At least 253 records · Page 14

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Investigation of Spiral Bevel Gear Condition Indicator Validation via AC-29-2C Using Fielded Rotorcraft HUMS Data

This report presents the analysis of gear condition indicator data collected on a helicopter when damage occurred in spiral bevel gears. The purpose of the data analysis was to use existing in-service helicopter HUMS flight data from faulted spiral bevel gears as a Case Study, to better understand the differences between HUMS data response in a helicopter and a component test rig, the NASA Glenn Spiral Bevel Gear Fatigue Rig. The reason spiral bevel gear sets were chosen to demonstrate differences in response between both systems was the availability of the helicopter data and the availability of a test rig that was capable of testing spiral bevel gear sets to failure. The objective of the analysis presented in this paper was to re-process helicopter HUMS data with the same analysis techniques applied to the spiral bevel rig test data. The damage modes experienced in the field were mapped to the failure modes created in the test rig. A total of forty helicopters were evaluated. Twenty helicopters, or tails, experienced damage to the spiral bevel gears in the nose gearbox. Vibration based gear condition indicators data was available before and after replacement. The other twenty tails had no known anomalies in the nose gearbox within the time frame of the datasets. These twenty tails were considered the baseline dataset. The HUMS gear condition indicators evaluated included gear condition indicators (CI) Figure of Merit 4 (FM4), Root Mean Square (RMS) or Diagnostic Algorithm 1 (DA1) and +/- 3 Sideband Index (SI3). Three additional condition indicators, not currently calculated on-board, were calculated from the archived data. These three indicators were +/- 1 Sideband Index (SI1), the DA1 of the difference signal (DiffDA1) and the peak-to-peak of the difference signal (DP2P). Results found the CI DP2P, not currently available in the on-board HUMS, performed the best, responding to varying levels of damage on thirteen of the fourteen helicopters evaluated. Two additional CIs also not in the on-board system, DiffDA1and SI1, also performed well responding to twelve and ten of the fourteen helicopters evaluated respectively. Of the three CIs currently available in the MSPU, DA1, FM4 and SI3, SI3, responded to eight, DA1 responded to six and FM4 responded to four of the fourteen helicopters evaluated. FM4, the poorest performing CI, was not as responsive to damage as the other five CIs. Conversely, when compared to the other two, it was the only CI that responded to damage on two helicopters. CI response could not be correlated to specific failure modes due to limited pictures and subjective descriptions found within the TDA. Flight regime did affect CI response to some gear faults. Due to the range of operating conditions for each regime, more studies are required to determine their sensitivity to regimes.

rotorcraft↗

Finding Atmospheric Composition (AC) Metadata

The Atmospheric Composition Portal (ACP) is an aggregator and curator of information related to remotely sensed atmospheric composition data and analysis. It uses existing tools and technologies and, where needed, enhances those capabilities to provide interoperable access, tools, and contextual guidance for scientists and value-adding organizations using remotely sensed atmospheric composition data. The initial focus is on Essential Climate Variables identified by the Global Climate Observing System CH4, CO, CO2, NO2, O3, SO2 and aerosols. This poster addresses our efforts in building the ACP Data Table, an interface to help discover and understand remotely sensed data that are related to atmospheric composition science and applications. We harvested GCMD, CWIC, GEOSS metadata catalogs using machine to machine technologies - OpenSearch, Web Services. We also manually investigated the plethora of CEOS data providers portals and other catalogs where that data might be aggregated. This poster is our experience of the excellence, variety, and challenges we encountered.Conclusions:1.The significant benefits that the major catalogs provide are their machine to machine tools like OpenSearch and Web Services rather than any GUI usability improvements due to the large amount of data in their catalog.2.There is a trend at the large catalogs towards simulating small data provider portals through advanced services. 3.Populating metadata catalogs using ISO19115 is too complex for users to do in a consistent way, difficult to parse visually or with XML libraries, and too complex for Java XML binders like CASTOR.4.The ability to search for Ids first and then for data (GCMD and ECHO) is better for machine to machine operations rather than the timeouts experienced when returning the entire metadata entry at once. 5.Metadata harvest and export activities between the major catalogs has led to a significant amount of duplication. (This is currently being addressed) 6.Most (if not all) Earth science atmospheric composition data providers store a reference to their data at GCMD.

metadata search↗

Investigation of Spiral Bevel Gear Condition Indicator Validation via AC-29-2C Combining Test Rig Damage Progression Data with Fielded Rotorcraft Data

