Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Results of the Quasi-Steady Acceleration Environment from the STS-62 Missions

One of the clear benefits of conducting scientific research in space is to take advantage of the reduced acceleration environment. Many accelerometer packages have proven to accurately measure the acceleration environment at frequency levels above one Hz. However, for particular classes of experiments the quality of science returns is a direct function of the extremely low frequency (less than 0.01 Hz), quasi-steady acceleration environment. One class particularly interested in this acceleration regime is the group of crystal growth experimenters. These scientists are primarily interested in knowing the resultant quasi-steady acceleration vector at their respective crystal growth locations. The objective of many of these scientists is to minimize the amount of convective flow acting in a direction perpendicular to the growth axis of the crystal. Convective flow within the crystal can be induced by the direction and magnitude of the quasi-steady acceleration vector. Convective flows acting perpendicular to the growth axis of the crystal can cause nonuniformity within the crystal, thus reducing the quality of the results. The Orbital Acceleration Research Experiment (OARE), an accelerometer package hardmounted to the bottom of the payload bay of the orbiter Columbia (OV-102), has the capability of monitoring and recording the quasi-steady acceleration environment. This paper will describe the components that make up the on-orbit quasi-steady acceleration environment, detail how results from the OARE device were achieved, and compare modelled acceleration results with actual on-orbit OARE results from the STS-62 and STS-65 flights. A summary of the results will be provided along with possible recommendations of how to combine modelled and realtime quasi-steady accelerometer data for future Shuttle flights.

Matisak, Brian↗

Flight Investigation of a Normal-Acceleration Automatic Longitudinal Control System in a Fighter Airplane

A flight investigation was made to obtain experimental information on the handling qualities of a normal-acceleration type of automatic longitudinal control system. The control system was installed in a subsonic fighter-type airplane. In hands-off (stick-free) flight the normal-acceleration control system attempted to regulate the normal acceleration to a constant value which is dependent on the automatic-control-system trim setting. In maneuvering flight a given pilot's stick deflection produced a proportional change in normal acceleration, the change in acceleration being independent of flight condition. A small side-located controller stick was used by the pilot to introduce signals into the automatic control system. In the flight program emphasis was placed on the acceleration-limiting capabilities of the control system. The handling qualities were investigated in maneuvers such as slow and rapid pull-ups and turns and also in flight operations such as cruising, stalls, landings, aerobatics, and air-to-air tracking. Good acceleration limiting was obtained with the normal-acceleration control system by limiting the magnitude of the input signal that the pilot could introduce into the control system. The same values of control-system gain settings could be used from an acceleration-limiting stand-point at both 10,000 and 30,000 feet for the complete speed range of the airplane. The response characteristics of the airplane-control system combination were also satisfactory at both high and low altitude with these same values of control-system gain setting. In the pilot's opinion, the normal-acceleration control system provided good stability and control characteristics in flight operations such as cruising, stalls, landings, aerobatics, and air-to-air tracking.

Sjoberg, S. A.↗

Principal Investigator Microgravity Services Role in ISS Acceleration Data Distribution

Measurement of the microgravity acceleration environment on the International Space Station will be accomplished by two accelerometer systems. The Microgravity Acceleration Measurement System will record the quasi-steady microgravity environment, including the influences of aerodynamic drag, vehicle rotation, and venting effects. Measurement of the vibratory/transient regime comprised of vehicle, crew, and equipment disturbances will be accomplished by the Space Acceleration Measurement System-II. Due to the dynamic nature of the microgravity environment and its potential to influence sensitive experiments, Principal Investigators require distribution of microgravity acceleration in a timely and straightforward fashion. In addition to this timely distribution of the data, long term access to International Space Station microgravity environment acceleration data is required. The NASA Glenn Research Center's Principal Investigator Microgravity Services project will provide the means for real-time and post experiment distribution of microgravity acceleration data to microgravity science Principal Investigators. Real-time distribution of microgravity environment acceleration data will be accomplished via the World Wide Web. Data packets from the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System-II will be routed from onboard the International Space Station to the NASA Glenn Research Center's Telescience Support Center. Principal Investigator Microgravity Services' ground support equipment located at the Telescience Support Center will be capable of generating a standard suite of acceleration data displays, including various time domain and frequency domain options. These data displays will be updated in real-time and will periodically update images available via the Principal Investigator Microgravity Services web page.

