Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using {sup 60}Co or {sup 192}Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference man defined in ICRP Publication 89. Point sources of {sup 60}Co or {sup 192}Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by {sup 60}Co source were smaller (8%-19%) than from {sup 192}Ir. However, as the distance increases, the more penetrating gamma rays produced by {sup 60}Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a {sup 60}Co source (11.1 mSv/Gy) is lower than from a {sup 192}Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced variations between both phantoms which were at most 35% in the considered organ equivalent doses. Finally, effective doses per clinical absorbed dose from IMRT and proton therapy were comparable to those from both brachytherapy sources, with brachytherapy being advantageous over external beam radiation therapy for the furthest organs. Conclusions: A database of organ equivalent doses when applying HDR brachytherapy to the prostate with either {sup 60}Co or {sup 192}Ir is provided. According to physical considerations, {sup 192}Ir is dosimetrically advantageous over {sup 60}Co sources at large distances, but not in the closest organs. Damage to distant healthy organs per clinical absorbed dose is lower with brachytherapy than with IMRT or protons, although the overall effective dose per Gy given to the prostate seems very similar. Given that there are several possible fractionation schemes, which result in different total amounts of therapeutic absorbed dose, advantage of a radiation treatment (according to equivalent dose to healthy organs) is treatment and facility dependent.

60 APPLIED LIFE SCIENCES↗

SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-539: Fixed Versus Variable Optimization Points in Combined-Mode Modulated Arc Therapy Planning

Purpose: A novel modulated arc therapy technique, mARC, enables superposition of step-and-shoot IMRT segments upon a subset of the optimization points (OPs) of a continuous-arc delivery. We compare two approaches to mARC planning: one with the number of OPs fixed throughout optimization, and another where the planning system determines the number of OPs in the final plan, subject to an upper limit defined at the outset. Methods: Fixed-OP mARC planning was performed for representative cases using Panther v. 5.01 (Prowess, Inc.), while variable-OP mARC planning used Monaco v. 5.00 (Elekta, Inc.). All Monaco planning used an upper limit of 91 OPs; those OPs with minimal MU were removed during optimization. Plans were delivered, and delivery times recorded, on a Siemens Artiste accelerator using a flat 6MV beam with 300 MU/min rate. Dose distributions measured using ArcCheck (Sun Nuclear Corporation, Inc.) were compared with the plan calculation; the two were deemed consistent if they agreed to within 3.5% in absolute dose and 3.5 mm in distance-to-agreement among > 95% of the diodes within the direct beam. Results: Example cases included a prostate and a head-and-neck planned with a single arc and fraction doses of 1.8 and 2.0 Gy, respectively. Aside from slightly more uniform target dose for the variable-OP plans, the DVHs for the two techniques were similar. For the fixed-OP technique, the number of OPs was 38 and 39, and the delivery time was 228 and 259 seconds, respectively, for the prostate and head-and-neck cases. For the final variable-OP plans, there were 91 and 85 OPs, and the delivery time was 296 and 440 seconds, correspondingly longer than for fixed-OP. Conclusion: For mARC, both the fixed-OP and variable-OP approaches produced comparable-quality plans whose delivery was successfully verified. To keep delivery time per fraction short, a fixed-OP planning approach is preferred.

60 APPLIED LIFE SCIENCES↗

SU-E-T-626: Practical Method to Implement Arc Therapy Using Scanned Particle Beams

