Methods for Finding Legacy Wells in Large Areas

United States. When abandoned, many wells were not adequately sealed and now provide a potential conduit for the vertical movement of liquids and gases. Today, groundwater aquifers can be contaminated by surface pollutants flowing down wells or by deep, saline water diffusing upwards. Likewise, natural gas, carbon dioxide (CO2), or radon can travel upwards via these wells to endanger structures or human health on the surface. Recently, the need to find and plug wells has become critical with the advent of carbon dioxide injection into geologic formations for enhanced oil recovery (EOR) or carbon storage. The potential for natural gas or brine leakage through existing wells has also been raised as a concern in regions where shale resources are hydraulically fractured for hydrocarbon recovery. In this study, the National Energy Technology Laboratory (NETL) updated existing, effective well finding techniques to be able to survey large areas quickly using helicopter or ground-vehicle-mounted magnetometers, combined with mobile methane detection. For this study, magnetic data were collected using airborne and ground vehicles equipped with two boom-mounted magnetometers, or on foot using a hand-held magnetometer with a single sensor. Data processing techniques were employed to accentuate well-casing-type magnetic signatures. To locate wells with no magnetic signature (wells where the steel well casing had been removed), the team monitored for anomalous concentrations of methane, which could indicate migration of volatile compounds from deeper sedimentary strata along a well or fracture pathway. Methane measurements were obtained using the ALPIS DIfferential Absorption Lidar (DIAL) sensor for helicopter surveys and the Apogee leak detection system (LDS) for ground surveys. These methods were evaluated at a 100-year-old oilfield in Wyoming, where a helicopter magnetic survey accurately located 93% of visible wells. In addition, 20% of the wells found by the survey were previously unknown or inaccurately located. This study found helicopter magnetic surveys to be an accurate, cost- and time-effective means to locate steel-cased wells in large areas, and is a first step in evaluating whether well detection techniques can be applied effectively for well location screening across broad geographic areas.

54 ENVIRONMENTAL SCIENCES↗

Y-12 Groundwater Protection Program Monitoring Well Inspection and Maintenance Plan

This plan describes the systematic approach for: inspecting the physical condition of monitoring wells at Y-12, determining maintenance needs that extend the life of a well, and identifying those wells that no longer meet acceptable monitoring well design or well construction standards and require plugging and abandonment. The inspection and maintenance of groundwater monitoring wells is one of the primary management strategies of the Y-12 Groundwater Protection Program (GWPP) Management Plan, that is, the “proactive stewardship of the extensive monitoring well network at Y-12" (Consolidated Nuclear Security, L.L.C. [CNS], 2018). Effective stewardship, and a program of routine inspections of the physical condition of each monitoring well, ensures that representative water-quality samples and hydrologic data are obtained from the well network and protects the subsurface environment. In accordance with the Y-12 GWPP Monitoring Optimization Plan (MOP) for Groundwater Monitoring Wells at the Y-12 National Security Complex, Oak Ridge, Tennessee (CNS, 2017), the status designation (active or inactive) for each well determines the scope and extent of well inspections and maintenance activities. This plan, in conjunction with the above document, formalizes the GWPP approach to focus available resources on monitoring wells which provide the most useful data, and for that reason the GWPP inspects and performs maintenance on the wells sampled by the GWPP. This plan applies to groundwater monitoring wells installed at Y-12 and the related waste management facilities located within the three hydrogeologic regimes: (1) the Bear Creek Hydrogeologic Regime (Bear Creek Regime), (2) the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and (3) the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek Regime encompasses the section of Bear Creek Valley (BCV) immediately west of Y-12. The East Fork Regime encompasses most of the Y-12 process, operations, and support facilities in BCV west of Scarboro Road. The Chestnut Ridge Regime is directly south of Y-12 and encompasses a section of Chestnut Ridge that is bounded to the west by a surface drainage feature (Dunaway Branch, located immediately west of Industrial Landfill II) and by Scarboro Road to the east. The GWPP maintains an extensive database of geographic and construction details and related information for the monitoring wells in each hydrogeologic regime in the Updated Subsurface Database for Bear Creek Valley, Chestnut Ridge, and Parts of Bethel Valley on the U.S. DOE Oak Ridge Reservation (CNS, 2019). A detailed description of the hydrogeologic framework at Y-12 can be found in the GWPP Management Plan (CNS, 2018).

