Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Profiling the molecular destruction rates of temperature and humidity as well as the turbulent kinetic energy dissipation in the convective boundary layer

A simultaneous deployment of Doppler, temperature, and water-vapor lidars is able to provide profiles of molecular destruction rates and turbulent kinetic energy (TKE) dissipation in the convective boundary layer (CBL). Horizontal wind profiles and profiles of vertical wind, temperature, and moisture fluctuations are combined, and transversal temporal autocovariance functions (ACFs) are determined for deriving the dissipation and molecular destruction rates. These are fundamental loss terms in the TKE as well as the potential temperature and mixing ratio variance equations. These ACFs are fitted to their theoretical shapes and coefficients in the inertial subrange. Error bars are estimated by a propagation of noise errors. Sophisticated analyses of the ACFs are performed in order to choose the correct range of lags of the fits for fitting their theoretical shapes in the inertial subrange as well as for minimizing systematic errors due to temporal and spatial averaging and micro- and mesoscale circulations. We demonstrate that we achieve very consistent results of the derived profiles of turbulent variables regardless of whether 1 or 10 s time resolutions are used. We also show that the temporal and spatial length scales of the fluctuations in vertical wind, moisture, and potential temperature are similar with a spatial integral scale of ≈160 m at least in the mixed layer (ML). The profiles of the molecular destruction rates show a maximum in the interfacial layer (IL) and reach values of ϵ m ≃ 7 x 10 -4 g 2 kg −2 s −1 for mixing ratio and ϵ θ ≃ 1.6 x 10 -3 K 2 s −1 for potential temperature. In contrast, the maximum of the TKE dissipation is reached in the ML and amounts to ≃ 10 -2 m 2 s −3 . We also demonstrate that the vertical wind ACF coefficient k w ∝ $\overline{w'^{2}}$ and the TKE dissipation ϵ ∝ ($\overline{w'^{2}}$) 3/2 . For the molecular destruction rates, we show that ϵ m ∝ $\overline{m'^{2}}$ ($\overline{w'^{2}}$) 1/2 and ϵ θ ∝ $\overline{θ'^{2}}$ ($\overline{w'^{2}}$) 1/2 . These equations can be used for parameterizations of ϵ, ϵ m , and ϵ θ . All noise error bars are derived by error propagation and are small enough to compare the results with previous observations and large-eddy simulations. The results agree well with previous observations but show more detailed structures in the IL. Consequently, the synergy resulting from this new combination of active remote sensors enables the profiling of turbulent variables such as integral scales, variances, TKE dissipation, and the molecular destruction rates as well as deriving relationships between them. The results can be used for the parameterization of turbulent variables, TKE budget analyses, and the verification of large-eddy simulations.

dissipation rate↗

Detection and quantification of proppant for optimized fracture treatment design in in-fill and new wells

A system and method for detecting and quantifying proppant for optimized fracture treatment design in in-fill and new wells. Proppant is isolated from drilling fluids and then analyzed to determine whether a formation within the well has been properly stimulated based on the analysis. Placement of an in-fill well may be based upon the determination of whether the well has been properly stimulated.

04 OIL SHALES AND TAR SANDS↗

FECM/NETL Unconventional Shale Well Economic Model (UShWEM): Description and User’s Manual

FECM/NETL Unconventional Shale Well Economic Model (UShWEM) is an Excel-based model that evaluates the economics of an unconventional shale well on a per-well and per-pad basis. This document serves as the user’s manual for the model with descriptions of the procedures the user must follow to run the model. This document also describes the capabilities of the model and provides the equations that are used by the model to calculate technical quantities and key model outputs including net cash flow, internal rate of return (IRR), net present value (NPV), earnings before interest, taxes, depreciation, and amortization (EBITDA), payout month and year, and breakeven price (for either oil- or gas-wells).

Sheriff, Alana↗

FECM/NETL Unconventional Shale Well Economic Model (UShWEM): Production Data for UShWEM

The Production Data for UShWEM.xlsx is an Excel file that is formatted and organized similarly to the Production Streams sheet of the FECM/NETL Unconventional Shale Well Economic Model (UShWEM). The purpose of this file is to allow the user to import completion design and time-series production data for hundreds of wells into the UShWEM easily and quickly, and have their well data saved safely in an external location. For instructions on how to use the Production Data for UShWEM.xlsx file, see section 2.3 of the FECM/NETL Unconventional Shale Well Economic Model: User’s Manual.

