Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Prevention of trace and major element leaching from coal combustion products by hydrothermally-treated coal ash

The most important structural components of coal ash obtained by coal combustion in 'Nikola Tesla A' power plant located near Belgrade (Serbia) are amorphous alumosilicate, alpha-quartz, and mullite. The phase composition of coal ash can be altered to obtain zeolite type NaA that crystallizes in a narrow crystallization field (SiO{sub 2}/Al{sub 2}O{sub 3}; Na{sub 2}O/SiO{sub 2}; H{sub 2}O/Na{sub 2}O ratios). Basic properties (crystallization degree, chemical composition, the energy of activation) of obtained zeolites were established. Coal ash extracts treated with obtained ion-exchange material showed that zeolites obtained from coal ash were able to reduce the amounts of iron, chromium, nickel, zinc, copper, lead, and manganese in ash extracts, thus proving its potential in preventing pollution from dump effluent waters.

01 COAL, LIGNITE, AND PEAT↗

pH-dependent leaching of dump coal ash - retrospective environmental analysis

Trace and major elements in coal ash particles from dump of 'Nikola Tesla A' power plant in Obrenovac near Belgrade (Serbia) can cause pollution, due to leaching by atmospheric and surface waters. In order to assess this leaching potential, dump ash samples were subjected to extraction with solutions of decreasing pH values (8.50, 7.00, 5.50, and 4.00), imitating the reactions of the alkaline ash particles with the possible alkaline, neutral, and acidic (e.g., acid rain) waters. The most recently deposited ash represents the greatest environmental threat, while 'aged' ash, because of permanent leaching on the dump, was shown to have already lost this pollution potential. On the basis of the determined leachability, it was possible to perform an estimation of the acidity of the regional rainfalls in the last decades.

01 COAL, LIGNITE, AND PEAT↗

Tetrafluoroboric Acid Digestion for Accurate Determination of Rare Earth Elements in Coal and Fly Ash by ICP-MS Analysis

Coal and coal-related fly ash often contain rare earth elements (REEs) that have the potential to be utilized as valuable mineral resources. Accurately determining the REE content in coal and fly ash is crucial for resource evaluation. The conventional approach involves using hydrofluoric acid (HF) to dissolve silicates and release REEs, which, however, prolongs the digestion process due to the additional step of complexing fluoride ions (F−) with boric acid (H3BO3). Determining the correct amount of H3BO3 for neutralization can be challenging, and in some instances, the binding of fluoride ions with certain lanthanides (Lns) hampers the accurate determination of all 14 naturally occurring rare earth elements in a single digestion batch by inductively coupled plasma mass spectrometry (ICP-MS). In this study, we present an alternative method that achieves the accurate determination of all 14 naturally occurring REEs using tetrafluoroboric acid (HBF4) followed by ICP-MS analysis. This approach eliminates the need for an F− complexing step. We tested this method on certified REE reference materials, including NIST 1632e (coal) and NIST 1633c (fly ash), as well as the REE geological reference material USGS AGV-1 (andesite). Our results demonstrated excellent recovery rates (relative standard deviation, RSD < ±10%), with a correlation coefficient (r2) exceeding 0.99. Using this method, we investigated the concentrations of all 14 REEs in coal and fly ash samples collected from various locations in the southwestern USA. This improved digestion technique streamlines the analysis process and enhances the accuracy of REE determination, facilitating a more comprehensive evaluation of REE-rich coal and fly ash deposits for resource exploration.

58 GEOSCIENCES↗

Leaching kinetics of As, Mo, and Se from acidic coal fly ash samples

Annually, coal-fired electric power plants produce large volumes potentially hazardous coal combustion products (CCPs) including fly ash. Since majority of the coal fly ash and other CCPs deposited in dry land fills or wet lagoons, they pose risk of contamination to local environment and hydrogeology. In this study, we present results of leaching kinetics for As, Mo, and Se from three acidic fly ash samples. This study shows that the leachate concentrations of As, Mo, and Se increase over time. Three kinetics equations, pseudo-second order, Elovich, and power-function, are able to adequately describe the experimental leaching kinetics data. Experimental leaching data and modeling results indicate that the rate limiting leaching of As, Mo, and Se is largely controlled by the dissolution of the fly ash particles. Furthermore, it is important to adopt effective containment/treatment schemes to avoid potential and persistent dispersion of trace elements from ash disposal facilities to surrounding environment for a long time.

