Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACCURACY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Astrometric telescope of ten microarcsecond accuracy on the Space Station

The Astrometric Telescope Facility (ATF) will be operated in the NASA Space Station in the 1990s, furnishing long term, highly accurate relative astrometry of nearby stars in order to detect gravitational perturbations by companion stars with masses as small as that of Neptune. An accuracy of 10 microarcsec is required; this is 100 times better than ground observatory performance. In the Gatewood et al. (1980) astrometric technique used, the relative positions of star images in the telescope focal plane are indicated by the relative phases of the modulations of star brightnesses introduced by translating a Ronchi ruling across the focal plane at uniform speed. Space Station vibration damping, fine guiding accuracy, optical configuration, Ronchi ruling metric accuracy, and the choice of detectors, are discussed.

Levy, E. H.↗

Accuracies of southwell and force/stiffness methods in the prediction of buckling strength of hypersonic aircraft wing tubular panels

Accuracies of the Southwell method and the force/stiffness (F/S) method are examined when the methods were used in the prediction of buckling loads of hypersonic aircraft wing tubular panels, based on nondestructive buckling test data. Various factors affecting the accuracies of the two methods were discussed. Effects of load cutoff point in the nondestructive buckling tests on the accuracies of the two methods were discussed in great detail. For the tubular panels under pure compression, the F/S method was found to give more accurate buckling load predictions than the Southwell method, which excessively overpredicts the buckling load. It was found that the Southwell method required a higher load cutoff point, as compared with the F/S method. In using the F/S method for predicting the buckling load of tubular panels under pure compression, the load cutoff point of approximately 50 percent of the critical load could give reasonably accurate predictions.

Ko, William L.↗

Total Variation Diminishing (TVD) schemes of uniform accuracy

Explicit second-order accurate finite-difference schemes for the approximation of hyperbolic conservation laws are presented. These schemes are nonlinear even for the constant coefficient case. They are based on first-order upwind schemes. Their accuracy is enhanced by locally replacing the first-order one-sided differences with either second-order one-sided differences or central differences or a blend thereof. The appropriate local difference stencils are selected such that they give TVD schemes of uniform second-order accuracy in the scalar, or linear systems, case. Like conventional TVD schemes, the new schemes avoid a Gibbs phenomenon at discontinuities of the solution, but they do not switch back to first-order accuracy, in the sense of truncation error, at extrema of the solution. The performance of the new schemes is demonstrated in several numerical tests.

Hartwich, PETER-M.↗

Accuracy of a class of concurrent algorithms for transient finite element analysis

The accuracy of a new class of concurrent procedures for transient finite element analysis is examined. A phase error analysis is carried out which shows that wave retardation leading to unacceptable loss of accuracy may occur if a Courant condition based on the dimensions of the subdomains is violated. Numerical tests suggest that this Courant condition is conservative for typical structural applications and may lead to a marked increase in accuracy as the number of subdomains is increased. Theoretical speed-up ratios are derived which suggest that the algorithms under consideration can be expected to exhibit a performance superior to that of globally implicit methods when implemented on parallel machines.

Ortiz, Michael↗

Accuracy analysis of the semi-analytical method for shape sensitivity calculation

The semianalytical method, widely used for calculating derivatives of static response with respect to design variables for structures modeled by finite elements, is studied in this paper. The paper shows that the method can have serious accuracy problems for shape design variables in structures modeled by beam, plate, truss, frame, and solid elements. The errors are shown to be associated with the structural model. An error index is developed to test the accuracy of the semianalytical method. It characterizes the difference in errors between a general finite-difference method and the semianalytical method. Moreover, a method for improving the accuracy of the semianalytical method (when possible) is provided. Examples are presented to demonstrate the use of the error index.

Barthelemy, Bruno↗

Evaluation of ERBE scanner pointing accuracy based upon a coastline detection algorithm

Measurements from the Earth Radiation Budget Experiment (ERBE) scanning radiometers must be accurately located at the top of the Earth's atmosphere for proper interpretation of derived longwave and shortwave components of the Earth radiation field. The accuracy of the location calculations is affected by the orbit characteristics and attitude control systems of the three spacecraft, ERBS, NOAA-9, and NOAA-10. A technique was developed which makes use of the longwave scanner measurements to detect the thermal gradients at the boundaries of ocean and land masses. By analyzing many such coastline boundaries, estimates of the overall accuracy of the scanner measurement location calculations have been derived for the three satellites. The resulting measurement location errors are found to be smaller than the resolution of the radiometers, and this accuracy is well within the required location knowledge for useful science analysis of the ERBE scanner data.

