Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Spoof Plasmon Polaritons for NDE Applications an Experimental Demonstration

NASA is exploring the use of microwave spoof plasmon polaritons to detect defects in metallic structures. This work investigates the detection of simulated defects in the form of aluminum wires as small as 1.6 mm diameter and 2mm long that are placed in a grooved aluminum test article. The inclusions simulate manufacturing defects, and the sum of the delta impedance is shown to increase with increasing volume of added metal. A threshold value of 50Ω has been proposed for defect detection. In addition to detecting defects, the technique also estimates the volume of the defect.

Microwave↗

Magnetic Helicity Estimations in Models and Observations of the Solar Magnetic Field. III. Twist Number Method

We study the writhe, twist, and magnetic helicity of different magnetic flux ropes, based on models of the solar coronal magnetic field structure. These include an analytical force-free Titov–Démoulin equilibrium solution, non-force-free magnetohydrodynamic simulations, and nonlinear force-free magnetic field models. The geometrical boundary of the magnetic flux rope is determined by the quasi-separatrix layer and the bottom surface, and the axis curve of the flux rope is determined by its overall orientation. The twist is computed by the Berger–Prior formula, which is suitable for arbitrary geometry and both force-free and non-force-free models. The magnetic helicity is estimated by the twist multiplied by the square of the axial magnetic flux. We compare the obtained values with those derived by a finite volume helicity estimation method. We find that the magnetic helicity obtained with the twist method agrees with the helicity carried by the purely current-carrying part of the field within uncertainties for most test cases. It is also found that the current-carrying part of the model field is relatively significant at the very location of the magnetic flux rope. This qualitatively explains the agreement between the magnetic helicity computed by the twist method and the helicity contributed purely by the current-carrying magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Spoof Plasmon Sensing for NDE Application

NASA is exploring the use of microwave spoof plasmon polaritons to detect defects in metallic structures. This work investigates the detection of simulated defects in the form of aluminum wires as small as 1.6 mm diameter and 2 mm long that are placed in a grooved aluminum test article. The inclusions simulate manufacturing defects, and the sum of the delta impedance is shown to increase with increasing volume of added metal. Based on the results, a threshold value of 50Ω has been proposed for defect detection. In addition to detecting defects, the technique also estimates the volume of the defect.

Microwave↗

S-band Fence Study Phase 1: Estimating the Increased Level of Screening Volume Incursions

Motivation: CARA assesses collision risk for a set of high-value satellites. Deploying the S-band Fence (SBF) radar system will significantly increase the number of conjunctions to process, possibly overloading the current CARA system.Phase 1 study objective: Estimate changes in screening volume incursion rates caused by the SBF deploymentPhase 2 study objective: Estimate associated changes in serious conjunction rates (e.g., Pc > 10-4) Phase 3 study objective: Develop methods for filtering and prioritizing the increased tasking, as requiredAll to be discussed today are Phase I results

conjunction assessment operations↗

Suggested reference values for regional blood volumes in children and adolescents

Estimates of regional blood volumes (BVs) in humans are needed in dosimetric models of radionuclides and radiopharmaceuticals that decay in the circulation to a significant extent. These values are also needed to refine models of tissue elemental composition in computational human phantoms of both patients and exposed members of the general public. The International Commission on Radiological Protection (ICRP) in its Publication 89 provides reference values for total blood content in the full series of their reference individuals, to include the male and female newborn, 1 year-old, 5 year-old, 10 year-old, 15 year-old, and adult. Furthermore, Publication 89 provides reference values for the percentage distribution of total blood volume in 27 different blood-filled organs and tissues of the reference adult male and adult female. However, no similar distribution values are provided for non-adults. The goal of the present paper is to present a volumetric scaling methodology to derive these values for the same organs and tissues at ages younger than the reference adult. Finally, literature data on organ-specific vascular growth in the brain, kidneys, and skeletal tissues are also considered.