Purpose: The purpose of this study was to propose a method to implement arc therapy that is compatible with existing particle therapy systems having gantries and pencil-beam scanning capacities. Furthermore, we sought to demonstrate expected benefits of this method for selected clival chordoma patients. Methods: We propose that a desired particle arc treatment plan can be discretized into a finite number of fixed beams and that only one (or a subset) of these beams be delivered in any single treatment fraction; the target should receive uniform dose during each fraction. For 3 clival-chordoma patients, robust-optimized, scanned proton beams were simulated to deliver 78 Gy (RBE) to clinical target volumes (CTVs), using either a single-field plan with a posterior-anterior (PA) beam or a discrete-arc plan with 16 beams that were equally spaced throughout a 360-degree axial arc. Dose-volume metrics were compared with emphasis on the brainstem, since risk of radiation necrosis there can often restrict application of tumoricidal doses for chordomas. Results: The mean volume of brainstem receiving a dose of 60 Gy (RBE) or higher (V60Gy) was 10.3±0.9 cm{sup 3} for the single-field plan and 4.7±1.8 cm{sup 3} for the discrete-arc plan, a reduction of 55% in favor of arcs. The mean dose to the brainstem was also reduced using arcs, by 18%, while the maximum dose was nearly identical for both methods. For the whole brain, V60Gy was reduced by 23%, in favor of arcs. Mean dose to the CTVs were nearly identical for both strategies, within 0.3%. Conclusion: Discrete arc treatments can be implemented using existing scanned particle-beam facilities. Aside from the physical advantages, the biological uncertainties of particle therapy, particularly high in the distal edge, can be reduced by arc therapy via rotational smearing, which may be of benefit for tumors near the brainstem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-675: Remote Dosimetry with a Novel PRESAGE Formulation

Purpose: 3D-gel dosimetry provides high-resolution treatment validation; however, scanners aren’t widely available. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote site for irradiation, then shipped back for scanning and analysis, affording a convenient service for treatment validation to institutions lacking the necessary equipment and resources. Previous works demonstrated the high-resolution performance and temporal stability of PRESAGE. Here the newest formulation is investigated for remote dosimetry use. Methods: A new formulation of PRESAGE was created with the aim of improved color stability post irradiation. Dose sensitivity was determined by irradiating cuvettes on a Varian Linac (6MV) from 0–15Gy and measuring change in optical density at 633nm. Sensitivity readings were tracked over time in a temperature control study to determine long-term stability. A large volume study was performed to evaluate the accuracy for remote dosimetry. A 1kg dosimeter was pre-scanned, irradiated on-site with an 8Gy 4field box treatment, post-scanned and shipped to Princess Margaret Hospital for remote reading on an identical scanner. Results: Dose sensitivities ranged from 0.0194–0.0295 ΔOD/(Gy*cm)—similar to previous formulations. Post-irradiated cuvettes stored at 10°C retained 100% initial sensitivity over 5 days and 98.6% over 10 weeks while cuvettes stored at room temperature fell to 95.8% after 5 days and 37.4% after 10 weeks. The immediate and 5-day scans of the 4field box dosimeter data was reconstructed, registered to the corresponding eclipse dose-distribution, and compared with analytical tools in CERR. Immediate and 5-day scans looked visually similar. Line profiles revealed close agreement aside from a slight elevation in dose at the edge in the 5-day readout. Conclusion: The remote dosimetry formulation exhibits excellent temporal stability in small volumes. While immediate and 5-day readout scans of large volume dosimeters show promising agreement, further development is required to reduce an apparent time dependent edge elevation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-BRD-00: Incident Learning / RO-ILS

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-01: Making Incident Learning Practical and Useful: Challenges and Previous Experiences

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-02: Henry Ford Hospital System Experience, with Focus On Motivating and Reviewing

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-03: UCSD Experience, with Focus On Implementing Change

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRD-04: UCLA Experience, with Focus On Developing Metrics and Using RO-ILS