Weaver, William L.↗

Determination of GPS orbits to submeter accuracy

Orbits for satellites of the Global Positioning System (GPS) were determined with submeter accuracy. Tests used to assess orbital accuracy include orbit comparisons from independent data sets, orbit prediction, ground baseline determination, and formal errors. One satellite tracked 8 hours each day shows rms error below 1 m even when predicted more than 3 days outside of a 1-week data arc. Differential tracking of the GPS satellites in high Earth orbit provides a powerful relative positioning capability, even when a relatively small continental U.S. fiducial tracking network is used with less than one-third of the full GPS constellation. To demonstrate this capability, baselines of up to 2000 km in North America were also determined with the GPS orbits. The 2000 km baselines show rms daily repeatability of 0.3 to 2 parts in 10 to the 8th power and agree with very long base interferometry (VLBI) solutions at the level of 1.5 parts in 10 to the 8th power. This GPS demonstration provides an opportunity to test different techniques for high-accuracy orbit determination for high Earth orbiters. The best GPS orbit strategies included data arcs of at least 1 week, process noise models for tropospheric fluctuations, estimation of GPS solar pressure coefficients, and combine processing of GPS carrier phase and pseudorange data. For data arc of 2 weeks, constrained process noise models for GPS dynamic parameters significantly improved the situation.

Bertiger, W. I.↗

Geometric accuracy in airborne SAR images

Uncorrected across-track motions of a synthetic aperture radar (SAR) platform can cause both a severe loss of azimuthal positioning accuracy in, and defocusing of, the resultant SAR image. It is shown how the results of an autofocus procedure can be incorporated in the azimuth processing to produce a fully focused image that is geometrically accurate in azimuth. Range positioning accuracy is also discussed, leading to a comprehensive treatment of all aspects of geometric accuracy. The system considered is an X-band SAR.

Blacknell, D.↗

High accuracy solutions of incompressible Navier-Stokes equations

In recent years, high accuracy finite difference approximations were developed for partial differential equations of elliptic type, with particular emphasis on the convection-diffusion equation. These approximations are of compact type, have a local truncation error of fourth order, and allow the use of standard iterative schemes to solve the resulting systems of algebraic equations. These high accuracy approximations are extended to the solution of Navier-Stokes equations. Solutions are obtained for the model problem of driven cavity and are compared with solutions obtained using other approximations and those obtained by other authors. It is discovered that the high order approximations do indeed produce high accuracy solutions and have a potential for use in solving important problems of viscous fluid flows.

Gupta, Murli M.↗

Accuracy analysis of the semi-analytical method for shape sensitivity calculation

The semianalytical method of design sensitivity analysis that is widely used for calculating derivatives of static response with respect to design variables for structures modeled by finite elements is studied. It is shown that the method can have serious accuracy problems for shape design variables in structures modeled by beam, plate, truss, frame, and solid elements. Errors are shown to be associated with an incompatibility of the sensitivity field with the structure. An error index is developed to test the accuracy of the semianalytical method. It characterizes the difference in errors between a general finite-difference method and the semianalytical method. A method for improving the accuracy of the semianalytical method (when possible) is provided. Examples are presented to demonstrate the use of the error index.

Barthelemy, Bruno↗

On the accuracy of shape sensitivity

The calculation of sensitivity of the response of a structure modeled by finite elements to shape variation is known to be subject to numerical difficulties. The accuracy of a given method is typically measured against the yard stick of finite-difference sensitivity calculation. The present paper demonstrates with a simple example that this approach may be flawed because of discretization errors associated with the finite element mesh. Seven methods for calculating sensitivity derivatives are compared for a two-material beam problem with a moving interface. It is found that as the mesh is refined, displacement sensitivity derivatives converge more slowly than the displacements. Six of the methods agree fairly well, but the adjoint variational surface method provides substantially different results. However, the difference is found to reflect convergence from another direction to the same answer rather than reduced accuracy. Additionally, it is observed that small derivatives are particularly prone to accuracy problems.