McPherson, Kevin↗

Dusty-Plasma Particle Accelerator

A dusty-plasma apparatus is being investigated as means of accelerating nanometer- and micrometer-sized particles. Applications for the dusty-plasma particle accelerators fall into two classes: Simulation of a variety of rapidly moving dust particles and micrometeoroids in outer-space environments that include micrometeoroid streams, comet tails, planetary rings, and nebulae and Deposition or implantation of nanoparticles on substrates for diverse industrial purposes that could include hardening, increasing thermal insulation, altering optical properties, and/or increasing permittivities of substrate materials. Relative to prior apparatuses used for similar applications, dusty-plasma particle accelerators offer such potential advantages as smaller size, lower cost, less complexity, and increased particle flux densities. A dusty-plasma particle accelerator exploits the fact that an isolated particle immersed in plasma acquires a net electric charge that depends on the relative mobilities of electrons and ions. Typically, a particle that is immersed in a low-temperature, partially ionized gas, wherein the average kinetic energy of electrons exceeds that of ions, causes the particle to become negatively charged. The particle can then be accelerated by applying an appropriate electric field. A dusty-plasma particle accelerator (see figure) includes a plasma source such as a radio-frequency induction discharge apparatus containing (1) a shallow cup with a biasable electrode to hold the particles to be accelerated and (2) a holder for the substrate on which the particles are to impinge. Depending on the specific design, a pair of electrostatic-acceleration grids between the substrate and discharge plasma can be used to both collimate and further accelerate particles exiting the particle holder. Once exposed to the discharge plasma, the particles in the cup quickly acquire a negative charge. Application of a negative voltage pulse to the biasable electrode results in the initiation of a low-current, high-voltage cathode spot. Plasma pressure associated with the cathode spot as well as the large voltage drop at the cathode spot accelerates the charged particles toward the substrate. The ultimate kinetic energy attained by particles exiting the particle holder depends in part on the magnitude of the cathode spot sheath potential difference, which is proportional to the magnitude of the voltage pulse, and the on the electric charge on the dust. The magnitude of the voltage pulse can be controlled directly, whereas the particle s electric charge can be controlled indirectly by controlling the operating parameters of the plasma apparatus.

Foster, John E.↗

Illinois Accelerator Research Center

The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi's state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 ft2 heavy assembly building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Connected to the HAB is a 47,000 ft Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building, which contains the Accelerator Physics Center, and nearby Accelerator and Technical divisions provide IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. Finally, at IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security.

43 PARTICLE ACCELERATORS↗

Calculation and Analysis of Electrophysical Processes in a High-Power Plasma Accelerator with an Intrinsic Magnetic Field

We have considered basic theoretical models describing various aspects of the formation and acceleration of plasma in pulsed accelerators. The discharge current, magnetic field, and plasma bunch velocity have been determined experimentally at different initial gas pressures in the accelerator chamber. We have considered the correspondence of some theoretical models of plasma acceleration to experimental data obtained in a KPU-30 coaxial accelerator. It is shown that the formation of the plasma in the coaxial accelerator depends on the plasma density, and acceleration processes at densities higher and lower than a certain transient density value on the order of 10{sup 11}–10{sup 12} cm{sup –3} are different. At a density higher than this critical value, the plasma is accelerated by a magnetic force. At the same time, at a low plasma density, plasma can be accelerated by an internal electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Accelerator Technology (Final Report)