54 ENVIRONMENTAL SCIENCES↗

Fire Induced Rock Spalls as Long-Term Traps for Ash

Severe fires accelerate rock weathering by spalling and exfoliation, creating abundant peels, flakes or spalls. In the following years, these spalls serve as physical traps which accommodate fine particles of dust, ash, organic matter, etc. We searched for traces of ash trapped under the spalls, after four major fires: 1989, 2005, 2010 and 2015 in Israel. Samples were collected beneath the spalls that formed on the rock outcrops, and in the immediate vicinity above and below them. Three laboratory analyses were performed: pH, EC and color. Five mineral/organic compounds were measured across the Mid-Infrared (MIR) spectral region at diffuse reflectance infrared Fourier transform mode: Hydroxylapatite (HAp), charcoal, organic carbon, montmorillonite and kaolinite. Several statistical analyses were performed: MANOVA, PCA and silhouette analysis on K-means clustering. The results show evidence of ash trapped under the spalls formed during the 2005 and 2010 fires, 6 to 11 years after the fires. Charcoal presence is evident, as well as increased amounts of HAp and organic carbon. In the exposed soil above or below the burned rock outcrop, these values are lower. Negligible amounts of ash were measured 27 years after the fire. In the 2015 burned outcrop, large amounts of charcoal were found above and below the outcrop, but not under the spalls. It seems that on the carbonate slopes of Israel and under Mediterranean climate, the time required for spalls to begin functioning as traps is longer than one rainy season, while ash traces are preserved in these traps for a period of two-three decades.

ash↗

Superheater Tube Corrosion in Wood Gasifier Ash Deposits

The upper operating temperature of tubes in heat exchangers/steam generators is strongly influenced by the degradation that can occur because of the reaction of the exchanger/generator tubing with the deposits that accumulate on the surface of the tubes. In fact, severe corrosion has been observed in some biomass fired systems, particularly with elevated potassium and chlorine concentrations in the deposits. Wood gasifiers have recently been and are currently being constructed at several sites in North America. In these systems, the syngas is burned to produce steam and the performance of the heat exchanger tubes under ash deposits is of great concern. As temperatures of the heat exchangers are increased in an effort to increase their operating efficiency, the performance of the tubes is of greater interest. The corrosion behavior of alloy steel tubes as a function of temperature has been investigated by exposing samples of selected alloys to ash collected from the steam generator fired by syngas produced in wood gasifiers. This study compares corrosion rates from laboratory exposures of synthesis gas and ash at 500 C and 600 C. This study investigated the material performance of four ferritic steels and one austenitic steel exposed to conditions expected on the fireside of a wood gasifier. The purpose of this study was to identify an effective method for determining material performance for samples exposed to both the process gas and the fly ash that is typically observed within the steam generator for times up to 1000 hours. Mass changes were measured for all of the samples, but this information can be misleading concerning material performance due to the difficulty in sufficiently cleaning the samples after exposure in the ash. Therefore, small cross sections of the samples were collected and imaged using optical microscopy. Oxide thicknesses were measured along with metal losses. The metal loss information provides a clear indication of material performance. The metal loss rates for the ferritic steels at 500 C were almost half of those observed at 600 C and the rates decreased with increasing exposure time. It was also reported that the metal loss rates generally decrease with increasing chromium concentration.

09 BIOMASS FUELS↗

Concordant plutonium-241-americium-241 dating of environmental samples: results from forest fire ash