It has long been standard practice in radiation oncology to report internally when a patient’s treatment has not gone as planned and to report events to regulatory agencies when legally required. Most potential errors are caught early and never affect the patient. Quality assurance steps routinely prevent errors from reaching the patient, and these “near misses” are much more frequent than treatment errors. A growing number of radiation oncology facilities have implemented incident learning systems to report and analyze both errors and near misses. Using the term “incident learning” instead of “event reporting” emphasizes the need to use these experiences to change the practice and make future errors less likely and promote an educational, non-punitive environment. There are challenges in making such a system practical and effective. Speakers from institutions of different sizes and practice environments will share their experiences on how to make such a system work and what benefits their clinics have accrued. Questions that will be addressed include: How to create a system that is easy for front line staff to access How to motivate staff to report How to promote the system as positive and educational and not punitive or demeaning How to organize the team for reviewing and responding to reports How to prioritize which reports to discuss in depth How not to dismiss the rest How to identify underlying causes How to design corrective actions and implement change How to develop useful statistics and analysis tools How to coordinate a departmental system with a larger risk management system How to do this without a dedicated quality manager Some speakers’ experience is with in-house systems and some will share experience with the AAPM/ASTRO national Radiation Oncology Incident Learning System (RO-ILS). Reports intended to be of value nationally need to be comprehensible to outsiders; examples of useful reports will be shown. There will be ample time set aside for audience members to contribute to the discussion. Learning Objectives: Learn how to promote the use of an incident learning system in a clinic. Learn how to convert “event reporting” into “incident learning”. See examples of practice changes that have come out of learning systems. Learn how the RO-ILS system can be used as a primary internal learning system. Learn how to create succinct, meaningful reports useful to outside readers. Gary Ezzell chairs the AAPM committee overseeing RO-ILS and has received an honorarium from ASTRO for working on the committee reviewing RO-ILS reports. Derek Brown is a director of http://TreatSafely.org . Brett Miller has previously received travel expenses and an honorarium from Varian. Phillip Beron has nothing to report.

60 APPLIED LIFE SCIENCES↗

MO-G-201-01: A Multi-Institutional Study Investigating the Performance of a Knowledge-Based Planning System Against Pinnacle Auto-Planning Engine in SIB-IMRT for the Head-And-Neck Cancer

Purpose: Knowledge-based Planning (KBP) founded on prior planning experience and Auto-Planning Engine (APE; commercialized in Pinnacle v9.10 TPS) based on progressive optimization algorithm both aim to eliminate the trial-and-error process in radiotherapy inverse planning. This study investigates the performance of the approaches in a multi-institutional setting to evaluate their functionalities in oropharyngeal cancer and offers suggestions how they can be implemented in the clinic. Methods: Radboud University Medical Center (RUMC) provided 35 oropharyngeal cancer patients (SIB-IMRT with two-dose-level prescription: 68 Gy to PTV68 and 50.3 Gy to PTV50.3) with corresponding comparative APE plans. Johns Hopkins University (JHU) contributed to a three-dose-level (70 Gy 63 Gy and 58.1 Gy) plan library for RUMC’s patient KBP generation. MedStar Georgetown University Hospital (MGUH) contributed to a KBP approach employing overlap-volume histogram (OVH-KBP) for generating RUMC’s patient KBP plans using JHU’s plan library. Since both approaches need their own user-defined parameters as initial inputs the first 10 patients were set aside as training set to finalize them. Meanwhile cross-institutional comparisons and adjustments were implemented for investigating institutions’ protocol discrepancies and the approaches’ user-defined parameters were updated accordingly. The finalized parameters were then applied to the remaining 25 patients for OVH-KBP and APE generation. A Wilcoxon rank-sum test was used for statistical comparison with significance level of p<0.05. Results: On average PTV68’s V95 was 96.5% in APE plans vs. 97% in OVH-KBP plans (p=0.36); PTV50.3’s V95 in APE plans was 97.8% vs.97.6% in OVH-KBP plans (p=0.6); cord’s D0.1 cc was 38.6 Gy in OVH-KBP plans vs. 43.7 Gy in APE plans (p=0.0001); mean doses to larynxes oral cavities parotids and submandibular glands were similar with p>0.2. Conclusions: The study demonstrates that KBP and APE can generate plans of comparable quality in a multi-institutional setting. Variations in clinical protocols can be effectively addressed for cross-institutional adaptations. Binbin Wu and Todd McNutt are the co-inventors of a patent associated with the proposed knowledge-based planning system which was licensed to Varian Medical Systems in 2015; This research was in part supported by Philips Radiation Oncology Systems.