Superconducting radio-frequency (SRF) acceleration, together with high precision RF field control and high precision beam instrumentation and control, is a key technology for future next generation accelerators. In the past 10 years, significant progress on these technologies has been made jointly at KEK and US laboratories. The research progress summarized here is Cornell University’s contribution to a continued US-Japan collaborative accelerator research effort. The combined objectives of this collaboration were to solve critical technical issues related to SRF acceleration technology, related to low emittance beam generation, and related to reducing the vertical beam size of the ATF2 final focus beam line. These joint efforts significantly advance current accelerator technologies. The specific objective of the Cornell University part of this collaboration was to develop, in close connection with KEK and FNAL, new SRF cavity Nb3Sn thin-film coating technologies for transformational cavity performance. Cornell is a world leader in the synthesis of Nb3Sn for SRF application, and has produced the first-ever next-generation non-niobium (i.e., Nb 3 Sn) prototype SRF accelerator cavities with cryogenic efficiency exceeding that of traditional niobium cavities. These next-generation Nb 3 Sn SRF cavities strongly reduce AC power consumption of SRF based accelerators, and also enable using greatly simplified cryogenic cooling infrastructure, thereby making SRF technology available to a much wider range of accelerator applications. During this project, Cornell has designed and started fabrication of a new Nb 3 Sn coating setup, which will be large enough to coat full-scale (i.e., multi-cell) SRF accelerator cavities. In addition, Cornell University has participated in other collaborative activities at KEK and partner US laboratories.

43 PARTICLE ACCELERATORS↗

Design Philosophy for Accelerator Control Rooms

This report describes the foundational human factors principles needed to design user interfaces for accelerator control rooms. These principles are presented as recommendations for accelerator control system interface design and are illustrated with examples drawn from accelerator operations at Fermi National Accelerator Laboratory (Fermilab). These high-level principles are intended to serve as design objectives that apply generally across all control system interfaces developed for the accelerator complex. This design philosophy document is a high-level roadmap to approach the general interface design for the accelerator complex. This philosophy applies state-of-the-art human factors principles and evidence-based design standards to an accelerator environment, which will transform the next era of accelerator interfaces as outlined by the Accelerator Controls Operations Research Network (ACORN) Project. Further work will include mapping the general design principles included in this report to more specific guidance in the form of a user interface style guide.

43 PARTICLE ACCELERATORS↗

Transversely pumped laser driven particle accelerator

We present a novel acceleration scheme capable of accelerating electrons and ions in an underdense plasma. Transversely Pumped Acceleration (TPA) uses multiple arrays of counter-propagating laser beamlets that focus onto a central acceleration axis. Tuning the injection timing and the spacing between the adjacent beamlets allows for precise control over the position and velocity of the intersection point of the counter-propagating beam arrays. This results in an accelerating structure that propagates orthogonal to the direction of laser propagation. We present the theory that sets the injection timing of the incoming pulses to accelerate electrons and ions with a tunable phase velocity plasma wave. Simulation results are also presented which demonstrate 1.12 GeV proton beams accelerated in 3.6 mm of plasma and electron acceleration gradients on the order of 1 TeV/m in a scheme that circumvents dephasing. This work has potential applications as a compact accelerator for medical physics and high energy physics colliders.

Laser-produced plasmas↗

Non-thermal electron acceleration from magnetically driven reconnection in a laboratory plasma

Magnetic reconnection rapidly converts magnetic energy into some combination of plasma flow energy, thermal energy and non-thermal energetic particles. Various reconnection acceleration mechanisms have been theoretically proposed and numerically studied in different collisionless and low-β environments, where β refers to the plasma-to-magnetic pressure ratio. These mechanisms include Fermi acceleration, betatron acceleration, parallel electric field acceleration along magnetic fields and direct acceleration by the reconnection electric field. However, none of them have been experimentally confirmed, as the direct observation of non-thermal particle acceleration in laboratory experiments has been difficult due to short Debye lengths for in situ measurements and short mean free paths for ex situ measurements. Here we report the direct measurement of accelerated non-thermal electrons from magnetically driven reconnection at low β in experiments using a laser-powered capacitor coil platform. We use kilojoule lasers to drive parallel currents to reconnect megagauss-level magnetic fields in a quasi-axisymmetric geometry. The angular dependence of the measured electron energy spectrum and the resulting accelerated energies, supported by particle-in-cell simulations, indicate that the mechanism of direct electric field acceleration by the out-of-plane reconnection electric field is at work. Scaled energies using this mechanism show direct relevance to astrophysical observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy recovery proton linear accelerator

High-power proton linear accelerators have important applications in both scientific research and industry. However, the operation of such accelerators with megawatt-level beam power is expensive and limits the broad availability of these facilities. In this Letter, we propose a novel energy recovery proton linear accelerator in which the final GeV-level proton beam is reinjected into the linear accelerator from the accelerator exit and is decelerated in the same accelerator down to about 2 MeV, close to the initial beam energy. This substantially reduces the power consumption of the proton linear accelerator and also avoids the need for a high-power beam dump. We demonstrate this concept through self-consistent simulations and show that the beam-beam effect between the forward-accelerating beam and the backward-decelerating beam would not be a limiting factor for the proposed concept. A potential application of this concept to an electron-ion collider based on energy recovery electron and ion accelerators is discussed.