Haftka, R. T.↗

Accuracies Of Optical Processors For Adaptive Optics

Paper presents analysis of accuracies and requirements concerning accuracies of optical linear-algebra processors (OLAP's) in adaptive-optics imaging systems. Much faster than digital electronic processor and eliminate some residual distortion. Question whether errors introduced by analog processing of OLAP overcome advantage of greater speed. Paper addresses issue by presenting estimate of accuracy required in general OLAP that yields smaller average residual aberration of wave front than digital electronic processor computing at given speed.

Downie, John D.↗

Ionospheric refraction effects on TOPEX orbit determination accuracy using the Tracking and Data Relay Satellite System (TDRSS)

This investigation concerns the effects on Ocean Topography Experiment (TOPEX) spacecraft operational orbit determination of ionospheric refraction error affecting tracking measurements from the Tracking and Data Relay Satellite System (TDRSS). Although tracking error from this source is mitigated by the high frequencies (K-band) used for the space-to-ground links and by the high altitudes for the space-to-space links, these effects are of concern for the relatively high-altitude (1334 kilometers) TOPEX mission. This concern is due to the accuracy required for operational orbit-determination by the Goddard Space Flight Center (GSFC) and to the expectation that solar activity will still be relatively high at TOPEX launch in mid-1992. The ionospheric refraction error on S-band space-to-space links was calculated by a prototype observation-correction algorithm using the Bent model of ionosphere electron densities implemented in the context of the Goddard Trajectory Determination System (GTDS). Orbit determination error was evaluated by comparing parallel TOPEX orbit solutions, applying and omitting the correction, using the same simulated TDRSS tracking observations. The tracking scenarios simulated those planned for the observation phase of the TOPEX mission, with a preponderance of one-way return-link Doppler measurements. The results of the analysis showed most TOPEX operational accuracy requirements to be little affected by space-to-space ionospheric error. The determination of along-track velocity changes after ground-track adjustment maneuvers, however, is significantly affected when compared with the stringent 0.1-millimeter-per-second accuracy requirements, assuming uncoupled premaneuver and postmaneuver orbit determination. Space-to-space ionospheric refraction on the 24-hour postmaneuver arc alone causes 0.2 millimeter-per-second errors in along-track delta-v determination using uncoupled solutions. Coupling the premaneuver and postmaneuver solutions, however, appears likely to reduce this figure substantially. Plans and recommendations for response to these findings are presented.

Radomski, M. S.↗

Improved accuracy for finite element structural analysis via a new integrated force method

A comparative study was carried out to determine the accuracy of finite element analyses based on the stiffness method, a mixed method, and the new integrated force and dual integrated force methods. The numerical results were obtained with the following software: MSC/NASTRAN and ASKA for the stiffness method; an MHOST implementation method for the mixed method; and GIFT for the integrated force methods. The results indicate that on an overall basis, the stiffness and mixed methods present some limitations. The stiffness method generally requires a large number of elements in the model to achieve acceptable accuracy. The MHOST method tends to achieve a higher degree of accuracy for course models than does the stiffness method implemented by MSC/NASTRAN and ASKA. The two integrated force methods, which bestow simultaneous emphasis on stress equilibrium and strain compatibility, yield accurate solutions with fewer elements in a model. The full potential of these new integrated force methods remains largely unexploited, and they hold the promise of spawning new finite element structural analysis tools.

Patnaik, Surya N.↗

Evaluating model accuracy for model-based reasoning

Described here is an approach to automatically assessing the accuracy of various components of a model. In this approach, actual data from the operation of a target system is used to drive statistical measures to evaluate the prediction accuracy of various portions of the model. We describe how these statistical measures of model accuracy can be used in model-based reasoning for monitoring and design. We then describe the application of these techniques to the monitoring and design of the water recovery system of the Environmental Control and Life Support System (ECLSS) of Space Station Freedom.

