Some characteristic features of the construction of the amplifying channel for working with semiconductor detectors in the charged particle energy spectrometer

A transistorized spectrometric amplifier with a shaper is reported that selects the shape of the frequency characteristic of the amplifying channel for which the primary frequency spectrum of the signal will pass, but where the noise spectrum is limited to the maximum. A procedure is presented for selecting the shaping circuits and their inclusion principles.

Kuzyuta, E. I.↗

Integrated-circuit balanced parametric amplifier

Amplifier, fabricated on single dielectric substrate, has pair of Schottky barrier varactor diodes mounted on single semiconductor chip. Circuit includes microstrip transmission line and slot line section to conduct signals. Main features of amplifier are reduced noise output and low production cost.

Dickens, L. E.↗

Solid state radiographic image amplifiers, part C

The contrast sensitivity of the radiographic amplifiers, both the storage type and nonstorage type, their absolute sensitivity, and the reproducibility of fabrication were investigated. The required 2-2T quality level was reached with the radiographic storage screen. The sensitivity threshold was 100 to 200 mR with 45 to 100 kV filtered X-rays. The quality level of the radiographic amplifier screen (without storage) was 4-4T; for a 6 mm (0.25 in.) thick aluminum specimen, a 1 mm (0.040 in.) diameter hole in a 0.25 mm (0.010 in.) thick penetrameter was detected. Its sensitivity threshold was 2 to 6 mR/min. The developed radiographic screens are applicable for uses in nondestructive testing.

Szepesi, Z.↗

Design and analysis of optically pumped submillimeter waveguide maser amplifiers and oscillators

The design and experimental measurements are described of an optically pumped far-infrared (FIR) waveguide maser; preliminary measurements on a FIR waveguide amplifier are presented. The FIR maser was found to operate satisfactorily in a chopped CW mode using either methanol (CH3OH) or acetonitrile (CH3CN) as the active molecule. Two other gases, difluoroethane and difluoroethylene, produced an unstable output with high threshold and low output power when operated in the chopped CW mode. Experimental measurements include FIR output versus cavity length, output beam pattern, output power versus pressure, and input power. The FIR output was the input to an amplifier which was constructed similar to the oscillator. An increase of 10% in output power was noted on the 118.8 microns line of methanol.

Galantowicz, T. A.↗

Hybrid thin-film amplifier

Miniature amplifier for bioelectronic instrumentation consumes only about 100 mW and has frequency response flat to within 0.5 dB from 0.14 to 450 Hz. Device consists of five thin film substrates, which contain eight operational amplifiers and seven field-effect transistor dice.

Cleveland, G.↗

Deflection amplifier for image dissectors

Balanced symmetrical y-axis amplifier uses zener-diode level shifting to interface operational amplifiers to high voltage bipolar output stages. Nominal voltage transfer characteristic is 40 differential output volts per input volt; bandwidth, between -3-dB points, is approximately 8 kHz; loop gain is nominally 89 dB with closed loop gain of 26 dB.

Salomon, P. M.↗

Computer-oriented synthesis of wide-band non-uniform negative resistance amplifiers

This paper presents a synthesis procedure which provides design values for broad-band amplifiers using non-uniform negative resistance devices. Employing a weighted least squares optimization scheme, the technique, based on an extension of procedures for uniform negative resistance devices, is capable of providing designs for a variety of matching network topologies. It also provides, for the first time, quantitative results for predicting the effects of parameter element variations on overall amplifier performance. The technique is also unique in that it employs exact partial derivatives for optimization and sensitivity computation. In comparison with conventional procedures, significantly improved broad-band designs are shown to result.

Branner, G. R.↗

Amplifying ribbon extensometer for measuring film and fabric strain

Variations of a low-cost amplifying linear threshold extensometer are presented in detail for high or low strain applications. Derivations of scale relationships and extraction forces are included with experimental correlations and analyses given on performance, attachment problems, gain selection, gage and base material compatibility, and zero setting techniques. Flight applications of unamplified gages on parawing deployment tests are noted. The amplified gages perform accurately in laboratory tests and further experience is needed on performance under dynamic environments.

Alley, V. L., Jr.↗

An optically pumped submillimeter wavelength regenerative amplifier

An optically pumped regenerative submillimeter laser amplifier is described. The amplifier uses a waveguide cavity resonator, and a Fabry-Perot interferometer composed of two dielectric-coated mirrors serves as input and output port for the submillimeter signal. Use of two mirrors enabled obtaining variations of up to 6:1 in transmission by varying the mirror spacing. When the 373-micron transition in CH3CN is excited in the oscillator by the CO2 laser pump beam, the received signal with amplification is about nine times the unamplified signal.