60 APPLIED LIFE SCIENCES↗

Role of boundary conditions in quantum computations of scattering observables

Quantum computing may offer the opportunity to simulate strongly interacting field theories, such as quantum chromodynamics, with physical time evolution. This would give access to Minkowski-signature correlators, in contrast to the Euclidean calculations routinely performed at present. However, as with present-day calculations, quantum computation strategies still require the restriction to a finite system size, including a finite, usually periodic, spatial volume. In this work, we investigate the consequences of this in the extraction of hadronic and Compton-like scattering amplitudes. Using the framework presented in Briceño et al., we estimate the volume effects for various 1+1D Minkowski-signature quantities and show that these can be a significant source of systematic uncertainty, even for volumes that are very large by the standards of present-day Euclidean calculations. We then present an improvement strategy, based in the fact that the finite volume has a reduced symmetry. This implies that kinematic points, which yield the same Lorentz invariants, may still be physically distinct in the periodic system. As we demonstrate, both numerically and analytically, averaging over such sets can significantly suppress the unwanted volume distortions and improve the extraction of the physical scattering amplitudes. As the improvement strategy is based only in kinematics, it can be applied without detailed knowledge of the system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Locoregional Control of Non-Small Cell Lung Cancer in Relation to Automated Early Assessment of Tumor Regression on Cone Beam Computed Tomography

Purpose: Large interindividual variations in volume regression of non-small cell lung cancer (NSCLC) are observable on standard cone beam computed tomography (CBCT) during fractionated radiation therapy. Here, a method for automated assessment of tumor volume regression is presented and its potential use in response adapted personalized radiation therapy is evaluated empirically. Methods and Materials: Automated deformable registration with calculation of the Jacobian determinant was applied to serial CBCT scans in a series of 99 patients with NSCLC. Tumor volume at the end of treatment was estimated on the basis of the first one third and two thirds of the scans. The concordance between estimated and actual relative volume at the end of radiation therapy was quantified by Pearson's correlation coefficient. On the basis of the estimated relative volume, the patients were stratified into 2 groups having volume regressions below or above the population median value. Kaplan-Meier plots of locoregional disease-free rate and overall survival in the 2 groups were used to evaluate the predictive value of tumor regression during treatment. Cox proportional hazards model was used to adjust for other clinical characteristics. Results: Automatic measurement of the tumor regression from standard CBCT images was feasible. Pearson's correlation coefficient between manual and automatic measurement was 0.86 in a sample of 9 patients. Most patients experienced tumor volume regression, and this could be quantified early into the treatment course. Interestingly, patients with pronounced volume regression had worse locoregional tumor control and overall survival. This was significant on patient with non-adenocarcinoma histology. Conclusions: Evaluation of routinely acquired CBCT images during radiation therapy provides biological information on the specific tumor. This could potentially form the basis for personalized response adaptive therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional reconstruction of x-ray emission volumes in magnetized liner inertial fusion from sparse projection data using a learned basis

The ability to visualize x-ray and neutron emission from fusion plasmas in 3D is critical to understand the origin of the complex shapes of the plasmas in experiments. Unfortunately, this remains challenging in experiments that study a fusion concept known as Magnetized Liner Inertial Fusion (MagLIF) due to a small number of available diagnostic views. Here, we present a basis function-expansion approach to reconstruct MagLIF stagnation plasmas from a sparse set of x-ray emission images. A set of natural basis functions is “learned” from training volumes containing quasi-helical structures whose projections are qualitatively similar to those observed in experimental images. Tests on several known volumes demonstrate that the learned basis outperforms both a cylindrical harmonic basis and a simple voxel basis with additional regularization, according to several metrics. Two-view reconstructions with the learned basis can estimate emission volumes to within 11% and those with three views recover morphology to a high degree of accuracy. The technique is applied to experimental data, producing the first 3D reconstruction of a MagLIF stagnation column from multiple views, providing additional indications of liner instabilities imprinting onto the emitting plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints on hydrothermal heat flux through the oceanic lithosphere from global heat flow