60 APPLIED LIFE SCIENCES↗

3D exemplar-based random walks for tooth segmentation from cone-beam computed tomography images

Purpose: Tooth segmentation is an essential step in acquiring patient-specific dental geometries from cone-beam computed tomography (CBCT) images. Tooth segmentation from CBCT images is still a challenging task considering the comparatively low image quality caused by the limited radiation dose, as well as structural ambiguities from intercuspation and nearby alveolar bones. The goal of this paper is to present and discuss the latest accomplishments in semisupervised tooth segmentation with adaptive 3D shape constraints. Methods: The authors propose a 3D exemplar-based random walk method of tooth segmentation from CBCT images. The proposed method integrates semisupervised label propagation and regularization by 3D exemplar registration. To begin with, the pure random walk method is to get an initial segmentation of the teeth, which tends to be erroneous because of the structural ambiguity of CBCT images. And then, as an iterative refinement, the authors conduct a regularization by using 3D exemplar registration, as well as label propagation by random walks with soft constraints, to improve the tooth segmentation. In the first stage of the iteration, 3D exemplars with well-defined topologies are adapted to fit the tooth contours, which are obtained from the random walks based segmentation. The soft constraints on voxel labeling are defined by shape-based foreground dentine probability acquired by the exemplar registration, as well as the appearance-based probability from a support vector machine (SVM) classifier. In the second stage, the labels of the volume-of-interest (VOI) are updated by the random walks with soft constraints. The two stages are optimized iteratively. Instead of the one-shot label propagation in the VOI, an iterative refinement process can achieve a reliable tooth segmentation by virtue of exemplar-based random walks with adaptive soft constraints. Results: The proposed method was applied for tooth segmentation of twenty clinically captured CBCT images. Three metrics, including the Dice similarity coefficient (DSC), the Jaccard similarity coefficient (JSC), and the mean surface deviation (MSD), were used to quantitatively analyze the segmentation of anterior teeth including incisors and canines, premolars, and molars. The segmentation of the anterior teeth achieved a DSC up to 98%, a JSC of 97%, and an MSD of 0.11 mm compared with manual segmentation. For the premolars, the average values of DSC, JSC, and MSD were 98%, 96%, and 0.12 mm, respectively. The proposed method yielded a DSC of 95%, a JSC of 89%, and an MSD of 0.26 mm for molars. Aside from the interactive definition of label priors by the user, automatic tooth segmentation can be achieved in an average of 1.18 min. Conclusions: The proposed technique enables an efficient and reliable tooth segmentation from CBCT images. This study makes it clinically practical to segment teeth from CBCT images, thus facilitating pre- and interoperative uses of dental morphologies in maxillofacial and orthodontic treatments.

60 APPLIED LIFE SCIENCES↗

Global Transcriptomic and Proteomic Responses of Dehalococcoides ethenogenes Strain 195 to Fixed Nitrogen Limitation

Bacteria of the genus Dehalococcoides play an important role in the reductive dechlorination of chlorinated ethenes. A systems level approach was taken in this study to examine the global transcriptomic and proteomic responses of exponentially growing D. ethenogenes strain 195 to fixed nitrogen limitation (FNL) as dechlorination activity and cell yield both decrease during FNL. As expected, the nitrogen-fixing (nif) genes were differentially up-regulated in the transcriptome and proteome of strain 195 during FNL. Aside from the nif operon, a putative methylglyoxal synthase-encoding gene (DET1576), the product of which is predicted to catalyze the formation of the toxic electrophile methylglyoxal and implicated in the uncoupling of anabolism from catabolism in bacteria, was strongly up-regulated in the transcriptome and could potentially play a role in the observed growth inhibition during FNL. Carbon catabolism genes were generally down regulated in response to FNL and a number of transporters were differentially regulated in response to nitrogen limitation, with some playing apparent roles in nitrogen acquisition while others were associated with general stress responses. A number of genes related to the functions of nucleotide synthesis, replication, transcription, translation, and post-translational modifications were also differentially expressed. One gene coding for a putative reductive dehalogenase (DET1545) and a number coding for oxidoreductases, which have implications in energy generation and redox reactions, were also differentially regulated. Interestingly, most of the genes within the multiple integrated elements were not differentially expressed. Overall, this study elucidates the molecular responses of strain 195 to FNL and identifies differentially expressed genes that are potential biomarkers to evaluate environmental cellular nitrogen status.