54 ENVIRONMENTAL SCIENCES↗

Gaining Perspective on Unconventional Well Design Choices through Play-level Application of Machine Learning Modeling

The recent development of unconventional oil and gas (O&G) reservoirs has led to an abundant hydrocarbon supply, both domestically and globally. However, there is a continued push to develop new and innovative approaches to improve exploration and extraction efficiencies and overall well productivity moving forward. Substantial improvements in unconventional O&G development are expected through optimized well completion and stimulation strategies aimed at maximizing well productivity. Optimizing well designs will require tailoring to the distinctive geologic conditions present for any newly placed well. To better evaluate the impact of well design attributes and their associated interactions on productivity in a major unconventional play, multivariate machine learning-based models that use empirical datasets were developed. A gradient boosted regression tree (GBRT) algorithm was applied. GBRT has been narrowly investigated for O&G applications but enables straightforward parametric importance and influence evaluation, as well as assessment of parameter interaction effects. Models were trained on well design and locational parameters that serve as a proxy for variable geologic conditions to estimate two types of productivity indicator response variables strongly correlated to estimated ultimate recovery (EUR). The dataset utilized consists of over 7,000 well observations that cover the majority of the productive region of the Marcellus Shale. Model performance was evaluated and algorithm parameters tuned by analyzing the goodness-of-fit for simulated results against observed data in a cross-validation approach. Models were found capable of 73–79 percent prediction accuracy on held out testing data of gas equivalent production and can be used to inform future well design and placement decisions for increasing EUR per well and improving overall field-level recovery. Study results indicate that Marcellus well performance improves most with upscaling perforated interval lengths and water and proppant volumes per foot; but relative productivity improvements are spatially dependent across the play. Finally, optimal combinations of water and proppant on well performance were found to vary depending on well location, emphasizing the utility of data-driven models capable of broad application across a play of interest for informing tailored well design approaches prior to their field deployment.

04 OIL SHALES AND TAR SANDS↗

Risk matrix for legacy wells within the Area of Review (AoR) of Carbon Capture & Storage (CCS) projects

The success of CCS depends on the capacity, injectivity, and confinement by the storage medium. Thousands of wells drilled over the past century with the intention to find the trapped oil and gas may penetrate the containment seals. These wells may provide leakage pathways for the CO 2 to escape and contaminate the underground sources of drinking water (USDW) or reach the surface in the worst-case scenario. Identifying the risky wells penetrating the containment seals and predicting their current as well as future well integrity is the most challenging task when limited data is available. Here, this paper proposes a unique methodology for risk assessment of the wells penetrating the containment seals based on the proximity of these wells from the proposed injection location, mechanical integrity, and accessibility of these wells over the lifecycle of the CCS project. This helps in identifying the wells which need immediate attention from the wells that need little to no attention. It also highlights the corrective actions necessary for the success of the CCS project as well as help estimate the approximate cost required to perform the corrective actions. This methodology focuses on all wells (producers, injectors, orphan, abandoned, water, stratigraphic, etc) while the majority of the studies found in literature focused on wells with sustained casing pressure (SCP) reports and cement bond logs (CBL). The proposed risk matrix, if applied to future CCS projects across the globe, will uniformly categorize the wells within the Area of Review (AoR).