A significant discrepancy exists between the heat flow measured at the seafloor and the higher values predicted by thermal models of the cooling lithosphere. This discrepancy is generally interpreted as indicating that the upper oceanic crust is cooled significantly by hydrothermal circulation. The magnitude of this heat flow discrepancy is the primary datum used to estimate the volume of hydrothermal flow, and the variation in the discrepancy with lithospheric age is the primary constraint on how the hydrothermal flux is divided between near-ridge and off-ridge environments. The resulting estimates are important for investigation of both the thermal structure of the lithosphere and the chemistry of the oceans. We reevaluate the magnitude and age variation of the discrepancy using a global heat flow data set substantially larger than in earlier studies, and the GDHI (Global Depth and Heat Flow) model that better predicts the heat flow. We estimate that of the predicted global oceanic heat flux of 32 x 10(exp 12) W, 34% (11 x 10(exp 12) W) occurs by hydrothermal flow. Approximately 30% of the hydrothermal heat flux occurs in crust younger than 1 Ma, so the majority of this flux is off-ridge. These hydrothermal heat flux estimates are upper bounds, because heat flow measurements require sediment at the site and so are made preferentially at topographic lows, where heat flow may be depressed. Because the water temperature for the near-ridge flow exceeds that for the off-ridge flow, the near-ridge water flow will be even a smaller fraction of the total water flow. As a result, in estimating fluxes from geochemical data, use of the high water temperatures appropriate for the ridge axis may significantly overestimate the heat flux for an assumed water flux or underestimate the water flux for an assumed heat flux. Our data also permit improved estimates of the 'sealing' age, defined as the age where the observed heat flow approximately equals that predicted, suggesting that hydrothermal heat transfer has largely ceased. Although earlier studies suggested major differences in sealing ages for different ocean basins, we find that the sealing ages for the Atlantic, Pacific, and Indian oceans are similar and consistent with the sealing age for the entire data set, 65 +/- 10 Ma. The previous inference of a young (approximately 20 Ma) sealing age for the Pacific appears to have biased downward several previous estimates of the global hydrothermal flux. The heat flow data also provide indirect evidence for the mechanism by which the hydrothermal heat flux becomes small, which has often been ascribed to isolation of the igneous crust from seawater due to the hydraulic conductivity of the intervening sediment. We find, however, that even the least sedimented sites show the systematic increase of the ratio of observed to predicted heat flow with age, although the more sedimented sites have a younger sealing age. Moreover, the heat flow discrepancy persists at heavily sedimented sites until approximately 50 Ma. It thus appears that approximately 100-200 m of sediment is neither necessary nor sufficient to stop hydrothermal heat transfer. We therefore conclude that the age of the crust is the primary control on the fraction of heat transported by hydrothermal flow and that sediment thickness has a lesser effect. This inference is consistent with models in which hydrothermal flow decreases with age due to reduced crustal porosity and hence permeability.

Stein, Carol A.↗

Stereology techniques in radiation biology

Clinicians involved in conventional radiation therapy are very concerned about the dose-response relationships of normal tissues. Before proceeding to new clinical protocols, radiation biologists involved with conformal proton therapy believe it is necessary to quantify the dose response and tolerance of the organs and tissues that will be irradiated. An important focus is on the vasculature. This presentation reviews the methodology and format of using confocal microscopy and stereological methods to quantify tissue parameters, cell number, tissue volume and surface area, and vessel length using the microvasculature as a model tissue. Stereological methods and their concepts are illustrated using an ongoing study of the dose response of the microvessels in proton-irradiated hemibrain. Methods for estimating the volume of the brain and the brain cortex, the total number of endothelial cells in cortical microvessels, the length of cortical microvessels, and the total surface area of cortical microvessel walls are presented step by step in a way understandable for readers with little mathematical background. It is shown that stereological techniques, based on a sound theoretical basis, are powerful and reliable and have been used successfully.

Non-NASA Center↗

Concerning neutral flux shielding in the U-3M torsatron

The volume of the torsatron U-3M vacuum chamber is about 70 m{sup 3}, whereas the plasma volume is about 0.3 m{sup 3}. The large buffer volume of the chamber serves as a source of a substantial neutral flux into the U-3M plasma. A fraction of this flux falls onto the torsatron helical coils located in front of the plasma, due to which the dynamics of neutral influx into the plasma modifies. The shielding of the molecular flux from the buffer volume into the plasma is estimated using numerical calculations. Only about 10% of the incident flux reaches the plasma volume. Estimates show that about 20% of atoms escape beyond the helical coils without colliding with them. Under these conditions, the helical coils substantially affect the neutral flux. A discharge regime with a hot low-density plasma produced by a frame antenna is considered. The spatial distribution of the molecular density produced in this regime by the molecular flux from the chamber buffer volume after it has passed between the helical coils is calculated. The contributions of the fluxes emerging from the side and inner surfaces of the helical coils are considered. The calculations show that the shape of the spatial distribution of the molecular density differs substantially from the shape of the magnetic surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resource demand growth and sustainability due to increased world consumption

