology changes, and smaller droplet size, regardless of the fuel type and blend ratios. Spray collapse was observed for all sprays once R p dropped below 0.3. Spray collapse dramatically increased the liquid penetration length, expanded the near-field spray angle, and reduced the far-field angle for sprays with all the fuels. Fuel properties, such as the latent heat of vaporization, had significant impacts on droplet size distributions, thus altering the liquid penetration length and spray angles. Under similar R p , sprays with high ethanol content generally had larger droplet sizes compared with other fuel sprays due to the high latent heat of vaporization. The larger droplets caused the high ethanol content sprays to be more resistant to the plume trajectory change, resulting in a smaller far-field spray angle variations with changing R p . At R p of 0.28, sprays with the similar latent heat of vaporization have similar droplet sizes, and droplet sizes at different radial locations were also similar to each other.

42 ENGINEERING↗

CFD unified approach under Eulerian–Lagrangian framework for methanol and gasoline direct injection sprays in evaporative and flash boiling conditions

Innovative synthetic fuels for advanced propulsion systems, such as methanol and ammonia, and synthetic blended fuels (E00, E10, and E30), known for their high volatility, are often injected directly into combustion chambers. It follows that Eulerian–Lagrangian spray models need to accurately capture the spray collapse as a consequence of flash boiling onset and be capable of proficiently handling the preferential evaporation of multi-component fuels in evaporative scenarios. So, we performed the assessment of an Eulerian–Lagrangian CFD code for simulating methanol and E00 gasoline blend sprays in both early and late injection conditions involving flash boiling conditions and preferential evaporation. The adoption of an effervescent breakup model and of a non-equilibrium phase transition model for the discrete phase allows the adoption of a setup that is almost completely free from specific constant tuning, especially for what concerns the breakup model. We validated the simulations using experimental PLV maps of methanol and E00 sprays issued from the ECN Spray M injector. The results highlight a significantly different morphology of the methanol spray compared to the E00 one under late injection conditions. Under stratified combustion, low-volatile fuels are likely to be ignited first, and the flame propagates toward the high-volatile fuels. In conclusion, the spray collapse was also correctly reproduced, inducing the presence of a low-pressure zone and modifying the spray morphology.

E00↗

A new flow pattern map for flow boiling of R410A in horizontal micro-fin tubes considering the effect of the helix angle

This paper presents an improved flow pattern map for flow boiling in horizontal micro-fin tubes considering the effect of helix angle. The proposed map is modified from the one developed for horizontal smooth tubes by Wojtan et al. (2005) and takes the early transition to annular flow due to micro-fin geometry into account. Visualization of R410A flow boiling is carried out through the transparent smooth and micro-fin tubes with 0°, 10° and 18° helix angle and plotted on the proposed map for comparison. The result shows that the flow pattern map for micro-fin tube with 0° helix angle is generally similar to that for the smooth tube. For the tube with 10° and 18° helix angle, the annular flow occurs at lower vapor quality and lower mass flux. The proposed map shows good agreements when compared with the visualization and reflects the downward shift (to lower mass flux and vapor quality conditions) of the SW-WA transition with the increase of the helix angle. In order to further validate the proposed model, the flow pattern transitions calculated from the equations are also compared with the experimental data of the micro-fin tube in literature. The results show that the modified map increase the prediction accuracy of the flow patterns in the micro-fin tube.

42 ENGINEERING↗

Multi-GPU porting of a phase-change cascaded lattice Boltzmann method for three-dimensional pool boiling simulations

The Lattice Boltzmann method (LBM) has proven effective in simulating phase-change phenomena, such as melting, solidification, evaporation, and boiling. In this work, we develop a highly parallelized multi-GPU implementation of LBM for three-dimensional pool boiling simulations. The code is based on the OpenACC programming model, which enables the code to be deployed efficiently on multi-core CPUs, GPUs, and potentially other accelerators, without the need for architecture-specific rewrites. To support large-scale simulations, the domain is decomposed and distributed across multiple compute nodes using MPI. We demonstrate that the code exhibits excellent scaling properties, with ideal strong-scaling running with up to 256 GPUs on the MareNostrum5 cluster.

97 MATHEMATICS AND COMPUTING↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Evaluation of CFD Methods for Simulation of Two-Phase Boiling Flow Phenomena in a Helical Coil Steam Generator

The U.S. Department of Energy, Office of Nuclear Energy charges participants in the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program with the development of advanced modeling and simulation capabilities that can be used to address design, performance and safety challenges in the development and deployment of advanced reactor technology. The NEAMS has established a high impact problem (HIP) team to demonstrate the applicability of these tools to identification and mitigation of sources of steam generator flow induced vibration (SGFIV). The SGFIV HIP team is working to evaluate vibration sources in an advanced helical coil steam generator using computational fluid dynamics (CFD) simulations of the turbulent primary coolant flow over the outside of the tubes and CFD simulations of the turbulent multiphase boiling secondary coolant flow inside the tubes integrated with high resolution finite element method assessments of the tubes and their associated structural supports. This report summarizes the demonstration of a methodology for the multiphase boiling flow analysis inside the helical coil steam generator tube. A helical coil steam generator configuration has been defined based on the experiments completed by Polytecnico di Milano in the SIET helical coil steam generator tube facility. Simulations of the defined problem have been completed using the Eulerian-Eulerian multi-fluid modeling capabilities of the commercial CFD code STAR-CCM+. Simulations suggest that the two phases will quickly stratify in the slightly inclined pipe of the helical coil steam generator. These results have been successfully benchmarked against both empirical correlations for pressure drop and simulations using an alternate CFD methodology, the dispersed phase mixture modeling capabilities of the open source CFD code Nek5000.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