58 GEOSCIENCES↗

Single–Well Injection–Drift Test to Estimate Groundwater Velocity

A simple algebraic equation is presented here to estimate the magnitude of groundwater velocity based on data from a single-well injection-drift test thereby eliminating the time-consuming and costly extraction phase. A volume of tracer-amended water was injected by forced-gradient into a single well followed by monitoring of the conservative solute tracers under natural-gradient conditions as their upgradient portions drifted back through the well. The breakthrough curve data from the single well during the drift phase was analyzed to determine the mean travel times of the tracers. The estimated mean upgradient travel distance back through the single well and the mean travel times of the tracers were used in a simple algebraic equation to estimate groundwater velocity. The groundwater velocity based on the single-well injection-drift test was estimated to be approximately 0.64 ft per day. Two transects of observation wells were used to monitor the natural-gradient tracer transport downgradient of the injection well. The one-dimensional, or dual-well, transport of the tracer from the injection well to the nearest downgradient observation well indicated that the groundwater velocity was 0.55 ft per day. The two-dimensional, or multi-well, transport of the center of mass of the tracers indicated that the groundwater velocity was 0.60 ft per day; the dual- and multi-well results were in excellent agreement with those from the single-well and validated the simple algebraic equation. In conclusion, the new single-well method presented here is relatively simple, rapid, and does not require an extraction phase.

54 ENVIRONMENTAL SCIENCES↗

California GAMA Special Study: An isotopic and dissolved gas investigation of nitrate source and transport to a public supply well in California's Central Valley

This study investigates nitrate contamination of a deep municipal drinking water production well in Ripon, CA to demonstrate the utility of natural groundwater tracers in constraining the sources and transport of nitrate to deep aquifers in the Central Valley. The goal of the study was to investigate the origin (source) of elevated nitrate and the potential for the deep aquifer to attenuate anthropogenic nitrate. The site is ideal for such an investigation. The production well is screened from 165-325 feet below ground surface and a number of nearby shallow and deep monitoring wells were available for sampling. Furthermore, potential sources of nitrate contamination to the well had been identified, including a fertilizer supply plant located approximately 1000 feet to the east and local almond groves. A variety of natural isotopic and dissolved gas tracers including {sup 3}H-{sup 3}He groundwater age and the isotopic composition of nitrate are applied to identify nitrate sources and to characterize nitrate transport. An advanced method for sampling production wells is employed to help identify contaminant contributions from specific screen intervals. Nitrate transport: Groundwater nitrate at this field site is not being actively denitrified. Groundwater parameters indicate oxic conditions, the dissolved gas data shows no evidence for excess nitrogen as the result of denitrification, and nitrate-N and -O isotope compositions do not display patterns typical of denitrification. Contaminant nitrate source: The ambient nitrate concentration in shallow groundwater at the Ripon site ({approx}12 mg/L as nitrate) is typical of shallow groundwaters affected by recharge from agricultural and urban areas. Nitrate concentrations in Ripon City Well 12 (50-58 mg/L as nitrate) are significantly higher than these ambient concentrations, indicating an additional source of anthropogenic nitrate is affecting groundwater in the capture zone of this municipal drinking water well. This study provides two new pieces of evidence that the Ripon Farm Services Plant is the source of elevated nitrate in Ripon City Well 12. (1) Chemical mass balance calculations using nitrate concentration, nitrate isotopic composition, and initial tritium activity all indicate that that the source water for elevated nitrate to Ripon City Well 12 is a very small component of the water produced by City Well 12 and thus must have extremely high nitrate concentration. The high source water nitrate concentration ({approx}1500 mg/L as nitrate) required by these mass balance calculations precludes common sources of nitrate such as irrigated agriculture, dairy wastewater, and septic discharge. Shallow groundwater under the Ripon Farm Services RFS plant does contain extremely high concentrations of nitrate (>1700 mg/L as nitrate). (2) Nitrogen and oxygen isotope compositions of nitrate indicate that the additional anthropogenic nitrate source to Ripon City Well 12 is significantly enriched in {delta}{sup 18}O-NO{sub 3}, an isotopic signature consistent with synthetic nitrate fertilizer, and not with human or animal wastewater discharge (i.e. dairy operations, septic system discharge, or municipal wastewater discharge), or with organic fertilizer. Monitoring wells on and near the RFS plant also have high {delta}{sup 18}O-NO{sub 3}, and the plant has handled and stored synthetic nitrate fertilizer that will have this isotopic signature. The results described here highlight the complexity of attributing nitrate found in long screened, high capacity wells to specific sources. In this case, the presence of a very high concentration source near the well site combined with sampling using multiple isotopic tracer techniques and specialized depth-specific techniques allowed fingerprinting of the source in the mixed-age samples drawn from the production well.