Energy recovery linacs↗

Advanced Control Methods for Particle Accelerators (ACM4PA) 2019

Los Alamos is currently developing novel particle accelerator controls and diagnostics algorithms to enable higher quality beams with lower beam losses than is currently possible. The purpose of this workshop was to consider tuning and optimization challenges of a wide range of particle accelerators including linear proton accelerators such as the Los Alamos Neutron Science Center (LANSCE), rings such as the Advanced Photon Source (APS) synchrotron, free electron lasers (FEL) such as the Linac Coherent Light Source (LCLS) and LCLS-II, the European X-ray Free Electron Laser (EuXFEL), the Swiss FEL, and the planned MaRIE FEL, and plasma wake- eld accelerators such as FACET, FACET-II, and AWAKE at CERN. One major challenge is an the ability to quickly create very high quality, extremely intense, custom current and energy pro le beams while working with limited real time non-invasive diagnostics and utilizing time-varying uncertain initial beam distributions and accelerator components. Currently, a few individual accelerator labs have been developing and applying their own diagnostics tools and custom control and ML algorithms for au- tomated machine tuning and optimization. The goal of this workshop was to bring together a group of accelerator physicists and accelerator related control and ML experts in order to de ne which controls and diagnostics would be most useful for existing and future accelerators and to create a plan for developing a new family of algorithms that can be shared and maintained by the community.

43 PARTICLE ACCELERATORS↗

Particle Acceleration in Kinetic Simulations of Nonrelativistic Magnetic Reconnection with Different Ion–Electron Mass Ratios

By means of fully kinetic particle-in-cell simulations, we study whether the proton-to-electron mass ratio m i /m e influences the energy spectrum and underlying acceleration mechanism during magnetic reconnection. While kinetic simulations are critical to studying particle acceleration during magnetic reconnection, a reduced m i /m e is often used to alleviate the demanding computing resources, which leads to artificial scale separation between electron and proton scales. Recent kinetic simulations with high mass ratios have indicated new regimes of reconnection, as electron pressure anisotropy develops in the exhaust region and supports extended current layers. Here, we study whether different m i /m e changes the particle acceleration processes by performing a series of simulations with different mass ratio (m i /m e = 25–400) and guide field strength in a low-β plasma. We find that mass ratio does not strongly influence reconnection rate, magnetic energy conversion, ion internal energy gain, plasma energization processes, ion energy spectra, and the acceleration mechanisms for high-energy ions. Simulations with different mass ratios are different in electron acceleration processes, including electron internal energy gain, electron energy spectrum, and the acceleration efficiencies for high-energy electrons. We find that high-energy electron acceleration becomes less efficient when the mass ratio gets larger because the Fermi -like mechanism associated with particle curvature drift becomes less efficient. These results indicate that when particle curvature drift dominates high-energy particle acceleration, the further the particle kinetic scales are from the magnetic field curvature scales (~d i ), the weaker the acceleration will be.

79 ASTRONOMY AND ASTROPHYSICS↗

Whitepaper submitted to Snowmass21: Advanced accelerator linear collider demonstration facility at intermediate energy

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1--100~GV/m, leading to compact acceleration structures. Over the last 10-15 years significant progress has been achieved in accelerating electron beams by ANAs. For example, the demonstration of several-GeV electron beams from laser-powered capillary discharge waveguides, as well as the proof-of-principle coupling of two accelerating structures powered by different laser pulses, has increased interest in ANAs as a viable technology to be considered for a compact, TeV-class, lepton linear collider. However, intermediate facilities are required to test the technology and demonstrate key subsystems. A 20-100 GeV center-of-mass energy ANA-based lepton collider can be a possible candidate for an intermediate facility. Apart from being a test beam facility for accelerator and detector studies, this collider will provide opportunities to study muon and proton beam acceleration, investigate charged particle interactions with extreme electromagnetic fields (relevant for beam delivery system designs and to study the physics at the interaction point), as well as precision Quantum Chromodynamics and Beyond the Standard Model physics measurements. Possible applications of this collider include the studies of $\gamma\gamma$ and $e$-ion collider designs.