Galantowicz, T. A.↗

A 24 channel acoustic/vibration test power amplifier

In the present paper, the advantages and drawbacks of a multichannel amplifier operating in a vibration or acoustic facility are discussed. The configuration of the facility and the multichannel amplifier proposed is a compromise based on the particular requirements and anticipated work load in a specific case under consideration.

Barlett, F. R.↗

A 4-W 56-dB gain microstrip amplifier at 15 GHz utilizing GaAs FET's and IMPATT diodes

Performance results and design considerations are presented for an all solid-state Ku-band power amplifier which is feasible for use in PM communication systems for airborne or spacecraft transmitter applications. A six-stage GaAs FET preamplifier and a driver and balanced power amplifier utilizing GaAs IMPATT diodes operating in the injection locked oscillator mode are discussed. For high power and efficiency Schottky-Read IMPATT's with low-high-low doping profiles are employed. For improved reliability the IMPATT's incorporate a TiW barrier metallization to retard degradation of the IMPATT's. Results of accelerated life testing of the IMPATT devices are also presented.

Sokolov, V.↗

The 31.4 GHz parametric amplifier

A degenerate parametric amplifier for 31.4 GHz was studied, designed and constructed. Good mechanical stability and a wide bandwidth of about 800 MHz were achieved using Schottky barrier varactors mounted in specially designed Sharpless wafers and a fixed tuned amplifier mount.

Edrich, J.↗

The interhalogens IF and ICI as visible oscillators or amplifiers

The kinetic and spectroscopic properties of the interhalogens are reviewed, with emphasis on the iodine-monochloride (ICl) and iodine-monofluoride (IF) systems; the latter having produced 140 kW, 30 nsec FWHM pulses at 491 and 485 nm and may be scaled to the tens of millijoules per pulse level. Gain in excess of 1.0%/cm was observed across the entire IF blue-green band, demonstrating potentially wide tunability. Although ICl has not yet lased, its peak small-signal gain of 1.3%/cm and negligible background absorption in discharge plasmas make it an attractive candidate for a violet amplifier. The formation kinetics of IF- and ICl-excimer lasers in electron beam or discharge-produced plasmas, and the potential and limitations of these molecules as visible lasers or amplifiers are also discussed.

Eden, J. G.↗

Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients.

Eichinger, R. A.↗

Computer modeling of multiple-channel input signals and intermodulation losses caused by nonlinear traveling wave tube amplifiers

The multiple channel input signal to a soft limiter amplifier as a traveling wave tube is represented as a finite, linear sum of Gaussian functions in the frequency domain. Linear regression is used to fit the channel shapes to a least squares residual error. Distortions in output signal, namely intermodulation products, are produced by the nonlinear gain characteristic of the amplifier and constitute the principal noise analyzed in this study. The signal to noise ratios are calculated for various input powers from saturation to 10 dB below saturation for two specific distributions of channels. A criterion for the truncation of the series expansion of the nonlinear transfer characteristic is given. It is found that he signal to noise ratios are very sensitive to the coefficients used in this expansion. Improper or incorrect truncation of the series leads to ambiguous results in the signal to noise ratios.

Stankiewicz, N.↗

A wavelength scannable XeCl oscillator-ring amplifier laser system

A holographic grating at grazing angle of incidence was used to achieve tunable, narrow bandwidth (0.005 nm) operation of a XeCl oscillator for injection locking of a ring amplifier. The amplifier's narrow bandwidth output energy was constant and equal to the untuned, broadband output (approximately 15 mJ) in regions where injection locking was achieved. Scanning was provided by use of a stepping motor-driven differential micrometer on the tuning mirror. This system was used to produce a laser excitation spectrum of hydroxyl radicals (OH) in a flame.

Pacala, T. J.↗

A remote millivolt multiplexer and amplifier module for wind tunnel data acquisition

A 30-channel remotely located multiplexer and amplifier module is developed for the measurement of wind tunnel models, which substantially reduces the amount of wiring necessary and thus provides higher accuracy. The module provides for a wide variety of transducer voltage outputs to be multiplexed and amplified within the model, and all signals are able to exit the module on two wires. The module is self-calibrating, and when coupled with the electronically scanned pressure instrumentation widely used in wind tunnels, it allows the modular wind tunnel models to be fabricated and checked before installation into the wind tunnel.

Juanarena, D. B.↗

Band-Pass Amplifier Without Discrete Reactance Elements

Inherent or "natural" device capacitance exploited. Band-Pass Circuit has input impedance of equivalent circuit at frequencies much greater than operational-amplifier rolloff frequency. Apparent inductance and capacitance arise from combined effects of feedback and reactive component of amplifier gain in frequency range.

Kleinberg, L.↗