Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Does the Intent to Irradiate the Internal Mammary Nodes Impact Survival in Women With Breast Cancer? A Population-Based Analysis in British Columbia

Purpose: To determine the value of the intent to include internal mammary nodes (IMNs) in the radiation therapy (RT) volume for patients receiving adjuvant locoregional (breast or chest wall plus axillary and supraclavicular fossa) RT for breast cancer. Methods and Materials: 2413 women with node-positive or T3/4N0 invasive breast cancer, treated with locoregional RT from 2001 to 2006, were identified in a prospectively maintained, population-based database. Intent to include IMNs in RT volume was determined through review of patient charts and RT plans. Distant relapse free survival (D-RFS), breast cancer-specific survival (BCSS), and overall survival (OS) were compared between the two groups. Prespecified pN1 subgroup analyses were performed. Results: The median follow-up time was 6.2 years. Forty-one percent of study participants received IMN RT. The 5-year D-RFS for IMN inclusion and exclusion groups were 82% vs. 82% (p = 0.82), BCSS was 87% vs. 87% (p = 0.81), and OS was 85% vs. 83% (p = 0.06). In the pN1 subgroup, D-RFS was 90% vs. 88% (p = 0.31), BCSS was 94% vs. 92% (p = 0.18), and OS was 91% vs. 88% (p = 0.01). After potential confounding variables were controlled for, women who received IMN RT did not have significantly different D-RFS (hazard ratio [HR] = 1.02 (95% confidence interval [CI], 0.84-1.24; p = 0.85), BCSS (HR = 0.98 (95% CI, 0.79-1.22; p = 0.88), or OS (HR = 0.95; 95% CI, 0.78-1.15; p = 0.57). In the pN1 subgroup, IMN RT was associated with trends for improved survival that were not statistically significant: D-RFS (HR = 0.87; 95% CI, 0.63-1.22; p = 0.42), BCSS (HR = 0.85; 95% CI, 0.57-1.25; p = 0.39), and OS (HR = 0.78; 95% CI, 0.56-1.09; p = 0.14). Conclusions: After a median follow-up time of 6.2 years, although intentional IMN RT was not associated with a significant improvement in survival, this population-based study suggests that IMN RT may contribute to improved outcomes in selected patients with N1 disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Spectral Analysis as a Noninvasive Tool to Assess Autonomic Regulation of Cardiovascular Function

A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.

Knapp, Charles F.↗

The effect of composition on helium bubble nucleation in complex concentrated alloys

Molecular dynamics simulations of helium implantation have been performed in the MoNbTaTi complex concentrated alloy (CCA) to determine the impact of composition on helium clustering and bubble nucleation. It was found that compositions with lower interstitial atomic volume resulted in smaller cluster sizes, higher helium-to-vacancy ratios, and larger migration barriers. As the atomic volume decreases, it is harder to accommodate additional helium in the lattice and for helium to diffuse between interstitial sites, resulting in smaller cluster sizes. In particular, increasing molybdenum directly correlated with a decreased interstitial atomic volume and increased migration barrier. Niobium exhibited the opposite trend, where more niobium in the material resulted in larger interstitial atomic volumes and cluster sizes but lower migration barriers. The atomic volume was determined to be an indicator of the susceptibility of the material to helium bubble growth and could potentially be used as a metric to screen compositions for resistance to helium damage. In this way, properties such as available interstitial volumes could be used to screen materials more rapidly given the vast compositional space of CCAs.

McCarthy, Megan Jeanne [Sandia National Laboratori↗

SU-G-JeP4-05: Effects of Irregular Respiratory Motion On the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography

Purpose: Average or maximum intensity projection (AIP or MIP) images derived from 4DCT images are often used as a reference image for target alignment when free breathing Cone-beam CT (FBCBCT) is used for positioning a moving target at treatment. This method can be highly accurate if the patient has stable respiratory motion. However, a patient’s breathing pattern often varies irregularly. The purpose of this study is to investigate the effect of irregular respiration on the positioning accuracy of a moving target with FBCBCT. Methods: Eight patients’ respiratory motion curves were selected to drive a Quasar phantom with embedded cubic and spherical targets. A 4DCT of the moving phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. CBCTs of the phantom driven by the same breathing curves were acquired on a Varian TrueBeam and fused such that the zero positions of moving targets are the same on both CBCT and AIP images. The sphere and cube volumes and centrioid differences (alignment error) determined by MIP, AIP and FBCBCT images were compared. Results: Compared to the volume determined by FBCBCT, the volumes of cube and sphere in MIP images were 22.4%±8.8% and 34.2%±6.2% larger while the volumes in AIP images were 7.1%±6.2% and 2.7%±15.3% larger, respectively. The alignment errors for the cube and sphere with center-center matches between MIP and FBCBCT were 3.5±3.1mm and 3.2±2.3mm, and the alignment errors between AIP and FBCBCT were 2.1±2.6mm and 2.1±1.7mm, respectively. Conclusion: AIP images appear to be superior reference images than MIP images. However, irregular respiratory motions could compromise the positioning accuracy of a moving target if the target center-center match is used to align FBCBCT and AIP images.

60 APPLIED LIFE SCIENCES↗

SINDA/FLUINT Stratified Tank Modeling for Cryrogenic Propellant Tanks

A general purpose SINDA/FLUINT (S/F) stratified tank model was created to simulate self-pressurization and axial jet TVS; Stratified layers in the vapor and liquid are modeled using S/F lumps.; The stratified tank model was constructed to permit incorporating the following additional features:, Multiple or singular lumps in the liquid and vapor regions of the tank, Real gases (also mixtures) and compressible liquids, Venting, pressurizing, and draining, Condensation and evaporation/boiling, Wall heat transfer, Elliptical, cylindrical, and spherical tank geometries; Extensive user logic is used to allow detailed tailoring - Don't have to rebuilt everything from scratch!!; Most code input for a specific case is done through the Registers Data Block:, Lump volumes are determined through user input:; Geometric tank dimensions (height, width, etc); Liquid level could be input as either a volume percentage of fill level or actual liquid level height

Axial Jet↗

Effect of decreased gravity on circulation in the rat

It has been reported that hypokinesia and bed rest induce cardiovascular changes similar to those observed in space flights. Using an animal model that was developed in our laboratory and that was extensively studied and characterized in our laboratory and other laboratories in this country and abroad, we have studied circulatory mechanisms that occur during exposure to hypokinesia (with or without negative tilt) as well as during readaptation to control conditions (free activity). We believe that this study contributes to better understanding of mammalian circulatory mechanisms that operate under 1-g force and will serve to provide control data to be compared with cardiovascular data obtained in conditions of a Space lab. Because survey and anesthesia drastically decrease cardiac output and other circulatory parameters in rats, only unanesthetized rats were used in experiments. Aorta and right atrium of the animals were permanently cannulated fifteen to twenty days before experiments. Arterial and right ventricular blood pressures, cardiac output, cerebral and other regional blood flow, ECG, other cardiovascular parameters, and oxygen consumption were measured with techniques routinely used in our laboratory. Specifically, we undertook the following investigations during the period of three years: (1) A study of circulatory changes (right ventricular pressure, arterial blood pressure, heart rate, cardiac output) during exposure of rats to hypokinetic conditions. Used the head down tilted Holton-Musacchia system in order to compare the results with the results already obtained on unrestrained rats, (2) Humoral changes were investigated in animals exposed to hypokinesia; also, lymphocyte and neutrophil levels in hypokinetic animals (with or without tilt) were determined to ascertain the level of induced stress and possible changes observed in weightless animals, and (3) circulating blood volume was determined during and after hypokinesia.

Popovic, Vojin P.↗

Whole body measurement systems

A system for measuring the volume and volume variations of a human body under zero gravity conditions is disclosed. An enclosed chamber having a defined volume and arranged for receiving a human body is provided with means for infrasonically varying the volume of the chamber. The changes in volume produce resultant changes in pressure, and under substantially isentropic conditions, an isentropic relationship permits a determination of gas volume which, in turn, when related to total chamber volume permits a determination of the body volume. By comparison techniques, volume changes of a human independent of gravity conditions can be determined.