54 ENVIRONMENTAL SCIENCES↗

COMPARISON OF VENTED AND ABSOLUTE PRESSURE TRANSDUCERS FOR WATER-LEVEL MONITORING IN HANFORD SITE CENTRAL PLATEAU WELLS

Automated water-level data collected using vented pressure transducers deployed in Hanford Site Central Plateau wells commonly display more variability than manual tape measurements in response to barometric pressure fluctuations. To explain this difference, it was hypothesized that vented pressure transducers installed in some wells are subject to barometric pressure effects that reduce water-level measurement accuracy. Vented pressure transducers use a vent tube, which is open to the atmosphere at land surface, to supply air pressure to the transducer housing for barometric compensation so the transducer measurements will represent only the water pressure. When using vented transducers, the assumption is made that the air pressure between land surface and the well bore is in equilibrium. By comparison, absolute pressure transducers directly measure the air pressure within the wellbore. Barometric compensation is achieved by subtracting the well bore air pressure measurement from the total pressure measured by a second transducer submerged in the water. Thus, no assumption of air pressure equilibrium is needed. In this study, water-level measurements were collected from the same Central Plateau wells using both vented and absolute pressure transducers to evaluate the different methods of barometric compensation. Manual tape measurements were also collected to evaluate the transducers. Measurements collected during this study demonstrated that the vented pressure transducers over-responded to barometric pressure fluctuations due to a pressure disequilibrium between the air within the wellbores and the atmosphere at land surface. The disequilibrium is thought to be caused by the relatively long time required for barometric pressure changes to equilibrate between land surface and the deep vadose zone and may be exacerbated by the restriction of air flow between the well bore and the atmosphere due to the presence of sample pump landing plates and well caps. The disequilibrium is likely limited to wells screened across the water table (i.e., open to the deep vadose zone) where the depth to water is large or a low-permeability layer occurs in the vadose zone. Such wells are a pathway for air movement between the deep vadose zone and land surface and this sustains the pressure disequilibrium between the well bore and the atmosphere for longer time periods. Barometric over-response was not observed with the absolute pressure transducers because barometric compensation was achieved by directly measuring the air pressure within the well. Users of vented pressure transducers should be aware of the over-response issue in certain Hanford Site wells and ascertain if it will affect the use of the data. Pressure disequilibrium between the well and the atmosphere can be identified by substantial air movement through the wellbore. In wells exhibiting pressure disequilibrium, it is recommended that absolute pressure transducers be used rather than vented transducers for applications that require precise automated determinations of well water-level changes in response to barometric pressure fluctuations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Predicting future well performance for environmental remediation design using deep learning

Here in this study, we developed a deep learning (DL) framework with a multi-channel three-dimensional convolutional neural network (MC3D-CNN) to predict well performance and thereby assist future environmental remediation design. Such prediction of extraction well performance at designated locations is critical for configuring pump-and-treat (P&T) well network design and operation, setting reasonable target closure dates for overall remedying, and estimating remedy costs. The framework is developed with operational and monitoring data routinely collected during P&T remedy operations, including well extraction and injection rates as well as in situ contaminant concentrations. Traditionally, the collected data were rarely used for purposes other than assessing past well performance and the accuracy of the conceptual site model. However, recent advances in data-driven computational approaches enable better use of the large datasets to inform future well performance, enhance site characterization, and improve remediation planning. In this study, we established a DL framework to integrate transient three-dimensional contaminant plumes and multiple aquifer properties (e.g., hydraulic conductivity and hydrostratigraphic maps) to identify characteristic patterns controlling and representing extraction well mass recovery, aiming at providing future mass recovery estimates for existing wells and candidate wells at any proposed locations. We evaluated our framework by using a realistic synthetic dataset generated from a well-calibrated flow and transport model used in the 200 West Area of the U.S. Department of Energy’s Hanford Site in southeastern Washington state. The multi-channel feature in our framework allows integration of various types and temporal densities of training datasets for DL model development. Overall, we found that the trained DL model achieved an accuracy of over 90% in ranking extraction well performance in validation datasets, and over 80% in predicting high-performance-ranking well locations. This data-informed approach provides a flexible tool to support adaptive site management, streamline decision-making, and potentially reduce remediation time and costs. Our DL framework can be used as a filtering tool to improve the current P&T network optimization design by reducing the number of candidate well locations.