We have measured the Pu, {sup 237}Np, {sup 241}Am, and {sup 151}Sm isotopic systematics for a set of forest fire ash samples from various locations in the western U.S. including Montana, Wyoming, Idaho, and New Mexico. The goal of this study is to develop a concordant {sup 241}Pu (t{sub 1/2} = 14.4 y)-{sup 241}Am dating method for environmental collections. Environmental samples often contain mixtures of components including global fallout. There are a number of approaches for subtracting the global fallout component for such samples. One approach is to use {sup 242}/{sup 239}Pu as a normalizing isotope ratio in a three-isotope plot, where this ratio for the nonglobal fallout component can be estimated or assumed to be small. This study investigates a new, complementary method of normalization using the long-lived fission product, {sup 151}Sm (t{sub 1/2} = 90 y). We find that forest fire ash concentrates actinides and fission products with {approx}1E10 atoms {sup 239}Pu/g and {approx}1E8 atoms {sup 151}Sm/g, allowing us to measure these nuclides by mass spectrometric (MIC-TIMS) and radiometric (liquid scintillation counting) methods. The forest fire ash samples are characterized by a western U.S. regional isotopic signature representing varying mixtures of global fallout with a local component from atmospheric testing of nuclear weapons at the Nevada Test Site (NTS). Our results also show that {sup 151}Sm is well correlated with the Pu nuclides in the forest fire ash, suggesting that these nuclides have similar geochemical behavior in the environment. Results of this correlation indicate that the {sup 151}Sm/{sup 239}Pu atom ratio for global fallout is {approx}0.164, in agreement with an independent estimate of 0.165 based on {sup 137}Cs fission yields for atmospheric weapons tests at the NTS. {sup 241}Pu-{sup 241}Am dating of the non-global fallout component in the forest fire ash samples yield ages in the late 1950's-early 1960's, consistent with a peak in NTS weapons testing at that time. The age results for this component are in agreement using both {sup 242}Pu and {sup 151}Sm normalizations, although the errors for the {sup 151}Sm correction are currently larger due to the greater uncertainty of their measurements. Additional efforts to develop a concordant {sup 241}Pu-{sup 241}Am dating method for environmental collections are underway with emphasis on soil cores.

54 ENVIRONMENTAL SCIENCES↗

Chloride chemical form in various types of fly ash

Chloride content is a critical problem for the reuse of fly ash as a raw material in cement, and the method used by recyclers to reduce the fly ash chloride content depends on the chemical form of the chlorides. However, limited information is available on the quantitative distribution of chlorides and the identity of some chlorides such as Friedel's salt. We examined chloride forms and percentages using X-ray absorption near edge structure and X-ray diffraction analyses, as well as corresponding washing experiments. Approximately 15% of the chlorine in raw fly ash was estimated to be in the form of NaCl, 10% in KCl, 50% in CaCl{sub 2}, and the remainder in the form of Friedel's salt. Fly ash collected in a bag filter with the injection of calcium hydroxide for acid gas removal (CaFA) contained 35% chlorine as NaCl, 11% as KCl, 37% as CaCl{sub 2}, 13% as Friedel's salt, and the remaining 4% as CaClOH. In fly ash collected in a bag filter with the injection of sodium bicarbonate for acid gas removal (NaFA), approximately 79% of chlorine was in NaCl, 12% was in KCl, and 9% was in Friedel's salt. 25 refs., 4 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Petrographic characterization of economizer fly ash

Policies for reducing NOx emissions have led power plants to restrict O{sub 2}, resulting in high-carbon fly ash production. Therefore, some potentially useful fly ash, such as the economizer fly ash, is discarded without a thorough knowledge of its composition. In order to characterize this type of fly ash, samples were collected from the economizer Portuguese power plant burning two low-sulfur bituminous coals. Characterization was also performed on economizer fly ash subsamples after wet sieving, density and magnetic separation. Analysis included atomic absorption spectroscopy, loss-on-ignition, scanning electron microscopy/energy-dispersive X-ray spectroscopy, optical microscopy, and micro-Raman spectroscopy.

01 COAL, LIGNITE, AND PEAT↗

Alteration of municipal solid waste incineration bottom ash focusing on the evolution of iron-rich constituents

Municipal solid waste incineration (MSWI) bottom ash contains a considerable amount of Fe-rich constituents. The behaviors of these constituents, such as dissolution and precipitation, are quite important as they regulate the distribution of a series of ions between the liquid (percolated fluid) and solid (ash deposit) phases. This paper studied both fresh and weathered MSWI bottom ash from the mineralogical and geochemical viewpoint by utilizing optical microscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX), and powder X-ray diffraction. The analysis results revealed that for the fresh bottom ash, iron preferentially existed in the chemical forms of spinel group (mainly Fe{sub 3}O{sub 4}, and a series of Al- or Ti- substituted varieties), metallic inclusions (including Fe-P, Fe-S, Fe-Cu-Pb), hematite (Fe{sub 2}O{sub 3}) and unburned iron pieces. In the 1-20 years weathered bottom ash collected from a landfill site, interconversions among these Fe-rich constituents were identified. Consequently, numerous secondary products were developed, including goethite ({alpha}-FeOOH), lepidocrocite ({gamma}-FeOOH), hematite, magnetite, wustite (FeO), Fe-Si-rich gel phase. Of all these transformation products, hydrous iron oxides were the most common secondary minerals. Quantitative chemical analysis of these secondary products by SEM/EDX disclosed a strong association between the newly formed hydrous iron oxides and heavy metals (e.g. Pb, Zn, Ni, and Cu). The results of this study suggest that the processes of natural weathering and secondary mineralization contribute to reduction of the potential risks of heavy metals to the surrounding environments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Study of an Incinerator Ash Conveyor Counting System - 13323