59 BASIC BIOLOGICAL SCIENCES↗

Genome Sequence of the Obligate Gammaproteobacterial Methanotroph Methylomicrobium album strain BG8

The complete genome sequence of Methylomicrobium album BG8, a methane-oxidizing gammaproteobacterium isolated from freshwater, is reported. Aside from conserved inventory for growth on single-carbon compounds, M. album BG8 encodes a range of inventory for additional carbon and nitrogen transformations, but no genes for growth on multi-carbon substrates or for N-fixation.

Kits, K. Dimitri↗

Surface Modification of Rock-Forming Minerals of Diamond-Bearing Kimberlites under Interaction with Wastewater and Electrochemically Treated Water

The structural and chemical surface transformation of basic kimberlite-forming minerals (calcite, olivine, serpentine) under the contact with natural and waste mineralized water and products of electrochemical treatment of the water are studied using X-ray photoelectronic spectroscopy, scanning electron microscopy and X-ray spectral micro-analysis, and atomic force microscopy. It is found that contact with kimberlite extract and recycling water induces chemical modification of calcite surface, which consists in adsorption of hydrocarbon impurities, and chlorine- and silica-bearing compounds, majority of which are removed during interaction with the product of electrochemical treatment of recycling water. The change in the structural and chemical surface properties of rock-forming silicates, aside from adsorption–desorption of organic compound, is also connected with the distortion of nano-size layer structure after leaching of Mg, Fe and Si, and with the carbonatization of the surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization observables in three-nucleon systems

In the past two decades, several laboratories have produced a large amount of data for cross sections, analyzing powers, and other spin observables from various reactions in the three-nucleon system. The results allow one to arrive at a moderately good description of the data by only using the two-nucleon potentials in Faddeev-type calculations. The remaining discrepancies should, in principle, and aside from Coulomb and relativistic effects, be removed once the effects of three-nucleon forces are implemented. High precision data on elastic and break-up reactions show, however, that even after the inclusion of these effects, the picture is not complete yet and some ingredients are still missing in the calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Some challenging points in the identification of defects in floating-zone n-type silicon irradiated with 8 and 15 MeV protons

Electrical properties of defects formed in n-Si(FZ) following 8 and 15 MeV proton irradiation are investigated by Hall effect measurements over the wide temperature range of T ≈ 25 to 300 K. Close attention is paid to the damaging factor of proton irradiation, leaving aside passivation effects by hydrogen. The concept of defect production and annealing processes being accepted in the literature so far needs to be reconsidered. Contrary to expectations the dominant impurity-related defects produced by MeV protons turn out to be electrically neutral in n-type material. Surprisingly, radiation acceptors appear to play a minor role. Annealing studies of irradiated samples of such complex defects as a divacancy tied to a phosphorus atom and a vacancy tied to two phosphorus atoms. The latter defect features high thermal stability. Identification of the dominant neutral donors, however, remains unclear and will require further, more detailed, studies. The electric properties of the material after proton irradiation can be completely restored at T = 800°C.

36 MATERIALS SCIENCE↗

Experimental Measures of Fission Time Scales

The nuclear fission process involves a drastic rearrangement of the nuclear matter of the fissioning system as it undergoes shape changes from a single, compact nucleus to two separated fission fragments. Understanding the dynamics of this process has been the focus of much research for decades, both theoretical and experimental, using a number of different approaches. Early on, Kramers [1] proposed that the fission rate is not well described by the statistical counting of transition states as proposed by Bohr and Wheeler [2] but that the friction or viscosity of the nuclear matter can play a substantial role in slowing down the rate by large factors. Aside from the theoretical estimates of fission time scales, a number of different approaches have been used to obtain experimental information on this quantity. Although the divergence of results obtained by the different experimental approaches have been known for years, these discrepancies have not yet been resolved and they have recently received renewed attention [3]. In this paper I will recount some of the experimental approaches to estimate the fission time scales and discuss their respective strengths and weaknesses without coming close to provide a resolution of the discrepancies.

Back, B. B.↗