54 ENVIRONMENTAL SCIENCES↗

WELLS Database

The Wellbore Exploration and Location Logistic System (WELLS) is a living national wellbore database - created and maintained by the National Energy Technology Laboratory (NETL). This resource contains more than seven million public wellbore records from state, federal, and tribal resources. Sourced from over 65 authoritative, yet disparate resources, the WELLS Database combines and synthesizes well data from oil, gas, underground injection, research, geothermal, geotechnical, groundwater and other types of wells in a single, unified system. This resource can be explored and visualized through the WELLS Interactive Application, also on EDX: https://edx.netl.doe.gov/dataset/wells-interactive-application The WELLS Database (formerly titled CO2-Locate) is an integrated national well dataset, representing open-source wellbore data from disparate state, tribal, and federal entities. The database provides publicly available well header data with key attributes such as well age, depth, and status. The database contains a fully integrated CSV file with all values in numerical columns, such as depth, converted into numbers. This version has a NETL derived API (American Petroleum Institute) number column and has been handled for redundancies, resulting in one record for every unique API number. The database also contains a fully integrated CSV file, where all original data are kept as text values. Additionally, the database includes a shapefile containing key attributes and coordinates from the integrated dataset, reformatted public wells CSV files, and a proprietary well density grid shapefile. Notes for consideration: The WELLS Database will be updated periodically with new datasets and information. A field dictionary with field (i.e., attribute) coverage across acquired public well resources, and the resulting integrated public well datasets are available in the spreadsheet, WELLS_Field_Dictionary.xlsx. Summary layers provided in this database are derived from proprietary layers and do not always contain key features (status, type, true vertical depth, or spud year) and therefore might not be shown when data are queried for those features.

AS↗

Success Using A Granular-Activated Carbon Filtration Swab to Rehabilitate Westbay{sup R} Multi-level Groundwater Monitoring Wells at the INL - 20544

In November 2015, tetrachloroethylene (PCE) was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was instead due to inadvertent contamination of the internal tubing fluid in the Westbay well-monitoring system, which is isolated from the surrounding groundwater. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency's maximum contaminant level for drinking water (5 μg/L). Loose sediment at the bottom of some Westbay wells was also found to contain PCE; the three wells were then identified for rehabilitation as part of the INL well maintenance program. The unique construction of the Westbay wells - i.e., the small diameter (5.72 cm [2.25 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface - posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, custom-fabricated, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Westbay well rehabilitation started at well MIDDLE-2051 in late June 2018 and paused in December 2018 for the season. The PCE concentration in the tubing fluid at MIDDLE-2051 was initially reduced to a maximum concentration of 3.81 μg/L from a maximum of 642 μg/L, while the concentration of PCE in the sediment had been reduced from 5,360 to 2,270 μg/kg. Sampling was performed at MIDDLE-2051 again in August 2019, and the tubing fluid increased to a maximum concentration of 45.4 μg/L, while the concentration in the sediment decreased further to 1,890 μg/kg due to desorption of PCE from the sediment to the tubing fluid. Rehabilitation resumed at well MIDDLE-2050A in late August 2019, and the PCE concentration in the tubing fluid had been reduced to a maximum concentration of 19.0 μg/L. Although the method has been shown to be time-consuming, it has proven to be effective and safe for personnel performing the work and to the integrity of the well. Future sample data results at all wells will help determine an estimated completion of the rehabilitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Tritium Activities in Bailed versus Pumped Samples from Wells at the Nevada National Security Site