A design study has been performed for a system that should measure the Cs-137 activity in ash from an incinerator. Radioactive ash, expected to consist of both Cs-134 and Cs-137, will be transported on a conveyor belt at 0.1 m/s. The objective of the counting system is to determine the Cs-137 activity and direct the ash to the correct stream after a diverter. The decision levels are ranging from 8000 to 400000 Bq/kg and the decision error should be as low as possible. The decision error depends on the total measurement uncertainty which depends on the counting statistics and the uncertainty in the efficiency of the geometry. For the low activity decision it is necessary to know the efficiency to be able to determine if the signal from the Cs-137 is above the minimum detectable activity and that it generates enough counts to reach the desired precision. For the higher activity decision the uncertainty of the efficiency needs to be understood to minimize decision errors. The total efficiency of the detector is needed to be able to determine if the detector will be able operate at the count rate at the highest expected activity. The design study that is presented in this paper describes how the objectives of the monitoring systems were obtained, the choice of detector was made and how ISOCS (In Situ Object Counting System) mathematical modeling was used to calculate the efficiency. The ISOCS uncertainty estimator (IUE) was used to determine which parameters of the ash was important to know accurately in order to minimize the uncertainty of the efficiency. The examined parameters include the height of the ash on the conveyor belt, the matrix composition and density and relative efficiency of the detector. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reactive transport modeling and characterization of concrete materials with fly ash replacement under carbonation attack - 15477

There currently lacks sufficient knowledge to accurately characterize structural, hydraulic, and chemical performance of cementitious materials that are required to contain and shield nuclear waste for thousands of years. There are a number of degradation methods that can affect the integrity of these materials over this time frame including carbonation which lowers the alkalinity of the material and can induce cracking in materials with steel reinforcement. The rate and extent of carbonation in these materials is impacted by the addition of fly ash and its composition which can vary depending on the fly ash source. To characterize the carbonation reaction, the changes in the microstructure and elemental distribution as a function of extent of carbonation and fly ash type were evaluated using scanning electron microscopy (SEM) coupled with energy dispersive x-ray spectroscopy (EDS). Micro-concretes were prepared with no fly ash (control case) and with fly ash of various calcium compositions. The progression of the carbonation front was observed in the backscattered electron images by the formation of calcium carbonate and depth was confirmed with a phenolphthalein pH indicator test. The migration and deposition of chemical species were observed in carbonated regions from EDS data and were explained based on the changes in material alkalinity and solubility determined from EPA Method 1313 (Liquid-solid partitioning (LSP) as a function of eluate pH). The changes in mass transport properties from carbonation were observed using EPA Method 1315 (Mass transfer rates in monolithic and compacted granular materials using semi-dynamic tank leaching procedures). The carbonation reaction in each material was simulated using LeachXS/ORCHESTRA, a reactive transport modeling tool, which provided further evidence of localized deposition and migration of chemical species due to changes in speciation and solubility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coal fly ash interaction with environmental fluids: Geochemical and strontium isotope results from combined column and batch leaching experiments

The major element and Sr isotope systematics and geochemistry of coal fly ash and its interactions with environmental waters were investigated using laboratory flow-through column leaching experiments (sodium carbonate, acetic acid, nitric acid) and sequential batch leaching experiments (water, acetic acid, hydrochloric acid). Column leaching of Class F fly ash samples shows rapid release of most major elements early in the leaching procedure, suggesting an association of these elements with soluble and surface bound phases. Delayed release of certain elements (e.g., Al, Fe, Si) signals gradual dissolution of more resistant silicate or glass phases as leaching continues. Strontium isotope results from both column and batch leaching experiments show a marked increase in {sup 87}Sr/{sup 86}Sr ratio with continued leaching, yielding a total range of values from 0.7107 to 0.7138. For comparison, the isotopic composition of fluid output from a fly ash impoundment in West Virginia falls in a narrow range around 0.7124. The experimental data suggest the presence of a more resistant, highly radiogenic silicate phase that survives the combustion process and is leached after the more soluble minerals are removed. Strontium isotopic homogenization of minerals in coal does not always occur during the combustion process, despite the high temperatures encountered in the boiler. Early-released Sr tends to be isotopically uniform; thus the Sr isotopic composition of fly ash could be distinguishable from other sources and is a useful tool for quantifying the possible contribution of fly ash leaching to the total dissolved load in natural surface and ground waters.