43 PARTICLE ACCELERATORS↗

Cyclotron resonance accelerators for industrial applications

Here, this paper describes novel configurations for cyclotron resonance acceleration of electrons and ions that have several attractive features including: a compact robust room-temperature single-cell RF cavity as the accelerator structure; and continuous high current accelerated un-bunched beam output with self-scanning, obviating need for a separate beam scanner. An electron accelerator version, the electron Cyclotron Resonance Accelerator (eCRA), is under development to be an efficient source for high power electron and x-ray beams for medical, research, sterilization, and National Security applications, so as to replace radioactive materials. An ion accelerator version, the ion Cyclotron Auto-Resonance Accelerator (iCARA) is described here, suggesting its potential to produce, as an example, a high-current multi-MeV beam of deuterons which could be highly competitive with that produced either with linacs or cyclotrons. Such a deuteron beam could produce a high flux of fast neutrons via deuteron stripping, for applications including the transmutation of used nuclear fuel, material studies relevant for a fusion reactor inner wall, tritium breeding and medical isotope production. For the high-current, high efficiency simulated performance for eCRA and iCARA as described in this paper, the particle beams produced may not exhibit the low emittance values that are important for most discovery research. Rather, the beams could be useful for industrial applications where higher emittance and some energy spread can be tolerated, in favor of high beam power.

43 PARTICLE ACCELERATORS↗

Analysis of dynamics, stability, and flow fields' structure of an accelerated hydrodynamic discontinuity with interfacial mass flux by a general matrix method

We develop a general matrix method to analyze from a far field the dynamics of an accelerated interface between incompressible ideal fluids of different densities with interfacial mass flux and with negligible density variations and stratification. We rigorously solve the linearized boundary value problem for the dynamics conserving mass, momentum, and energy in the bulk and at the interface. We find a new hydrodynamic instability that develops only when the acceleration magnitude exceeds a threshold. This critical threshold value depends on the magnitudes of the steady velocities of the fluids, the ratio of their densities, and the wavelength of the initial perturbation. The flow has potential velocity fields in the fluid bulk and is shear-free at the interface. The interface stability is set by the interplay of inertia and gravity. For weak acceleration, inertial effects dominate, and the flow fields experience stable oscillations. For strong acceleration, gravity effects dominate, and the dynamics is unstable. For strong accelerations, this new hydrodynamic instability grows faster than accelerated Landau-Darrieus and Rayleigh-Taylor instabilities. For given values of the fluids' densities and their steady bulk velocities, and for a given magnitude of acceleration, we find the critical and maximum values of the initial perturbation wavelength at which this new instability can be stabilized and at which its growth is the fastest. The quantitative, qualitative, and formal properties of the accelerated conservative dynamics depart from those of accelerated Landau-Darrieus and Rayleigh-Taylor dynamics. New diagnostic benchmarks are identified for experiments and simulations of unstable interfaces.

Flow dynamics↗

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Microgravity acceleration measurement and environment characterization science (17-IML-1)

The Space Acceleration Measurement System (SAMS) is a general purpose instrumentation system designed to measure the accelerations onboard the Shuttle Orbiter and Shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigation into the microgravity environment of the vehicle. Acceleration measurements can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The prime objective for SAMS on the International Microgravity Lab (IML-1) mission will be to measure the accelerations experienced by the Fluid Experiment System (FES). The SAMS acceleration measurements for FES will be complemented by low level, low frequency acceleration measurements made by the Orbital Acceleration Research Experiment (OARE) installed on the shuttle. Secondary objectives for SAMS will be to measure accelerations at several specific locations to enable the acceleration transfer function of the Spacelab module to be analyzed. This analysis effort will be in conjunction with similar measurements analyses on other Spacelab missions.

Source record↗