Ogle, J. S.↗

Mitigation of Galvanic Corrosion in Bolted Joint of AZ31B and Carbon Fiber-Reinforced Composite Using Polymer Insulation

The use of polymer insulation to mitigate galvanic corrosion was examined for bolted joints of AZ31B Mg alloy and carbon fiber-reinforced composite. To assess the corrosion behaviors of bolted joints with and without polymer insulation, solution immersion and salt spray exposure (ASTM B117) tests were conducted, and the corrosion depths and volumes were determined for the joint specimens after the tests. The polymer-insulated bolted joints exhibited much lower corrosion depths and volumes, highlighting the effective mitigation of galvanic corrosion. The reductions of joint strength in the post-corrosion joint specimens were relatively small (up to ~10%) in the polymer-insulated group but greater (up to 90%) in the group with no insulation. Cross-sectional characterization of post-corrosion joints with polymer insulation revealed local pits developed on AZ31B under galvanic influence, indicating that limited galvanic attack (that did not decrease the joining integrity significantly) could still occur during a long salt spray exposure (~1264 h) owing to the permeation of an aqueous corrosive medium.

36 MATERIALS SCIENCE↗

Human Factors Applications of Biomechanical Modeling

Biomechanical data collection and modeling has applications to the field of human factors. Specifically, motion data can be used to determine the operational volume necessary for performing a task. The operational volume assessment can be performed in order to determine how much volume is needed to perform the task or if task performance can be contained and adequately performed within an allocated volume. Motion and external force data, along with computational modeling techniques, can be used to estimate the internal loading produced during performance of a task. Internal loading estimates can be used to determine if an adequate stimulus is generated for maintenance of musculoskeletal health and also for comparison to injury thresholds to determine injury risk during task performance.

Lewandowski, Beth↗

Application of a dry-gas meter for measuring air sample volumes in an ambient air monitoring network

Ambient air monitoring for non-research applications (e.g. compliance) occurs at locations throughout the world. Often, the air sampling systems employed for these purposes employee simple yet robust equipment capable of handling the rigors of demanding sampling schedules. At the Hanford Site (near Richland, Washington) concentrations of radionuclides in ambient air are monitored continuously at 44 locations. In 2004, mechanical dry-gas meters were incorporated into the Hanford Site ambient air sample collection system to allow the direct measurement of sample volumes. These meters replaced a portable airflow measurement system that required two manual flow measurements and a sample duration measurement to determine sample volume. A six-month evaluation of the dry-gas meters compared sample volumes calculated using the original flow rate method to the direct sample volume measurement (new method). The results of the evaluation indicate that use of the dry-gas meters result in accurate sample volume measurements and provide greater confidence in the measured sample volumes. In several years of in-network use, the meters have proven to be reliable and have resulted in an improved sampling system.

54 ENVIRONMENTAL SCIENCES↗

Flexure fatigue testing of 90 deg graphite/epoxy composites

A great deal of research has been performed characterizing the in-plane fiber-dominated properties, under both static and fatigue loading, of advanced composite materials. To the author's knowledge, no study has been performed to date investigating fatigue characteristics in the transverse direction. This information is important in the design of bonded composite airframe structure where repeated, cyclic out-of-plane bending may occur. Recent tests characterizing skin/stringer debond failures in reinforced composite panels where the dominant loading in the skin is flexure along the edge of the frame indicate failure initiated either in the skin or else the flange, near the flange tip. When failure initiated in the skin, transverse matrix cracks formed in the surface skin ply closest to the flange and either initiated delaminations or created matrix cracks in the next lower ply, which in turn initiated delaminations. When failure initiated in the flanges, transverse cracks formed in the flange angle ply closest to the skin and initiated delamination. In no configuration did failure propagate through the adhesive bond layer. For the examined skin/flange configurations, the maximum transverse tension stress at failure correlates very well with the transverse tension strength of the composites. Transverse tension strength (static) data of graphite epoxy composites have been shown to vary with the volume of material stressed. As the volume of material stressed increased, the strength decreased. A volumetric scaling law based on Weibull statistics can be used to predict the transverse strength measurements. The volume dependence reflects the presence of inherent flaws in the microstructure of the lamina. A similar approach may be taken to determine a volume scale effect on the transverse tension fatigue behavior of graphite/epoxy composites. The objective of this work is to generate transverse tension strength and fatigue S-N characteristics for composite materials using 3-point flexure tests of 90 deg graphite/epoxy specimens. Investigations will include the volume scale effect as well as frequency and span-to-thickness ratio effects. Prior to the start of the experimental study, an analytical study using finite element modeling will be performed to investigate the span-to-thickness effect. The ratio of transverse flexure stress to shear stress will be monitored and its values predicted by the FEM analysis compared with the value obtained using a 'strength of materials' based approach.