The paper aims at continuing the discussion on sustainability and attempts to forecast the impossibility of the expanding consumption worldwide due to the planet’s limited resources. As the population of China, India and other developing countries continue to increase, they would also require more natural and financial resources to sustain their growth. We coarsely estimate the volumes of these resources (energy, food, freshwater) and the gross domestic product (GDP) that would need to be achieved to bring the population of India and China to the current levels of consumption in the United States. We also provide estimations for potentially needed immediate growth of the world resource consumption to meet this equality requirement. Given the tight historical correlation between GDP and energy consumption, the needed increase of GDP per capita in the developing world to the levels of the U.S. would deplete explored fossil fuel reserves in less than two decades. These estimates predict that the world economy would need to find a development model where growth would be achieved without heavy dependence on fossil fuels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

Buckey, J. C.↗

An analysis of differential impact melt-crater scaling and implications for the terrestrial impact record

The volume of impact melt relative to that of the transient cavity is known to increase with the magnitude of the impact event. This paper investigates the influence of that phenomenon on the nature of terrestrial impact craters. A model of impact melting was used to estimate the volume of melt produced during the impact of chondritic projectiles into granite targets at velocities of 15, 25, and 50 km per sec. The results were compared with observed melt volumes at terrestrial craters, which were collated from the literature and paired with the transient-cavity diameters of their respective craters. Results show that the record on terrestrial craters is not inconsistent with the predictions of the model.

Grieve, R. A. F.↗

A first constraint on basal melt-water production of the Greenland ice sheet

The Greenland ice sheet has been one of the largest sources of sea-level rise since the early 2000s. However, basal melt has not been included explicitly in assessments of ice-sheet mass loss so far. Here, we present the first estimate of the total and regional basal melt produced by the ice sheet and the recent change in basal melt through time. We find that the ice sheet’s present basal melt production is 21.4 +4.4/−4.0 Gt per year, and that melt generated by basal friction is responsible for about half of this volume. We estimate that basal melting has increased by 2.9 ± 5.2 Gt during the first decade of the 2000s. As the Arctic warms, we anticipate that basal melt will continue to increase due to faster ice flow and more surface melting thus compounding current mass loss trends, enhancing solid ice discharge, and modifying fjord circulation.

Greenland Ice Sheet↗

Impact-induced thermal effects in the lunar and Mercurian regoliths

Thermal effects of micrometeoroid impact into the regoliths of the moon and Mercury, and some comparisons between the regoliths of the two bodies are presented. The impact calculations used to estimate the volumes of melt and vapor produced in the regoliths of the two bodies are described. An overview of the process of impact metamorphism in a modeled regolith target is presented, in which the roles played by impact velocity and target temperature in determining the quantities of melt and vapor are evaluated. The model impact process and fluxes are combined to estimate the production rates for impact melt and vapor on the two bodies, and the results are compared with those of previous studies. It is concluded that the rates of impact melting and vaporization on Mercury are much greater than on the moon. In a given period of time, a factor of 14 times more melt and 20 times more vapor are produced on Mercury than on the moon. A 'typical' Mercurian microcratering event produces 2.6 times more melt than its lunar counterpart; the flux calculated for Mercury is 5.5 times higher than it is at the moon.

Cintala, Mark J.↗

A method for estimating both the solubility parameters and molar volumes of liquids

Development of an indirect method of estimating the solubility parameter of high molecular weight polymers. The proposed method of estimating the solubility parameter, like Small's method, is based on group additive constants, but is believed to be superior to Small's method for two reasons: (1) the contribution of a much larger number of functional groups have been evaluated, and (2) the method requires only a knowledge of structural formula of the compound.

Fedors, R. F.↗