Sheriff, Alana↗

Optimizing Rate of Penetration and Tripping Decision-Making using Real-Time Bit Wear Monitoring While Drilling Geothermal Wells

Understanding bit wear while drilling is critical to minimizing non-productive time (NPT) and optimizing rate of penetration (ROP). Lengthening drilling runs with damaged bits does not only lower the ROP, but also elevates the risk of inducing severe bit damage, which could potentially lead to time-consuming fishing operations. When drillers believe the bit has worn off substantially, the bit is tripped out to be replaced. On geothermal wells, tripping can take up to 20% of the overall well construction time, and this is generally acknowledged as an opportunity for improvement. Ideally, a bit run should be terminated before the bit is damaged beyond repair. At the same time, premature bit pulls are to be avoided as well. This study aims to leverage bit and tooth wear metrics that can be obtained in real time to characterize bit condition in order to optimize ROP and determine the optimal time to pull the bit. Two metrics were explored in this study: a bit wear metric that incorporated depth-of-cut, and a tooth wear metric developed by Bourgoyne & Young characterizing the state of bit teeth dull. Both metrics were computed using recorded data from 12¼ inches roller cone insert bit runs in five geothermal wells targeting a granodiorite formation in the western United States. Together with the actual dull grades, determined after the bits were pulled to surface, the metric trends were interpreted to characterize the downhole bit condition and identify the point at which the bit should have optimally been tripped out. The insights from studying the actual dull grades and how they relate to the two metrics were used to establish a reliable bit pull criterion. The bit wear metric trend correctly showed a noticeable departure from baseline for bits experiencing major dulling behavior. Additionally, the tooth wear model predicted the cutter dull within two dull grades for most runs, with better performance in predicting the inner teeth dull. Moreover, the combination of the bit wear and tooth wear metrics was effective in revealing the cause of the bit performance impairment. Proactive tracking of these two metrics in real-time can facilitate geothermal drilling ROP optimization and better-informed tripping decision-making, thereby avoiding wasted time and cost.

Ashari, Rahmat↗

"Hybrid fracture/matrix modeling for well completion options evaluation"

Orientation and completion for well pairs that have been subjected to multi-zonal stimulation play a critical role in the long-term performance of an Enhanced Geothermal Reservoir. Here we present the development of a methodology to rapidly and efficiently numerically simulate mixed fracture-matrix flow systems for evaluation of well design and completion options. The methodology is based on a loose coupling framework, allowing the fracture and matrix systems to be meshed separately. The fracture system includes the integration of fracture growth and aperture data from well stimulation simulations of stochastically generated fracture networks. Automatic mesh refinement is used in the matrix simulation to resolve heat transfer near the fracture network. This simulation framework is used to efficiently determine optimal production and injection well placement using adaptive sampling.

15 GEOTHERMAL ENERGY↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Distributed Fiber Optic Sensing for in-well hydraulic fracture monitoring

This study presents the results from in-well hydraulic fracture monitoring within a horizontal well in an unconventional reservoir utilizing Distributed Fiber Optic Sensing (DFOS). An in-house-developed Brillouin-based Distributed Strain Sensing (DSS) interrogator was deployed to obtain strain measurements, complemented by a commercial Raman-based Distributed Temperature Sensing (DTS) interrogator for temperature measurements and a commercial Rayleigh-based Low-Frequency Distributed Acoustic Sensing (LF-DAS) interrogator for strain-rate measurements. Examined over a ten-day period, the spatio-temporal distribution of temperature-compensated strain obtained from DSS and DTS revealed distinct signatures of the multi-stage hydraulic fracturing process. These signatures were analyzed with respect to fracture width growth and closure, residual strain effects, and fracture conductivity near the wellbore. Fracture widths within the fracture zone were estimated for individual stages. The findings were assessed with LF-DAS measurements for further evaluation. This work integrates DFOS-measured strain, temperature, and strain-rate data for monitoring in-well hydraulic fracturing, with the goal of supporting future studies in interpreting DFOS measurements for improved understanding of hydraulic fracturing in unconventional reservoirs.

58 GEOSCIENCES↗

Dynamic Life Cycle Assessment for Evaluating the Global Warming Potential of Geothermal Energy Production Using Inactive Oil and Gas Wells for District Heating in Tuttle, Oklahoma

Repurposing abandoned oil and gas infrastructure for geothermal energy production has great potential to reduce greenhouse gas (GHG) emissions. This study quantified the life cycle global warming potential of geothermal energy production using four inactive oil and gas wells repurposed for district heating in Tuttle, Oklahoma. A cradle-to-grave prospective life cycle assessment was performed to compare GHG emissions between the geothermal district heating system and conventional natural gas-fired heating system from 2020 to 2050. For initial implementation of the geothermal system, we investigated two approaches: 1) repurposing abandoned infrastructure from a nearby oil and gas well site, and 2) production and injection well drillings including new construction of a central heat exchange station. Environmental impacts from the geothermal system were estimated for five scenarios where a natural gas peaking boiler is incorporated to supply peak heat demand. The prospective results indicated that cumulative reduction in GHG emissions from transitioning to the geothermal district heating system increase over time as a function of future renewable resource penetration and technological advancements within electricity, fuel, and steel production. Over 30 years, the global warming potential associated with the district heating demand will have been reduced by up to 24 % with the repurposed system. These results imply that repurposing existing oil and gas infrastructure for geothermal energy systems of district heating will bring future climate benefits.