The Underground Test Area (UGTA) Activity uses a variety of methods to collect groundwater samples to identify radionuclide migration from underground nuclear tests. These include depth-discrete bailing, pumping with low-volume rod pumps, and pumping with electrical submersible pumps. The Nevada National Security Site (NNSS) Integrated Groundwater Sampling Plan specifies that when sampling with a pump, a minimum of three effective well volumes are withdrawn and then samples are collected after water-quality parameters have stabilized. In locations where pumping is not feasible, depth-discrete bailing is used and purging prior to sampling is usually not required. A recent study evaluated three sampling technologies and recommended that historical tritium results be evaluated where both pumped and bailed samples are available to identify preferred sampling protocols for the collection of tritium samples. The tritium ( 3 H) activities were obtained from the UGTA chemistry data base. Wells were identified with known 3 H activities above method detection limits, and then evaluated if both bailed and pumped samples had been collected. Twenty two wells and piezometers with bailed samples, pumped samples, and 3 H activities above background were identified for further consideration. The conclusions from this analysis are: Bailed samples collected for 3 H analysis near the water surface in a well are lower in 3 H activity than bailed samples from within screened intervals and pumped samples. Depth-discrete bailed samples from within the screened intervals are generally in good agreement with pumped samples from developed wells and piezometers. Depth-discrete bailed samples from undeveloped wells and piezometers are in good agreement with the first pumped samples. However, the next pumped samples increased in 3 H activity, resulting in a greater percent difference between the undeveloped bailed samples and later pumped samples. Continuous pumping over extended periods removing large purge volumes from wells can perturbate the surrounding groundwater system for long periods of time. These perturbations can cause large changes in 3 H activities in the aquifer near the well because of the mixing of groundwater with variable 3 H activities. Recommendations include: Bailed samples for 3 H should not be collected near the water surface in the well. Bailed samples should be collected from within the well screen. Logs of temperature, chemistry, and thermal flow should be evaluated to identify optimal depths within the well screen to collect depth-discrete bailer samples. Purging of large volumes of water from the well over extended periods of time should be avoided when collecting 3 H samples. Sufficient time should be allowed after pumping large volumes of water from the well (e.g., after well development) for the surrounding aquifer and 3 H activities to return to ambient conditions

54 ENVIRONMENTAL SCIENCES↗

Well Stimulation Treatment in California: Evaluation of Disclosure Data, May 2015 – October 2019

In this document, disclosure data from 1,228 well stimulations occurring May 2015 to October 2019 in California are evaluated. This evaluation updates a previous study that was based on 618 well stimulations occurring May 2015 to June 2016 (Stringfellow, W.T., Camarillo, M.K., and Jordan, P. 2017, Status of Well Stimulation in California Since Implementation of SB-4 Regulations, Berkeley National Laboratory, Berkeley, CA). While the goal of the previous study was to provide a summary of information obtained since passage of California Senate Bill No. 4—Oil and Gas, the goal of the current evaluation is to provide a basis for studying chemical indicators that could potentially be used to detect aquifer contamination. We evaluate chemical indicators is a separate document using the data contained herein as well as data from monitoring wells located within oil fields. Compared with the data used by Stringfellow et al. 2017, the current evaluation is based on a more diverse data set. While the previous study contained data for only two oil fields with more than 30 well stimulations, the current data set contains four oil fields with more than 30 well stimulations, making these data more ideal for comparisons using statistical tests. More producers and a new oil field, Buena Vista Nose, are represented in the current data set. Some well stimulation practices remain relatively unchanged since the previous study. Well stimulation is mostly occurring in Kern County with the exception of a single well stimulation in Orange County. Almost all well stimulations are hydraulic fracturing. The current data set contains two acid fracturing treatments and one matrix acidizing treatment. The median number of chemicals added per well stimulation—excluding water and proppant—was previously 21; the number in the expanded data set is 20. Median water added per well stimulation was previously 89,000 gallons and is now 98,000 gallons. While this water use represents a 10% increase, water use for hydraulic fracturing in California is still lower than water use in other oil and gas fields. Chemical formulations appear to have shifted since the previous study. This shift may be related to a change in the predominant service company. We identified 26 chemicals for which the frequency of use has changed by more than 30%. The total number of chemicals used has also expanded. Previously, 178 unique chemicals were identified as being added to well stimulation fluids. The total number of unique chemicals is now 205. Analytical data available for base and recovered fluids has expanded. The number of base fluid samples has increased from 12 to 35 and the number of recovered fluid samples has increased from 1,078 to 2,166. The expanded data set is more ideal for an evaluation of indicator chemicals and comparisons across different formations. The analytical data for recovered fluid samples indicates that many ions, radioactive constituents, and organics are consistently observed, making these chemicals ideal for consideration as potential indicators of aquifer contamination.