01 COAL, LIGNITE, AND PEAT↗

Major element composition controls rare earth element solubility during leaching of coal fly ash and coal by-products

Coal combustion ash and pre-combustion coal refuse are currently under consideration as potential sources of rare earth elements. One of the early steps in recovering REEs from coal by-products is often acid leaching, which can result in low pH leachates with complex aqueous chemistry. The aim of this work was to understand the connection between REE solubility, pH, and major elemental components of leachates for coal by-products. To accomplish this, we investigated the effects of solids concentration (i.e., pulp density) and pH adjustment on REE solubility in acid leachates of coal fly ashes from the Powder River Basin (PRB) and Appalachian Basin in the United States, and a coal processing refuse from the Southwestern U.S. For PRB ashes, the concentrations of soluble REEs generally increased with increasing pulp density; however, at pulp density values above 80–100 g/L, the soluble REE concentrations in the leachates were markedly lower. Similarly, the soluble concentrations of other major solutes (Fe, Al, Si) that leached from PRB fly ashes were also non-linear with pulp density. These major elements tended to reach maximum concentration values at 60–70 g/L pulp density. In contrast, for the Appalachian fly ashes and the coal by-product, soluble concentrations of REE and major elements in leachates increased linearly with pulp density. Chemical equilibria calculations of mineral saturation indices indicated that trends in soluble REE concentrations could be explained by saturation conditions for Fe and Al-(hydr)oxides and possibly sulfate minerals, but not lanthanide hydroxides. Furthermore, pH adjustment of the acid leachates showed that REEs and many major solutes were removed from solution at pH values above 4.5, also consistent with Fe- and Al-(hydr)oxide precipitation. These results highlight the importance of understanding the chemical composition of leachates when designing REE recovery processes for low-grade geologic feedstocks and that precipitation of hydr(oxide) or sulfate minerals of major elements rather than discreet formation of REE mineral phases could be used for process optimization.

01 COAL, LIGNITE, AND PEAT↗

Radiative Properties of Coal Ash Deposits with Sintering Effects

The heat-transfer characteristics in the fireside of a pulverized-coal furnace are affected, among other factors, by the physical and chemical characteristics of the ash deposits. Indeed, the physical state of the ash deposits and their chemical composition determine the radiative and conductive properties of the furnace walls. Particularly, several complex mechanisms are involved in the radiative heat-transfer process at the walls that restricts the absorption of the incident radiation of the flame, particles, and hot gases. These mechanisms involve dependencies on the radiation spectrum due to the ash chemical composition and ash-sintering effects that enhance or hinder the overall heat transfer. In this work, the complex mechanisms that describe the heat exchange in the presence of ash deposits and their impact on the prediction of the wall emissivity and ultimately the wall heat transfer in a real system are discussed.

01 COAL, LIGNITE, AND PEAT↗

Facilitating Implementation of High-Volume Fly Ash Use in Pre-cast Concrete Construction to Increase Beneficial Utilization

The main goal of this project was to increase the beneficial use of fly ash as a supplementary cementitious material for precast concrete applications. A major focus was to develop balanced concrete mix design strategies which collectively satisfy the follow objectives: 1) increase fly ash beneficial use by at least 15% in the precast concrete industry, 2) maintain or exceed stringent structural property requirements (e.g., compressive strength at initial prestress, modulus of rupture, etc.), 3) exhibit little or no additional cost relative to conventional mixtures, and 4) mitigate detrimental environmental consequences inadvertently caused by increased beneficial use. Outcomes from this project include recommendations for design guidelines and code provisions for sustainable concrete mix designs, facilitating diversion and harvesting of large quantities of fly ash from landfills or impoundments, and multiple frameworks for incorporating discarded fly ash materials (i.e., landfilled or ponded fly ash after separating the impurities) in concrete construction.