abandoned oil and gas wells↗

Efficiency and Forward Voltage of Blue and Green Lateral LEDs with V-shaped Defects and Random Alloy Fluctuation in Quantum Wells

For nitride-based blue and green light-emitting diodes (LEDs), the forward voltage V for is larger than expected, especially for green LEDs. This is mainly due to the large barriers to vertical carrier transport caused by the total polarization discontinuity at multiple quantum well and quantum barrier interfaces. The natural random alloy fluctuation in quantum wells has proven to be an important factor reducing V for . However, this does not suffice in the case of green LEDs because of their larger polarization-induced barrier. V-shaped defects (V-defects) have been proposed as another key factor in reducing V for to allow lateral injection into multiple quantum wells, thus bypassing the multiple energy barriers incurred by vertical transport. In this paper, to model carrier transport in the whole LED, we consider both random-alloy and V-defect effects. A fully two-dimensional drift-diffusion charge-control solver is used to model both effects. The results indicate that the turn-on voltages for blue and green LEDs are both affected by random alloy fluctuations and the V-defect density. For green LEDs, V for decreases more due to V-defects, where the smaller polarization barrier at the V-defect sidewall is the major path for lateral carrier injection. Then, we discuss how the V-defect density and size affects the results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utah FORGE Well 16A(78)-32 Simplified Discrete Fracture Network Data

The FORGE team is making these fracture models available to researchers wanting a set of natural fractures in the FORGE reservoir for use in their own modeling work. They have been used to predict stimulation distances during hydraulic stimulation at the open toe section of well 16A(78)-32. This is a simplified DFN (discrete fracture network) dataset, that was generated using FracMan, for Utah FORGE well 16A(78)-32. A short, well-illustrated, report describing the data is also included in the provided archive file.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Coordinates of wells at San Emidio, Nevada

This dataset includes position coordinates and elevation information for wells at the WHOLESCALE San Emidio project location. Well positions in the attached file are characterized by UTM coordinates (Easting, Northing) in meters, and WHOLESCALE coordinates (Easting, Northing) relative in meters from a chosen reference point. The elevation of the top and bottom of open intervals within each well (representing locations of perforated or open-hole sections) are measured in meters (positive) above WGS84 geoid (mean sea level). The WHOLESCALE acronym stands for Water & Hole Observations Leverage Effective Stress Calculations and Lessen Expenses. The goal of the WHOLESCALE project is to simulate the spatial distribution and temporal evolution of stress in the geothermal system at San Emidio in Nevada, United States.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Microseismic Surface Network Catalogs for Wells 16A(78)-32 and 16B(78)-32 Stimulation 2022 and Circulation 2023

This dataset includes microseismic surface network catalogs for Utah FORGE. Data were recorded during the stimulation of well 16A(78)-32 in 2022 and the circulation tests between wells 16A(78)-32 and 16B(78)-32 in 2023. Near-surface seismic monitoring during circulation experiments in wells 16A(78)-32 and 16B(78)-32 revealed fracture growth after shut-in. The catalog provided here offers a comprehensive list of microseismic events, including details on their spatial and temporal distribution, magnitude, and clustering behavior.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Updated FMI Fracture Log from Well 16A(78)-32

This dataset consists of an Excel spreadsheet detailing the fracture picks from a reinterpretation of the formation micro-imaging (FMI) log from Utah FORGE well 16A(78)-32. The provided information details fracture location, geometry, and type. Also included here is a link to the original raw and processed FMI logs, as well as other data from the 2021 well logging.

15 GEOTHERMAL ENERGY↗

Optimizing Alabama’s CO 2 Storage in Shelby County (Project OASIS) Milestone 3.4 Report: Complete Well Design and Drilling Plan

We are pleased to present the following materials, which serve as confirmation of the successful completion of Task 3.4 Complete Well Design and Drilling Plan Milestone, in accordance with the Project OASIS Project Management Plan. More specifically, the following provides confirmation of a team-wide call that was held on September 25, 2023, to discuss the CarbonSAFE Phase II drilling program, the well drilling prognosis, and an overview of risks associated with the program by category as well as probability and impact. A comprehensive Site-Specific Drilling Report will be provided to DOE-NETL 30 days after completion of drilling activities.

20 FOSSIL-FUELED POWER PLANTS↗

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE: Well 16A(78)-32 Logs

This dataset contains all well logs from Utah FORGE well 16A(78)-32. This includes the mud log, Sanvean Technologies logs, and Schlumberger logs. Please see the file descriptions below for information about each log.

15 GEOTHERMAL ENERGY↗