54 ENVIRONMENTAL SCIENCES↗

Basic Data Report for Monitor Well AEC-7 (C-2742) Reconfiguration Activities

The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy (DOE) facility disposing of transuranic and mixed waste under the Hazardous Waste Facility Permit (Permit NM4890139088-TSDF, as amended) issued by the New Mexico Environment Department (NMED). WIPP is located approximately 26 miles east of Carlsbad, New Mexico, in eastern Eddy County (Figure 1-1). Disposal panels are being excavated in the Permian Salado Formation at a depth of approximately 2,150 feet below ground surface (bgs). Over the years a number of groundwater monitor wells have been installed for site characterization and to monitor temporal and spatial changes in groundwater elevation and chemistry at WIPP. Many of the wells used for this purpose were constructed of carbon steel casing that has deteriorated to varying degrees due to corrosion. For some wells, the deterioration has led to failure of the well integrity. In such cases, the well must either be reconfigured or completely plugged, according to regulatory requirements, to prevent commingling of groundwater from different formations. Other wells are nearing the end of their useful life and/or are duplicative of other wells that serve the same purpose. Because of these integrity issues, WIPP has begun a program to plug and abandon wells that are no longer useful for the monitoring program or are redundant, and to reconfigure other wells for future monitoring. One such well is known as AEC-7, which was reconfigured to monitor only the Culebra Member of the Rustler Formation. The New Mexico Office of the State Engineer (OSE) permitted well AEC-7 as C-2742. This well has been part of the far-field monitoring network since 1974. The well was used to obtain water level levations and hydraulic parameters from both the Bell Canyon Formation and the Culebra Member of the Rustler Formation. This basic data report provides a historical account of the well from the original installation to the current configuration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio – 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were “right-sized” at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented.

54 ENVIRONMENTAL SCIENCES↗

Installing Deep Groundwater Monitoring Wells in a Volcanic Dominated Rift Basin: Los Alamos National Laboratory, New Mexico - 17594