01 COAL, LIGNITE, AND PEAT↗

Coal Ash Corrosion Resistant Materials Testing

In April 1999, three identical superheater test sections were installed into the Niles Unit No.1 for the purpose of testing and ranking the coal ash corrosion resistance of candidate superheater alloys. The Niles boiler burns high sulfur coal (3% to 3.5%) that has a moderate alkali content (0.2% sodium equivalents), thus the constituents necessary for coal ash corrosion are present in the ash. The test sections were controlled to operate with an average surface metal temperature from approximately 1060 F to 1210 F which was within the temperature range over which coal ash corrosion occurs. Thus, this combination of aggressive environment and high temperature was appropriate for testing the performance of candidate corrosion-resistant tube materials. Analyses of the deposit and scale confirmed that aggressive alkali sulfate constituents were present at the metal surface and active in tube metal wastage. The test sections were constructed so that the response of twelve different candidate tube and/or coating materials could be studied. The plan was to remove and evaluate one of the three test sections at time intervals of 1 year, 3 years, and 5 years. This would permit an assessment of performance of the candidate materials as a function of time. Test Section A was removed in November 2001 after about 24 months of service at the desired steam temperature set point, with about 15.5 months of exposure at full temperature. A progress report, issued in October 2002, was written to document the performance of the candidate alloys in that test section. The evaluation described the condition of each tube sample after exposure. It involved a determination of the rate of wall thickness loss for these samples. In cases where there was more than one sample of a candidate material in the test section, an assessment was made of the performance of the alloy as a function of temperature. Test Sections B and C were examined during the November 2001 outage, and it was decided that, due to excessive wastage, certain tube samples needed to be removed and replaced in order to ensure that Test Sections B and C would have a chance of remaining in the boiler for their intended exposure period. These suspect tube samples were replaced and the two remaining test sections were put back into service. The tube samples that were removed from Test Sections B and C were set aside for later analysis at the end of the planned exposure period. Test Sections B and C were again examined approximately six months later. At that time, measured wall thickness losses raised concerns about additional tube samples. These suspect samples were also removed, set aside for later analysis, and replaced. The test sections then went back into service until the end of the second exposure period, which was concluded in May 2003 when, due to evidence of excessive wastage, the valves were opened increasing cooling steam flow and thereby effectively stopping corrosion. In August 2003, Test Sections B and C were removed for closer examination. Section C had experienced about 42 months of service at the desired team temperature set point with 28.5 months at temperature at full temperature. Additional suspect samples were removed from Test Section B, then, it was re-installed into the boiler (at the location originally occupied by Section C), where it remained in service until the end of the program. Due to this removal history, the samples from Test Section B had a total service duration that varied from a minimum of 15.5 months (for samples that performed poorly) to 37 months for samples the survived for the full intended service exposure for Section B. The figure below shows a schematic of Test Section B and indicates the length of service exposure for different locations. This report provides the results of the evaluation of Test Section B, including the samples that remained in the Test Section for the full exposure period as well as those that were removed early. This report also is intended to compare and summarize the results for all three test sections. The analysis of Test Section B followed much the same protocol that was employed in the assessment of the other two test sections. The focus was on determining and documenting the relative corrosion rates of the candidate materials; however, additional investigations were undertaken to better understand the wastage mechanism, and to characterize how selected candidate materials performed either well, or poorly, in the severe coal ash corrosion environment in the convection pass of Niles Unit No.1. The detailed results of the investigation are included in this report as a series of twelve appendices. Each appendix is devoted to the performance of one of the candidate alloys. The table below summarizes metal loss rate for the worst case sample of each of the candidate materials in all three test sections. The body of this report compares these for all of the samples in the test section.

01 COAL, LIGNITE, AND PEAT↗

Ash loading and insolation at Hanford, Washington during and after the eruption of Mount St. Helens

The effects of volcanic ash suspended in the atmosphere on the incident solar radiation was monitored at the Hanford Meteorological Station (HMS) subsequent to the major eruption of Mount St. Helens on May 18, 1980. Passage of the ash plume over Hanford resulted in a very dramatic decrease of solar radiation intensity to zero. A reduction in visibility to less than 1 km was observed, as great quantities of ash fell out of the plume onto the ground. Ash loading in the atmosphere remained very high for several days following the eruption, primarily as a result of resuspension from the surface. Visibilities remained low (2 to 8 km) during this period. Estimates of atmospheric turbidity were made from the ratio of diffuse-to-direct solar radiation; these turbidities were used to estimate extinction along a horizontal path, a quantity which can be related to visibility. Comparisons of observed and estimated visibilities were very good, in spite of the rather coarse approximations used in the estimates. Atmospheric clarity and visibility improved to near pre-eruption conditions following a period of rain showers. The diffuse-to-direct ratio of solar radiation provided a useful index for estimating volcanic ash loading of the atmosphere.

Laulainen, N. S.↗