This is the final of three reports published on the results of this project. In the first report, results were presented on nineteen tests performed in the NASA Glenn Spiral Bevel Gear Fatigue Test Rig on spiral bevel gear sets designed to simulate helicopter fielded failures. In the second report, fielded helicopter HUMS data from forty helicopters were processed with the same techniques that were applied to spiral bevel rig test data. Twenty of the forty helicopters experienced damage to the spiral bevel gears, while the other twenty helicopters had no known anomalies within the time frame of the datasets. In this report, results from the rig and helicopter data analysis will be compared for differences and similarities in condition indicator (CI) response. Observations and findings using sub-scale rig failure progression tests to validate helicopter gear condition indicators will be presented. In the helicopter, gear health monitoring data was measured when damage occurred and after the gear sets were replaced at two helicopter regimes. For the helicopters or tails, data was taken in the flat pitch ground 101 rotor speed (FPG101) regime. For nine tails, data was also taken at 120 knots true airspeed (120KTA) regime. In the test rig, gear sets were tested until damage initiated and progressed while gear health monitoring data and operational parameters were measured and tooth damage progression documented. For the rig tests, the gear speed was maintained at 3500RPM, a one hour run-in was performed at 4000 in-lb gear torque, than the torque was increased to 8000 in-lbs. The HUMS gear condition indicator data evaluated included Figure of Merit 4 (FM4), Root Mean Square (RMS) or Diagnostic Algorithm 1(DA1), + 3 Sideband Index (SI3) and + 1 Sideband Index (SI1). These were selected based on their sensitivity in detecting contact fatigue damage modes from analytical, experimental and historical helicopter data. For this report, the helicopter dataset was reduced to fourteen tails and the test rig data set was reduced to eight tested gear sets. The damage modes compared were separated into three cases. For case one, both the gear and pinion showed signs of contact fatigue or scuffing damage. For case two, only the pinion showed signs of contact fatigue damage or scuffing. Case three was limited to the gear tests when scuffing occurred immediately after the gear run-in. Results of this investigation highlighted the importance of understanding the complete monitored systems, for both the helicopter and test rig, before interpreting health monitoring data. Further work is required to better define these two systems that include better state awareness of the fielded systems, new sensing technologies, new experimental methods or models that quantify the effect of system design on CI response and new methods for setting thresholds that take into consideration the variance of each system.

spiral bevel gears↗

Multilayered Functional Insulation System (MFIS) for AC Power Transmission in High Voltage Hybrid Electrical Propulsion

High voltage hybrid electric propulsion systems are now pushing new technology development efforts for air transportation. A key challenge in hybrid electric aircraft is safe high voltage distribution and transmission of megawatts of power (>20 MW). For the past two years, a multidisciplinary materials research team at NASA Glenn Research Center has investigated the feasibility of distributing high voltage power on future hybrid electric aircraft. This presentation describes the team's approach to addressing this challenge, significant technical findings, and next steps in GRC's materials research effort for MW power distribution on aircraft.

high voltage power transmission↗

An Overview of the Aerosol and Clouds-Convection-Precipitation Study (A-CCP) and its Relationship to the Geostationary AC-VC

The 2017 Decadal Survey (DS) highlighted Earth System Science themes, science and application questions, and several high priority objectives that have led to the inclusion of Aerosols (A) and Clouds-Convection-Precipitation (CCP) as Designated Observables (DOs) The aerosol-related science questions outlined by the DS focus on two major themes: 1) Climate Variability and Change and 2) Weather and Air Quality. The Aerosol mission observables targeted to address these major objectives may potentially contribute to three additional themes: 3) Marine and Terrestrial Ecosystems, 4) Global Hydrological Cycle, and 5) Earth Surface and Interior; this study will examine these linkages.In response to NASA's Designated Observables Guidance for Multi-Center Study Plans released on June 1, 2018, GSFC, LaRC, JPL, MSFC, GRC and ARC submitted Study Plan to the NASA Earth Science Division for the Aerosol (A) and Cloud, Convection, and Precipitation (CCP) Pre-formulation Study (A-CCP). The DS recognized the science merit in combining the A and CCP DOs for both enhancing the ability to address a number of Most Important (MI) objectives defined by the disciplinary panels and also to provide an expanded capability to address additional objectives beyond those addressed by individual DOs. The DS also identified Integrating Themes that can also be addressed through combinations of observables including potential combinations of DOs and the PoR. The combined A+CCP portion of this study will demonstrate how the combination of A and CCP observables will enhance the objectives of A and CCP individually, while providing the ability to expand the DS objectives addressed, and will closely connect to the A and CCP studies being performed in parallel. A critical element of the A-CCP observing strategy is to make extensive use of the so-called Program-of-Record (PoR). In this regard, the Geostationary Atmospheric Composition Virtual Constellation consisting of the GEMS, TEMPO and SENTINEL-4 and other relevant geostationary assets will provide a critical foundation for A-CCP. In this talk we will discuss how the A-CCP measurements contributes to air-quality and the geostationary constellation, and conversely, how the geostationary constellation helps answering fundamental A-CCP science objectives.

Da Silva, Arlindo↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive to degradation parameter. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increasing of the resistivity with time of ageing. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.

Alexander A Teverovsky↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive to degradation parameter. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increasing of the resistivity with time of ageing. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.

Aging↗

Effect of High Temperature Storage on AC Characteristics of Polymer Tantalum Capacitors

Replacement of MnO2 with conductive polymers as cathode materials in chip tantalum capacitors allows for a substantial reduction of the equivalent series resistance (ESR), improvement of frequency characteristics, and elimination of the possibility of ignition during failures. One of the drawbacks of chip polymer tantalum capacitors (CPTCs) is a relatively poor long-term stability at high temperatures. In this work, variations of capacitance, dissipation factor, and ESR in different types of capacitors including automotive grade parts from three manufacturers have been monitored during storage at temperatures from 100 ºC to 175 ºC for up to 18,000 hours. Results show that ESR is the most and capacitance the least sensitive to degradation parameter. Times to parametric failures have been simulated using a Weibull-Arrhenius model that allowed for assessments of activation energies of the degradation and prediction of times to failure at the use temperature. Degradation of CPTCs was explained by thermo-oxidative processes in conductive polymers that result in exponential increasing of the resistivity with time of ageing. This process starts after a certain incubation period that depends on packaging materials and design and corresponds to the time that is necessary to form delamination between the encapsulating molding compound and lead frame. The effectiveness of the existing qualification procedures to assure stable operation of CPTCs is discussed.