Peck, Ann Nancy W.↗

Three-dimensional numerical simulation of current collection by a probe in a magnetized plasma

A three-dimensional numerical model for current collection in a magnetized plasma is reported. The model is based on an electrostatic particle-in-cell code. The model yields self-consistent sheath structure including distributions of plasma and the electric potential around the body and the collection of electrons. The analytical theory of current collection by a body in a magnetized plasma yields an upper bound for the collected current determined by the conservation of energy and canonical angular momentum. The theory shows that the collected charged particles come from a cylindrical volume aligned with the magnetic shadow of the body; the maximum radius r(sub o) of this volume is determined by the body size, body potential, and the ambient magnetic field. This theory does not deal with the sheath structure around the body. The condition for the actual current to approach the upper-bound value has been a matter of debate. Our simulations reveal when and why the collected current becomes equal to its upper-bound value. Sheath size in the radial direction perpendicular to the axial ambient magnetic field is determined by the current-limiting radius r(sub o). Our simulation yields time-average current in good agreement with its upper bound. This feature of the current collection is explained as follows: Once electrons enter the sheath, some of them are freely accelerated perpendicular to the magnetic field because they are demagnetized by the large gradients in the perpendicular electric fields. Simulations show a large perpendicular acceleration, producing perpendicular energy as large as that determined by the potential on the body, especially in the region where perpendicular electric fields (E perpendicular) are the strongest. An analysis shows that the demagnetization of electrons occurs above a threshold potential on the body. This threshold condition follows from the breakdown of the adiabaticity of the electron dynamics inside the sheath.

Singh, Nagendra↗

Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

Validation Studies↗

Effect of prolonged LBNP and saline ingestion on plasma volume and orthostatic responses during bed rest

Orthostatic intolerance remains a significant problem following space flight despite frequent use of the saline fluid-loading countermeasure and volitional use of an anti-gravity suite during reentry and landing. The purpose of this project is to examine the plasma volume (PV), endocrine, and orthostatic responses of bedrested subjects following 2-hr and 4-hr treatments of lower body negative pressure (LBNP) and saline ingestion. Ten healthy men were randomly assigned into 2 groups. Group A underwent a 4-hr LBNP/saline treatment on best rest day 5 and the 2-hr treatment on day 11. Group B underwent the 2-hr treatment on day 6 and the 4-hr treatment on day 10. Blood volume was determined before and after bed rest using radiolabelling. Changes in PV between measurements were calculated from changes in hematocrit and estimated red cell volume. Urinary excretion of anti-diuretic hormone (ADH) and aldosterone (ALD) were measured each day during the study. Orthostatic responses were measured using a ramp LBNP protocol before bed rest, before each treatment, and 24 hours after each treatment. Both 2-hr and 4-hr treatments resulted in a restoration of PV to pre-bed rest levels which persisted at least 24 hours. This increase in PV was associated with significant increases in urinary excretion of ADH and ALD. Twenty-four hours after the 4-hr treatment, the heart rate and pulse pressure response to LBNP were significantly lower and stroke volumes during LBNP were increased. Twenty-four hours after the 2-hr treatment, there was no evidence of improvement in orthostatic responses. These results suggest that a countermeasure which simply restores PV during space flight may not be sufficient for restoring orthostatic responses.