Los Alamos National Laboratory (LANL, or the Laboratory) is located in northern New Mexico near the west margin of the Espanola Basin. LANL is underlain by a complex basin-fill sequence of alluvial fan deposits, volcanic tuff, basaltic and dacitic lavas, and riverine deposits. On-going environmental remediation and characterization activities have evolved to improve the performance of groundwater monitoring wells, ensuring they yield representative groundwater and core samples. Groundwater occurs as canyon-fill alluvial water, perched intermediate-depth water associated with the basalts and other local-scale perching horizons, and as a regional-scale aquifer that is the main water supply for the area. Anthropogenic contaminants are found in all three groundwater zones. The regional aquifer below LANL is nominally 1000-1400 feet below ground surface (bgs). Monitoring wells at the Laboratory, are therefore, among the deepest routinely installed in the US. Logistical challenges at LANL include steep terrain, widespread cultural sites, and threatened and endangered species habitat restrictions. Additionally, the cost of installing monitoring wells is high because of groundwater depths and the variable drilling techniques that are required to characterize and install wells in a complex geologic environment. A major challenge to the characterization approach at LANL has been to meet sample quality requirements while minimizing drilling costs. In the late 1990's threaded drill-casing was advanced by rotary drilling methods using compressed air as the only circulation fluid. This resulted in relatively low impacts to the geochemical integrity of rock and groundwater samples, but led to frequent episodes of stuck casing. Additional fluids were introduced to the air-rotary program, improving penetration rates, but also resulting in non-representative groundwater samples due to long-term impacts to the aquifer in the vicinity of the well screen. Mud-rotary drilling was incorporated into the program, but it also had significant long-term impacts on groundwater quality, and often inhibited identification of perched groundwater zones and accurate identification of the water table in the regional aquifer. Current drilling practice makes limited use of fluid additives (e.g. foam) to supplement air circulation methods in order to advance drill casing through the vadose zone. Starting about 100 feet above the water table, drill casing is advanced to the target horizon in the regional aquifer using only air and municipal water (when needed) for circulation. Additionally, the threaded drill casing couplings have been replaced with welded connections, significantly reducing the occurrence of stuck casing. Careful observations of water production and water levels during drilling, coupled with the ability to retract casing for video and geophysical logs, now allows for robust characterization of perched groundwater systems and accurate definition of the top of regional saturation. Recent advances in the drilling program include combined dual-rotary/sonic drilling to depths up to 1150 feet and dual-rotary casing advance at angles up to 25 deg. from vertical. The former allows for core collection with minimal fluid addition, thereby preserving pore water chemistry. The latter method allows for well installation into portions of the aquifer otherwise inaccessible due to constraints at the surface (e.g., cultural sites or topography). Similar to the development of drilling techniques, both well design and groundwater sampling system design have evolved throughout the program. Current well design emphasizes a minimal annulus of filter pack, maximum screen slot size based on formation sieve analyses, and thorough well development to mitigate formation damage due to drilling. To sample groundwater at multiple levels in the same well, earlier sampling systems included Westbay{sup R} multi-zone systems and dual-screen single-pump and dual-screen dual-pump systems designed in collaboration with Baski, Inc. These multi-zone sampling systems proved difficult to develop and maintain given the depth to groundwater, and most current well installations are configured with a single screen and a submersible pump. The ability to purge from a well-developed single-screen well has substantially improved the collection of representative groundwater samples. A carefully crafted groundwater characterization program in target aquifers at depths ranging from 1,000 to 1,400 feet bgs within a complex geologic setting, while also retaining the ability to collect representative core and groundwater samples, may have application at a number of sites throughout the environmental industry. Optimizing each well to meet program objectives while reducing total project costs benefits all environmental investigations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio - 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were 'right-sized' at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rehabilitation of Westbay{sup R} Wells with PCE-Contaminated Tubing Fluid - 19250

In November 2015, tetrachloroethylene, also known as PCE, was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a The result was unexpected due to the remote location of the well. Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was due to inadvertent contamination of the tubing fluid in the Westbay well-monitoring system. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency maximum contamination level (5 μg/L); the three wells were identified for rehabilitation as part of the INL well maintenance program. Well rehabilitation would either remove and replace the PCE-contaminated tubing fluid or remove the PCE from the tubing fluid. The interior of the Westbay well casing is isolated from the surrounding groundwater and filled with tubing fluid (either distilled or potable water). Groundwater samples are collected by opening sealed ports using a specialized sampling device. The unique construction prevents the direct interaction of the groundwater and tubing fluid. The tubing fluid also supports the structural integrity of the Westbay wells. The unique construction of the Westbay wells-i.e., the small diameter (5.08 cm [2 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface-posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity to the Westbay well, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Rehabilitation commenced during the summer of 2018 and is ongoing with measurable success. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sedimentary Geothermal Feasibility in Eastern Nevada and Millard County, Utah Well Databases

In order to gather data to assess sedimentary geothermal feasibility in Nevada and Utah, state oil and gas and geothermal databases were serached for well files and well logs. Well data from the Nevada Bureau of Mines and Geology oil and gas and geothermal databases was mined for the following areas in Nevada: Blackburn oil field, Marys River, North Willow Creek, Tomera Ranch, and Diamond Valley, all in the Elko Basin; Bacon Flat in Railroad Valley; and Steptoe Basin. For Pavant Butte in Utah, the State of Utah Division of Oil and Gas Well File and Well Log Searches were mined for well records in Millard County. Only wells close to Pavant Butte were mined for detailed information, but all Millard County wells are included in the database. Well files were searched for temperature, permeability, pressure information, and formation depth and thickness. Temperature values are uncorrected. Locations for some wells were converted from township and range locations to approximate latitude and longitude using Google Earth and Earth Point grids to locate well pads. If no well pad could be located for a well, the center of the smallest section available (usually partsect) was used as the approximate location.

15 GEOTHERMAL ENERGY↗