Chien, Steve↗

Phase noise in pulsed Doppler lidar and limitations on achievable single-shot velocity accuracy

The smaller sampling volumes afforded by Doppler lidars compared to radars allows for spatial resolutions at and below some sheer and turbulence wind structure scale sizes. This has brought new emphasis on achieving the optimum product of wind velocity and range resolutions. Several recent studies have considered the effects of amplitude noise, reduction algorithms, and possible hardware related signal artifacts on obtainable velocity accuracy. We discuss here the limitation on this accuracy resulting from the incoherent nature and finite temporal extent of backscatter from aerosols. For a lidar return from a hard (or slab) target, the phase of the intermediate frequency (IF) signal is random and the total return energy fluctuates from shot to shot due to speckle; however, the offset from the transmitted frequency is determinable with an accuracy subject only to instrumental effects and the signal to noise ratio (SNR), the noise being determined by the LO power in the shot noise limited regime. This is not the case for a return from a media extending over a range on the order of or greater than the spatial extent of the transmitted pulse, such as from atmospheric aerosols. In this case, the phase of the IF signal will exhibit a temporal random walk like behavior. It will be uncorrelated over times greater than the pulse duration as the transmitted pulse samples non-overlapping volumes of scattering centers. Frequency analysis of the IF signal in a window similar to the transmitted pulse envelope will therefore show shot-to-shot frequency deviations on the order of the inverse pulse duration reflecting the random phase rate variations. Like speckle, these deviations arise from the incoherent nature of the scattering process and diminish if the IF signal is averaged over times greater than a single range resolution cell (here the pulse duration). Apart from limiting the high SNR performance of a Doppler lidar, this shot-to-shot variance in velocity estimates has a practical impact on lidar design parameters. In high SNR operation, for example, a lidar's efficiency in obtaining mean wind measurements is determined by its repetition rate and not pulse energy or average power. In addition, this variance puts a practical limit on the shot-to-shot hard target performance required of a lidar.

Mcnicholl, P.↗

Methodology issues concerning the accuracy of kinematic data collection and analysis using the ariel performance analysis system

Kinematics, the study of motion exclusive of the influences of mass and force, is one of the primary methods used for the analysis of human biomechanical systems as well as other types of mechanical systems. The Anthropometry and Biomechanics Laboratory (ABL) in the Crew Interface Analysis section of the Man-Systems Division performs both human body kinematics as well as mechanical system kinematics using the Ariel Performance Analysis System (APAS). The APAS supports both analysis of analog signals (e.g. force plate data collection) as well as digitization and analysis of video data. The current evaluations address several methodology issues concerning the accuracy of the kinematic data collection and analysis used in the ABL. This document describes a series of evaluations performed to gain quantitative data pertaining to position and constant angular velocity movements under several operating conditions. Two-dimensional as well as three-dimensional data collection and analyses were completed in a controlled laboratory environment using typical hardware setups. In addition, an evaluation was performed to evaluate the accuracy impact due to a single axis camera offset. Segment length and positional data exhibited errors within 3 percent when using three-dimensional analysis and yielded errors within 8 percent through two-dimensional analysis (Direct Linear Software). Peak angular velocities displayed errors within 6 percent through three-dimensional analyses and exhibited errors of 12 percent when using two-dimensional analysis (Direct Linear Software). The specific results from this series of evaluations and their impacts on the methodology issues of kinematic data collection and analyses are presented in detail. The accuracy levels observed in these evaluations are also presented.

Wilmington, R. P.↗

The effect of clock, media, and station location errors on Doppler measurement accuracy

Doppler tracking by the Deep Space Network (DSN) is the primary radio metric data type used by navigation to determine the orbit of a spacecraft. The accuracy normally attributed to orbits determined exclusively with Doppler data is about 0.5 microradians in geocentric angle. Recently, the Doppler measurement system has evolved to a high degree of precision primarily because of tracking at X-band frequencies (7.2 to 8.5 GHz). However, the orbit determination system has not been able to fully utilize this improved measurement accuracy because of calibration errors associated with transmission media, the location of tracking stations on the Earth's surface, the orientation of the Earth as an observing platform, and timekeeping. With the introduction of Global Positioning System (GPS) data, it may be possible to remove a significant error associated with the troposphere. In this article, the effect of various calibration errors associated with transmission media, Earth platform parameters, and clocks are examined. With the introduction of GPS calibrations, it is predicted that a Doppler tracking accuracy of 0.05 microradians is achievable.

Miller, J. K.↗