Fortney, Suzanne M.↗

TREATABILITY TEST REPORT FOR THE REMOVAL OF CHROMIUM FROM GROUNDWATER AT 100-D AREA USING ELECTROCOAGULATION

The U.S. Department of Energy (DOE) has committed to accelerate cleanup of contaminated groundwater along the Columbia River. The current treatment approach was driven by a series of Interim Action Records of Decision (IAROD) issued in the mid-1990s. Part of the approach for acceleration involves increasing the rate of groundwater extraction for the chromium plume north of the 100-D Reactor and injecting the treated water in strategic locations to hydraulically direct contaminated groundwater toward the extraction wells. The current treatment system uses ion exchange for Cr(VI) removal, with off-site regeneration of the ion exchange resins. Higher flow rates will increase the cost and frequency of ion exchange resin regeneration; therefore, alternative technologies are being considered for treatment at high flow rates. One of these technologies, electrocoagulation (EC), was evaluated through a pilot-scale treatability test. The primary purpose of the treatability study was to determine the effectiveness of Cr(VI) removal and the robustness/implementability of an EC system. Secondary purposes of the study were to gather information about derivative wastes and to obtain data applicable to scaling the process from the treatability scale to full-scale. The treatability study work plan identified a performance objective and four operational objectives. The performance objective for the treatability study was to determine the efficiency (effectiveness) of hexavalent chromium removal from the groundwater, with a desired concentration of {le} 20 micrograms per liter ({micro}g/L) Cr(VI) in the effluent prior to re-injection. Influent and effluent total chromium and hexavalent chromium data were collected using a field test kit for multiple samples per week, and from off-site laboratory analysis of samples collected approximately monthly. These data met all data quality requirements. Two of three effluent chromium samples analyzed in the off-site (that is, fixed) laboratory met the performance objective during the continuous operational testing. Effluent hexavalent chromium analyzed by the field laboratory met the performance goal in over 90 percent of the samples. All effluent hexavalent chromium samples during the batch testing with high influent hexavalent chromium concentrations ({approx}2000 {micro}g/L) met the performance objective. Although the EC system was able to meet the performance goal, it must be noted that it was not uncommon for the system to be operated in recycle mode to achieve the performance goal. The EC unit was sometimes, but not always, capable of a single pass treatment efficiency high enough to meet the performance goal, and recycling water for multiple treatment passes was effective. An operational objective was to determine the volume and composition of the waste streams to enable proper waste designation. The toxicity characteristic leaching procedure (TCLP) concentrations, pH, and free liquids were determined for solid material from the EC electrodes (mechanically removed scale), the filter press, and the tank bottoms for the effluent and waste collector tanks. These data met all data quality requirements. All solid-phase secondary waste streams were found to be below the TCLP limits for the toxicity characteristic, and a pH value within the limits for the corrosivity characteristic. Out of three samples, two (one of scale from the EC unit and one from filter press solids) failed the free liquid (paint filter) test, which is one of the acceptability criteria for Hanford's Environmental Restoration Disposal Facility (ERDF). The solid-phase waste generation rate was about 0.65-gallon of solid waste per 100 gallons of water treated. It is concluded that the solid-phase secondary waste generated from this technology under the conditions at the test site will meet the toxicity and corrosivity criteria for disposal. It is also concluded that with engineering and/or operational improvements, a solid-phase secondary waste could be produced that would meet the free liquid disposal requirements. The second operational objective was to assess the operational reliability and safety of the system. For the continuous operations testing period from July 23 to September 12,2007, the system was not able to operate unattended. An extensive period of startup and adjustment preceded continuous operations, but was unsuccessful in providing a suitable and robust operating condition. Primary operational reliability problems were related to the sensitivity of the solid separation process to operational conditions such that a robust operating procedure (for example, chemical dosage) was not identified during the treatability test. Poor solids separation and high effluent iron concentrations also led to operational difficulties associated with injection well fouling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cloud volume studies

A time history of cloud growth for the Titan 3 launch was obtained by using optical data provided by three Askania trackers (position of the cloud) and three Hasselblad cameras (cloud volume). Two quasi-independent measurements of ground cloud volume as a function of time were obtained. Aircraft time in the cloud, as measured by the rapid response nephelometer onboard the aircraft, was used for determining cloud volume. Cloud volume from aircraft measurements for the entire operation is summarized.

Bendura, R. J.↗